• 제목/요약/키워드: Specular reflector

검색결과 18건 처리시간 0.021초

Optical Simulation Study on the Effect of Reflecting Properties of Reflection Films on the Performances of Collimating Films for the LCD Backlight Applications

  • Lee, Jeong-Ho;Ju, Young-Hyun;Park, Ji-Hee;Lee, Ji-Young;Nahm, Kie-Bong;Ko, Jae-Hyeon;Kim, Joong-Hyun
    • Journal of Information Display
    • /
    • 제9권1호
    • /
    • pp.26-32
    • /
    • 2008
  • The dependence of optical performances of collimating films such as prism films and pyramid films on the reflecting properties of reflection films were investigated by using a ray tracing technique. The angular distribution of the luminance and the on-axis luminance gain were obtained by using a simple backlight model composed of a reflection film, a virtual flat light source, and a collimating film. Three kinds of reflecting properties were used, which were a perfect Lambertian reflector, a perfect mirror reflector, and a reflector having both diffuse and specular properties. It was found that the on-axis luminance gain was the highest in the simulation where a mirror reflector was used, while the viewing angle was the widest where the Lambertian reflector was used. This result indicates that it is necessary to optimize the simulation condition such as the reflecting properties in order to predict the optical performances of collimating films accurately. Quantitative correlation between the optical characteristics of collimating films and the reflecting properties of reflection films can be used to improve simulation technique for the development and the optimization of collimating films for LCD backlight applications.

반사 배광과 램프에 의한 반사광 흡수를 고려한 경면반사판 설계 알고리즘 개발 (Development of Specular Reflector Design Algorithm Considering Reflected Light Distribution and Light Absorption by Lamp)

  • 황재산;이정욱;김기훈;김훈
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2000년도 학술대회논문집
    • /
    • pp.35-40
    • /
    • 2000
  • 기구 배광이 전체적인 조명환경에 미치는 영향은 크며, 기구배광은 반사판, 프리즘 설계 등으로 구현된다. 또, 램프의 물리적 크기는 기구설계에서 무시할 수 없으며, 기구 설계자는 램프로 흡수되는 빛을 최소한으로 하여 기구를 설계하여야 한다. 기존의 반사판 설계 알고리즘의 경우 램프의 물리적인 크기를 고려하지 않았으며, 기구배광의 출력값도 몇몇의 경우에서는 오차를 발생하였다. 이에 본 논문에서는 램프의 키기를 고려한 반사판설계 알고리즘을 개발, 구현하여 이전의 기구설계 알고리즘이 가지고 있던 오차를 줄였으며 좋은 성과를 얻었다.

  • PDF

반사판을 이용한 태양광발전시스템 실증연구 (Demonstration Research of Photovoltaic System with Solar Reflectors)

  • 김용식;강기환;심상용;이후락;이진섭;홍진기
    • 한국태양에너지학회 논문집
    • /
    • 제29권1호
    • /
    • pp.64-69
    • /
    • 2009
  • This paper aims at enhancing the electric production efficiency of photovoltaic(PV) system. The electrical power of PV system is proportional to light intensity on a PV module surface. In this paper, we apply two types of systems to enhance power generation efficiency. First, of all, concentring sunlight using specular surface and one-axis tracking system which traces the sun with vertical direction are applied in this project. From this, we analyze the fixed type method and power generation efficiency.

Optimized TOF-PET detector using scintillation crystal array for brain imaging

  • Leem, Hyuntae;Choi, Yong;Jung, Jiwoong;Park, Kuntai;Kim, Yeonkyeong;Jung, Jin Ho
    • Nuclear Engineering and Technology
    • /
    • 제54권7호
    • /
    • pp.2592-2598
    • /
    • 2022
  • Research groups in the field of PET instrumentation are studying time-of-flight(TOF) technology to improve the signal-to-noise ratio of PET images. Scintillation light transport and collection plays an important role in improving the coincidence resolving time(CRT) of PET detector based on a pixelated crystal array. Four crystal arrays were designed by the different optical reflection configuration such as external reflectors and surface treatment on the CRT and compared with the light output, energy resolution and CRT. The design proposed in the study was composed of 8 × 8 LYSO crystal array consisted of 3 × 3 × 15 mm3 pixels. The entrance side was roughened while the other five surfaces were polished. Four sides of all crystal pixels were wrapped with ESR-film, and the entrance surface was covered by Teflon-tape. The design provided an excellent timing resolution of 210 ps and improved the CRT by 16% compared to the conventional method using a polishing treatment and ESR-film. This study provided a method for improving the light output and CRT of a pixelated scintillation crystal-based brain TOF PET detector. The proposed configuration might be an attractive detector design for TOF brain PET requiring fast timing performance with high cost-effectiveness.

콘서트홀에서 무대음향에 대한 무대 반사판의 영향 (The Effects of Stage Reflectors on Stage Acoustics in Concert Halls)

  • 김용희;김수연;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.87-91
    • /
    • 2005
  • The effects of the movable reflectors on the stage acoustics in Seoul's Sejong Performing Arts Center (3,048-seat multi-purpose hall, stage area of $270m^2$ within an orchestra shell) and Ceramic Palace Hall (440-seat concert hall, stage area of $105m^2$) were investigated. Acoustical parameters were evaluated by measuring stage and audience acoustics in the two halls. The study was primarily based on the stage support parameter STI proposed by Gade (Acustica 65, pp.193-203, 1989). Results showed that STI varied on the stage of the large hall according to the position of the reflectors, whereas STI did not vary in the small hall. In the large hall, a smaller clear stage area (bounded by the reflectors) yields an increase in both STI and other early energy measures. In the small hall, early energy decreases when its stage's surface diffusion was covered with specular reflectors.

  • PDF

Calcite 필러를 함유한 유리 복합체의 표면형상과 반사율 (Surface Morphology and Reflectance of Calcite Filler in Glass Composites)

  • 전재승;황성진;안지환;김형순
    • 한국재료학회지
    • /
    • 제19권8호
    • /
    • pp.407-411
    • /
    • 2009
  • Reflection properties, such as specular reflection and diffuse reflection, are very important optical properties for the reflector, which has high reflectance in the display and architecture industry. Calcite is lowcost, nontoxic, and stable over a wide temperature range. Therefore, it is one of the most widely using fillers in many industries and has some advantages over titania as a filler to improve reflectance. However, optical properties, especially those of ceramic-filled composites, have not been analyzed. We studied the reflectance of calcite composites with their surface roughness. The reflectance of the composites was determined using a UV-visible spectrometer. The surface morphology and the micro-structure of the composites were investigated by atomic force microscope. The reflectance of the composites was improved by increasing the content of calcite in the calcite-frit composite. The reflectance is related with the surface roughness in the composites. However, the reflectance depends on the calcite contents in materials with similar surface roughness.

SiPM을 사용한 두 층의 반응 깊이를 측정하는 양전자방출단층촬영기기의 검출기 모듈 설계 (Design of Two Layer Depth-encoding Detector Module with SiPM for PET)

  • 이승재
    • 한국방사선학회논문지
    • /
    • 제13권3호
    • /
    • pp.319-324
    • /
    • 2019
  • 실리콘광전증배관(Silicon Photomultiplier, SiPM)과 두 층의 섬광 픽셀 배열을 이용한 반응 깊이 측정 검출기를 설계하였으며, 위치 측정 능력을 DETECT2000을 사용하여 검증하였다. 섬광 픽셀의 면 처리와 반사체 조합을 통해 섬광 픽셀과 감마선이 반응한 위치를 추적하였다. 아래층은 광학적으로 연결된 부분을 제외하고 반사체로 처리하였으며, 위층은 가장 외곽부분을 제외하고 모두 광학적으로 연결되도록 처리하여 빛의 공유가 아래층에 비해 자유롭도록 구성하였다. 거울반사체와 난반사체, 섬광 픽셀의 거친 면과 매끈한 면의 조합을 통해 평면 영상을 획득하였으며, 층별 영상이 생성되는 위치를 측정하여 분석하였다. 앵거 알고리듬을 사용하여 SiPM의 16채널 신호를 4개의 채널로 감소시켜 영상을 재구성하였다. 섬광 픽셀의 거친면과 모든 반사체 조합에서 두 층으로 구분되는 것을 확인할 수 있었으며, 매끈한 면일 경우에는 모두 층 구분이 불가능한 것을 확인할 수 있었다. 따라서 거친 면의 섬광 픽셀과 반사체 조합을 사용한 검출기를 사용할 경우 전임상용 PET에서 반응 깊이 측정을 통해 검출 시야 외곽에서의 공간분해능을 향상시킬 수 있을 것이다.

실리콘 광증폭기와 반응깊이 측정방법을 이용한 수술용 베타 영상/감마 프로브 가능성 연구 (A Feasibility Study of a SiPM Based Intraoperative Beta Imaging/Gamma Probe using the Depth of Interaction Measurement)

  • 곽인석;강한규;손정환;이재성;홍성종
    • 대한의용생체공학회:의공학회지
    • /
    • 제37권1호
    • /
    • pp.7-14
    • /
    • 2016
  • Radiopharmaceutical agents for positron emission tomography (PET), such as $^{18}F$-FDG and $^{68}Ga$, have been used not only for whole-body PET imaging but also for intraoperative radionuclide-guided surgery due to their quantitative and sensitive imaging characteristics. Current intraoperative probes detect gamma or beta particles, but not both of them. Gamma probes have low sensitivities since a collimator has to be used to reduce backgrounds. Positron probes have a high tumor-to-background ratio, but they have a 1-2 mm depth limitation from the body surface. Most of current intraoperative probes produce only audible sounds proportional to count rates without providing tumor images. This research aims to detect both positrons and annihilation photons from $^{18}F$ using plastic scintillators and a GAGG scintillation crystal attached to silicon photomultiplier (SiPM). The depth-of-interaction (DOI) along the plastic scintillator can be used to obtain the 2-D images of tumors near the body surface. The front and rear part of the intraoperative probe consists of $4{\times}1$ plastic scintillators ($2.9{\times}2.0{\times}12.0mm^3$) for positron detection and a Ce:GAGG scintillation crystal ($12.0{\times}12.0{\times}9.0mm^3$) for annihilation photon detection, respectively. The DOI resolution of $4.4{\pm}1.6mm$ along the plastic scintillator was obtained by using the 3M enhanced specular reflector (ESR) with rectangular holes between the plastic scintillators, which showed the feasibility of a 2-D image pixel size of $2.9{\times}4.4mm^2$ (X-direction ${\times}$ Y-direction).