• Title/Summary/Keyword: Specimen Collection

Search Result 103, Processing Time 0.032 seconds

Unrecorded species of Korean protozoans discovered through the project of 'Discovery of Korean Indigenous Species' III

  • Kyu-Seok Chae;Kang-San Kim;Jongwoo Jung;Gi-Sik Min
    • Journal of Species Research
    • /
    • v.12 no.4
    • /
    • pp.355-361
    • /
    • 2023
  • In this paper, we present unrecorded protozoans of Korea that were discovered, through the 'Discovery of Korean Indigenous Species' project hosted by the 'National Institute of Biological Resources (NIBR)'. A taxonomic account is provided for each identified species, offering comprehensive information such as species name, Korean name, collection site, synonyms, specimen vouchers, diagnoses, and figures. This study introduces 13 previously unrecorded Korean protozoan species that are classified into three phyla: Amoebozoa, Cercozoa, and Ciliophora. Notably, the cercozoan family Chlamydophryidae was recorded in Korea for the first time, together with the discovery of three previously unreported genera: Diaphoropodon within Cercozoa, and Metauroleptus and Hemicycliostyla within Ciliophora.

Measurement of Urine Enzymes for the Early Diagnosis of Nephrosis in Ruminants 1. Optimal Conditions for Measurement of Enzyme Activities and Normal Ranges (반추동물 신증의 조기진단을 위한 뇨효소 측정법 1. 효소활성도 측정을 위한 적합한 조건과 정상범위에 관하여)

  • Lee Chang-Woo;Lee Kyoung-Kap
    • Journal of Veterinary Clinics
    • /
    • v.6 no.2
    • /
    • pp.291-305
    • /
    • 1989
  • Present experiment was performed to establish the optimal reaction conditions for measurement of urinary gamma-glutamyltranspeptidase(${\gamma}$-GTP), N-acetyl-${\beta}$-D-glucosaminidase (AGS) and alanine aminopeptidase(AAP) activities in bovine and to investigate in vitro stability of the enzymes, within-run imprecision of the methods, and normal ranges. 1. The optimal wavelength for measurement of ${\gamma}$-GTP activity was 545nm. 2. The optimal pH of Tris-HCI buffer containing glycylglycine for measurement of urinary ${\gamma}$-GTP activity was 7.6~7.8(37$^{\circ}C$). 3. Coefficient of variance for within-run imprecision of urinary ${\gamma}$-GTP activity ranged from 4.8 to 7.2% and there was no significant difference among replications, 4. The optimal wavelength for measurement of urinary AGS activity was 405nm. 5. The optimal pH of citrate buffer for measurement urinary of AGS activity was 4.0(37$^{\circ}C$). 6. Coefficient of variance for within-run imprecision of urinary AGS activity ranged from 3.9 to 6.1% and there was no significant difference among replications. 7. The optimal wavelength for measurement of urinary AAP activity was 400nm. 8. The optimal pH of phosphate buffer for measurement of urinary AAP was 7.8. 9. Coefficient of variance for within-run imprecision of urinary AAP activity ranged from 2.5 to 4.8% and there was no significant difference among replications. 10. ${\gamma}$-GTP and AGS activities were increased significantly by gel-filtration. 11. Turbidity interfered with measurement of urinary AAP activity in bovine unless the specimen was gel-filterated. 12. Preservation of the specimen at 5$^{\circ}C$ or -20$^{\circ}C$ did not affect the AGS activity at least for 7 days after collection. 13. Preservation of the specimen at 5$^{\circ}C$ or 20$^{\circ}C$ did not affect the ${\gamma}$-GTP and AAP activities statistically, but some individual specimens revealed fluctuation during preservation. 14. ${\gamma}$-GTP, AGS and AAP activities revealed fluctuation by the tine of the day when the specimen was collected. 15. The normal ranges of urinary ${\gamma}$ -GTP, AGS and AAP activities were 6.60${\pm}$3.26(2.36-14.50), 1.31 ${\pm}$ 0.81(0.33-3.78), and 1.73 ${\pm}$ 0.55(0.77-3.03)U/l. respectively.

  • PDF

A Study on the Job Activities of the Emergency Nurses (응급실 근무 간호사의 업무분석)

  • 김광주;이향련;김귀분
    • Journal of Korean Academy of Nursing
    • /
    • v.25 no.4
    • /
    • pp.709-728
    • /
    • 1995
  • The job related activities of sixty nine nurses, working in the emergency rooms of three university hospitals, were analyzed for six days according to preestablished checklist of nursing activities ; the frequency of these activities and the amount of time spent in each specific nursing activity. The established checklist was monitored every five minutes for the duration of the duty autu, thus producing 414 items of data. The data were not gathered on consecutive days but over the period of one month from May 6, 1994 to June 5, 1994. The following conclusions are derived from analysis of the data : 1. Twelve categories of nursing activities were obtained : The primary activity was communication related to the patient and all information pertaining to the patient. Other activities included maintaining the patient's record, observation and assessment of the patient, cooperation with other medical personnel, management of equipment and drugs, procedure and treatment, specimen collection, consultation and education for the patient, including drug management and personal hygiene and any other relevant education to the patient's condition. 2. The average frequency of categorized nursing activity can be classified as follows : communication related to patient was the highest at 17.6 times. The next was maintaining the patient's record at 17.3 times. The observation and assessment occurred 16.9 times. Consultation and education for patients and family, 8 times, medication, 5.7 times, and procedures and treatments, 6 times. 3. The average time required for each activity was as follows : 230.1 minutes (or maintaining the patient's record, 204.9 minutes for communication related to the patient, 199.2 minutes for observation and assessment, 71.2 minutes for medication, 66 minutes for consultation and education of the patient and family, and 51.8 minutes for procedures and treatment. 4. The most demanding nursing activity in the emergency room for the nurse was answering questions from the patient's family, maintaining communication between the medical staff, maintaining and reviewing the patient's charts, writing prescriptions and monitoring 1. V. infusion rates. 5. The most time consuming nursing activities for the emergency room nurse include maintaining and following the patient's charts, communication between the medical staff, answering questions from the patient's family, observation of the patient and relaying all of the appropriate patient information to the incoming nurses during a shift change. 6. The F-test was administered to measure the required time for the categorized nursing activities according to day, evening, and night-shift nurses. There were significant differences (p<.05) in specimen collection, observation and assessment, cooperation between medical staffs, personal hygiene, communication related to patient, education and re-search. Posterior multiple comparison test showed that specimen collection, cooperation between medical staffs and personal hygiene were mostly done by the evening-shift nurses. Also most observations and assessments were done by the night-shift nurses. Education and communication to patients were done by day-shift nurses. Thus there were significant difference between shifts for the main nursing activities. So there should considev a reallocation of the duty of nurses on each shift. 7. The F-test also indicated that there wes a similarity in time duration for procedures and treatments and for cooperation between medical staff and nurses in all three hospitals. However, the remaining categories of nursing activities also showed a significant difference between the three hospitals. This indicated that there were differences in each emergency room that influence time for each categorized nursing activities and this should be given more consideration. Recommendations : 1. A seasonal difference should be considered in the activities of nurses in the emergency room and a comparative analysis should be carried out to deter-mine seasonal differentiation. 2. A study on more objectively measurable nursing activities should be administered as well as one determining the subjective responds towards nursing activities in the emergency room.

  • PDF

A Study on Stability evaluation in the freezing/thawing process of urine specimen analytes (소변 검체 분석물질의 냉/해동 과정 안정성 평가 연구)

  • Kim, Min Kyung;Kim, Sung Wook;Hwang, You Seong;Oh, Eunha
    • Journal of the Korean Applied Science and Technology
    • /
    • v.39 no.1
    • /
    • pp.52-62
    • /
    • 2022
  • The purpose of this study was to find a way to improve the stability and quality of urinalysis by checking the changes in the measurement values of representative clinical chemistry test items according to the repeated freezing and thawing before the urine test and the thawing process. All subjects were 10 healthy males, and the freeze and thaw stability test was performed using their urine samples. In the case of micro-albumin and amylase, there was no statistical significance at 37℃ with time, but at 42℃ and 60℃, there was a statistically significant change in the results with time. There were statistically significant changes in BUN, creatinine, uric acid, and glucose. As a result of long-term stability, after 7 days, glucose mutation increased and amylase decreased at 60℃. In the case of glucose and amylase, there was a statistically significant change in the results over time. To obtain accurate test results, accurate standardization of urinalysis including appropriate collection, storage, and storage methods of urine samples is required and systematic study of conditions for securing stability for each biomaterial is required.

A study on the condition assessment of large diameter water valves using non-destructive technologies (비파괴 기술을 이용한 대구경 수도용 밸브의 상태평가에 관한 연구)

  • Ho-Min Lee;Hyun-yong Choi;Suwan Park;Tae-min Oh;Chae-Min Kim;Cheol-Ho Bae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.37 no.4
    • /
    • pp.215-229
    • /
    • 2023
  • In this study, non-destructive technologies that can be applied to evaluate the integrity of valve materials, safety against internal pressure caused by corrosion, and the blocking function of large-diameter water valves during operation without requiring specimen collection or manpower entering the inside of the valve were tested to assess the reliability of the technologies and their suitability for field application. The results showed that the condition of the graphite structure inside the valve body can be evaluated directly through the optical microscope in the field without specimen collection for large-diameter water butterfly valves, and the depth of corrosion inside the valve body can be determined by array ultrasound and the tensile strength can be measured by instrumented indentation test. The reliability of each of these non-destructive techniques is high, and they can be widely used to evaluate the condition of steel or cast iron pipes that are significantly smaller in thickness than valves. Evaluation of blocking function of the valves with mixed gas showed that it can be detected even when a very low flow rate of mixed gas passes through the disk along with the water flow. Finally, as a result of evaluating the field applicability of non-destructive technologies for three old butterfly valves installed in the US industrial water pipeline, it was found that it is possible to check the material and determine the suitability of large-diameter water valves without taking samples, and to determine the corrosion state and mechanical strength. In addition, it was possible to evaluate safety through the measurement results, and it is judged that the evaluation of the blocking function using mixed gas will help strengthen preventive response in the event of an accident.

Comparison of Efficacy in Abnormal Cervical Cell Detection between Liquid-based Cytology and Conventional Cytology

  • Tanabodee, Jitraporn;Thepsuwan, Kitisak;Karalak, Anant;Laoaree, Orawan;Krachang, Anong;Manmatt, Kittipong;Anontwatanawong, Nualpan
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.16
    • /
    • pp.7381-7384
    • /
    • 2015
  • This study was conducted to 1206 women who had cervical cancer screening at Chonburi Cancer Hospital. The spilt-sample study aimed to compare the efficacy of abnormal cervical cells detection between liquid-based cytology (LBC) and conventional cytology (CC). The collection of cervical cells was performed by broom and directly smeared on a glass slide for CC then the rest of specimen was prepared for LBC. All slides were evaluated and classified by The Bethesda System. The results of the two cytological tests were compared to the gold standard. The LBC smear significantly decreased inflammatory cell and thick smear on slides. These two techniques were not difference in detection rate of abnormal cytology and had high cytological diagnostic agreement of 95.7%. The histologic diagnosis of cervical tissue was used as the gold standard in 103 cases. Sensitivity, specificity, positive predictive value, negative predictive value, false positive, false negative and accuracy of LBC at ASC-US cut off were 81.4, 75.0, 70.0, 84.9, 25.0, 18.6 and 77.7%, respectively. CC had higher false positive and false negative than LBC. LBC had shown higher sensitivity, specificity, PPV, NPV and accuracy than CC but no statistical significance. In conclusion, LBC method can improve specimen quality, more sensitive, specific and accurate at ASC-US cut off and as effective as CC in detecting cervical epithelial cell abnormalities.

Development of Quantification Method and Stability of ${\Delta}^9$-Tetrahydrocannabinol and 11-Nor-9-carboxy-${\Delta}^9$-Tetrahydrocannabinol in Oral Fluid (타액 중 ${\Delta}^9$-Tetrahydrocannabinol 및 11-Nor-9-carboxy-${\Delta}^9$-Tetrahydrocannabinol의 분석법 확립 및 안정성 검토)

  • Choi, Hye-Young;Baeck, Seung-Kyung;Jang, Moon-Hee;Choi, Hwa-Kyung;Chung, Hee-Sun
    • YAKHAK HOEJI
    • /
    • v.54 no.4
    • /
    • pp.226-231
    • /
    • 2010
  • Oral fluid has become increasingly popular as an alternative specimen in the field of driving under the influence of drugs (DUID) and work place drug testing. In this study, an analytical method for the detection and quantification of ${\Delta}^9$-tetrahydrocannabinol (THC) and its metabolite, 11-nor-9-carboxy-${\Delta}^9$-tetrahydrocannabinol (THC-COOH) in oral fluid by SPE and GC-MS was established and fully validated. The stability of THC and THC-COOH in oral fluid during storage was also determined by examining the THC and THC-COOH concentration changes depending on time and container materials. Oral fluid samples were kept over 21 days at room temperature, $-4^{\circ}C$ and $-20^{\circ}C$ in two different specimen collection tubes; glass and polypropylene tubes. Three replicates for each condition with different temperature and types of a container were analyzed at five different time points over 21 days. When oral fluid samples were stored in glass tubes, the loss of both THC and THC-COOH was less than 10% at all room temperature, $-4^{\circ}C$ and $-20^{\circ}C$. However, in polypropylene tubes, the loss of both THC and THC-COOH increased significantly over the study period. In particular, the concentration of THC decreased more rapidly than that of THC-COOH at room temperature and the maximal percentage of THC lost was 90.3% after 21 days. The result indicates that it would be necessary to collect oral fluid samples in glass containers and cool the samples until analysis in order to prevent the degradation of analytes.

Development of Simultaneous Quantification Method of Phenylalkylamines in Oral Fluid (타액 중 페닐알킬아민유도체류의 일제분석법 확립)

  • Choi, Hye-Young;Baeck, Seung-Kyung;Jang, Moon-Hee;Choi, Hwa-Kyung;Chung, Hee-Sun
    • YAKHAK HOEJI
    • /
    • v.55 no.2
    • /
    • pp.145-153
    • /
    • 2011
  • A simultaneous detection and quantification method for determining the Phenylalkylamine derivatives, such as methamphetamine (MA), amphetamine (AM), 3,4-methylenedioxymethamphetamine (MDMA), 3,4-methylenedioxyamphetamine (MDA), ketamine (KT), norketamine (NKT), phentermine (PT), fenfluramine (FFA) and phenmetrazine (PM), in oral fluid was developed and validated according to international guidelines. The validated method was applied to actual oral fluid samples collected from drug abuse suspects. The recovery of phenylalkylamines from oral fluid collection devices was also assessed. Oral fluid specimens from 20 drug abuse suspects submitted by the police were collected using Salivette$^{TM}$, Quantisal$^{TM}$ or direct expectoration. The samples were screened using a biochip array analyzer. For confirmation, the samples were analyzed by GC-MS in selected-ion monitoring (SIM) mode after extraction using automated SPE with a mixed-mode cation exchange cartridge and derivatization with trifluoroacetic anhydride (TFAA). The results from the immunoassay were consistent with those from GC-MS. All the oral fluid samples gave positive results for MA, AM, PT and/or PM. The detection of phenylalkylamines in oral fluid can provide a better indication of recent use than urine or hair. Therefore, the oral fluid specimen was useful for demonstrating phenylalkylamines abuse in the driving under the influence of drug (DUID) as an alternative specimen for urine.

The Effect of the Storage Duration and Temperature of EDTA Specimen for CBC and WBC Differential Count in SE-9000 Automated Cell Counter (SE-9000 자동 혈구계산기에서 EDTA 검체의 보관기간 및 온도가 CBC 및 백혈구 감별계산에 미치는 영향)

  • Hong, Seung-Bok;Kim, Jong-Seok;Shin, Kyeong-Seob
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.38 no.3
    • /
    • pp.147-151
    • /
    • 2006
  • Although various automated CBC analyzers with different WBC analytical principles were consequently introduced to clinical laboratory, the specific information concerning the suitability or unsuitability of aging samples is scarce. For this reason, we studied the effect of storage duration and temperature on CBC parameter in SE-9000 (SYSMEX Medical Electronics Co., Ltd., Kobe, Japan), automated CBC analyzer. We tested 32 K3-EDTA specimens with SE-9000 during 72 hours. Specimens were kept at room temperature (RT) and refrigerated and were analyzed at 0 hr, 4 hr, 8 hr, 24 hr, 48 hr and 72 hr after the collection of the specimens. The percentage changes from initial value for each parameters were calculated. Among the CBC parameters, hemoglobin, red blood cell count, mean corpuscular hemoglobin and platelets were stable for the study period at both temperatures. The mean corpuscular volume (MCV), hematocrit (Hct) and red cell distribution (RDW) increased and the mean corpuscular hemoglobin concentration (MCHC) decreased over time at room temperature. These parameters were stable when refrigerated. The leukocyte count was stable during 72hr at RT and when refrigerated. At room temperature, the relative percentages of neutrophils tend to increase, whereas those of lymphocyte and monocytes tend to decrease after 48 hours. When refrigerated, those of neutrophils and monocytes tend to increase, whereas those of lymphocytes tend to decreased over time. CBC parameters of refrigerated specimen were reliable for 72 hr for the exception of differential count from 24 hr but many CBC parameters, such as MCV, Hct, MCHC, RDW and differential count of leukocyte of blood stored at room temperature for 24 hr were unreliable.

  • PDF

Reexamination on Foreign Collectors' Sites and Exploration Routes in Korea (III) - with respect to T. Uchiyama - (외국인의 한반도 식물 채집행적과 지명 재고(III): Tomijiro Uchiyama)

  • Kim, Hui;Choi, Byoung-Hee;Chang, Chin-Sung;Chang, Kae-Sun
    • Korean Journal of Plant Taxonomy
    • /
    • v.37 no.2
    • /
    • pp.203-215
    • /
    • 2007
  • Uchiyama, Tomijiro visited the Korean peninsula including Busan, Incheon, Nampo, Pyongyang, Seoul, Mt. Geumgang of Gangwon-do, and Jeju-do twice for his plant collections in 1900 and 1902, respectively. During his plant explorations, Uchiyama collected numerous specimens which were investigated and studied by T. Nakai (Flora Koreana I and II and other publications) and H. $L{\acute{e}}veill{\acute{e}}$ later. Unfortunately all collection sites were simply described by Nakai in Romanized characters, so that it is difficult to pinpoint those sites using the current or the old Korean map. From this study, many locality names were reviewed based on his own plant specimens at TI and literatures, and those were listed as the order of his collection dates. Based on specimens deposited at TI, only ca. 200 specimens were confirmed, although 1,674 specimens were listed by Nakai. Among his collections, 2/3 of his collections were conducted in 1902 and among them 41 specimens were cited as type collections by Nakai.