• Title/Summary/Keyword: Spectrum Analyzing

Search Result 312, Processing Time 0.029 seconds

THERMAL AND NON-THERMAL RADIO CONTINUUM SOURCES IN THE W51 COMPLEX

  • MOON DAE-SIK;KOO BON-CHUL
    • Journal of The Korean Astronomical Society
    • /
    • v.27 no.1
    • /
    • pp.81-102
    • /
    • 1994
  • We have decomposed the 11-cm radio continuum emission of the W51 complex into thermal and non-thermal components. The distribution of the thermal emission has been determined by analyzing HI, CO, and IRAS $60-{\mu}m$ data. We have found a good correlation between the 11-cm thermal continuum and the 60- 11m emissions, which is used to obtain the thermal and non-thermal 11-cm continuum maps of the W51 complex. Most of the thermal continuum is emanating from the compact H II regions and their low-density ionized envelopes in W51A and W51B. All the H II regions, except G49.1-0.4 in W51B, have associated molecular clumps. The thermal radio continuum fluxes of the compact H II regions are proportional to the CO fluxes of molecular clumps. This is consistent with the previous results that the total mass of stars in an H II region is proportional to the mass of the associated molecular clump. According to our result, there are three non-thermal continuum sources in W51: G49.4-0.4 in W51A, a weak source close to G49.2-0.3 in W51B, and the shell source W51C. The non-thermal flux of G49.5-0.4 at 11-cm is $\~28 Jy$, which is $\~25\%$ of its total 11-cm flux. The radio continuum spectrum between 0.15 and 300 GHz also suggests an excess emission over thermal free-free emission. We show that the excess emission can be described as a non-thermal emission with a spectral index ${\alpha}{\simeq}-1.0 (S_v{\propto}V^a)$ attenuated by thermal free-free absorptions at low-frequencies. The non-thermal source close to G49.2-0.3 is weak $(\~9 Jy)$. The nature of the source is not known and the reality of the non-thermal emission needs to be confirmed. The non~thermal shell source W51C has a 11-cm flux of $\~130Jy$ and a spectral index ${\alpha}{\simeq}-0.26$.

  • PDF

Diagnosis of Insulation Deterioration in Cast-Resin Power Transformer using Acoustic Emission Techniques (음향방출법에 의한 몰드형 전력변압기의 절연열화 진단)

  • 이상우;김인식;이동인;이광식
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.14 no.6
    • /
    • pp.35-42
    • /
    • 2000
  • In this paper, AE(Acoustic Emission) signals detected from the growth of the electrical tree in an epoxy resin under ac high-voltage application were analysed to diagnose the insulation deterioration of cast-resin power transformer. Frequency spectra of AE signals generated from the magnetizing and the load currents in the actual operating cast-resin power transformer of 500[kVA] under distribution system of 22.9[kV] were also analysed to distinguish the AE signals due to void discharges from the magnetic circuit noises in the core of the transformer. As the experimental results, we could distinguish the AE signals whether those signals were caused due to the void discharges or due to the magnetic circuit noises by analyzing the frequency spectrum of AE signals. The frequency spectra of AE signals generated from the cast-resin power transformer in operation due to both the magnetizing and the load currents appeared in the range of 40-120[kHz], but the frequency band of AE signals emitted from the void discharges in an epoxy resin sample was about 50[kHz] to 230[kHz].

  • PDF

A Study on the accuracy of Rangefinder between vessels by use of GPS (GPS를 이용한 선간거리계의 정확도에 관한 연구)

  • 김광홍
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.35 no.3
    • /
    • pp.215-226
    • /
    • 1999
  • The experimented rangefinder consist of sets of V/A-Code GPS and sets of L1 C/A-code & carrier phase receivers connected by two spread spectrum radio modems in order to measure relative range and bearing between two ship antennas by real time, comparing and analyzing accuracy of both GPS receivers at the fix point on the land by means of executing zero baseline test by C/A code and by carrier phase as well as measuring distance range 5m, 10m, 15m between each other receivers. The results from the measurement of relative range and bearing are as follows as ;1. According to the results from zero baseline test, the average error by C/A-code receiver is less than 0.1m, which proves theories from published books but when each GPS receivers track different satellites, the range accuracy error becomes up to 100m by means of S/A. Because of this sudden wide range error, rangefinder is not appropriate at relative range measurement without additional modification of the algorism of the GPS receiver itself.2. According to relative range measurement by Carrier Phase and zero baseline test at static condition, the range error is less than 3.5cm in case that it passes more than 5 minutes after GPS sets can track simultaneously more than 6 satellites. Its main reason is understood that the phase center of antenna is bigger than geodetic antenna.3. When range measurement of two receivers from 5m, to 10m to 15m, the each range error is 0.340m, 0.190m, 0.011m and each standard variation is 0.0973m, 0.0884m, 0.0790m. The range error and standard variation are in inverse proportion to distance between two receivers. 4. L1 Carrier Phase GPS generally needs 5 minutes to fix and during this ambiguity search, the relative range and bearing angle is shown to be various.

  • PDF

Comparison of Quality Characteristics of Sesame Oil and Blend Oil by Using Component Analysis and NIR Spectroscopy (참기름과 혼합유의 성분 및 NIR Spectrum 분석을 통한 품질특성 비교)

  • Joo, Jae-young;Yeo, Yong-heon;Lee, Namrye
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.46 no.6
    • /
    • pp.739-743
    • /
    • 2017
  • Product distribution and consumption in the military is difficult due to unique contracts and supply systems. It is difficult to change suppliers immediately when quality problem is encountered. Due to these special circumstances, the quality of products must be thoroughly controlled. Sesame oil is used to increase the taste and nutrition of food, but it is more expensive than other cooking oils. Oil producers may blend other cooking oils with sesame oil to make higher profits, so it has become important to identify good and bad products. In this study, pure sesame oil and blend oils were compared by analyzing their smell, taste, chemical components, and near infra-red spectra to determine quality differences between them.

A Study of Salmon Oil Type Analysis by FT-IR and Carbon Isotopes Ratio (FT-IR과 탄소동위원소 분석을 통한 연어유의 구분에 관한 연구)

  • Cho, Eun-Ah;Cha, Yun-Hwan;Lee, Young-Sang
    • The Korean Journal of Food And Nutrition
    • /
    • v.25 no.4
    • /
    • pp.968-973
    • /
    • 2012
  • This study analyzes the structure types of salmon oil to evaluate the purity of salmon oil products based on the 38 different types of imported salmon oil products distributed in the Republic of Korea. The major types of omega-3 foods in the salmon oil are ethyl ester (EE) and triglyceride (TG). If the salmon oil contained potential contaminants and was processed in order to remove it, EE type omega-3 fatty acids are found in concentration. This provides a good guide in assessing if products were made with EE type ingredients or re-esterified contaminated materials. The results of the FT-IR analysis showed significant difference in the C=O, C-O band positions in TG and EE. There were 19 TG type products and 19 EE type products. The analysis of carbon isotope ratio was performed on the types of TG and EE. There were different properties in the 19 TG type products. In one product, the carbon isotope ratio was -25.15 and the other 18 products showed -22.15~-23.96. The carbon isotope ratio of all 19 EE type products showed -21.91~-23.74. The results of the TLC analysis showed similar results with FR-IR. The re-esterified TG form was not detected in the TG type products, confirming that the TG type products contained natural salmon oil. This study aimed to provide the basic material in classifying the types of natural salmon oil and re-esterified salmon oil, by analyzing the pattern and proportion of FT-IR spectrum, carbon isotope ratio, and TLC.

A Study on the Optimization of the ITO/Ag/ITO Multilayer Transparent Electrode by Using In-line Magnetron Sputtering (인라인 마그네트론 스퍼티링에 의한 ITO/Ag/ITO 다층 구조 투명전극의 최적화에 관한 연구)

  • Lee, Seung Yong;Yoon, Yeo Tak;Cho, Eou Sik;Kwon, Sang Jik
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.30 no.3
    • /
    • pp.162-169
    • /
    • 2017
  • Indium tin oxide (ITO) thin films show a low sheet resistance and high transmittance in the visible range of the spectrum. Therefore, they play an important role as transparent electrodes for flat panel displays. However, their resistivity is rather high for use as a transparent electrode in large displays. One way to improve electrical and optical properties in large displays is to use ITO/Ag/ITO multilayer films. ITO/Ag/ITO multilayer films have lower sheet resistance than single layer ITO films with the same thickness. Prior to the ITO/Ag/ITO multilayer experiments, optimal condition for thickness change are necessary. Their thicknesses were deposited differently in order to analyze electrical and optical properties. However, when optimal single film characteristics are applied to ITO/Ag/ITO multilayer films, other phenomena appeared. After analyzing the electrical and optical properties by changing ITO and Ag film thickness, ITO/Ag/ITO multilayer films were optimized. By combining ITO film at $586\;{\AA}$ and Ag film at 10 nm, the ITO/Ag/ITO multilayer films showed optimized high optical transmittance of 87.65%, and the low sheet resistance of $5.5{\Omega}/sq$.

The Calibration of $^{90}$ Sr Ophthalmic Applicator by Measuring Electron Current (전류 측정 방식에 의한 안과용 $^{90}$ Sr 선원의 교정)

  • 이병용;신동오;김현자;홍성언;최은경;장혜숙
    • Progress in Medical Physics
    • /
    • v.2 no.2
    • /
    • pp.149-154
    • /
    • 1991
  • We have designed and applied the calibrationmethod of $\^$90/Sr Ophthalmic Applicaton by measuring the electron currents. We considered the number of electrons which is emitted from the source, the area of the source, and the electron stopping power in the water, and those data were used for calculation. Film was used for evaluating the accurate source area. Average electron stopping power was obtained by analyzing ${\beta}$-ray energy spectrum. We compared between the result from our method and that from the TLD measurements. The calibration result from our method shows 63.3 ${\pm}$5.1 cGy/sec, while 50.7${\pm}$7.3 cGy/sec from TLD measurement. But the supplier's specification tells 46.89.4cGy/sec.

  • PDF

The Study of Cognitive Function and EEG Spectrum Difference between Allergic Rhinitis and Normal Children (뇌파측정을 이용한 비염 환아와 정상아의 주의집중력에 관한 연구)

  • Lee, Nam-Yeol;Kim, Yun-Hee;Han, Jae-Kyung
    • The Journal of Pediatrics of Korean Medicine
    • /
    • v.21 no.2
    • /
    • pp.1-12
    • /
    • 2007
  • Objectives : Allergic children have known to have multiple behavior problems. Among them, attentional ability disorder is one of the most common problems. This study is to examine relationship between learning ability and allergic rhinitis by analyzing EEG status of children. Methods : We analyzed cognitive functions of two different children groups; 21 children with allergic rhinitis and 19 normal children with CANS 3000(Central & Autonomic Nervous System, LAXTHA Inc., Korea), cognitive functions assessment program by EEG. Results : 1. According to mean active EEG rhythm of Theta, Alpha, SMR, M-beta, there were no significant difference between allergic rhinitis and the normal group. 2. According to mean active EEG rhythm of right H-beta, Gamma wave allergic rhinitis group's value was significantly higher than that of the normal group. 3. According to mean cognitive strength, response, concentration, left / right brain activity and learning ability score, there were no significant difference between allergic rhinitis and the normal group. 4. According to mean workload score, allergic rhinitis group's value was significantly higher than that of the normal group. Conclusions : It is likely that allergic rhinitis group, which showed relatively high frequency EEG rhythm, is more fragile to stress and less active on mental processing. Along side with physical examination, psychological assessment should also be conjugated on treating children with allergic rhinitis.

  • PDF

Aero-elastic wind tunnel test of a high lighting pole

  • Luo, Yaozhi;Wang, Yucheng;Xie, Jiming;Yang, Chao;Zheng, Yanfeng
    • Wind and Structures
    • /
    • v.25 no.1
    • /
    • pp.1-24
    • /
    • 2017
  • This paper presents a 1:25 multi-freedom aero-elastic model for a high lighting pole at the Zhoushan stadium. To validate the similarity characteristics of the model, a free vibration test was performed before the formal test. Beat phenomenon was found and eliminated by synthesis of vibration in the X and Y directions, and the damping ratio of the model was identified by the free decay method. The dynamic characteristics of the model were examined and compared with the real structure; the similarity results were favorable. From the test results, the major along-wind dynamic response was the first vibration component. The along-wind wind vibration coefficient was calculated by the China code and Eurocode. When the peak factor equaled 3.5, the coefficient calculated by the China code was close to the experimental result while Eurocode had a slight overestimation of the coefficient. The wind vibration coefficient during typhoon flow was analyzed, and a magnification factor was suggested in typhoon-prone areas. By analyzing the power spectrum of the dynamic cross-wind base shear force, it was found that a second-order vortex-excited resonance existed. The cross-wind response in the test was smaller than Eurocode estimation. The aerodynamic damping ratio was calculated by random decrement technique and the results showed that aerodynamic damping ratios were mostly positive at the design wind speed, which means that the wind-induced galloping phenomenon is predicted not to occur at design wind speeds.

Combined Hybrid Beamforming and Spatial Multiplexing for Millimeter-Wave Massive MIMO Systems (밀리미터파 Massive MIMO 시스템을 위한 공간 다중화 및 하이브리드 빔 형성)

  • Ju, Sang-Lim;Lee, Byung-Jin;Kim, Nam-Il;Kim, Kyung-Seok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.5
    • /
    • pp.123-129
    • /
    • 2018
  • Recently, as required wireless communication traffic increase, millimeter wave mobile technologies that can secure broadband spectrum are gaining attention. However, the path loss is high in the millimeter wave channel. Massive MIMO system is being researched in which can complement the path loss by beamforming by equiped large-scale antenna at the base station. While legacy beamforming techniques have analog and digital methods, practical difficulties exist for application to massive MIMO systems in terms of system complexity and cost. Therefore, this paper studies a hybrid beamforming scheme for massive MIMO system in the millimeter wave band. Also this paper considers spatial multiplexing scheme to serve multi-users with multiple received antennas. Gains of the beamforming and the spatial multiplexing schemes are evaluated by analyzing the spectral efficiency.