• 제목/요약/키워드: Spectral sensitivity

검색결과 219건 처리시간 0.027초

Theoretical Analysis and Optimization of Extrinsic Fabry-Perot Interferometer Optical-fiber Humidity-sensor Structures

  • Yin, Xiao Lei;Wang, Ning;Yu, Xiao Dan;Li, Yu Hao;Zhang, Bo;Li, Dai Lin
    • Current Optics and Photonics
    • /
    • 제5권6호
    • /
    • pp.652-659
    • /
    • 2021
  • The theoretical analysis and optimization of extrinsic Fabry-Perot interferometer (EFPI) opticalfiber humidity sensors are deeply investigated. For a typical dual-cavity structure composed of an optical fiber and a humidity-sensitive membrane (HSM), the changes in refractive index (RI) and initial length are discussed for polymer materials and porous oxide materials when relative humidity (RH) increases. The typical interference spectrum is simulated at different RH using MATLAB. The spectral change caused by changing HSM RI and initial length are simulated simutineously, showing different influences on humidity response. To deeply investigate the influence on RH sensitivity, the typical response sensitivity curves for different HSM lengths and air-cavity lengths are simulated. The results show that the HSM is the vital factor. Short HSM length can improve the sensitivity, but for HSM RI and length the influences on sensitivity are opposite, because of the opposite spectral-shift trend. Deep discussion and an optimization method are provided to solve this problem. According to analysis, an opaque HSM is helpful to improve sensitivity. Furthermore, if using an opaque HSM, a short air cavity and long HSM length can improve the sensor's sensitivity These results provide deep understanding and some ideas for designing and optimizing highly sensitive EFPI fiber humidity sensors.

적외선 영상기법에 의한 CCD 센서의 스펙트럼 응답 특성 분석 기법 (Apparatus and method for analysing spectral response of a CCD optical sensor using an infrared imaging technique)

  • 강성준;나철훈;박순영
    • 전자공학회논문지SC
    • /
    • 제43권3호
    • /
    • pp.25-30
    • /
    • 2006
  • 디지털 영상처리를 이용해 CCD 센서의 스펙트럼 응답특성을 직접 측정할 수 있는 적외선 영상기법을 제안하고 있다. 이 방법은 쉽고 경제적인 방법으로 상용 CCD 센서의 스펙트럼 감도를 검출할 수 있도록 한다. 본 장치의 핵심 부품은 단색광원기, CCD 지지대, 디지털 영상처리 시스템이 내장된 컴퓨터이다. 방법의 타당성을 증명하기 위해 상용 CCD 카메라에 대해 시험적으로 행한 실험은 이론적인 모델과 잘 일치함을 보여 주었다.

LED 광원에 대한 암순응시 볼락 (Sebastes inermis)의 시각 스펙트럼 민감도 (Visual spectral sensitivity of dark-adapted rockfish (Sebastes inermis) in LED light source)

  • 허민아;강경미;신현옥
    • 수산해양기술연구
    • /
    • 제51권1호
    • /
    • pp.102-110
    • /
    • 2015
  • The characteristics of aquatic light fields are generally reflected in the visual systems of fishes inhabiting them. Therefore, research on light sensitivity of fish is useful to explain the correlation between the visual function and habitat, behavior and distribution of fish. Rockfish is an important species in coastal ecology and also one of the main species for culturing in Korea. To make a contribution on the maintenance of the fish resources and understanding the ecology of the rockfish, the visual spectral sensitivities of the dark-adapted rockfishes were measured in the range of visible light (405~660 nm) using a light source of light-emitting diodes (LEDs). In order to assess electrophysiological response of the fish, the ERGs (electroretinograms) of the dark-adapted rockfishes were recorded on a data logger (12 bits) and a laptop computer. Juvenile (n=5; weight: $20.3{\pm}5.2g$; total length: $10.3{\pm}0.7cm$) and adult (n=5; weight: $87.8{\pm}21.8g$; total length: $18.1{\pm}1.3cm$) rockfishes were used in experiment. The visual threshold of juvenile and adult rockfish were 11.66 (log quanta/$cm^2/s$) and 11.81 (log quanta/$cm^2/s$) in 574 nm, respectively. The peak wavelength of the spectral sensitivity in the dark-adapted juvenile and adult rockfish was commonly 551 nm (series of green color). Collectively, these results demonstrate that the rockfish has suitable visual capabilities for inhabiting coastal water in Korea.

CMOS 이미지 센서용 n-p-n-p 적층형 색 검출기 (The n-p-n-p layer stacked color detector for CMOS image sensor)

  • 송영선;윤일구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 하계학술대회 논문집 Vol.6
    • /
    • pp.72-73
    • /
    • 2005
  • In this paper, the simulation of the n-p-n-p layer stacked color detector is presented. A color detector based on vertically integrated structures of silicon can overcome color moire or color aliasing effect. The color detector is designed to separate the fundamental chromatic components at each junction and exhibits maxima of the spectral sensitivity at red, green, and blue region, respectively. From this result, it is observed that the spectral response can be controlled by the doping concentration and structure of the devices.

  • PDF

소형 칼라미터의 개발에 관한 연구 (Development of a Portable Colorimeter)

  • 김재형;황정연;서대식
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.328-331
    • /
    • 2001
  • Color simulation on a portable colorimeter was performed to distinguish quantitatively a chromaticity coordinates on a color guide of a urine strips by using the spectral power distribution of chip LED, the spectral reflectance of printed objects, and the spectral sensitivity of photodiode. The CIE tristimulus values and chromaticity coordinates realized by a colorimeter were modified to be conformable with real color reactions. Experimental results showed a real color in comparison with those obtained by Colorimeter CM2C(Color Savvy).

  • PDF

요분석 스트립의 정색반응에 대한 색도좌표 보정 (The Compensation of Chromaticily Coordinates on Primary Color Reaction of Urine Strips)

  • 김재형;조진욱;남상희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2001년도 추계학술대회 논문집
    • /
    • pp.320-323
    • /
    • 2001
  • A computer simulation was performed to distinguish quantitatively a color reaction in a urine analysis systems by using the spectral power distribution of LEDs, the spectral reflectance of a urine strip, and the spectral sensitivity of photodiode. The CIE tristimulus values and CIE chromaticity coordinates ware modified to be conformable with real color reactions in a urine strips. Results on color simulation showed a of real color in comparison with those obtained by Colorimeter CM2C(Color Savvy).

  • PDF

POST-LAUNCH RADIOMETRIC CALIBRATION OF KOMPSAT2 HIGH RESOLUTION IMAGE

  • Yoon, Jong-Suk;Lee, Kyu-Sung;Chi, Jun-Hwa;Lee, Dong-Han
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2006년도 Proceedings of ISRS 2006 PORSEC Volume I
    • /
    • pp.402-405
    • /
    • 2006
  • Radiometric calibration of optical image data is necessary to convert raw digital number (DN) value of each pixel into a physically meaningful measurement (radiance). To extract rather quantitative information regarding biophysical characteristics of the earth surface materials, radiometric calibration is often essential procedure. A sensor detects the radiation of sunlight interacted atmospheric constituents. Therefore, the amount of the energy reaching at the sensor is quite different from the initial amount reflected from the surface. To achieve the target reflectance after atmospheric correct, an initial step is to convert DN value to at-sensor radiance. A linear model, the simplest radiometric model, is applied to averaged spectral radiance for this conversion. This study purposes to analyze the sensitivity of several factors affecting on radiance for carrying out absolute radiometric calibration of panchromatic images from KOMPSAT2 launched at July, 2006. MODTRAN is used to calculate radiance at sensor and reflectance of target is measured by a portable spectro-radiometer at the same time the satellite is passing the target for the radiometric calibration. As using different contents of materials composing of atmosphere, the differences of radiance are investigated. Because the spectral sensitivity of panchromatic images of KOMPSAT2 ranges from 500 to 900 nm, the materials causing scattering in visible range are mainly considered to analyze the sensitivity. According to the verified sensitivity, direct measurement can be recommenced for absolute radiometric calibration.

  • PDF

Mid-Span Spectral Inversion 기법을 채택한 장거리 광 전송 시스템에서의 증폭기 간격에 따른 비트 에러율 (Bit Error Rate Dependence on Amplifier Spacing in Long-Haul Optical Transmission System with Mid-Span Spectral Inversion)

  • 이성렬
    • 한국항행학회논문지
    • /
    • 제9권2호
    • /
    • pp.109-120
    • /
    • 2005
  • 본 논문에서는 MSSI 보상 기법을 채택한 1,200 km의 WDM 전송 시스템에서의 비트 에러율, 수신 감도, 입사 전력 최소 허용치를 증폭기 간격에 따라 수치적으로 살펴보았다. 변조 파형 형식에 관계없이 수신 감도와 입사 전력 최소 허용치 모두 증폭기 간격이 증가할수록 나빠지는 것을 알 수 있었다. 수신 감도 측면에서는 NRZ 전송보다 RZ 전송을 하는 경우 감도를 개선할 수 있었지만 실제 입사 전력 허용치 면에서는 NRZ가 RZ 전송보다 유리한 것을 확인하였다. 아울러 증폭기 간격을 50 km 이하로 해야만 수신 감도와 입사 전력 최소 허용치 모두 분산 계수, 채널 파장, 펌프광 전력에 비교적 영향을 적게 받는 것을 확인할 수 있었다.

  • PDF

Initial-phase Sensitivity Analysis of Harmonic Measurements via Windowed DFT

  • Song, Shuping;Wang, Fuzong;Cheng, Guozhu
    • Transactions on Electrical and Electronic Materials
    • /
    • 제15권4호
    • /
    • pp.182-188
    • /
    • 2014
  • When the windowed DFT algorithm is applied in harmonic measurements, the problem of initial-phase sensitivity will be encountered, this has an effect on harmonic amplitude accuracy. In this paper, the origin of initial-phase sensitivity is analyzed and the main factors that influence the level of initial-phase sensitivity are demonstrated. A method of reducing initial-phase sensitivity is proposed to increase the stability of harmonic measurements. We found that initial-phase sensitivity is determined by the side lobe peak level of the window functions when synchronous deviation is fixed. In addition, increasing the length of the time recorded can be used to remove initial-phase sensitivity. The correctness and validity of our conclusions have been confirmed through numerical results and field tests.

Mid-Span Spectral Inversion 기법을 채택한 장거리 광 전송 시스템에서의 비트 에러율 평가 (Evaluation of Bit Error Rate of a Long-Haul Optical Transmission System adopted the Mid-Span Spectral Inversion Method)

  • 이성렬;김남성;방효창
    • 한국항행학회논문지
    • /
    • 제6권3호
    • /
    • pp.223-230
    • /
    • 2002
  • 본 논문에서는 MSSI 보상 기법을 채택한 2,000km 광 전송 시스템의 수신 성능 평가를 위해 신호간의 간섭 영향을 고려한 직접 검파 수신단에서의 잡음 전력과 비트 에러율을 도출하고, 비트율에 따른 수신 감도를 계산해 보았다. 본 논문에서 제안한 BER 계산이 실제 시스템에 적용될 수 있는 방법이라는 것을 확인할 수 있었고, 전송 링크에 MSSI 보상 기법이 적용된 시스템에서 신호 파형의 색 분산과 비선형 효과에 의한 왜곡이 보상되지만, 결국 비트율이 높아질수록 좁아지는 비트 간격에 따른 ISI에 의해 평균 수신 전력의 감소를 가져오고 궁극적으로 수신 감도를 감소시켜 준다는 것을 확인할 수 있었다.

  • PDF