• Title/Summary/Keyword: Speckle Noise Reduction

Search Result 41, Processing Time 0.028 seconds

Study on the Improvement of Lung CT Image Quality using 2D Deep Learning Network according to Various Noise Types (폐 CT 영상에서 다양한 노이즈 타입에 따른 딥러닝 네트워크를 이용한 영상의 질 향상에 관한 연구)

  • Min-Gwan Lee;Chanrok Park
    • Journal of the Korean Society of Radiology
    • /
    • v.18 no.2
    • /
    • pp.93-99
    • /
    • 2024
  • The digital medical imaging, especially, computed tomography (CT), should necessarily be considered in terms of noise distribution caused by converting to X-ray photon to digital imaging signal. Recently, the denoising technique based on deep learning architecture is increasingly used in the medical imaging field. Here, we evaluated noise reduction effect according to various noise types based on the U-net deep learning model in the lung CT images. The input data for deep learning was generated by applying Gaussian noise, Poisson noise, salt and pepper noise and speckle noise from the ground truth (GT) image. In particular, two types of Gaussian noise input data were applied with standard deviation values of 30 and 50. There are applied hyper-parameters, which were Adam as optimizer function, 100 as epochs, and 0.0001 as learning rate, respectively. To analyze the quantitative values, the mean square error (MSE), the peak signal to noise ratio (PSNR) and coefficient of variation (COV) were calculated. According to the results, it was confirmed that the U-net model was effective for noise reduction all of the set conditions in this study. Especially, it showed the best performance in Gaussian noise.

Wavelet Based Non-Local Means Filtering for Speckle Noise Reduction of SAR Images (SAR 영상에서 웨이블렛 기반 Non-Local Means 필터를 이용한 스펙클 잡음 제거)

  • Lee, Dea-Gun;Park, Min-Jea;Kim, Jeong-Uk;Kim, Do-Yun;Kim, Dong-Wook;Lim, Dong-Hoon
    • The Korean Journal of Applied Statistics
    • /
    • v.23 no.3
    • /
    • pp.595-607
    • /
    • 2010
  • This paper addresses the problem of reducing the speckle noise in SAR images by wavelet transformation, using a non-local means(NLM) filter originated for Gaussian noise removal. Log-transformed SAR image makes multiplicative speckle noise additive. Thus, non-local means filtering and wavelet thresholding are used to reduce the additive noise, followed by an exponential transformation. NLM filter is an image denoising method that replaces each pixel by a weighted average of all the similarly pixels in the image. But the NLM filter takes an acceptable amount of time to perform the process for all possible pairs of pixels. This paper, also proposes an alternative strategy that uses the t-test more efficiently to eliminate pixel pairs that are dissimilar. Extensive simulations showed that the proposed filter outperforms many existing filters terms of quantitative measures such as PSNR and DSSIM as well as qualitative judgments of image quality and the computational time required to restore images.

Speckle Noise Reduction and Image Quality Improvement in U-net-based Phase Holograms in BL-ASM (BL-ASM에서 U-net 기반 위상 홀로그램의 스펙클 노이즈 감소와 이미지 품질 향상)

  • Oh-Seung Nam;Ki-Chul Kwon;Jong-Rae Jeong;Kwon-Yeon Lee;Nam Kim
    • Korean Journal of Optics and Photonics
    • /
    • v.34 no.5
    • /
    • pp.192-201
    • /
    • 2023
  • The band-limited angular spectrum method (BL-ASM) causes aliasing errors due to spatial frequency control problems. In this paper, a sampling interval adjustment technique for phase holograms and a technique for reducing speckle noise and improving image quality using a deep-learningbased U-net model are proposed. With the proposed technique, speckle noise is reduced by first calculating the sampling factor and controlling the spatial frequency by adjusting the sampling interval so that aliasing errors can be removed in a wide range of propagation. The next step is to improve the quality of the reconstructed image by learning the phase hologram to which the deep learning model is applied. In the S/W simulation of various sample images, it was confirmed that the peak signal-to-noise ratio (PSNR) and structural similarity index measure (SSIM) were improved by 5% and 0.14% on average, compared with the existing BL-ASM.

Speckle Reduction based on Neuro-Fuzzy Technique (뉴로-퍼지를 이용한 스펙클 제거)

  • Kil, Se-Kee;Jeon, Yu-Yong;Oh, Hyung-Seok;Nishimura, Toshihiro;Kwon, Jang-Woo;Lee, Sang-Min
    • Journal of IKEEE
    • /
    • v.12 no.3
    • /
    • pp.158-166
    • /
    • 2008
  • Medical ultrasound has benefits in mobility and safety than any other medical techniques such as X-ray, CT and MRI but has speckle noise which decrease the ability of an observer to distinguish the fine details in diagnostic examination. But simple removing of speckle often causes losing boundary information. Then, in this paper, we presented a novel neuro-fuzzy method which could remove speckle efficiently without loss of boundary information. Proposed method consists of image clustering by fuzzy algorithm and image processingby neural networks which was learned by back propagation. From the experiments for simulation image and real ultrasound image, we could verify the proposed method.

  • PDF

Novel Laser Ultrasonic Receiver for Industrial NDE

  • Pouet, B.;Breugnot, S.;Clemenceau, P.
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.26 no.6
    • /
    • pp.380-389
    • /
    • 2006
  • A new laser-based ultrasonic receiver that is based on multi-channel interferometry is shown to be well suited for robust and sensitive detection of ultrasound in industrial environment. The proposed architecture combines random-quadrature detection with detector arrays and parallel multi-speckle processing. The high sensitivity is reached, thanks to the random phase distribution of laser speckle caused by surface roughness. High-density parallel signal processing is achieved by using a simple demodulation technique based on signal rectification. This simple detection scheme is also demonstrated for rejection of the laser intensity noise, making possible the use of lower cost laser without reduction in performances. Results demonstrating this new principle of operation and its performances are presented.

Noise Using Wavelet Pattern Change of Real-time Ultrasound Image (실시간 초음파 영상의 웨이블릿 패턴 변화를 이용한 노이즈 제거)

  • Cho, Young-bok;Woo, Sung-hee
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2018.05a
    • /
    • pp.510-512
    • /
    • 2018
  • The proposed method enhances the resolution of images by removing noise using wavelet transform to remove noise from images generated by ultrasound diagnosis. We propose an algorithm to reduce the speckle noise and enhance the edge of the ultrasound image. The proposed algorithm can enhance edges of various sizes by using wavelet transform which can use both frequency and spatial information. Experimental results show that the performance of the algorithm for noise reduction of ultrasound images is about 0.45ms for $520{\times}440$ images.

  • PDF

Reduction of Speckle Noise in Images Using Homomorphic Wavelet-Based MMSE Filter with Edge Detection (에지 영역을 고려한 호모모르픽 웨이브렛 기반 MMSE 필터를 이용한 영상 신호의 스펙클 잡음 제거)

  • 박원용;장익훈;김남철
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.28 no.11C
    • /
    • pp.1098-1110
    • /
    • 2003
  • In this paper, we propose a homomorphic wavelet-based MMSE filter with edge detection to restore images degraded by speckle noise. In the proposed method, a noisy image is first transformed into logarithmic domain. Each pixel in the transformed image is then classified into flat and edge regions by applying DIP operator to the image restored by homomorphic directional MMSE filter. Each pixel in flat region is restored by homomorphic wavelet-based MMSE filter. Each pixel in edge region is restored by the weighted sum of the output of homomorphic wavelet-based MMSE filtering and that of homomorphic directional MMSE filtering. The restored image in spatial domain is finally obtained by applying the exponential function to the restored image in logarithmic domain. Experimental results show that the restored images by the proposed method have ISNR improvement of 3.3-4.0 ㏈ and ${\beta}$, a measurement parameter on edge preservation, improvement of 0.0103-0.0126 and superior subjective image quality over those by conventional methods.

Usefulness of Median Modified Wiener Filter Algorithm for Noise Reduction in Liver Cirrhosis Ultrasound Image (간경변 초음파 영상에서의 노이즈 제거를 위한 Median Modified Wiener Filter 알고리즘의 유용성)

  • Seung-Yeon Kim;Soo-Min Kang;Youngjin Lee
    • Journal of the Korean Society of Radiology
    • /
    • v.17 no.6
    • /
    • pp.911-917
    • /
    • 2023
  • The method of observing nodular changes on the liver surface using clinical ultrasonography is useful for diagnosing cirrhosis. However, the speckle noise that inevitably occurs in ultrasound images makes it difficult to identify changes in the liver surface and echo patterns, which has a negative impact on the diagnosis of cirrhosis. The purpose of this study is to model the median modified Wiener filter (MMWF), which can efficiently reduce noise in cirrhotic ultrasound images, and confirm its applicability. Ultrasound images were acquired using an ACR phantom and an actual cirrhotic patient, and the proposed MMWF algorithm and conventional noise reduction algorithm were applied to each image. Coefficient of variation (COV) and edge rise distance (ERD) were used as quantitative image quality evaluation factors for the acquired ultrasound images. We confirmed that the MMWF algorithm improved both COV and ERD values compared to the conventional noise reduction algorithm in both ACR phantom and real ultrasound images of cirrhotic patients. In conclusion, the proposed MMWF algorithm is expected to contribute to improving the diagnosis rate of cirrhosis patients by reducing the noise level and improving spatial resolution at the same time.

An Efficient CT Image Denoising using WT-GAN Model

  • Hae Chan Jeong;Dong Hoon Lim
    • Journal of the Korea Society of Computer and Information
    • /
    • v.29 no.5
    • /
    • pp.21-29
    • /
    • 2024
  • Reducing the radiation dose during CT scanning can lower the risk of radiation exposure, but not only does the image resolution significantly deteriorate, but the effectiveness of diagnosis is reduced due to the generation of noise. Therefore, noise removal from CT images is a very important and essential processing process in the image restoration. Until now, there are limitations in removing only the noise by separating the noise and the original signal in the image area. In this paper, we aim to effectively remove noise from CT images using the wavelet transform-based GAN model, that is, the WT-GAN model in the frequency domain. The GAN model used here generates images with noise removed through a U-Net structured generator and a PatchGAN structured discriminator. To evaluate the performance of the WT-GAN model proposed in this paper, experiments were conducted on CT images damaged by various noises, namely Gaussian noise, Poisson noise, and speckle noise. As a result of the performance experiment, the WT-GAN model is better than the traditional filter, that is, the BM3D filter, as well as the existing deep learning models, such as DnCNN, CDAE model, and U-Net GAN model, in qualitative and quantitative measures, that is, PSNR (Peak Signal-to-Noise Ratio) and SSIM (Structural Similarity Index Measure) showed excellent results.

Speckle Noise Reduction of Ultrasonic NDT Using Adaptive Filter in WT Domain (웨이브렛 변환 평면에서 적응 필터를 이용한 초음파 비파괴검사의 스펙클 잡음 감소)

  • Jon, C.W.;Jon, K.S.;Lee, Y.S.;Lee, J.;Kim, D.Y.;Kim, S.H.
    • The Journal of the Acoustical Society of Korea
    • /
    • v.15 no.5
    • /
    • pp.21-29
    • /
    • 1996
  • Industrial equipment, such as power plant, is required to operate reliably, continuously and economically under rather severe conditions of temperature, stress, and enbironment. To test structural integrity and fitness, ultrasonic nondestructive testing is used because of effectiveness and simplicity. In this paper, wavelet transform based least mean square(LMS) algorithm is applied to reduce the influence of the interference occurring between randomly positioned small scatters. The RUN test is performed to check the nonstationarity of the speckle noise signal. The performance of this new approach is compared with that of the time domain LMS algorithm by means of condition numbers, signal-to-noise ratio and 3-D image. As a result, the wavelet transform based LMS algorithm shows better performance than the time domain LMS algorithm in this experiment.

  • PDF