• Title/Summary/Keyword: Spectacle lenses

Search Result 27, Processing Time 0.036 seconds

Analysis of Vertex Refractive Power Accuracy of Soft Contact Lens with Holder Type (홀더종류에 따른 소프트 콘택트렌즈의 정점굴절력 측정의 정확도 분석)

  • Lee, Min-Jae;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.2
    • /
    • pp.105-115
    • /
    • 2015
  • Purpose: The accuracy for measuring the refractive power of hydrogel contact lenses by spectacle lens holder and contact lens holder was evaluated. The accuracy for each sample was also analyzed with water content and diopter categories. Methods: The hydrogel contact lenses used for measurement were classified into three categories in water content (38%, 43%, 58%). Also, three diopter categories of refractive power were used such as -3.000 D, -7.000 D, -10.000 D. And also, the reliability of measurement results were evaluated by measuring refractive power with spectacle lens holder and contact lens holder using an Manual lensmeter. Results: In case of spectacle lens holder method, the average value of refractive power was -3.3273D for -3.0000 D, -7.1306 D for -7.0000 D and -10.2944 D for -10.0000 D, respectively. In case of contact lens holder method, the average value of refractive power was -3.1060 D for -3.0000 D, -7.0028 D for -7.0000 D and -10.2611 D for -10.0000 D, respectively. In measurement of all diopters, the accuracy of contact lens holder method was better than spectacle lens holder method. Conclusions: From these results, it is judged that the refractive power of soft contact lens by manual lensmeter with contact lens holder have a higher accuracy than spectacle lens holder.

Function of Medical device on spectacle frame (안경테의 의료용구적기능)

  • Kang, H.S.;Seo, Y.W.;Kang, I.S.
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.1 no.1
    • /
    • pp.41-51
    • /
    • 1996
  • According to Korean pharmaceutic law, spectacles is a kind of medical device or instrument that is composed of a front and two temples with a pair of lenses. If the spectacle is not worn, it is a kind of optical device, but if it were worn, it will makes a new optical system to correct ametropia. Therefore, spectacles must be carried on by dispensing opticians.

  • PDF

Optical Evaluation of MR8 Material spectacle Lens with a New Method for the Analysis of Blue Light (새로운 청광 분석법을 적용한 MR8 안경재료의 광학적 시험 평가)

  • Kim, Ha-Rim;Jeong, Ju-Hyun
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.413-420
    • /
    • 2018
  • Purpose : We present a novel method for the analysis of blue light applied by the analysis method of David L. with optical experiment and blue light by measuring the transmittance by dividing it by the refractive power in the spectacle lens made by MR8. Methods : The lenses of -8.00D, -7.00D, -6.00D, -5.00D, -4.00D, -3.00D, and 0.00D manufactured by MR8 being sold in the market, were selected. The transmittance was measured at the intervals of 5 nm from 200 to 1000 nm with UV-VIS Spectrophotometers (SolidSpec 3700), and they were in range of the blue light (380 to 500 nm) analyzed by a David L.'s analysis method. Results : All of the MR8 lenses selected for this study almost completely blocked at the UV range. A lens of -8.00D was measured as the lowest transmittance of 59.56% in the blue light area and low values were measured at the blue areas 1 and 2 according to the analysis of David L.In the infrared ray area, the transmittance of all lenses gradually decreased. The average value of the luminous transmittance was 23.67% ~ 26.33% and then gradually decreased from -4.00D. Conclusion : Applying the analysis of David L., a minimum of 41.28% and a maximum of 46.60% were measured at the blue light 1 area and a minimum of 87.30% and a maximum of 97.55% were measured at the blue light 2 area. A minimum of 86.83% and a maximum of 96.55% were measured at the blue light 3 area, and the average was 94%. The luminous transmittance of the -3.00D lens was 26.33%, which was the highest, and that -8.00D was 23.67%, which was the lowest.

Study on the Labeling Items and Reliability of Spectacle Lens (안경렌즈의 표시사항 및 신뢰성에 관한 연구)

  • Ye, Ki-Hun;Kim, Tae-Hun;Kwon, Young-Seok;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.11 no.4
    • /
    • pp.323-327
    • /
    • 2006
  • For this study we research investigated the current situation of packing on the labeling items of domestic spectacle lens and reliability of spectacle lens. We use sample which is three hundred and ninety six spectacle lenses of eight company total. Refractive index of each sample in experiment is 1.55~1.56, 1.60~1.61 and 1.67. The percentage of labeling of A company and B company indicated the percentage of labeling of 80%, but The percentage of labeling of two companies indicated only 52.1% and 56.9% seperately. The most companies indicated comparatively a low marking ratio about packing on the labeling items. The results of difference the value of power which is recorded with the value of power which is measurement showed only small value.

  • PDF

Automatic Defect Inspection with Adaptive Binarization and Bresenham's Algorithm for Spectacle Lens Products (적응적 이진화 기법과 Bresenham's algorithm을 이용한 안경 렌즈 제품의 자동 흠집 검출)

  • Kim, Kwang Baek;Song, Dong Heon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.7
    • /
    • pp.1429-1434
    • /
    • 2017
  • In automatic defect detection problem for spectacle lenses, it is important to extract lens area accurately. Many existing detection methods fail to do it due to insufficient minute noise removal. In this paper, we propose an automatic defect detection method using Bresenham algorithm and adaptive binarization strategy. After usual average binarization, we apply Bresenham algorithm that has the power in extracting ellipse shape from image. Then, adaptive binarization strategy is applied to the critical minute noise removal inside the lens area. After noise removal, We can also compute the influence factor of the defect based on the fuzzy logic with two membership functions such as the size of the defect and the distance of the defect from the center of the lens. In experiment, our method successfully extracts defects in 10 out of 12 example images that include CHEMI, MID, HL, HM type lenses.

A Comparative Study on the Local Transmittance Homogeneity of the Ocular Lens (안경 렌즈의 국소적 투과율 균일도 비교 연구)

  • Park, Sang-Kook;Ri, Hyeong-Cheol;Jang, Yun-Seog;Sung, Duk-Yong;Kang, Sung-Soo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.4
    • /
    • pp.471-476
    • /
    • 2015
  • Purpose: We have analyzed the transmittance distribution of various ocular lenses using local transmittance microscope to investigate the optical homogeneity of the lens. Methods: The local transmittance of the laser which is focused on the surface of the spectacle lens was measured by using the photo-detector, lock-in amplifier and motorized-stage. 25 multi-coated lenses with non-tinted of 5 groups and 45 multicoated lenses with tinted of 9 groups were analyzed as a sample respectively. Results: Average and deviation of local transmittance for nontinted lenses were measured almost uniformly with various refractive index and coating. However, deviation of transmittance of for tinted lenses was analyzed as about 3.7 times larger than that of non-tinted lenses. Inhomogeneity of local transmittance of for tinted lenses was also analyzed as about 3.1 times larger than that of non-tinted lenses. Conclusions: We could analyze that standard deviation of transmittance and inhomogeneity of local transmittance of for tinted lenses is larger than that of non-tinted lenses using the local transmittance microscope. These analysis using local transmittance microscope can be utilized as a way to evaluate lens performance and improve optical homogeneity.

Evaluation of Vision-Specific Quality of Life between Spectacles and Contact Lens Wearers (안경과 콘택트렌즈착용자의 삶의 질 평가)

  • Kang, Sue Ah;Kim, Jung Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.3
    • /
    • pp.111-115
    • /
    • 2007
  • Purpose: The aim of this study was to assess vision-related quality of life and modes of refractive error correction. We administered NEI-VFQ (National Eye Institute Visual Function Questionnaire) to 137 subjects in two modes of refractive error correction: spectacles and contact lens wearers. The NEL-VFQ was developed to assess vision-related quality of life with respect to 1) visual symptoms 2) social function as well as difficulty with tasks and symptoms 3) economic issues and health concerns 4) psychological well-being. The NEL-VFQ was translated from English into Korean. Methods: All data were analyzed using SAS 8.0. Student's T-test was conducted to determine significant differences in each of the subscale (${\alpha}=0.05$). Result: The Peripheral Vision subscale score ($mean{\pm}SD$) was $52.2{\pm}32.7$ for the spectacle wearers, $88.6{\pm}18.1$ for contact lens wearers; the spectacle wearers' Peripheral Vision score was significantly lower than contact lens wearers (p=0.0001). There were also significant differences between two groups detected in Color Vision (p=0.001), General Vision (p=0.01) and Health Perception (p=0.01). Conclusion: Contact lens wearers and spectacle wearers were mostly high vision-related quality of life except General Vision and Health Perception. Especially, contact lens wearers were higher vision-related quality of life than spectacle wearers. Further studies on developing of good quality of contact lens will be needed to improve quality of life in ametropia.

  • PDF

A study on Monovision of Fitting soft contact lenses for College students (대학생에게 유도된 소프트 콘택트렌즈 모노비전에 관한 연구)

  • Kim, Jai-Min
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.181-188
    • /
    • 2004
  • Monovision is defined as correcting one eye for distance vision and the other eye for near vision. Single-vision contact lenses are used for each eye. The patient selectively suppresses one eye while using the other eye. This study was performed to measure binocular function and patient satisfaction with monovision induced by adding +3.00D to spectacle prescription for distance vision in nonpresbyopic students. This study comprised 144 nonpresbyopic students with monovision induced by adding +3.00D to spectacle prescription. Monovision was induced by undercorrecting the nondominant eye by adding 3.00 diopters for near vision and correcting the dominant eye with emmetropia for distance vision. For research of the binocular function on Monovision. This study was tested the obstacle course, water pouring test, catching and throwing, bead classification including the stereopsis test. These tests were comparative to the normal binocular state. As a results, the stereopsis have a significant reductions in Monovision. There was no significantly difference between monovision group and control group in monovision exercise (obstacle course, water pouring test, catching and throwing, and bead sorting) at near and distance. This study indicates that monovision is an effective and reasonable therapeutic modality for correcting presbyopia. By the application of above methods, this study could be used the student for the practical practice and understand on the Monovison.

  • PDF

Change of Contrast Sensitivity Induced by Tinted Spectacle Lens (칼라필터 렌즈에 따른 대비감도의 변화)

  • Seo, Jae-Myoung
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.21 no.1
    • /
    • pp.47-51
    • /
    • 2016
  • Purpose: The purpose of this study was to investigate the change of contrast sensitivity by prescribing tinted lenses and to provide the clinical manual. Methods: Contrast sensitivity was measured for twenty adults with normal vision while they wore yellow, orange and green tinted lenses. To measure contrast sensitivity, the 5 spatial frequencies (2, 4, 6, 8 and 10 cpd) were used for 33 ms and 233 ms, respectively. Results: The contrast sensitivity was overall higher with 233 ms than 33 ms (p<0.05). The peaks of contrast sensitivity with 33 ms and 233 ms were 1.75 log unit with the yellow lens and 1. 85 log unit without the color respectively. However, there was no significance between the yellow and orange tinted lens (p>0.64) Conclusions: Yellowish tinted lens that reduces chromatic aberration and the scattering is prescribed for the various purposes to improve visual functions. Before prescribing tinted lens, identifying characteristic of user and tinted lens for cut off wavelengths is recommended.

Induced Prism by the Categories of Spectacle Frames (안경테 종류에 따른 유발프리즘)

  • Park, Woo-Jung;Kim, Soo Woon;Hwang, Hae-Young;Yu, Dong-Sik;Son, Jeong-Sik
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.3
    • /
    • pp.311-319
    • /
    • 2012
  • Purpose: One of the critical aspects on dispensing glasses is to match the center of pupils to the optical center of lenses as the mismatched glasses are able to induce uncomfortable effects called prism which has been known to induce phoria, a main cause for asthenopia in many cases. Therefore, we investigated the induced prism occurred by mismatching centers between the center of pupils and the optical center of lenses. Methods: In this study, total 103 subjects were examined whether the center of pupils and the optical center of lenses are matched in horizontal and vertical directions, and then, the data was categorized into 4 groups based on the structural components of glasses. Total amount of prism was compared to show the effect of the glasses frame on the prism induction, and the value of measured prism was compared with the German RAL-RG 915 regulations. Results: The results in respect to the horizontal component showed that the induced prism was not found in 10.7% of total subjects. 73.8% of total subjects were influenced by induced prism, the range of prism was in a tolerance level. However, the 15.5% of total subjects seemed to be influenced by prism which is out of the criterion of tolerance. In case of vertical component, 23.3% of total subjects showed no effects of prism while early adopting glasses, 54.4% of total subjects showed a little prism effect within the criterion of tolerance, and 22.3% of total subjects showed the prism effect out of the tolerance range. This data indicates that group A and B that are less likely adjustable by fitting induce more prism than group C and D in horizontal and vertical components. Conclusions: In higher refractive error condition, it was found that aligning the optical center of lenses with the center of pupils by pre-fitting of glasses frame minimized prism induction in horizontal and vertical components, which ameliorates ocular fatigue. Therefore, appropriate optometric dispensing through fitting by opticians and precise design about monocular PD and monocular Oh are necessary to improve visual perception.