• 제목/요약/키워드: Spectral range

검색결과 948건 처리시간 0.031초

The Analysis on the relation between the Compression Method and the Performance of MSC(Multi-Spectral Camera) Image data

  • Yong, Sang-Soon;Choi, Myung-Jin;Ra, Sung-Woong
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2007년도 Proceedings of ISRS 2007
    • /
    • pp.530-532
    • /
    • 2007
  • Multi-Spectral Camera(MSC) is a main payload on the KOMPSAT-2 satellite to perform the earth remote sensing. The MSC instrument has one(1) channel for panchromatic imaging and four(4) channel for multi-spectral imaging covering the spectral range from 450nm to 900nm using TDI CCD Focal Plane Array (FPA). The compression method on KOMPSAT-2 MSC was selected and used to match EOS input rate and PDTS output data rate on MSC image data chain. At once the MSC performance was carefully handled to minimize any degradation so that it was analyzed and restored in KGS(KOMPSAT Ground Station) during LEOP and Cal./Val.(Calibration and Validation) phase. In this paper, on-orbit image data chain in MSC and image data processing on KGS including general MSC description is briefly described. The influences on image performance between on-board compression algorithms and between performance restoration methods in ground station are analyzed and discussed.

  • PDF

식물묘공장의 근접조명용 인공광원으로서 형광등의 광강도 및 분광 특성 (Light Intensity and Spectral Characteristics of Fluorescent Lamps as Artificial Light Source for Close illumination in Transplant Production Factory)

  • 김용현;이종호
    • Journal of Biosystems Engineering
    • /
    • 제23권6호
    • /
    • pp.591-598
    • /
    • 1998
  • Light intensity and spectral characteristics of different types of fluorescent lamps were tested to investigate their possibility as the artificial lighting sources for the close illumination applied in the transplant production factory. Photosynthetic photon flux densitiy(PPF), illuminance and irradiance for all lamps decreased logarithmically with an increase of the vertical distance from the lighting source. The fluorescent lamp specially designed plant growth (PG lamp) showed a maximum spectral irradiance at the wavelength of 660nm. However, it showed lower irradiance than that of a standard fluorescent lamp at the range of wavelength between 500 and 600nm. On the other hand, PG lamp showed higher PPF and lower illuminance than those of the standard fluorescent lamp. The maximum peak of spectral characteristics for both of the single and twin three-bind fluorescent lamps was shorn at the wavelength of 545m and the next peaks were shown at the wavelength of 610nm and 435nm, respectively. Since the red fluorescent lamp has a narrower peak at the wavelength of 660nm, it may be useful for the supplementary red lighting. For three of standard, single three-band and twin three-band fluorescent lamps, the values of conversion factor for converting illuminance to PPF fell within the narrow range from 76 to 791x/$\mu$molㆍm$^{-2}$ ㆍs$^{-l}$ . However, for PG lamp, it was 29.71x/$\mu$molㆍm$^{-2}$ ㆍs$^{-1}$. Also, the values of conversion factor for converting PPF to irradiance of fluorescent lamp used in this study ranged between 4.85 and 5.34$\mu$molㆍm$^{-2}$ ㆍs$^{-1}$/Wㆍm$^{-2}$ .

  • PDF

Feasibility Study for an Optical Sensing System for Hardy Kiwi (Actinidia arguta) Sugar Content Estimation

  • Lee, Sangyoon;Sarkar, Shagor;Park, Youngki;Yang, Jaekyeong;Kweon, Giyoung
    • 농업생명과학연구
    • /
    • 제53권3호
    • /
    • pp.147-157
    • /
    • 2019
  • In this study, we tried to find out the most appropriate pre-processing method and to verify the feasibility of developing a low-price sensing system for predicting the hardy kiwis sugar content based on VNIRS and subsequent spectral analysis. A total of 495 hardy kiwi samples were collected from three farms in Muju, Jeollabukdo, South Korea. The samples were scanned with a spectrophotometer in the range of 730-2300 nm with 1 nm spectral sampling interval. The measured data were arbitrarily separated into calibration and validation data for sugar content prediction. Partial least squares (PLS) regression was performed using various combinations of pre-processing methods. When the latent variable (LV) was 8 with the pre-processing combination of standard normal variate (SNV) and orthogonal signal correction (OSC), the highest R2 values of calibration and validation were 0.78 and 0.84, respectively. The possibility of predicting the sugar content of hardy kiwi was also examined at spectral sampling intervals of 6 and 10 nm in the narrower spectral range from 730 nm to 1200 nm for a low-price optical sensing system. The prediction performance had promising results with R2 values of 0.84 and 0.80 for 6 and 10 nm, respectively. Future studies will aim to develop a low-price optical sensing system with a combination of optical components such as photodiodes, light-emitting diodes (LEDs) and/or lamps, and to locate a more reliable prediction model by including meteorological data, soil data, and different varieties of hardy kiwi plants.

스펙트럴 포물선 방정식 법을 이용한 수중음파 전달해석 (Analysis of Acoustic Propagation using Spectral Parabolic Equation Method)

  • 김국현;성우제
    • 한국음향학회지
    • /
    • 제15권2호
    • /
    • pp.72-78
    • /
    • 1996
  • 본 논문에서는 2차원 양방향 포물선 방정식 법과 푸리에 변환을 이용하여 3차원 굴절현상 및 3차원 후방 산란파를 포함하는 $2\frac12$차원 문제를 푸는 방법에 대해 다루었다. 여기서 $2\frac12$ 차원 문제란 2차원적 해양환경 하에 3차원적 음원이 존재할 경우를 의미한다. 2차원 양방향 포물선 방정식법은 수치기법으로 깊이 방향과 수평거리 방향에 대해 각각 Galerkin법과 Crank-Nicolson법을 사용하며 수직 불연속 경계면에 의한 후방 산란파를 포함한 수평거리 의존 문제에 대해 유용한 해를 제공한다. 2차원 해양환경에서는 파수 k가 종 또는 횡 수평거리 방향과 깊이 방향에 대한 함수이므로 3차원 Helmholtz방정식 법을 이용해 스펙트럴 해를 구하여 다시 푸리에 역변환하면 최종 해를 구할 수 있다. 본 연구방법의 정확성을 시험하기 위해서 계단형 해저면을 갖는 간단한 해양환경에서 계산을 수행해 보았으며 대한해협의 특정지역에서의 3차원적 음파전달 특성을 살펴보았다.

  • PDF

IGRINS Spectral Library

  • Park, Sunkyung;Lee, Jeong-Eun;Kang, Wonseok;Lee, Sang-Gak;Chun, Moo-Young;Kim, Kang-Min;Yuk, In-Soo;Lee, Jae-Joon;Mace, Gregory N.;Kim, Hwihyun;Kaplan, Kyle F.;Jaffe, Daniel T.
    • 천문학회보
    • /
    • 제41권2호
    • /
    • pp.43.3-43.3
    • /
    • 2016
  • We present a library of high-resolution (R~45,000) and high signal-to-noise ratio ($S/N{\geq}200$) near-infrared spectra of 147 standard stars. High quality spectra were obtained with Immersion GRating INfrared Spectrograph (IGRINS) covering the full range of H ($1.496-1.795{\mu}m$) and K ($2.080-2.460{\mu}m$) bands. The targets are mainly selected as MK standard stars which have well-defined spectral types and luminosity classes, and cover a wide range of effective temperatures and surface gravities. The spectra were corrected for telluric absorption lines and absolute flux calibrated using Two Micron All Sky Survey (2MASS) photometry. We find new spectral indices in H and K bands and provide their EWs. We describe empirical relations between the measured EWs and stellar atmosphere parameters such as effective temperature and surface gravity.

  • PDF

근전도 power spectrum을 이용한 만성근육동통 환자에 있어서의 저작근 피로에 관한 연구 (EMG Power Spectral Analysis on Masticatory Muscle Fatigue in Chronic Muscle Pain Patients)

  • 이채훈;김영구;임형순
    • Journal of Oral Medicine and Pain
    • /
    • 제22권1호
    • /
    • pp.145-155
    • /
    • 1997
  • The purpose of this study was to compare differences in endurance time and EMG power spectral characteristics of the masticatory muscles during sustained isometric contraction between patients and controls. 15 CMD patients{8 women and 7 men, aged 15 to 38 years(24.1$\pm$7.5)}, and 15 healthy volunteers{8 women and 7 men, aged 15 to 30 years(24.7$\pm$3.4)} without past history or present symptoms of CMD were included in this study. Sustained isometric contractions of masticatory muscles were perfomeed as long as possible at 50% level of maximum voluntary contraction(MVC) of EMG activity via visual feedback, and the duration of sustained isometric contraction(endurance time) was examined. The author perfomed EMG power spectral analysis in the myoelectric signals of masseter and anterior temporal muscle during sustained isometric contraction in CMD patients with chronic muscle pain and healthy controls. The author came to following conclusions from the results. 1. The endurance time of the patient group was shorter than the control group in sustained isometric contraction of masticatory muscles(p<0.01). 2. MF values of masticatory muscles with sustained isometric contraction during endurance time were decreased following regression line in both groups(p<0.01, r>0.9). 3. The amount of MF shift to lower frequency range exhibited no significant differences between the patients and the control group in sustained isometric contraction during endurance time. 4. SMF to lower frequency range of the patient group was steeper than the control group in sustained isometric contraction during endurance time(p<0.05).

  • PDF

Fast Analysis of Film Thickness in Spectroscopic Reflectometry using Direct Phase Extraction

  • Kim, Kwangrak;Kwon, Soonyang;Pahk, Heui Jae
    • Current Optics and Photonics
    • /
    • 제1권1호
    • /
    • pp.29-33
    • /
    • 2017
  • A method for analysis of thin film thickness in spectroscopic reflectometry is proposed. In spectroscopic reflectometry, there has been a trade-off between accuracy and computation speed using the conventional analysis algorithms. The trade-off originated from the nonlinearity of spectral reflectance with respect to film thickness. In this paper, the spectral phase is extracted from spectral reflectance, and the thickness of the film can be calculated by linear equations. By using the proposed method, film thickness can be measured very fast with high accuracy. The simulation result shows that the film thickness can be acquired with high accuracy. In the simulation, analysis error is lower than 0.01% in the thickness range from 100 nm to 4 um. The experiments also show good accuracy. Maximum error is under $40{\AA}$ in the thickness range $3,000-20,000{\AA}$. The experiments present that the proposed method is very fast. It takes only 2.6 s for volumetric thickness analysis of 640*480 pixels. The study suggests that the method can be a useful tool for the volumetric thickness measurement in display and semiconductor industries.

Enhance photoelectric efficiency of PV by optical-thermal management of nanofilm reflector

  • Liang, Huaxu;Wang, Baisheng;Su, Ronghua;Zhang, Ao;Wang, Fuqiang;Shuai, Yong
    • Advances in nano research
    • /
    • 제13권5호
    • /
    • pp.475-485
    • /
    • 2022
  • Crystalline silicon photovoltaic cells have advantages of zero pollution, large scale and high reliability. A major challenge is that sunlight wavelength with photon energy lower than semiconductor band gap is converted into heat and increase its temperature and reduce its conversion efficiency. Traditional cooling PV method is using water flowing below the modules to cool down PV temperature. In this paper, the idea is proposed to reduce the temperature of the module and improve the energy conversion efficiency of the module through the modulation of the solar spectrum. A spectrally selective nanofilm reflector located directly on the surface of PV is designed, which can reflect sunlight wavelength with low photon energy, and even enhance absorption of sunlight wavelength with high photon energy. The results indicate that nanofilm reflector can reduce spectral reflectivity integral from 9.0% to 6.93% in 400~1100 nm wavelength range, and improve spectral reflectivity integral from 23.1% to 78.34% in long wavelength range. The nanofilm reflector can reduce temperature of PV by 4.51℃ and relatively improved energy conversion efficiency of PV by 1.25% when solar irradiance is 1000 W/m2. Furthermore, the nanofilm reflector is insensitive in sunlight's angle and polarization state, and be suitable for high irradiance environment.

A Survey of Fusion Techniques for Multi-spectral Images

  • Achalakul, Tiranee
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2002년도 ITC-CSCC -2
    • /
    • pp.1244-1247
    • /
    • 2002
  • This paper discusses various algorithms to the fusion of multi-spectral image. These fusion techniques have a wide variety of applications that range from hospital pathology to battlefield management. Different algorithms in each fusion level, namely data, feature, and decision are compared. The PCT-Based algorithm, which has the characteristic of data compression, is described. The algorithm is experimented on a foliated aerial scene and the fusion result is presented.

  • PDF

사진유제용 분광증감색소의 용매에 대한 안정성 (A Stability on the Solvents of Spectral Sensitizer for Photographic Emulsion)

  • 김영찬
    • 한국응용과학기술학회지
    • /
    • 제14권2호
    • /
    • pp.65-70
    • /
    • 1997
  • The symmetric naphthothiazolo carbocyanine is of industrial importance as red-sensitizing dye in the spectral sensitization of emulsion microcrystals in negative film-making. The stability on the solvents of naphthothiazolo carbocyanine dye was measured by UV-Vis spectrophotometer, and then all of solvents were stabilized sensitizer. The maximum absorption peak range in various solvents was $600nm{\sim}612nm$. But it was identified that only methanol can be used to photographic emulsion.