• Title/Summary/Keyword: Spectral range

Search Result 949, Processing Time 0.026 seconds

Coherent Structures of Turbulent Wake Past a Rotating Circular Cylinder with a Tripping Wire (Tripping wire가 부착된 회전원주에 의한 난류휴류의 응집구조)

  • 부정숙;이종춘
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.19 no.8
    • /
    • pp.1927-1939
    • /
    • 1995
  • An experimental investigation is conducted to find out the large scale coherent structures in the intermediate wake past a rotating cylinder with a single tripping wire attached. Relation between the vortex shedding frequency and the spin rate of rotating cylinder and the effects of the tripping wire on the flow characteristics were studied by using spectral analysis and conditional phase average technique, respectively. It is found that the vortex shedding frequency is bound to a certain range and varies regularly as spin rate increases. The coherent structures are compared with those of the plain rotating cylinder in the case of spin rate of 1.0. Distance between the upper and lower center of vortices increase and the vortex shedding time is delayed, the velocity fluctuation energy decreases near the center line of vortices and it spreads out to the outer region. The Reynolds shear stress increases highly in the upper region and the turbulent wake width expands with strong entrainment process.

Seismic Integrity Analysis of an Electric Distributing Board Using the Response Spectra Analysis Method (응답스펙트럼해석법을 이용한 배전반의 내진건전성 해석)

  • Choi, Young-Hyu;Kim, Soo-Tae;Seol, Sang-Seok;Moon, Sung-Choon
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.4
    • /
    • pp.45-51
    • /
    • 2020
  • In this study, a response spectrum analysis of an electric distributing board (EDB) was conducted to investigate seismic integrity in the design stage. For the seismic analysis, the required response spectra of a safe shutdown earthquake with 2% damping (RRS/SSE-2%) specified in GR-63-CORE Zone 4 was used as the ground spectral acceleration input. A finite element method modal analysis of the EDB was also performed to examine the occurrence of resonance within the frequency range of the earthquake response spectrum. Furthermore, static stress caused by deadweight was analyzed. The resultant total maximum stress of the EDB structure was calculated by adding the maximum stresses from both seismic and static loads using the square root of the sum of the squares (SRSS) method. Finally, the structural safety of the EDB was investigated by comparing the resultant total maximum stress with the allowable stress.

A Study on the Fast Search Algorithm for Vector Quantization (벡터 양자화를 위한 고속 탐색 알고리듬에 관한 연구)

  • 지상현;김용석;이남일;강상원
    • The Journal of the Acoustical Society of Korea
    • /
    • v.22 no.4
    • /
    • pp.293-298
    • /
    • 2003
  • In this paper. we propose a fast search algorithm for nearest neighbor vector quantization (NNVQ). The proposed algorithm rejects those codewords which can not be the nearest codeword and reduces the search range of codebook. Hence it reduces computational time and complexity in encoding process, while it provides the same SD performance as the conventional full search algorithm. We apply the proposed algorithm to the adaptive multi-rate (AMR) speech coder and a general vector quantizer designed by LBG. algorithm. Simulation results show effectiveness of the proposed algorithm.

Indirect Determination of Cetirizine Hydrochloride by ICP-AES

  • Wang, Li-Sheng;Wei, Xiao-Ling;Gong, Qi;Jiang, Zhi-Liang;Li, Dong-Mei;Liang, Qing
    • Bulletin of the Korean Chemical Society
    • /
    • v.32 no.2
    • /
    • pp.595-598
    • /
    • 2011
  • Cetirizine hydrochloride reacted with $BiI_4^-$ in an acidic aqueous solution to form precipitate. After centrifugation, the atomic emission intensity of $Bi^{3+}$ contained in the supernatant solution was measured at the characteristic wavelength of 206.170 nm. The difference between the spectral signal intensity of the blank solution and that of the supernatant, ${\Delta}I$, was linearly related to the concentration of cetirizine hydrochloride. As a result, a new inductively coupled plasmaatomic emission spectrometric (ICP-AES) method was developed for the analysis of cetirizine hydrochloride. The linear range was from 27.7 to 184.8 $mg{\cdot}L^{-1}$, with a correlation coefficient (r) of 0.9961 and a detection limit of 9.6 $mg{\cdot}L^{-1}$. This method is simple and accurate, Without using toxic organic solvents, and is feasible for the quality control of cetirizine hydrochloride tablets and capsules.

Spectral Analysis and Performance Evaluation of VCXO using the Jig System (지그시스템을 이용한 VCXO의 스펙트럼 분석 및 성능평가)

  • Yoon Dal-Hwan
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.43 no.4 s.310
    • /
    • pp.45-52
    • /
    • 2006
  • In his paper, we have developed the SMD(surface mounted device) type PECL(positive emitter-coupled logic) VCXO of the $5{\times}7mm$ size for gratifying the requested specifications and the multilayer ceramic SMD(surface mounted device) package technology. The VCXO wired with the PECL(positive emitter coupled logic) package take place a stray inductance and a parasitic capacitance by the length and the inner pattern of the VCXO and the amplitude attenuation and signal loss due to the reflection of power source and the noise component. We have developed the Zig system to analyze the precise spectrum and evaluate the performance. The basic operating voltage is the 3.3 V and have the frequency range of 120MHz-180MHz. The Q factor is over 5K and it has the low jitter characteristics of 3.5 ps and low phase noise.

Spectroscopic Study of the Planetary Nebula NGC 6210: Velocity Structure and Permitted Lines

  • Lee, Seong-Jae;Wi, Jin-Kyung;Hyung, Siek
    • Journal of the Korean earth science society
    • /
    • v.30 no.5
    • /
    • pp.611-621
    • /
    • 2009
  • Using the spectroscopic data secured with the Hamilton Echelle Spectrograph at Lick Observatory, we found the physical condition of the planetary Nebula NGC 6210. The spectral line profiles of the permitted and forbidden lines have been analyzed using IRAF and StarLink/Dipso. The hydrogen number densities ($N_H$) are 2,000-20,000 $cm^{-3}$, and the electron temperatures are 8,100-10,300 K based on the forbidden lines. The expansion velocities, derived from the Full Width at Half Maximum (FWHM) and the double peak of the line profiles, are in the range of 10 to $45\;kms^{-1}$. The expansion velocities imply a shell structure with an accelerated nebular gas. We also derived abundances from the permitted lines of CII, CIII, NII, NIII, OII, and OIII, which may have been formed through the fluorescence mechanism. NGC 6210 is likely to be evolved from a progenitor of more than $3M_{\bullet}$, which had been born near the Galactic plane.

Survey of Electro-Optical Infrared Sensor for UAV

  • Jang, Seung-Won;Kim, Joong-Wook
    • Current Industrial and Technological Trends in Aerospace
    • /
    • v.6 no.1
    • /
    • pp.124-134
    • /
    • 2008
  • The rising demand for the high efficiency and high covertness in UAV motivates the miniature design of the high performing mission sensors, or payloads. One of the promising payload sensors, EO/IR sensor has evolved satisfying its demands and became the main stand-alone mission sensor for 200kg-range UAV. One aspect in development of EO/IR sensor concerns lack of specification criterions to represent its performance. Even though the high demand and competition among each manufacturer caused EO/IR features subject to rapid change collateral to new technology, the datasheets maintained the conventional outdated formats which leave some of the major components in ambiguity. Making comparisons or predicting actual performance with such datasheets is hardly worthwhile; yet, they could be important reference guide for the potential customers what to expect for the upcoming EO/IR. According to UAS Roadmap 2007-2032 published by DoD, one of the main potential customers as well as a main investor of EO/IR technology, EO/IR is expected to play key roll in solving urgent problems, such as see and avoid system. This paper will examine the recent representative EO/IR specialized in UAS missions through datasheets to find out current trend and eventually extrapolate the possible future trend.

  • PDF

Structural analysis and photoluminescent study of thin film rhombohedral zinc orthosilicate doped with manganese

  • Yoon, Kyung-Ho;Kim, Joo-Han
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.08a
    • /
    • pp.114-114
    • /
    • 2010
  • In this study, structural properties and photoluminescent characteristics of thin film rhombohedral zinc orthosilicate doped with manganese ($Zn_2SiO_4:Mn$) were investigated. The $Zn_2SiO_4:Mn$ films showed a pronounced absorption edge in the near ultraviolet wavelength region and a high optical transparency in the visible spectral range. The maximum transmittance reached 0.922 at 597 nm, which was very close to the transmittance of the fused quartz substrate alone (0.935). The $Zn_2SiO_4:Mn$ films were composed of rhombohedral polycrystalline grains with random crystallographic orientation. The broad-band photoluminescence emission peaked at around 525 nm was observed from the $Zn_2SiO_4:Mn$ films, which was ascribed to the radiative relaxation from the $^4T_1$ lowest excitation state to $^6A_1$ ground state of 3d5 electrons in divalent manganese ion. The excitation band exhibited a peak maximum at 259 nm in the near ultraviolet region, which was considered to be associated with the charge transfer transition of divalent Mn ion in the $Zn_2SiO_4$ system.

  • PDF

Baseline Design and Performance Analysis of Laser Altimeter for Korean Lunar Orbiter

  • Lim, Hyung-Chul;Neumann, Gregory A.;Choi, Myeong-Hwan;Yu, Sung-Yeol;Bang, Seong-Cheol;Ka, Neung-Hyun;Park, Jong-Uk;Choi, Man-Soo;Park, Eunseo
    • Journal of Astronomy and Space Sciences
    • /
    • v.33 no.3
    • /
    • pp.211-219
    • /
    • 2016
  • Korea's lunar exploration project includes the launching of an orbiter, a lander (including a rover), and an experimental orbiter (referred to as a lunar pathfinder). Laser altimeters have played an important scientific role in lunar, planetary, and asteroid exploration missions since their first use in 1971 onboard the Apollo 15 mission to the Moon. In this study, a laser altimeter was proposed as a scientific instrument for the Korean lunar orbiter, which will be launched by 2020, to study the global topography of the surface of the Moon and its gravitational field and to support other payloads such as a terrain mapping camera or spectral imager. This study presents the baseline design and performance model for the proposed laser altimeter. Additionally, the study discusses the expected performance based on numerical simulation results. The simulation results indicate that the design of system parameters satisfies performance requirements with respect to detection probability and range error even under unfavorable conditions.

Design and Fabrication of Miniaturized Optical Chopper Operated by Electromagnetic Actuation

  • Kim, Ho Won;Min, Seong Ki;Choi, Young Chan;Kong, Seong Ho
    • Journal of Sensor Science and Technology
    • /
    • v.23 no.3
    • /
    • pp.165-169
    • /
    • 2014
  • An existing infrared (IR) analysis system is generally composed of infrared source, IR focusing lenses, IR detector, and optical chopper. An optical chopper is widely used in combination with lock-in amplifier to improve the signal-to-noise ratio by periodically interrupting incident light beam. During recent years, a few researches on miniaturized optical chopper have been reported to apply to micro-scaled optical systems. In this paper, a micro optical chopper operated by electromagnetic actuation is proposed and applied to a miniaturized micro-scaled optical system operating in IR spectral range. Additionally, the fabrication method of the proposed micro chopper is demonstrated. The proposed micro optical chopper is composed of the polydimethylsiloxane (PDMS) membrane, solenoid, and permanent magnet. The permanent magnet is bonded on the PDMS membrane using an ultraviolet-activated adhesive. The operation of the chopper is based on the attractive and repulsive forces between permanent magnet and solenoid induced by an electrical current flowing through the solenoid. The fabricated micro optical chopper could operate up to 200 Hz of frequency. The maximum operating distance of the chopper with 7mm diameter membrane was $750{\mu}m$ at 100 Hz of frequency.