• Title/Summary/Keyword: Spectrum Enhancement

Search Result 220, Processing Time 0.026 seconds

Structural Analysis of Major Antimicrobial Substance Obtained from Leaf Mustard(Brassica juncea) (갓(Brassica juncea)의 주 항균물질의 구조 분석)

  • 강성구
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.24 no.5
    • /
    • pp.702-706
    • /
    • 1995
  • A major component(compound A) in the ethylacetate fraction exhibited a strong antimicrobial activity was identified by UV, IR, FABMS and NMR. The compound A showed strong absorbance at 209, 259 and 359nm, indicating a flavonoid ring structure. IR spectrum possessed absorbance of OH at 3400∼3300cm-1, ketone at around 1650cm-1, and aromatic C=C at around 1660cm-1. Molecular weight of the compound A calculated as 478 from the information of m/z 479(M+H)+ and m/z 477(M-H)+ in the FABMS spectrum. Molecular formula of this compound was found to be C22H22O12 from m/z 479.1220(+3.1mmu for C22H23O12) of HRFABMS spectrum and from 13C-NMR spectrum. 1H-NMR and 13C-NMR spectra of the compound A revealed aromatic proton and benzene rings. Distortionless enhancement by polarization transfer(DEPT) exhibited that the compound A possessed 10 quaternary carbons and 3 substituted benzene rings including a methoxy group substitution. The compound A was identified as isorhamnetin 3-O-β-glucopyranoside by spectrophotometric methods in conjunction with 1H-1H COSY, 1H-13C COSY and HMBC, which revealed a flavone with OH group at 3, 5, 7, and 4' and methoxy group at 3' positions esterified to glucose.

  • PDF

Speech Enhancement using Spectral Subtraction and Two Channel Beamfomer (Spectral Subtraction과 Two Channel Beamfomer를 이용한 음성 강조 기법)

  • 김학윤
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.1
    • /
    • pp.38-44
    • /
    • 1999
  • In this paper, a new spectral subtraction technique with two microphone inputs is proposed. In conventional spectral subtraction using a single microphone, the averaged noise spectrum is subtracted from the observed short-time input spectrum. This results in reduction of mean value of noise spectrum only, the component varying around the mean value remaining intact. In the method proposed in this paper, the short-time noise spectrum excluding the speech component is estimated by introducing the blocking matrix used in Griffiths-Jim-type adaptive beamformer with two microphone inputs, combined with the spectral compensation technique. A simulation was conducted to verify the effectiveness of the method.

  • PDF

Efflorescence assessment using hyperspectral imaging for concrete structures

  • Kim, Byunghyun;Cho, Soojin
    • Smart Structures and Systems
    • /
    • v.22 no.2
    • /
    • pp.209-221
    • /
    • 2018
  • Efflorescence is a phenomenon primarily caused by a carbonation process in concrete structures. Efflorescence can cause concrete degradation in the long term; therefore, it must be accurately assessed by proper inspection. Currently, the assessment is performed on the basis of visual inspection or image-based inspection, which may result in the subjective assessment by the inspectors. In this paper, a novel approach is proposed for the objective and quantitative assessment of concrete efflorescence using hyperspectral imaging (HSI). HSI acquires the full electromagnetic spectrum of light reflected from a material, which enables the identification of materials in the image on the basis of spectrum. Spectral angle mapper (SAM) that calculates the similarity of a test spectrum in the hyperspectral image to a reference spectrum is used to assess efflorescence, and the reference spectral profiles of efflorescence are obtained from theUSGS spectral library. Field tests were carried out in a real building and a bridge. For each experiment, efflorescence assessed by the proposed approach was compared with that assessed by image-based approach mimicking conventional visual inspection. Performance measures such as accuracy, precision, and recall were calculated to check the performance of the proposed approach. Performance-related issues are discussed for further enhancement of the proposed approach.

Two-Microphone Binary Mask Speech Enhancement in Diffuse and Directional Noise Fields

  • Abdipour, Roohollah;Akbari, Ahmad;Rahmani, Mohsen
    • ETRI Journal
    • /
    • v.36 no.5
    • /
    • pp.772-782
    • /
    • 2014
  • Two-microphone binary mask speech enhancement (2mBMSE) has been of particular interest in recent literature and has shown promising results. Current 2mBMSE systems rely on spatial cues of speech and noise sources. Although these cues are helpful for directional noise sources, they lose their efficiency in diffuse noise fields. We propose a new system that is effective in both directional and diffuse noise conditions. The system exploits two features. The first determines whether a given time-frequency (T-F) unit of the input spectrum is dominated by a diffuse or directional source. A diffuse signal is certainly a noise signal, but a directional signal could correspond to a noise or speech source. The second feature discriminates between T-F units dominated by speech or directional noise signals. Speech enhancement is performed using a binary mask, calculated based on the proposed features. In both directional and diffuse noise fields, the proposed system segregates speech T-F units with hit rates above 85%. It outperforms previous solutions in terms of signal-to-noise ratio and perceptual evaluation of speech quality improvement, especially in diffuse noise conditions.

A Study on Hybrid Split-Spectrum Processing Technique for Enhanced Reliability in Ultrasonic Signal Analysis (초음파 신호 해석의 신뢰도 개선을 위한 하이브리드 스플릿-스펙트럼 신호 처리 기술에 관한 연구)

  • Huh, H.;Koo, K.M.;Kim, G.J.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.16 no.1
    • /
    • pp.1-9
    • /
    • 1996
  • Many signal-processing techniques have been found to be useful in ultrasonic and nondestructive evaluation. Among the most popular techniques are signal averaging, spatial compounding, matched filters and homomorphic processing. One of the significant new process is split-spectrum processing(SSP), which can be equally useful in signal-to-noise ratio(SNR) improvement and grain characterization in several specimens. The purpose of this paper is to explore the utility of SSP in ultrasonic NDE. A wide variety of engineering problems are reviewed, and suggestions for implementation of the technique are provided. SSP uses the frequency-dependent response of the interfering coherent noise produced by unresolvable scatters in the resolution range cell of a transducer. It is implemented by splitting the frequency spectrum of the received signal by using gaussian bandpass filter. The theoretical basis for the potential of SSP for grain characterization in SUS 304 material is discussed, and some experimental evidence for the feasibility of the approach is presented. Results of SNR enhancement in signals obtained from real four samples of SUS 304. The influence of various processing parameters on the performance of the processing technique is also discussed. The minimization algorithm, which provides an excellent SNR enhancement when used either in conjunction with other SSP algorithms like polarity-check or by itself, is also presented.

  • PDF

Robust Speech Enhancement Based on Soft Decision Employing Spectral Deviation (스펙트럼 변이를 이용한 Soft Decision 기반의 음성향상 기법)

  • Choi, Jae-Hun;Chang, Joon-Hyuk;Kim, Nam-Soo
    • Journal of the Institute of Electronics Engineers of Korea SP
    • /
    • v.47 no.5
    • /
    • pp.222-228
    • /
    • 2010
  • In this paper, we propose a new approach to noise estimation incorporating spectral deviation with soft decision scheme to enhance the intelligibility of the degraded speech signal in non-stationary noisy environments. Since the conventional noise estimation technique based on soft decision scheme estimates and updates the noise power spectrum using a fixed smoothing parameter which was assumed in stationary noisy environments, it is difficult to obtain the robust estimates of noise power spectrum in non-stationary noisy environments that spectral characteristics of noise signal such as restaurant constantly change. In this paper, once we first classify the stationary noise and non-stationary noise environments based on the analysis of spectral deviation of noise signal, we adaptively estimate and update the noise power spectrum according to the classified noise types. The performances of the proposed algorithm are evaluated by ITU-T P. 862 perceptual evaluation of speech quality (PESQ) under various ambient noise environments and show better performances compared with the conventional method.

Analysis of Characteristics of Seismic Source and Response Spectrum of Ground Motions from Recent Earthquake near the Backryoung Island (최근 백령도해역 발생지진의 지진원 및 응답스펙트럼 특성 분석)

  • Kim, Jun-Kyoung
    • Geophysics and Geophysical Exploration
    • /
    • v.14 no.4
    • /
    • pp.274-281
    • /
    • 2011
  • We analysed ground motions form Mw 4.3 earthquake around Backryoung Island for the seismic source focal mechanism and horizontal response spectrum. Focal mechanism of the Backryoung Islands area was compared to existing principal stress orientation of the Korean Peninsula and horizontal response spectrum was also compared to those of the US NRC Regulatory Guide (1.60) and the Korean National Building Code. The ground motions of 3 stations, including vertical, radial, and tangential components for each station, were used for grid search method of moment tensor seismic source. The principal stress orientation from this study, ENE-WSW, is consistent fairly well with that of the Korean Peninsula. The horizontal response spectrum using 30 observed ground motions analysed and then were compared to both the seismic design response spectra (Reg Guide 1.60), applied to the domestic nuclear power plants, and the Korean Standard Design Response Spectrum for general structures and buildings (1997). Response spectrum of 30 horizontal ground motions were used for normalization with respect to the peak acceleration value of each ground motion. The results showed that the horizontal response spectrum revealed higher values for frequency bands above 3 Hz than Reg. Guide (1.60). The results were also compared to the Korean Standard Response Spectrum for the 3 different soil types and showed that the vertical response spectra revealed higher values for the frequency bands below 0.8 second than the Korean Standard Response Spectrum (SD soil condition). However, through the qualitative improvements and quantitative enhancement of the observed ground motions, the conservation of horizontal seismic design response spectrum should be considered more significantly for the higher frequency bands.

Measurement and Analysis of the Korean NDGPS Radiation Spectrum

  • Kim, Young-Wan;Jee, Suk-Kun
    • Journal of information and communication convergence engineering
    • /
    • v.10 no.3
    • /
    • pp.225-230
    • /
    • 2012
  • The Korean nationwide differential global positioning system (NDGPS) reference station transmits a global positioning system (GPS) enhancement signal using minimum shift keying modulation with a 200 bps data rate. The ocean-based DGPS covers the service area of 100 NM with 300 W output power; on the other hand, the land-based DGPS transmits the output power of 500 W, which covers the service area of 100 km. The DGPS reference stations with high output power can radiate spurious signals, which may act as interference sources affecting the other DGPS reference stations or the wireless ground stations that utilize the medium frequency band. In this paper, the radiation spectrums of the DGPS reference stations are measured and analyzed in the spurious domain. The DGPS radiation spectrums are evaluated from the perspective of the interference effect.

Modification of ground motions using wavelet transform and VPS algorithm

  • Kaveh, A.;Mahdavi, V.R.
    • Earthquakes and Structures
    • /
    • v.12 no.4
    • /
    • pp.389-395
    • /
    • 2017
  • In this paper a simple approach is presented for spectral matching of ground motions utilizing the wavelet transform and a recently developed metaheuristic optimization technique. For this purpose, wavelet transform is used to decompose the original ground motions to several levels, where each level covers a special range of frequency, and then each level is multiplied by a variable. Subsequently, the vibrating particles system (VPS) algorithm is employed to calculate the variables such that the error between the response and target spectra is minimized. The application of the proposed method is illustrated through modifying 12 sets of ground motions. The results achieved by this method demonstrate its capability in solving the problem. The outcomes of the VPS algorithm are compared to those of the standard colliding bodies optimization (CBO) to illustrate the importance of the enhancement of the algorithm.

An Optimization of the 3D $^{1}H-^{15}N-^{1}H$ TOCSY-HSQC and NOESY-HSQC Experiments Using Sensitivity Enhancement with Gradient Selection

  • Jeon, Young-Ho;Kim, Kuk-Hyun
    • Journal of the Korean Magnetic Resonance Society
    • /
    • v.1 no.2
    • /
    • pp.103-111
    • /
    • 1997
  • Proper pulse sequences and experimental optimization for the 3D 15N edited TOCSY and NOESY spectra were described. Using sensitivity enhancement approach with coherent selection by pulsed field gradients described by Kay and co-workers, an considerable gain in sensitivity was achieved. The sensitivity was also improved by minimal water saturation using water flip-back pulse. Among the three types of TOCSY mixing pulse, named MLEV-17, DIPSI-2rc, DIPSI-2rc sequence gave the most sensitive spectrum. These results suggest an appropriate pulse sequence for for those 3D experiments for large proteins.

  • PDF