Study of Magnetohydrodynamic Turbulence Using Multi-frequency Synchrotron Polarization Observations

  • Lee, Hyeseung;Cho, Jungyeon;Lazarian, Alex
    • 천문학회보
    • /
    • 제44권1호
    • /
    • pp.44.2-44.2
    • /
    • 2019
  • Turbulent motions perturb magnetic field lines and produce magnetic fluctuations. The perturbations leave imprints of turbulence statistics on magnetic field. Observation of synchrotron radiation is one of the easiest ways to study turbulent magnetic field. First, we obtained the spatial spectrum of synchrotron polarization so that shows how the spectrum is affected by Faraday rotation and how to recover the statistics of underlying turbulence magnetic field. Since polarized synchrotron intensity arising from magnetized turbulence are anisotropic along the direction of mean magnetic field. Secondly, we studied quadrupole ratio to quantitatively describe the degree of anisotropy introduced by magnetic field at multi-wavelengths. This work demonstrated that the spectrum and quadrupole ratio of synchrotron polarization can be very informative tools to get detailed information about the statistical properties of MHD turbulence from radio observations of diffuse synchrotron polarization.

  • PDF

Partial Spectrum Detection and Super-Gaussian Window Function for Ultrahigh-resolution Spectral-domain Optical Coherence Tomography with a Linear-k Spectrometer

  • Hyun-Ji, Lee;Sang-Won, Lee
    • Current Optics and Photonics
    • /
    • 제7권1호
    • /
    • pp.73-82
    • /
    • 2023
  • In this study, we demonstrate ultrahigh-resolution spectral-domain optical coherence tomography with a 200-kHz line rate using a superluminescent diode with a -3-dB bandwidth of 100 nm at 849 nm. To increase the line rate, a subset of the total number of camera pixels is used. In addition, a partial-spectrum detection method is used to obtain OCT images within an imaging depth of 2.1 mm while maintaining ultrahigh axial resolution. The partially detected spectrum has a flat-topped intensity profile, and side lobes occur after fast Fourier transformation. Consequently, we propose and apply the super-Gaussian window function as a new window function, to reduce the side lobes and obtain a result that is close to that of the axial-resolution condition with no window function applied. Upon application of the super-Gaussian window function, the result is close to the ultrahigh axial resolution of 4.2 ㎛ in air, corresponding to 3.1 ㎛ in tissue (n = 1.35).

CAM 곡선 개선에 의한 차량용 공조기의 소음 저감 평가 (Evaluation for Noise Reduction of the HVAC by Modification of CAM Curve)

  • 정재은;정창용;서범준;정운창;오재응
    • 한국소음진동공학회논문집
    • /
    • 제21권9호
    • /
    • pp.787-797
    • /
    • 2011
  • The noise in a vehicle is an important factor for customers purchasing a car. Particularly, reduction of the noise that is generated from HVAC(heating, ventilation and air conditioning) is very important since it has considerable effects on interior noise. In general, identification of noise source is crucial to reduce noise level. The complex acoustic intensity method is widely used to obtain the accurate measurement and identification of noise source. Therefore, in the previous study, noise source of HVAC was identified through experimental approach using the complex acoustic intensity method. In this study, we are intended to confirm reduced level of noise by comparing the result between before and after modification of cam curve that is based on identified noise source of HVAC. It is found out that noise source of HVAC are motor and cam area using the complex acoustic intensity method in the previous study. We performed experiments to compare noise level between before and after modification of cam curve. Especially, it can be seen that complex acoustic intensity method using both active and reactive intensity is vital in devising a strategy for comparison to noise level. Also, the vector flow of acoustic intensity was investigated to identify sound intensity distributions and energy flow in the near field of HVAC.

실리콘산화막의 광루미니센스 온도의존성에 관한 연구 (Temperature Dependence of Photoluminescence in $SiO_2$)

  • 이재희
    • 한국진공학회지
    • /
    • 제10권2호
    • /
    • pp.247-251
    • /
    • 2001
  • 실리콘산화막에 $Si^+$이온을 주입하여 열처리를 한 후 상온에서 8K까지 온도를 변화시키며 PL을 측정하였다. 상온에서 50~80K까지는 PL intensity가 전체적으로 증가하였으며 50K 이하에서는 감소하였다. PL intensity가 증가하는 동안 peaks는 blue-shift가 일어났다. PL spectrum에서 peak를 보이는 파장에서 PL의 온도의존성을 측정하였다. 첫 번째 peak가 온도변화에 가장 민감하며 크기가 작은 peak일수록 온도의 영향을 적게 받는다. PL peak의 온도의존성을 분석하였다. 상온에서 50K 범위에서 PL intensity 대 1000/T그림에서 온도역수의 3차 함수로 fitting할 수 있었다. 온도가 내려갈수록 PL intensity가 증가하는 것을 nanocrystal 보다도 O위주 결함(Si-O-O)이나 Si위주 결함(Si-Si-O)들의 quantum size effect로 설명할 수 있었다.

  • PDF

정상 모음에 대한 구강 및 비강 spectral output 분석 (Oral and Nasal Spectral Outputs in Korean Oral Vowels)

  • 홍기환;최승철;김범규;양윤수;심현아
    • 음성과학
    • /
    • 제10권2호
    • /
    • pp.145-157
    • /
    • 2003
  • Vowels are classified by the shapes of vocal tract. These shapes form constriction points along the tract, which have an influence on such vocal tract resonance as F1, F2, F3, and so on. The formant frequency is influenced by aperture and placement of tongue and the intensity is influenced by air pressure of subglottis. The object of this study compares to characterize the spectral outputs of oral and nasal spectra for the formant frequencies and intensity of Korean oral vowels. Subjects consisted of 20 normal persons (10 male and 10 female) without laryngeal pathology. The speech sample included /a/, /e/, /i/, /o/, /u/ of Korean oral vowels. The spectrum of each vowel was analysed by Nasal View and Real Analysis Program using Dr. Speech. The result showed that nasal intensity is decreased manifestly from F1 to F2. But oral intensity and Intensity is decreased little bit from F1 to F2. The most of values of nasal formant frequency is similarity oral formant frequency and Formant frequency or little bit smaller.

  • PDF

가시광선의 파장과 광도가 광중합형 복합레진의 경화에 미치는 영향 (THE EFFECTS OF WAVELENGTH AND INTENSITY OF VISIBLE LIGHT ON THE CURING OF VISIBLE LIGHT CURED COMPOSITE RESIN)

  • 이채경;허복
    • Restorative Dentistry and Endodontics
    • /
    • 제14권1호
    • /
    • pp.149-159
    • /
    • 1989
  • The purpose of this study was to assess the effects of wavelength and intensity of light curing units on the curing of composite resin. The wavelength and intensity of nine units were evaluated with Optical Multichannel Analyzer and Radiometer. Two-part split stainless steel mold with a cylindrical hole-3.0mm in diameter, 6.0mm in hgieht-was prepared. After placing a Mylar strip between two parts, 100 specimens were made by inserting each of four composite resins into the mold and irradiating for 20 seconds with five light units alternatively. The curing depths were measured by scraping method and evaluated by two-way ANOVA. And Vicker's hardness measurements were made on the longitudinally sectioned surface at 0.5mm interval. The results were as follows: 1. Visilux 2 showed a narrow spectral band within the effective wavelength in initiating polymerization and the highest intensity. Translux showed the diffuse spectrum of wavelength and the lower light intensity. 2. Visilux 2 showed the highest curing effect in any composite resin and then followed by Optilux, Efos 35, Heliomat and Translux. (p < 0.01) 3. Durafill showed the deepest curing depth in any light unit and then followed by Bisfil M, Silux and Heliosit. (p < 0.01). 4. Maximum hardness values showed 0.1mm and 0.5mm under top surface and then gradually decreased with depth.

  • PDF

광 강도 제어에 따른 LED의 광질에 관한 연구 (A Study on Light Quality of LED for Control of Light Intensity)

  • 박상희;안준철;허정욱;최한고;최성대
    • 한국기계가공학회지
    • /
    • 제11권6호
    • /
    • pp.175-182
    • /
    • 2012
  • Light characteristics of the monochromatic red(R), blue(B), green(G) and white(W) and the mixed LED (B-R LED) were investigated by light control a Spectrometer-MMS1 and an illuminometer. The power consumption of each LED was 1W and R LED has five wavelength bands(600nm, 640nm, 660nm, 680nm, 750nm). The light intensity of each LED was changed in a range 10~100%. As a results, the wavelength and the spectrum distribution of R LED increase with increasing light intensity but the wavelength of B, G, W LED decreases. It was found that illumination of each mononochromatic and B-R LED increases linearly with increasing light intensity. It was confirmed that the illumination intensity of R-B light has greater values than those obtained by monochromatic light at the same conditions.

FTIR Spectroscopic Analysis of Structural Changes of Cellulosic Fibres During Papermaking Process

  • Kim, Hyoung-Jin
    • Journal of the Korean Wood Science and Technology
    • /
    • 제26권2호
    • /
    • pp.51-58
    • /
    • 1998
  • Structural changes of cellulosic fibres during the papermaking process were studied by analysis of FTIR spectra collected by the transmission method. The spectra were obtained from a carefully prepared handsheet, using a special infra-red (IR) cell suitable for evacuating the sample. The deconvolution technique was also applied for sharpening the FTIR spectra in the frequency range of the OH and CH stretching bands, which gave detailed information on the structural changes of cellulose. The intensity of some bands was decreased by predrying the sample as a result of the removal of adsorbed moisture. An increase in intensity of some bands in the frequency range of 3700 to $3200cm^{-1}$ was shown at a higher beating level. This increase in intensity was caused by changes in the crystal domain of cellulose resulting from the exposure of the crystalline area on the fibre surface.

  • PDF

Ar 가스 압력과 RF 전력변화에 따른 유도결합형ㆍ플라즈마 E-H모드 변환의 광학적 특성 (Optical E-H Transition Properties of Inductively Coupled Plasma with Ar Gas Pressure and RF Pourer)

  • 허인성;조주웅;이영환;김광수;최용성;박대희
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제53권1호
    • /
    • pp.20-23
    • /
    • 2004
  • In this paper, the emission properties of electrodeless fluorescent lamp were discussed using the inductively coupled plasma. To transmit the electromagnetic energy into the chamber, a RF power of 13.56 [MHz] was applied to the antenna and considering the Ar gas pressure and the RF electric power change, the emission spectrum, Ar I line, luminance were investigated. At this time, the input parameter for ICP RF plasma, Ar gas pressure and RF power were applied in the range of 10∼60 [mTorr], 10∼300 [W], respectively. From emission intensity and lumnance intensity results, the mode transition from E-mode to H-mode was observed. This implies that this method can be used to find an optimal RF power for efficient light illumination in an electrodeless fluorescent lamp.

分子衝突에 依한 光散亂 (Collision-Induced Light Scattering. Relation Between Spectral Shape and Molecular Interaction)

  • 신형규
    • 대한화학회지
    • /
    • 제17권4호
    • /
    • pp.240-246
    • /
    • 1973
  • 분자 혹은 원자간의 충돌에 의한 light scattering의 강도를 계산하는 이론식을 유도하였다. Argon을 예로하여 적은 진동수 shift에 나타나는 좁은 분광 band는 원자간의 장거리 효과가 이방성에 미치는 영향에 의한 것이고 큰 진동수 shift에서의 넓은 분광 band는 단거리 효과에 의한 것임을 지적하였다.