• 제목/요약/키워드: Specimen stability

검색결과 302건 처리시간 0.03초

노후아파트 현장에서의 콘크리트 압축강도 추정 (Concrete Compressive Strength Prediction from Deteriorating Apartment Site)

  • 이규동;임홍철;임병호
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2006년도 춘계학술논문 발표대회 제6권1호
    • /
    • pp.155-158
    • /
    • 2006
  • Deduction of compressive strength in concrete members is very important to decide stability of structures. In this study, we compare the compressive strength of concrete between nondestructive test done to the building which was to be demolished at residential reconstruction site and destructive test of core specimen from the site. The result is more reliable because ore can compare the measurement of nondestructive tell with the result from destructive test using drilled cores. Compressive strength of each material was calculated with the result of rebound number test. In addition, we performed ultrasonic test for another result of compressive strength. And we made a comparative study of compressive strength of concrete drawn from both nondestructive and destructive tests.

  • PDF

잔골재를 활용한 경량기포 콘크리트의 특성에 관한 연구 (A Study on the Properties of Light Weight Foamed Concrete Using Fine Aggregate)

  • 한민철;신재경;정광복;배장춘;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2006년도 추계 학술발표회 논문집
    • /
    • pp.781-784
    • /
    • 2006
  • This paper investigates the fundamental properties of light weight foamed concrete with the variances in unit weight of concrete and adding ratio of stability agent(SA). Test showed that concrete adding SA slightly decreased fluidity but secured stable flow appearances without segregation of concrete components. All specimens in a standard condition represented that a sinking depth was not observed, while, in the wet condition, a specimen adding SA decreased the sinking depth $2{\sim}4mm$ more than control concrete. Compressive strength values of control concrete showed $0.03{\sim}0.3MPa$ higher than the concrete adding SA. As for the tensile strength, the specimen adding SA also had lower value, while the ratios of comp. to tens. strength presented $0.43{\sim}0.62$, which is relatively higher than ordinary concrete.

  • PDF

Cr2O3 첨가에 따른 PSS-PZT 압전 세라믹스의 유전 및 압전 특성 (Dielectric and Piezoelectric Characteristics of PSS-PZT Piezoelectric Ceramics with CrS12TOS13t Addition)

  • 홍재일;이개명;윤석진;유주현;박창엽
    • 대한전기학회논문지
    • /
    • 제41권6호
    • /
    • pp.687-693
    • /
    • 1992
  • To improve dielectric, piezoelectric and temperature stability in 0.50Pb(SnS11/2TSbS11/2T)OS13T - 0.35PbTiOS13T - 0.60PbZrOS13T + 0.4[wt%]MnOS12T piezoelectric ceramics which is used for surface acoustic wave devices, CrS12TOS13T was added and the specimens were fabricated by Hot Press method, and their characteristics were measured with CrS12TOS13T addition. From the results, in the specimen added by 0.2[wt%]CrS12TOS13T, dielectric constant and mechanical quality factor were 380 and 2307, respectively, and it was suited for surface acoustic wave device and the temperature coefficient of the resonant frequency in the specimen added by 0.4[wt%]CrS12TOS13T was the least value of 74.96[ppm/$^{\circ}C$].

Strategies for Operation of Single and Multiple Shake Tables

  • Laplace Patrick N.;Thoen Bradford K.
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2006년도 학술발표회 논문집
    • /
    • pp.571-578
    • /
    • 2006
  • Research using multiple shake tables present new and unique challenges in controls. Typical single shake table tests with large specimens must cope with significant specimen force feedback that can increase tracking error due to specimen gain, damping, and non-linearity. Multiple shaking tables with distributed specimens can produce cross-coupling forces due to inertial and response effects and forces due to static differential displacements. Although many various control architectures exist, basic simplified techniques can yield excellent results without risk to control stability. Off-line simulation techniques can also prove invaluable for studying system response before the real system is operated.

  • PDF

하수오의 독성평가를 위한 성분분석 및 안정성 시험 (Analysis and Stability Test of the Water Extract and Powder from Polygoni Multiflori Radix for Toxicity Study)

  • 트란환뉴엔크한;한강현;김용범;우미희;김정아;민병선
    • 생약학회지
    • /
    • 제51권1호
    • /
    • pp.86-91
    • /
    • 2020
  • For toxicological evaluation, water extracts and powder from Polygoni Multiflori Radix were made and the component analysis was followed by the Korean Pharmacopoeia method. To verify the stability of the water extract and powder from Polygoni Multiflori Radix used for toxic testing, the stability test was examined after storage at room temperature and in the cold room for one year. Water extract and powder from Polygoni Multiflori Radix were found to be stable for one year. Therefore, the use of the specimen of Polygoni Multiflori Radix after preparation during the animal test turned out to be stable.

잇솔질과 열처리가 세로머의 색안정성에 미치는 영향 (COLOR STABILITY OF CEROMERS AFTER THERMOCYCLING AND BRUSHING)

  • 이양진;조리라
    • 대한치과보철학회지
    • /
    • 제39권1호
    • /
    • pp.37-48
    • /
    • 2001
  • Ceromers, new indirect resin system, are now being adopted for esthetic restorations. Despite of its translucency and good color matching, color stability after long-term use was unknown till now. This in vitro study was designed to evaluate color stability of some ceromers when subjected to brushing after thermocycling. Three types of ceromers: Scupture, Targis, Artglass and a direct resin system, Z100 were prepared to disks 12 mm in diameter, 2.5 mm in thickness. All specimens were polished, and Sculpture and Targis specimens were divided two groups, respectively. Then, half of them were glazed according to manufacturer's instructions. All specimen were brushed 20,000 times after 10,000 cycle thermocycling. Color was measured with spectrophotometer after 1,000, 3,000, 10,000 times thermocycling and 20,000 time brushing, respectively. Color difference (${\Delta}E$) was calculated according to CIE LAB system. During thermocycling, Sculpture & Targis system with polished surface showed greater color change than any other groups. After brushing, color difference was reduced significantly. Mean values of ${\Delta}E$ ranged 0.98 to 2.98. All Ceromers were considered clinically acceptable after thermocycling and brushing, and color change mechanism was affected by the brands and finishing methods. It might be concluded that color change of ceromer is due to surface alteration.

  • PDF

TiAl 합금의 CaO 도가니 유도용융 및 정밀주조 (CaO Crucible Induction Melting and Investment Casting of TiAl Alloys)

  • 김명균;성시영;김영직
    • 한국주조공학회지
    • /
    • 제22권2호
    • /
    • pp.75-81
    • /
    • 2002
  • The main objectives were to investigate the suitability of CaO crucible for melting TiAl alloys and to develop investment mold for investment casting of TiAl alloys. TiAl alloy specimen were prepared by plasma arc furnace under argon atmosphere. After melting of TiAl alloy using CaO crucible, the results showed that there is little contamination of oxygen in the TiAl bulk. Conventional vacuum induction furnaces can be readily adaptable to produce cast parts of TiAl without high skilled techniques. The determination of optical metallography and microhardness profiles in investment cast TiAl alloy rods has allowed the gradation of the relative thermal stability of the oxides examined. The molds used for the present study were $ZrO_2$, $Al_2O_3$, CaO stabilized $ZrO_2$ and $ZrSiO_4$. Even although high temperature of mold preheating, $Al_2O_3$ mold is a promising mold material for investment casting of TiAl alloys in terms of thermal stability, cost and handling strength. It is important to take thermal stability and preheating temperature of mold into consideration for investment casting of TiAl alloys.

저온 열처리로 제작된 1.5 mol% 이트리아 안정화 지르코니아 세라믹스의 상 안정성 및 소결물성 (Phase stability and Sintered Properties of 1.5mol% Yttria-stabilized Zirconia Ceramics Fabricated by Low Temperature Sintering)

  • 김경태;최한철;박정식;이종국
    • 열처리공학회지
    • /
    • 제37권1호
    • /
    • pp.1-8
    • /
    • 2024
  • Phase stability of tetragonal crystals in yttria-stabilized zirconia ceramics is dependent on the content of yttria and the heat-treatment condition, related with mechanical properties. In this study, we fabricated the 1.5 mol% yttria-stabilized zirconia (1.5Y-YSZ) ceramics by cold isostatic pressing (CIP) and post-sintering at temperature range of 1200 to 1350℃ for 2 hours and investigated the sintered properties and microstructural evolution. Sintered and microstructural parameters, i.e, apparent density, grain size and phase composition of 1.5Y-YSZ ceramics were mainly dependent on the sintering temperature. Maximum sintered density of 99.4 % and average grain size of 200-300 nm could be obtained from the heat-treatment condition above sintering temperature at 1300℃ for 2 hours, possessing the superior mechanical hardness with 1200 Hv. However, phase stability of tetragonal grains in 1.5 YSZ ceramics is very low, inducing the phase transformation to monoclinic crystals on specimen surface during cooling after heat-treatment.

담수 어류 총수은 분석용 생물 표준물질 균질성, 안정성 시험평가 (The Homogeneity and Short-term Stability Test of Bio-matrix Reference Material for Total Mercury Analysis of Freshwater Fish)

  • 이수용;이장호;정다위;심규영;이하은;박기완
    • 한국환경과학회지
    • /
    • 제28권11호
    • /
    • pp.1033-1040
    • /
    • 2019
  • The National Environmental Specimen Bank (NESB) has set up a plan to develop reference materials in the facility for assuring analytical quality and validating analytical methods for its monitoring samples. Some of the crucial characteristics that reference materials must consist of are homogeneity and stability of both intra and inter-bottles. In this study, we examined the homogeneity and stability of cryogenically-milled muscle samples, from Common Carp (Cyprinus carpio) for total mercury. Homogeneity was tested using ANOVA analysis and regression analysis was used to test short-term stability. The variations of total mercury concentration did not significantly differ between the intra and the inter-bottle (F=0.8, p=0.37). Additionally, relative standard deviation of the total mercury concentration showed low values (2.28%). For the short-term stability test, total mercury variations were not statistically significant as demonstrated by the result of the regression analysis (F ratio = 3.11, p = 0.18). This suggests that the cryogenic-milling process has statistically proven the degree of homogeneity and short-term stability for samples of carp muscles in the chemical analysis for total mercury.

TiN 및 WC코팅된 치과용 어버트먼트 나사의 안정성 (Stability of TiN and WC Coated Dental Abutment Screw)

  • 손미경;이충환;정재헌;정용훈;최한철
    • 한국표면공학회지
    • /
    • 제41권6호
    • /
    • pp.292-300
    • /
    • 2008
  • Dental implant system is composed of abutment, abutment screw and implant fixture connected with screw. The problems of loosening/tightening and stability of abutment screw depend on surface characteristics, like a surface roughness, coating materials and friction resistance and so on. For this reason, surface treatment of abutment screw has been remained research problem in prosthodontics. The purpose of this study was to investigate the stability of TiN and WC coated dental abutment screw, abutment screw was used, respectively, for experiment. For improving the surface characteristics, TiN and WC film coating was carried out on the abutment screw using EB-PVD and sputtering, respectively. In order to observe the coating surface of abutment screw, surfaces of specimens were characterized, using field emission scanning electron microscope(FE-SEM) and energy dispersive x-ray spectroscopy(EDS). The stability of TiN and WC coated abutment screw was evaluated by potentiodynamic, and cyclic potentiodynamic polarization method in 0.9% NaCl solution at $36.5{\pm}1^{\circ}C$. The corrosion potential of TiN coated specimen was higher than those of WC coated and non-coated abutment screw. Whereas, corrosion current density of TiN coated screws was lower than those of WC coated and non-coated abutment screw. The stability of screw decreased as following order; TiN coating, WC coating and non-coated screw. The pitting potentials of TiN and WC coated specimens were higher than that of non-coated abutment screw, but repassivation potential of WC coated specimen was lower than those of TiN coated and non-coated abutment screws due to breakdown of coated film. The degree of local ion dissolution on the surface increased in the order of TiN coated, non-coated and WC coated screws.