• Title/Summary/Keyword: Spectrum Harmonization

Search Result 8, Processing Time 0.031 seconds

Analysis of Radio Spectrum Policy for the Fifth Generation Mobile Communications (5G 이동통신을 위한 전파정책 분석)

  • Kim, Chang-Joo
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.8
    • /
    • pp.679-689
    • /
    • 2015
  • The 5G mobile communication technologies have been extensively developed with the era of mobile broadband, but spectrum policy for this service has not yet set up. In this paper, We have investigated the 5G mobile service and analyzed the 5G spectrum policy taking the developing technologies into account. Based on the results of these analyses, We propose an expansion of spectrum sharing in the 3~5 GHz bands, spectrum harmonization of 5 GHz bands, and restructuring of spectrum management administration from currently three distributed management to centralized spectrum management structure.

Database of virtual spectrum of artificial radionuclides for education and training in in-situ gamma spectrometry

  • Yoomi Choi;Young-Yong Ji;Sungyeop Joung
    • Nuclear Engineering and Technology
    • /
    • v.55 no.1
    • /
    • pp.190-200
    • /
    • 2023
  • As the field of application of in-situ gamma spectroscopy is diversified, proficiency is required for consistent and accurate analysis. In this study, a program was developed to virtually create gamma energy spectra of artificial nuclides, which are difficult to obtain through actual measurements, for training. The virtual spectrum was created by synthesizing the spectra of the background radiation obtained through actual measurement and the theoretical spectra of the artificial radionuclides obtained by a Monte Carlo simulation. Since the theoretical spectrum can only be obtained for a given geometrical structure, representative major geometries for in-situ measurement (ground surface, concrete wall, radioactive waste drum) and the detectors (HPGe, NaI(Tl), LaBr3(Ce)) were predetermined. Generated virtual spectra were verified in terms of validity and harmonization by gamma spectrometry and energy calibration. As a result, it was confirmed that the energy calibration results including the peaks of the measured spectrum and the peaks of the theoretical spectrum showed differences of less than 1 keV from the actual energies, and that the calculated radioactivity showed a difference within 20% from the actual inputted radioactivity. The verified data were assembled into a database and a program that can generate a virtual spectrum of desired condition was developed.

LTE Spectrum Policy: Focused on the OECD 12 Countries (이동통신 LTE 주파수 정책: 주요국 사례를 중심으로)

  • Jun, Soo-Yeon;Jeong, In-Jun
    • Journal of Digital Convergence
    • /
    • v.12 no.8
    • /
    • pp.1-18
    • /
    • 2014
  • Recently, many of the mobile network operators or telcos are introducing the LTE service in order to effectively cope with an explosive increasing mobile traffics due to an expansion of the use of smart phones. The 1.8GHz, 2.6GHz, and 800MHz band classes are most widely used for LTE. In particular, the 1.8GHz band class is the most useful one in terms of the reusability of the existing (2G) network, global harmonization, bandwidth, eco-system of equipments and devices, and so on. In recent years, major countries in the world have allocated the 1.8GHz band spectrum in a wide bandwidth unit suitable for the upcoming LTE-Advanced service. This paper surveyed the 1.8GHz band spectrum allocation policies of the 12 OECD countries, including Republic of Korea. From the survey, we have found that they rebuilt or refarmed the existing holders' bands, recovered the public (i.e., military)-use bands, and allocated the bands in a wide bandwidth and in an equal or similar size.

Validation of Method Determining Coixol in Coix lachryma-jobi var. ma-yuen Roots Extract (율무근 추출물의 Coixol 성분 분석법 검증)

  • Kwon, Jin Gwan;Seo, Changon;Choi, Yun-Hyeok;Choi, Chun Whan;Kim, Jin Kyu;Jeong, Wonsik;Lee, Ji Eun;O, Kyeong Hee;Hong, Seong Su
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.46 no.8
    • /
    • pp.952-956
    • /
    • 2017
  • An high performance liquid chromatography (HPLC) analysis method was developed for standard determination of coixol as a functional cosmetic material in Coix lachryma-jobi var. ma-yuen roots extract. HPLC was performed on a $C_{18}$ Unison US column ($4.6{\times}250mm$, $5{\mu}m$ column) using a gradient elution of 0.1% (v/v) trifluoroacetic acid and acetonitrile at a flow rate of 1.0 mL/min at $30^{\circ}C$. The analyte was detected at 290 nm. The HPLC method was validated in accordance with the International Conference on Harmonization guideline of analytical procedures with respect to specificity, precision, accuracy, and linearity. The limit of detection and quantitation were 0.07 and 0.25 mg/mL, respectively. Calibration curves showed good linearity ($R^2$>0.9995), and the precision of analysis was satisfied (less than 0.29%). Recoveries of quantified compounds ranged from 98.36 to 100.30%. This result indicates that the established HPLC method is very useful for the determination of a marker compound in C. lachryma-jobi var. ma-yuen roots extracts.

Validation of Method Determining Marmesin in Broussonetia kazinoki Extract (닥나무 추출물의 Marmesin 성분 분석법 검증)

  • Kwon, Jin Gwan;Seo, Changon;Hong, Seong Su;Seo, Dong-Wan;Oh, Joa Sub;Kim, Jin Kyu
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.45 no.11
    • /
    • pp.1604-1609
    • /
    • 2016
  • An HPLC analysis method was developed for standard determination of marmesin as a functional health material in Broussonetia kazinoki extract. HPLC was performed on a $C_{18}$ Kromasil column ($4.6{\times}250mm$, $5{\mu}m$) with a gradient elution of 0.1% (v/v) trifluoroacetic acid and acetonitrile at a flow rate of 1.0 mL/min at $30^{\circ}C$. The analyte was detected at 330 nm. The HPLC method was validated in accordance with International Conference on Harmonization guidelines for analytical procedures with respect to specificity, precision, accuracy, and linearity. The limit of detection and quantitation were 6.2 and $18.6{\mu}g/mL$, respectively. Calibration curves showed good linearity ($r^2$>0.9999), and the precision of analysis was satisfactory (less than 0.3%). Recoveries of quantified compound ranged from 100.35 to 101.18%. This result indicates that the established HPLC method is very useful for the determination of marker compounds in B. kazinoki extracts.

Method for Validation of Caffeoylquinic Acid Derivatives in Ligularia fischeri Leaf Extract as Functional Ingredients (건강기능식품 기능성 원료로서 곰취잎 추출물의 Caffeoylquinic Acid계 성분 분석법 검증)

  • Kwon, Jin Gwan;Kim, Jin Kyu;Seo, Changon;Hong, Seong Su;Ahn, Eun-Kyung;Seo, Dong-Wan;Oh, Joa Sub
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.45 no.1
    • /
    • pp.61-67
    • /
    • 2016
  • An HPLC analysis method was developed for standard determinations of chlorogenic acid, 3,4-di-O-caffeoylquinic acid, 3,5-di-O-caffeoylquinic acid, and 4,5-di-O-caffeoylquinic acid as functional health materials in Ligularia fischeri extract. HPLC was performed on a $C_{18}$ Kromasil column ($4.6{\times}250mm$, $5{\mu}m$ column) with a gradient elution of 0.1% (v/v) trifluoroacetic acid and acetonitrile at a flow rate of 1.0 mL/min at $30^{\circ}C$. The analytes were detected at 330 nm. The HPLC method was validated in accordance with the International Conference on Harmonization guideline of analytical procedures with respect to specificity, precision, accuracy, and linearity. The limits of detection and quantitation for the four compounds were 3.0~14.6 and $9.2{\sim}44.4{\mu}g/mL$, respectively. Calibration curves showed good linearity ($r^2$ > 0.999), and the precision of analysis was satisfied (less than 0.9%). Recoveries of quantified compounds ranged from 98.96 to 101.81%. This result indicates that the established HPLC method is very useful for the determination of marker compounds in Ligularia fischeri leaf extracts.

Modification and Validation of an Analytical Method for Dieckol in Ecklonia Stolonifera Extract (곰피추출물의 지표성분 Dieckol의 분석법 개선 및 검증)

  • Han, Xionggao;Choi, Sun-Il;Men, Xiao;Lee, Se-jeong;Oh, Geon;Jin, Heegu;Oh, Hyun-Ji;Kim, Eunjin;Kim, Jongwook;Lee, Boo-Yong;Lee, Ok-Hwan
    • Journal of Food Hygiene and Safety
    • /
    • v.37 no.3
    • /
    • pp.143-148
    • /
    • 2022
  • This study was to investigate an analytical method for determining dieckol content in Ecklonia stolonifera extract. According to the guidelines of International Conference on Harmonization. Method validation was performed by measuring the specificity, linearity, precision, accuracy, limit of detection (LOD), and limit of quantification (LOQ) of dieckol using high-performance liquid chromatography-photodiode array. The results showed that the correlation coefficient of calibration curve (R2) for dieckol was 0.9997. The LOD and LOQ for dieckol were 0.18 and 0.56 ㎍/mL, respectively. The intra- and inter-day precision values of dieckol were approximately 1.58-4.39% and 1.37-4.64%, respectively. Moreover, intra- and inter-day accuracies of dieckol were approximately 96.91-102.33% and 98.41-105.71%, respectively. Thus, we successfully validated the analytical method for estimating dieckol content in E. stolonifera extract.

Improvement and Validation of an Analytical Method for Quercetin-3-𝑜-gentiobioside and Isoquercitrin in Abelmoschus esculentus L. Moench (오크라 분말의 Quercetin-3-𝑜-Gentiobioside 및 Isoquercitrin의 분석법 개선 및 검증)

  • Han, Xionggao;Choi, Sun-Il;Men, Xiao;Lee, Se-jeong;Jin, Heegu;Oh, Hyun-Ji;Cho, Sehaeng;Lee, Boo-Yong;Lee, Ok-Hwan
    • Journal of Food Hygiene and Safety
    • /
    • v.37 no.2
    • /
    • pp.39-45
    • /
    • 2022
  • This study aimed to investigate the validation and modify the analytical method to determine quercetin-3-𝑜-gentiobioside and isoquercitrin in Abelmoschus esculentus L. Moench for the standardization of ingredients in development of functional health products. The analytical method was validated based on the ICH (International Conference for Harmonization) guidelines to verify the reliability and validity there of on the specificity, linearity, accuracy, precision, detection limit and quantification limit. For the HPLC analysis method, the peak retention time of the index component of the standard solution and the peak retention time of the index component of A. esculentus L. Moench powder sample were consistent with the spectra thereof, confirming the specificity. The calibration curves of quercetin-3-𝑜-gentiobioside and isoquercitrin showed a linearity with a near-one correlation coefficient (0.9999 and 0.9999), indicating the high suitability thereof for the analysis. A. esculentus L. Moench powder sample of a known concentration were prepared with low, medium, and high concentrations of standard substances and were calculated for the precision and accuracy. The precision of quercetin-3-𝑜-gentiobioside and isoquercitrin was confirmed for intra-day and daily. As a result, the intra-day precision was found to be 0.50-1.48% and 0.77-2.87%, and the daily precision to be 0.07-3.37% and 0.58-1.37%, implying an excellent precision at level below 5%. As a result of accuracy measurement, the intra-day accuracy of quercetin-3-𝑜-gentiobioside and isoquercitrin was found to be 104.87-109.64% and the daily accuracy thereof was found to be 106.85-109.06%, reflecting high level of accuracy. The detection limits of quercetin-3-𝑜-gentiobioside and isoquercitrin were 0.24 ㎍/mL and 0.16 ㎍/mL, respectively, whereas the quantitation limits were 0.71 ㎍/mL and 0.49 ㎍/mL, confirming that detection was valid at the low concentrations as well. From the analysis, the established analytical method was proven to be excellent with high level of results from the verification on the specificity, linearity, precision, accuracy, detection limit and quantitation limit thereof. In addition, as a result of analyzing the content of A. esculentus L. Moench powder samples using a validated analytical method, quercetin-3-𝑜-gentiobioside was analyzed to contain 1.49±0.01 mg/dry weight g, while isoquercitrin contained 1.39±0.01 mg/dry weight g. The study was conducted to verify that the simultaneous analysis on quercetin-3-𝑜-gentiobioside and isoquercitrin, the indicators of A. esculentus L. Moench, is a scientifically reliable and suitable analytical method.