• 제목/요약/키워드: Spectral range

검색결과 948건 처리시간 0.026초

IDENTIFICATION OF FALSIFIED DRUGS USING NEAR-INFRARED SPECTROSCOPY

  • Scafi, Sergio H.F.;Pasquini, Celio
    • 한국근적외분광분석학회:학술대회논문집
    • /
    • 한국근적외분광분석학회 2001년도 NIR-2001
    • /
    • pp.3112-3112
    • /
    • 2001
  • Near-Infrared Spectroscopy (NIRS) was investigated aiming at the identification of falsified drugs. The identification is based on comparison of the NIR spectrum of a sample with a typical spectra of an authentic drug using multivariate modelling and classification algorithms (PCA/SIMCA). Two spectrophotometers (Brimrose - Luminar 2000 and 2030), based on acoustic-optical filter (AOTF) technology, sharing the same controlling computer, software (Brimrose - Snap 2.03) and the data acquisition electronics, were employed. The Luminar 2000 scans the range 850 1800 nm and was employed for transmitance/absorbance measurements of liquids with a transflectance optical bundle probe with total optical path of 5 mm and a circular area of 0.5 $\textrm{cm}^2$. Model 2030 scans the rage 1100 2400 nm and was employed for reflectance measurement of solids drugs. 300 spectra, acquired in about 20 s, were averaged for each sample. Chemometric treatment of the spectral data, modelling and classification were performed by using the Unscrambler 7.5 software (CAMO Norway). This package provides the Principal Component Analysis (PCA) and SIMCA algorithms, used for modelling and classification, respectively. Initially, NIRS was evaluated for spectrum acquisition of various drugs, selected in order to accomplish the diversity of physico-chemical characteristics found among commercial products. Parameters which could affect the spectra of a given drug (especially if presented as solid tablets) were investigated and the results showed that the first derivative can minimize spectral changes associated with tablet geometry, physical differences in their faces and position in relation to the probe beam. The effect of ambient humidity and temperature were also investigated. The first factor needs to be controlled for model construction because the ambient humidity can cause spectral alterations that should cause the wrong classification of a real drug if the factor is not considered by the model.

  • PDF

A Melon Fruit Grading Machine Using a Miniature VIS/NIR Spectrometer: 1. Calibration Models for the Prediction of Soluble Solids Content and Firmness

  • Suh, Sang-Ryong;Lee, Kyeong-Hwan;Yu, Seung-Hwa;Shin, Hwa-Sun;Choi, Young-Soo;Yoo, Soo-Nam
    • Journal of Biosystems Engineering
    • /
    • 제37권3호
    • /
    • pp.166-176
    • /
    • 2012
  • Purpose: This study was conducted to investigate the potential of interactance mode of NIR spectroscopy technology for the estimation of soluble solids content (SSC) and firmness of muskmelons. Methods: Melon samples were taken from local greenhouses in three different harvesting seasons (experiments 1, 2, and 3). The fruit attributes were measured at the 6 points on an equator of each sample where the spectral data were collected. The prediction models were developed using the original spectral data and the spectral data sets preprocessed by 20 methods. The performance of the models was compared. Results: In the prediction of SSC, the highest coefficient of determination ($R_{cv}{^2}$) values of the cross-validation was 0.755 (standard error of prediction, SEP=$0.89^{\circ}Brix$) with the preprocessing of normalization with range in experiment 1. The highest coefficient of determination in the robustness tests, $R_{rt}{^2}$=0.650 (SEP=$1.03^{\circ}Brix$), was found when the best model of experiment 3 was evaluated with the data set of experiment 2. The best $R_{cv}{^2}$ for the prediction of firmness was 0.715 (SEP=3.63 N) when no preprocessing was applied in experiment 1. The highest $R_{rt}{^2}$ was 0.404 (SEP=5.30 N) when the best model of experiment 3 was applied to the data set of experiment 1. Conclusions: From the test results, it can be concluded that the interactance mode of VIS/NIR spectroscopy technology has a great potential to measure SSC and firmness of thick-skinned muskmelons.

광원 및 디스플레이 기기의 색특성 측정의 불확도 평가 (Uncertainty Evaluation of Color Measurement on Light Sources and Display Devices)

  • 박성종;이동훈;김용완;박승남
    • 한국광학회지
    • /
    • 제20권2호
    • /
    • pp.110-117
    • /
    • 2009
  • 본 논문은 광원 및 디스플레이 기기의 중요한 품질 지표 중 하나인 색특성 측정과 관련하여 대표적인 측정량인 CIE 1931(x, y) 색좌표, CIE 1960(u, v) 색좌표, 상관색온도(correlated color temperature, CCT), 분포온도(distribution temperature)에 대한 측정불확도 평가방법과 그 산출 예를 소개한다. 분광복사계를 사용하여 광원의 상대분광분포를 측정하고 이로부터 위의 색특성 측정량을 계산하는 경우에 대하여 표준소급체계를 소개하고, 상대분광분포의 불확도가 각 색특성 측정량의 불확도로 전파되는 과정을 파장간 상관관계를 고려한 행렬식을 이용하여 일관되게 유도한 후, CIE A 표준광원, LED 백색광, LCD 백색광에 대해 측정불확도 산출 예를 보였다.

Unbiased spectroscopic study of the Cygnus Loop with LAMOST

  • Seok, Ji Yeon;Koo, Bon-Chul;Zhao, Gang
    • 천문학회보
    • /
    • 제43권1호
    • /
    • pp.44.1-44.1
    • /
    • 2018
  • We present a spectroscopic study of the Galactic supernova remnant (SNR) Cygnus Loop using the fifth Data Release (DR5) of LAMOST. The LAMOST (Large Sky Area Multi-Object Fiber Spectroscopic Telescope) features both a large field-of-view (about 20 deg2) and a large aperture (~4 m in diameter), which allow us to obtain 4000 spectra simultaneously. Its wavelength coverage ranges from ${\sim}3700{\AA}$ to $9000{\AA}$ with a spectral resolution of $R{\approx}1800$. The Cygnus Loop is a prototype of middle-aged SNRs, which has advantages of being bright, large in angular size (${\sim}3.8^{\circ}{\times}3^{\circ}$), and relatively unobscured by dust. Along the line of sight of the Cygnus Loop, 2747 LAMOST DR5 spectra are found in total, which are spatially distributed over the entire remnant. Among them, 778 spectra are selected based on the presence of emission lines (i.e., [O III]${\lambda}5007$, Ha, and [S II]${\lambda}{\lambda}$ 6717, 6731) for further visual inspection. About half of them (336 spectra) show clear spectral features to confirm their association with the remnant, 370 spectra show stellar features only, and 72 spectra are ambiguous and need further investigation. For those associated with the remnant, we identify emission lines and measure their intensities. Spectral properties considerably vary within the remnant, and we compare them with theoretical models to derive physical properties of the SNR such as electron density and temperature, and shock velocity. While some line ratios are in good agreement with model prediction, others cannot be explained by simple shock models with a range of shock velocities. We discuss these discrepancies between model predictions and the observations and finally highlight the powerfulness of the LAMOST data to investigate spatial variations of physical properties of the Cygnus Loop.

  • PDF

Energy-band model on photoresponse transitions in biased asymmetric dot-in-double-quantum-well infrared detector

  • 신현욱;최정우;김준오;이상준;노삼규;이규석
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2010년도 제39회 하계학술대회 초록집
    • /
    • pp.234-234
    • /
    • 2010
  • The PR transitions in asymmetric dot-in-double-quantum-well (DdWELL) photodetector is identified by bias-dependent spectral behaviors. Discrete n-i-n infrared photodetectors were fabricated on a 30-period asymmetric InAs-QD/[InGaAs/GaAs]/AlGaAs DdWELL wafer that was prepared by MBE technique. A 2.0-monolayer (ML) InAs QD ensemble was embedded in upper combined well of InGaAs/GaAs and each stack is separated by a 50-nm AlGaAs barrier. Each pixel has circular aperture of 300 um in diameter, and the mesa cell ($410{\times}410\;{\mu}m^2$) was defined by shallow etching. PR measurements were performed in the spectral range of $3{\sim}13\;{\mu}m$ (~ 100-400 meV) by using a Fourier-transform infrared (FTIR) spectrometer and a low-noise preamplifier. The asymmetric photodetector exhibits unique transition behaviors that near-/far-infrared (NIR/FIR) photoresponse (PR) bands are blue/red shifted by the electric field, contrasted to mid-infrared (MIR) with no dependence. In addition, the MIR-FIR dual-band spectra change into single-band feature by the polarity. A four-level energy band model is proposed for the transition scheme, and the field dependence of FIR bands numerically calculated by a simplified DdWELL structure is in good agreement with that of the PR spectra. The wavelength shift by the field strength and the spectral change by the polarity are discussed on the basis of four-level transition.

  • PDF

THE KOMPSAT- I PAYLOADS OVERVIEW

  • Paik, Hong-Yul;Park, Gi-Hyuk;Youn, Hyeong-Sik;Lee, Seunghoon;Woo, Sun-Hee;Shim, Hyung-Sik;Oh, Kyoung-Hwan;Cho, Young-Min;Yong, Sang-Soon;Lee, Sang-Gyu;Heo, Haeng-Pal
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 1998년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.301-306
    • /
    • 1998
  • Korea Aerospace Research Institute (KARI) is developing a Korea Multi-Purpose Satellite I (KOMPSAT-I) which accommodates Electro-Optical Camera (EOC), Ocean Scanning Multi-spectral Imager (OSMI), and Space Physics Sensor (SPS). The satellite has the weight of about 500kg and will be operated on the 10:50 AM sun-synchronized orbit with the altitude of 685 km. The satellite will be launched in 1999 and its lifetime is expected to be over 3 years. The main mission of EOC is the cartography to provide the images from a remote earth view for the production of 1/25000-scale maps of KOREA. EOC collects 510 ~ 730 nm panchromatic imagery with the ground sample distance(GSD) of 6.6 m and the swath width of 17 km by push broom scanning. EOC also can scan $\pm$45 degree across the ground track using body pointing method. The primary mission of OSMI is worldwide ocean color monitoring for the study of biological oceanography. It will generate 6 band ocean color images with 800 km swath width and 1km GSD by whiskbroom scanning. OSMI is designed to provide on-orbit spectral band selectability in the spectral range from 400 nm to 900 nm through ground command. This flexibility in band selection can be used for various applications and will provide research opportunities to support the next generation sensor design. SPS consists of High Energy Particle Detector (HEPD) and ionosphere Measurement Sensor (IMS). HEPD has missions to characterize the low altitude high-energy Particle environment and to study the effects of radiation environment on microelectronics. IMS measures densities and temperature of electrons in the ionosphere and monitors the ionospheric irregularities at the KOMPSAT orbit.

  • PDF

The solar photospheric and chromospheric magnetic field as observed in the near-infrared

  • Collados, Manuel
    • 천문학회보
    • /
    • 제41권1호
    • /
    • pp.31.4-32
    • /
    • 2016
  • Observing the solar atmosphere with ground-based telescopes in the near-infrared has a number of advantages when compared to classical measurements in visible wavelengths. One of them comes from the magnetic sensitivity of spectral lines, which varies as ${\lambda}_g$, where g is the effective $Land{\acute{e}}$ factor of the transition. This wavelength dependence makes the near-infrared range adequate to study subtle spatial or temporal variations of the magnetic field. Spectral lines, such as the photospheric Fe I $1.5648{\mu}m$ spectral line, with a $Land{\acute{e}}$ factor g=3, have often been used in the past for this type of studies. To study the chromosphere, the Ca II IR triplet and the He I $1.0830{\mu}m$ triplet are the most often observed lines. The latter has the additional advantage that the photospheric Si I $1.0827{\mu}m$ is close enough so that photosphere and chromosphere can be simultaneously recorded with a single detector in a spectrograph. The instrument TIP (Tenerife Infrared Polarimeter) has been continuously operating since 1999 at the 70-cm German VTT of the Observatorio del Teide and has been recently moved to the 1.5-m German GREGOR. During all this time, results have been obtained concerning the nature of the weak photospheric magnetic field of the quiet sun, magneto-acoustic wave propagation, evolution with the cycle of sunspot magnetic fields, photospheric and chromospheric magnetic field in emerging regions, magnetic field in chromospheric structures such as filaments, prominences, flares, and spicules, etc. In this talk, I will review the main results obtained after all these observations and mention the main challenges for the future. With its novel polarization-free design and a complete suite of instruments aimed at simultaneous (imaging and spectroscopic) observations of the solar photosphere and chromosphere, the EST (European Solar Telescope) will represent a major world-wide infrastructure to understand the physical nature of all these phenomena.

  • PDF

Analysis of the MSC(Multi-Spectral Camera) Operational Parameters

  • Yong, Sang-Soon;Kong, Jong-Pil;Heo, Haeng-Pal;Kim, Young-Sun
    • 대한원격탐사학회지
    • /
    • 제18권1호
    • /
    • pp.53-59
    • /
    • 2002
  • The MSC is a payload on the KOMPSAT-2 satellite to perform the earth remote sensing. The instrument images the earth using a push-broom motion with a swath width of 15 km and a GSD(Ground Sample Distance) of 1 m over the entire FOV(Field Of View) at altitude 685 km. The instrument is designed to haute an on-orbit operation duty cycle of 20% over the mission lifetime of 3 years with the functions of programmable gain/offset and on-board image data compression/storage. The MSC instrument has one channel for panchromatic imaging and four channel for multi-spectral imaging covering the spectral range from 450nm to 900nm using TDI(Time Belayed Integration) CCD(Charge Coupled Device) FPA(Focal Plane Assembly). The MSC hardware consists of three subsystem, EOS(Electro Optic camera Subsystem), PMU(Payload Management Unit) and PDTS(Payload Data Transmission Subsystem) and each subsystems are currently under development and will be integrated and verified through functional and space environment tests. Final verified MSC will be delivered to spacecraft bus for AIT(Assembly, Integration and Test) and then COMSAT-2 satellite will be launched after verification process through IST(Integrated Satellite Test). In this paper, the introduction of MSC, the configuration of MSC electronics including electrical interlace and design of CEU(Camera Electronic Unit) in EOS are described. MSC Operation parameters induced from the operation concept are discussed and analyzed to find the influence of system for on-orbit operation in future.

The Ground Checkout Test of OSMI on KOMPSAT-1

  • Yong, Sang-Soon;Shim, Hyung-Sik;Heo, Haeng-Pal;Cho, Young-Min;Oh, Kyoung-Hwan;Woo, Sun-Hee;Paik, Hong-Yul
    • 대한원격탐사학회지
    • /
    • 제15권4호
    • /
    • pp.297-305
    • /
    • 1999
  • Ocean Scanning Multispectral Imager (OSMI) is a payload on the KOMPSAT satellite to perform global ocean color monitoring for the study of biological oceanography. The instrument images the ocean surface using a wisk-broom motion with a swath width of 800km and a ground sample distance (GSD) of < 1km over the entire field of view (FOV). The instrument is designed to have an on-orbit operation duty cycle of 20% over the mission lifetime of 3 years with the functions of programmable gain/offset and on-board image data compression/storage. The instrument also performs sun and dark calibration for on-board instrument calibration. The OSMI instrument is a multi-spectral imager covering the spectral range from 400nm to 900nm using CCD Focal Plane Array (FPA). The ocean colors are monitored using 6 spectral channels that can be selected via ground commands. KOMPSAT satellite with OSMI was integrated and the satellite level environment tests including instrument aliveness/functional test, such as launch environment, on-orbit environment (Thermal/Vacuum) and EMI/EMC test were performed at KARl. Test results met the requirements and the OSMI data were collected and analyzed during each test phase. The instrument is launched on the KOMPSAT satellite on December 21,1999 and is scheduled to start collecting ocean color data in the early 2000 upon completion of on-orbit instrument checkout.

프리엠퍼시스를 이용한 CPSP 기반의 도달시간차이 추정 성능 개선 (Performance Improvement of CPSP Based TDOA Estimation Using the Preemphasis)

  • 권홍석;배건성
    • 한국음향학회지
    • /
    • 제28권5호
    • /
    • pp.461-470
    • /
    • 2009
  • 본 연구에서는 CPSP (Cross Power Spectrum Phase) 함수를 이용한 프레임 기반의 TDOA (Time Difference of Arrival) 추정시 나타나는 문제점들을 분석하고 연구하였다. 구형 윈도우함수를 이용해서 음성신호의 프레임을 추출할 때 나타나는 스펙트럼 누설현상은 CPSP 스펙트럼의 추정을 부정확하게 한다. 또한 스펙트럼 누설을 줄이기 위하여 구형이 아닌 다른 윈도우함수를 사용하여 프레임을 추출하면 프레임의 끝부분에서 발생하는 윈도우함수 가중치의 불일치 때문에 신호를 왜곡시킨다. 이 문제점들은 CPSP 기반의 TDOA 추정성능을 감소시킨다. 본 논문에서는 음성신호의 프리엠퍼시스를 이용하여 이러한 문제점들을 완화시키는 방법을 제안한다. 프리엠퍼시스된 음성신호의 다이나믹 레인지를 줄여줌으로써 스펙트럼 누설을 감소 시킨다. 제안한 프리엠퍼시스 방법을 검증하기 위하여, 다양한 잡음 및 잔향환경에서 TDOA 추정실험을 수행하였다. 실험결과 프라엠퍼시스된 마이크 출력에 구형 윈도우함수를 적용시켜 CPSP를 구할 경우 프리엠퍼시스를 하지 않거나 다른 윈도우를 사용하는 경우에 비해 TDOA 추정성능이 향상됨을 확인하였다.