• Title/Summary/Keyword: Spectacle frame

Search Result 22, Processing Time 0.019 seconds

A Comparison Study on Consumer and Optometrist Perception Toward a Conversion into Medical Devices of Spectacle Frame (안경테의 의료기기 전환에 대한 소비자와 안경사의 인식 비교연구)

  • Han, Sun-Hee;Kim, Bong-Hwan;Kim, Hak-Jun;Kim, So-Yeoun;Lee, Hae-Ri;Kim, Dong-Ho;Jeon, Jun-Woo;Ha, Na-Ri
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.1
    • /
    • pp.15-23
    • /
    • 2015
  • Purpose: This study was investigated consumers' and optometrists' perception about spectacle frame in Busan and Ulsan to find on the right progress direction for conversion of spectacle frame into medical devices. Methods: 137 consumers surveyed in Busan and Ulsan and 100 optometrist surveyed in 'Busan continuing education of optometrist' filled in a questionnaire, then we compared and analyzed the results. Results: The 79% (108 people) of consumers and 94% (94 people) of optometrists agreed to conversion into medical devices of spectacle frame. The reason was shown that the consumer expected to improve the optometrist reliability and the optometrist expected to improve the optometrist professionalism. While, the 21% (29 people) consumer and 6% (6 people) optometrist opposed to conversion of spectacle frame into medical devices. The reason was revealed that the consumers were concerned about increase of medical insurance cost and the optometrists were concerned about that the spectacle frames can also be sold by medical device stores, not only by optical shops. Conclusions: The result of the survey was shown that the most of consumers and optometrists in Busan and Ulsan agreed on perception toward a conversion of spectacle frame into medical devices. But, we are considered that consumers' and optometrists' active attention and support are needed, with sequential implementation reflecting the concerns for this.

Study on Color and Oxidation Thickness for Titanium Spectacle Frames Colored by Anodization (양극산화방법으로 착색한 티타늄 안경테의 산화막 두께에 따른 색상 연구)

  • Hyun, Seung-Cheol;Jin, Moon-Seog;Kim, Yong-Geun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.4
    • /
    • pp.33-37
    • /
    • 2009
  • Purpose: To examine the coloring condition of titanium spectacle frames with various colors by using anodization method. Methods: We made an anodization coater. Platinum plate with $3{\times}3cm^2$ was used for a cathode and titanium spectacle frame specimens was mounted on an anode in an electrolyte. An electric source device were designed to supply steady state current. The color of the coated spectacle frame specimens were measured by a spectrophotometer equipped with an integrating sphere. We use CIE $L^*a^*b$ color system as chromaticity coordinates. Results: The thickness of $TiO_2$ of titanium spectacle frame specimens was varied as controlling current flow time for electrodes. The specimens with various kinds of color as a walnut, a yellow brown, a navy blue, a blue, a light blue, a mung bean, a yellowish green, a light purple, a purple, a flower pink, a bluish green, an emerald, and a green color etc. were obtained. The values of CIE $L^*a^*b^*$ for these specimens were measured and analyzed to be changed clockwise in chromaticity coordinates as the thickness of $TiO_2$ increases. Conclusions: We identified the coloring mechanism by anodization method in titanium spectacle frame specimens.

  • PDF

Model on the Elastic Behavior of Spectacle Frame (안경테 및 의료용구에 관한 연구 - 안경테의 탄성해석에 관한 모델 -)

  • Kim, DaeSoo
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.2
    • /
    • pp.127-138
    • /
    • 2000
  • Differential equations and their solutions were formulated to describe the deflection of both temples and front frames and the pressure exerted by them varying parameters such as elastic modulus, thickness, length, width and shape of crosssection. The effect of such parameters on the deflections of both temples and front frames was illustrated by plotting the solutions of the derived equations. Deflection of temples was found to be maximum where the cross section was diamond-shaped and to be minimum with the rectangular cross section while thickness and cross section area of temples remain constant. The effect of parameters consisting of front frame on the deflection of front frames are very similar to those on temples. The central deflection and pressure of front frame initiated by the temple decreases as the length of temple increases. Detailed analysis of stresses at various parts of the temple will help design custom made spectacle frame as well as most comfortable frames.

  • PDF

Effect of Tourmaline-added Eyeglass Frames on Normalization of Intraocular Pressure (토르말린이 첨가된 안경테가 안압 정상화에 미치는 영향)

  • Park, Sang-Chul;Jeong, Hye-Ri;Kwon, Jong-Moon;Lee, Gyu-Bin
    • The Korean Journal of Vision Science
    • /
    • v.20 no.4
    • /
    • pp.461-468
    • /
    • 2018
  • Purpose : Tourmaline, a natural ore material, was applied to the entire eyeglasses to observe changes in intraocular pressure (IOP), one of the factors related to human ocular metabolism. Methods : After making eyeglass frames by mixing TR-90, which is the main material of eyeglass frames and 7wt% of tourmaline, The changes of intraocular pressure before and after wearing of tourmaline spectacle frames were divided into low, middle and high groups according to the intraocular pressure in 90 normal subjects (46 men and 44 women) in their 20s. Results : Total intraocular pressure was a significantly decreased to -4.14% (p<0.000) in the right eye after wearing tourmaline frames, and significantly decreased to -6.39 % (p<0.000) and -4.64 % (p<0.017) in the High and Middle groups, respectively. Total intraocular pressure was a significantly decreased to -2.74 % (p<0.004) in the left eye, and -4.58 % (p<0.000) in the High group only showed statically significant value. Conclusion : In this study, the spectacle frame containing 7wt% tourmaline was used and it was confirmed that the intraocular pressure was significantly decreased after wearing the spectacle frame, and it became close to the average value of the normal intraocular pressure range. The results of this study showed that tourmaline, which has the effect of promoting the metabolism and blood circulation of the body, has an effect on the normalization of the intraocular pressure by attaching it to the spectacle frame.

Wholesale frames in the company distrubution channel analysis (도매안경테 회사의 유통경로 분석)

  • Jang, Woo-Yeong;Park, Jeong-Sik;Lee, Jeung-Young
    • Journal of the Korea society of information convergence
    • /
    • v.6 no.2
    • /
    • pp.89-96
    • /
    • 2013
  • In this study, focusing on workers wholesale optical frame, analyze the distribution of the optical frame, we studied the improvement of distribution. Has a work in the distribution industry and education in the various age groups, size of the company was small-scale. For the inventory management of the optical frame, systematic management is not performed, expectations for a better distribution system also was not large. In order to ensure better sales, wholesale optical frame company role intermediate of the spectacle manufacturers optical frame consumer deemed it is necessary to ensure the activation of internet sales and joint sale.

  • PDF

Various Factors giving Impacts On the Satisfaction level of spectacle Wearers (안경원 이용자의 만족에 영향을 미치는 요인)

  • Ju, Kyung-Bok
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.5 no.1
    • /
    • pp.181-186
    • /
    • 2000
  • This study has been implemented to identify the level of satisfaction of the Glass spectacle wearers on various services being given by optical shop workers and help them to provide services of higher quality to the spectacle wearers. The objectives of this study are the spectacle wearers who visited to the 5 Designated optical shops located in Seoul area. All the data has been collected for the 2 months period (Oct. 1 through Dec. 1. 1999.) By using structured, self-described research form. All the collected data were 250 copies in total but evaluated 222 copies only as we excluded 28 copies which has uncertain reply/contents. Major results are as follows: 1. The proportions of objectives by sex was male 54.1%, female 45.9% and by Academic career was University graduates 35.1%, High school graduates 32.4%. 2. The factors impects on the satisfaction level of spectacle wearers were the Employee's service and the status of frame. 3. the factors impacts on the intention for revisit the optical shops were facility status, the responsiveness on wearer s opinion and the employee s services. The factors impect the wearers to build up intention to recommend the visited optical Shops to the 3rd costomer were employee s services, the status of frames, the facility Status and the price level they paid. Considering the results of this study above mentioned, in order to raise up the satisfaction level of glass spectacle wearers, it s thought that the employee (optician) of optical shops have to well acquainted fluent knowledge on the glass spectacles and detailed to the spectacle wearers in a gentle manner and let them build up the reliabily.

  • PDF

Function of Medical device on spectacle frame (안경테의 의료용구적기능)

  • Kang, H.S.;Seo, Y.W.;Kang, I.S.
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.1 no.1
    • /
    • pp.41-51
    • /
    • 1996
  • According to Korean pharmaceutic law, spectacles is a kind of medical device or instrument that is composed of a front and two temples with a pair of lenses. If the spectacle is not worn, it is a kind of optical device, but if it were worn, it will makes a new optical system to correct ametropia. Therefore, spectacles must be carried on by dispensing opticians.

  • PDF

Clinical Evaluation on Variation of Face Form Angle of Eyewear (안경 안면각 변화에 대한 임상적 고찰)

  • Ko, Da-young;Kim, Ki-hong;Lee, Dong-Hee
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.20 no.4
    • /
    • pp.477-484
    • /
    • 2015
  • Purpose: This study was investigated to evaluate the effect of the variation of the face form angle(FFA) of spectacle frame on the visual acuity and the visual function. Methods: The visual acuity, the contrast sensitivity, the stereopsis, and the phoria were measured with the spectacle frame whose the FFA is at $5^{\circ}$ and $25^{\circ}$ and the surveys were conducted on subjective symptoms. Here, 30 adults (14 men and 16 women, average age:$25.46{\pm}3.9$), who did not have ocular diseases and were fully corrected in case of having had refractive error, were to act as experimental subjects for this measurement. Results: The visual acuity and the contrast sensitivity was decreased and the phoria was tended to increase to the esophoria direction at the FFA $25^{\circ}$ than at the FFA $5^{\circ}$. The stereopsis was significantly reduced at the FFA $25^{\circ}$ than at the FFA $5^{\circ}$. Also when the FFA was larger, the higher the degree of refractive error was, the more the increase of the subjective symptoms such as being blurred characters, being disturbed head, and having sore eyes was, which reveals a statistically significant correlation between them. Conclusions: If the FFA increases, the visual acuity, the contrast sensitivity and the stereopsis was found to decrease and the phoria to increase to the esophoria direction. Therefore it shows that the variation of the FFA of spectacle frame can influence the visual acuity and the visual function.

A Comparative Study on the Current Status of Spectacle Frames Standards (안경테 표준규격 실태에 관한 비교 연구)

  • Yu, Dong-Sik;Kim, In-Su;Son, Jeong-Sik;Sung, Duk-Yong
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.14 no.1
    • /
    • pp.9-15
    • /
    • 2009
  • Purpose: The aim of this study is to examine various national standards and to suggest problems and improvements on KS (Korean Industrial Standards) in spectacle frames. Methods: We surveyed the latest published KS, ISO (International Organization for Standardization), JIS (Japanese Industrial Standards), DIN (Deutsches Institut fur Normung) and ANSI (American National Standards Institute) standards with relating spectacle frames. The titles that were considered in comparative study were terms and vocabulary, measuring system and terminology, marking, requirements and test methods, formers, screw threads, and others. Results: There were 9 different languages such as English (USA and UK), French, Russian, Japanese, Chinese, German, Italian and Spanish for the lists of equivalent terms and vocabulary in all standards except KS and ANSI, but gave an explanation for terms and vocabulary in only KS. Complementary terms and definitions were not existed in annex of KS and ANSI for measuring system and terminology, but they were included in annex of standards of the others. KS and ANSI standard for requirements and test methods differed from the ISO revision. Except JIS and ANSI, standards of formers were almost identical. KS standard of screw threads were similar to JIS. Standards of welded joints and nickel release did not exist in KS. Conclusions: All standards except ANSI tend to follow ISO, especially DIN is almost entirely identical to ISO. But KS is behind the times because it has been amended lately or established in accordance with older editions of ISO. Therefore, in order to assist quality control and safety for spectacle frames, KS standards shall be superseded by the specifications which is identical to ISO within a reasonable time.

  • PDF

The Clinical Study on Spectacle Wearers of Highschool Students (고등학생 안경착용자의 착용상태에 관안 임상적 연구)

  • Kim, Sang-Kyun;Sung, A-Young
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.9 no.1
    • /
    • pp.19-27
    • /
    • 2004
  • The purpose of this study is to survey spectacle wearers's way of thinking through the questionaire and to investigate their wearing conditions through fitting conditions, the pantascopic angle, vertex distance, the coincidence of vertical and horizontal distance between optical center of the lens and pupillary distance of the eye in random selected 150 ametropic corrective wearers in the age of 17 to 19. The results are as follows : 1. The most popular causes of physical complaints in the ex-wearing spectacle are frame pressure(34.0%), slipping forward(30.0%) and most popular visual complaints are blur vision(30.0%) and asthenopia(20.0%). 2. The most common physical or visual complaints in the present wearing spectacle are slipping forward(30.0%), pressure (50.0%), color(10.0%). 3. Myopic glasses wearers accounted for 56.7% of the subjects, the others were compound myopic astigmatism. In 60% of the subjects' binocular diopter did not coincide. 4. In the pantascopic angle of the both eyes coincide in 66.7% of the subjects. The average of pantascopic angle is $10.07^{\circ}$. 5. In the vertex distance of the both eyes coincided in 65.3% of the subjects. the he average of vertex distance is 13.6 mm. 6. Among 150 eyes with monocular, the vertical distance between optical center of the lens and pupillary distance of the eye is within the RAL-RG 915 that is tolerance of ophthalmic dispensing in German Standards in 82 eyes (54.6%). 7. Among 150 eyes with monocular, the horizontal distance between optical center of the lens and pupillary distance of the eye is within the RAL-RG915 that is tolerance of ophthalmic dispensing in German Standards in 86 eyes(57.3 %).

  • PDF