• 제목/요약/키워드: Spectrometer

검색결과 2,551건 처리시간 0.031초

광섬유 피드 리트로마운트형 분광계 (AN OPTICAL FIBER FEED LITTROW-MOUNTED SPECTROMETER)

  • 배지훈;송재원;윤태석
    • 천문학논총
    • /
    • 제27권3호
    • /
    • pp.87-93
    • /
    • 2012
  • A low-dispersion fiber feed Littrow-mounted grating spectrometer for education was designed and fabricated. The dispersion element is a reflective type blazed grating Edmundoptics NT 46-075 (spatial frequency 600 lines/mm, dimension $30mm{\times}30mm$, blazed angle 8.6 degree). The optical fiber coupler module for optical guiding from telescope to spectrometer is composed of a multi-mode FC connector - FC connector optical fiber patch cord (core/cladding diameter $50{\mu}m/125{\mu}m$) and two 1.25" throw-tube couplers. The lens for collimating and imaging is a general purpose focal length 50 mm camera lens (f/1.8). The device for optical path control is a rectangular prism (size $25mm{\times}25mm$). The imaging camera sensor is a Meade DSI Pro 2 CCD sensor (black and white, $752{\times}582$ pixels and pixel size $8.3{\mu}m{\times}8.6{\mu}m$). Softwares for data logging and analysis consist of Meade Autostar Suite, NIH imagej and Vernier Logger Pro 3. The wavelength coverage range of the spectrometer is 205 nm at central wavelength 550 nm. The wavelength resolution is 1.7 nm.

Photo Diode Array형의 휴대용 근적외 분광기와 FT 근적외 분광기를 이용한 Hairless Mouse 피부 수분 정량 (Quantification of Skin Moisture in Hairless Mouse by using a Portable NIR System and a FT NIR Spectrometer)

  • 서은정;우영아;김효진
    • 약학회지
    • /
    • 제49권2호
    • /
    • pp.115-121
    • /
    • 2005
  • In this study, the performance of a portable NIR system and a FT NIR spectrometer were compared to determine water content of hairless mouse skin. The stratum corneum parts wer e separated from the epidermal tissues by trypsin solution. NIR diffuse reflectance spectra of hairless mouse skin were acquired using a fiber optic probe. In the near infrared, water molecules show two clear absorption bands at 1450 nm from first overtone of O-H stretching and 1940 nm from the combination involving O-H stretching and O-H deformation. It was found that the variations of O-H absorption band according to water content. Partial least squares regression (PLSR) was applied to develop a calibration model. The PLS model showed a good correlation between NIR predicted value and the absolute water content of separated hairless mouse skin, in vitro. For both the portable and the FT NIR spectrometer, These studies showed the possibility of a rapid and nondestructive skin moisture measurement using NIR spectroscopy. The portable NIR spectrometer with a photodiode arrays-microsensor could be more rapidly applied for the determination of water content with comparable accuracy with the performance of a FT spectrometer .

A Fast Neutron Time-of-Flight Spectrometer with High Resolution

  • Cho, Mann
    • Nuclear Engineering and Technology
    • /
    • 제4권2호
    • /
    • pp.116-131
    • /
    • 1972
  • Li$^{7}$ (p, n) Be$^{7}$ 원자핵반응에서 Li target의 두께와 입사양자의 에너지를 적절히 선정하므로써 1-n sec 파동 Van de Graaff 가속도로부터 keV 영역에서의 연속중성자spectrum을 발생시키고 92% 농축된 5mm 두께의 $B^{10}$ 판과 4개의 4"$\times$3" NaI (T1) 발광체로 이루어진 속중성자검출기를 이용 속중성자 비행시간법에 의한 중성자spectrometer 를 제작하였다. 장치의 에너지 분해능은 50 keV에서 0.3%보다 양호하며 신호대잡음비도 개량되었다. 이를 이용하여 몇가지 분석된 단일동위원소의 전단면적을 측정하고 R-matrix 전자계산 code로 분석하였다. 각 공명에 따르는 스핀식와 공명인수들을 찾아내었다.

  • PDF

대기중 오존측정을 위한 자동측정기의 개발 (A development of an automatic $O_3$ analyzer for ambient air pollution)

  • 정상진;장재철;곽재환;심순섭
    • 한국대기환경학회:학술대회논문집
    • /
    • 한국대기환경학회 2003년도 춘계학술대회 논문집
    • /
    • pp.215-216
    • /
    • 2003
  • 대기환경에 대한 오존의 영향이 증대되면서 오존에 대한 관심이 증대되었다. 이에 따라 대기중 오존 농도를 정확히 측정할 수 있는 오존 측정기에 대한 관심도 고조되고 있는 실정이다. 오존을 측정하기 위한 방법은 분석하는 방법에 따라 Ion Chromatography, UV/Vis Spectrometer, Spectrofluorimeter, Spectrometer(reflection)방법 등을 들 수 있으며(Zhou and Smith, 1997, Geyh etal. 1997), 이들 중 Spectrometer(reflection)를 이용하는 방법이 비교적 간단하다. 이 방법은 대기 중 오존과 반응하여 색도가 변화하는 착색제를 사용하여 색도 변화를 관측하여 오존 농도를 평가하는 방법이다. (중략)

  • PDF

Single-Beam을 이용한 광음향 분광법에 관한 연구 (A Study on Single-Beam Photoacoustic Spectroscopy)

  • 김중환
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1984년도 추계학술발표회 논문집
    • /
    • pp.33-35
    • /
    • 1984
  • A new type single beam photoacoustic spectrometer suitable for measuring optical absorption of condensed powder matter with the automatic calibration capability of a source power spectrum is introduced. The signal processing until of this spectrometer consists of a photoacoustic cell a lock-in amp., a switching circuit and a personal computer. The measured optical absorption spectra of a few material by this method are good agreement with the results obtained by the double-beam photoacoustic spectrometer.

  • PDF

Aerosol Mass Spectrometer (AMS)-Based Real-Time Physicochemical Characterization of Atmospheric Aerosols

  • Kim, Donghwi
    • Mass Spectrometry Letters
    • /
    • 제13권2호
    • /
    • pp.27-34
    • /
    • 2022
  • Atmospheric aerosols have become a major environmental concern because of their adverse effects on human health, air quality, and climate change. Over the last few decades, several mass spectrometry (MS)-based techniques have been developed and applied in the field of atmospheric aerosol research. Particularly, real-time measurement of ambient aerosols using an aerosol mass spectrometer (AMS) has become one of the most powerful tools for aerosol chemistry. This review provides a brief description of AMS and its applications for understanding the physicochemical properties of atmospheric aerosols, as well as its sources and evolution processes.

바사분광분석장치에 관한 연구 (Construction and Test of a Reflectance Spectrometer)

  • 황훈;정동승
    • 대한화학회지
    • /
    • 제44권4호
    • /
    • pp.316-321
    • /
    • 2000
  • 분광분석장치의 구성성분들인 광원과 광 검출기를 cell을 중심으로 은쪽에배열하여 제작한 반사분광분석장치를 제작하였으며, 이러한 분사분광분석장치가 액체시료에 대한 흡수분광분석에 사용될 수 있는지를 알아보았다. 이를 위해 $Cu^{2+}$이온의 표준용액들을 대상으로 반사분광분석장치와 기존의 흡수분광분석장치를 대표하는'Spectronic 20' 성능을 비교한 결과, $1.0{\times}10^{-4}$M~$1.00{\times}10^{-1}$M 농도 범위에서 반사분석장치는 'Spectronic 20'에 비해 더 높은 감도를 나타내었다.

  • PDF

복합분광분석장치를 사용한 반사분광분석과 흡수분광분석의 비교 (Comparison of the Reflectance and the Absoription Spectrometries Using the Combined Spectrometer)

  • 황훈;정세희;이경수
    • 대한화학회지
    • /
    • 제45권1호
    • /
    • pp.45-50
    • /
    • 2001
  • 흡수분광분석장치와 반사분광분석장치가 결합된 형태의 복합분광분석장치를 제작하여 흡수분광분석과 반사분광분석의 성능을 서로 비교하였다. $Cu^{2+}$이온표준용액과 $Co^{2+}$이온표준용액들을 사용한 실험결과에 의하면, 분석대상성분의 농도가 너무 묽은 경우나 분석대상성분의 몰흡광계수가 충분히 크지 않은 경우와 같이 기존의 흡수분광분석으로는 정량분석이 힘든 시료용액에 대한 분광분석에 용이하게 적용될 수 있다는 사실을 확인하였다.

  • PDF

Picosecond Absorption Kinetic Spectrometer with a Laser and a Streak Camera

  • Jang, Du-Jeon
    • 한국광학회:학술대회논문집
    • /
    • 한국광학회 1990년도 제5회 파동 및 레이저 학술발표회 5th Conference on Waves and lasers 논문집 - 한국광학회
    • /
    • pp.172-176
    • /
    • 1990
  • A high resolution picosecond absorption kinetic spectrometer utilizing dye emission and a streak camera is presented and compared with other methods of picosecond transient absorption measurements. Typical transient absorption and bleach recovery kinetics measured with this spectrometer are shown. Single wavelength transient absorption or ground state bleach recovery kinetics are determined on the basis of a single laser shot, so that the samples are relatively free frm decomposition by irradiation. Excellent kinetics may be obtained from the near UV to the near IR and are not subject to interference from luminescence of samples. The sensitivity of this spectrometer is very high and it is reasonably easy and convenient to set up and use.

  • PDF

Benchmark Results of a Radio Spectrometer Based on Graphics Processing Unit

  • Kim, Jongsoo;Wagner, Jan
    • 천문학회보
    • /
    • 제40권2호
    • /
    • pp.44.1-44.1
    • /
    • 2015
  • We set up a project to make spectrometers for single dish observations of the Korean VLBI Network (KVN), a new future multi-beam receiver of the ASTE (Atacama Submillimeter Telescope Experiment), and the total power (TP) antennas of the Atacama Large Millimeter/submillimeter Array (ALMA). Traditionally, spectrometers based on ASIC (Application-Specific Integrated circuit) and FPGA (Field-Programmable Gate Array) have been used in radio astronomy. It is, however, that a Graphics Processing Unit (GPU) technology is now viable for spectrometers due to the rapid improvement of its performance. A high-resolution spectrometer should have the following functions: poly-phase filter, data-bit conversion, fast Fourier transform, and complex multiplication. We wrote a program based on CUDA (Compute Unified Device Architecture) for a GPU spectrometer. We measured its performance using two GPU cards, Titan X and K40m, from NVIDIA. A non-optimized GPU code can process a data stream of around 2 GHz bandwidth, which is enough for the KVN spectrometer and promising for the ASTE and ALMA TP spectrometers.

  • PDF