• Title/Summary/Keyword: Specific nitrification rate

Search Result 44, Processing Time 0.025 seconds

Improvement of Nitrification Efficiency by Activated Nitrifying Bacteria Injection at Low Temperature (활성화된 질산화균 주입에 의한 저온 질산화효율 향상)

  • Lim, Dongil;Kim, Younghee
    • Journal of the Korean Society of Urban Environment
    • /
    • v.18 no.4
    • /
    • pp.473-483
    • /
    • 2018
  • In this study, we have developed a lab scale bioreactor to identify the characteristics of nitrification reaction according to operation condition (temperature, inhibitor (as Cl), activated nitrifying bacteria (ANB). etc) to improve nitrification efficiency at low temperature. Recovery rate of nitrification took about 4 days to reach the normal level by injected ANB after inhibition shock of CI injection at $20^{\circ}C$, when measured the concentration of $NO_2{^-}-N+NO_3{^-}-N$ in the effluent. In the case of $10^{\circ}C$, recovery of nitrification rate took about 4 days to reach the level of half to the normal level and 7 days for complete recovery which took 3 days more than those at $20^{\circ}C$. At $10^{\circ}C$ considering the winter season, the specific nitrification rate(SNR) of the from 1 day to 6 days after injected ANB according to its operation condition increased from 0.029 to 0.767 mgN/gSS/hr. The simulated SNR for the 8th day after the injected ANB at $10^{\circ}C$ was 0.840, 3.625 mgN/gSS/hr, respectively as linear function and exponential function, expecting to exceed level of 2.592 mgN/gSS/hr at normal condition. It was confirmed that injection of ANB during low temperature operation has many effects for improving nitrification efficiency through this study. In future studies, if further studies are carried out the determination of ANB injection and the design of efficient ANB reactor considering the changes of operating characteristics by site, it will contribute to the improvement of nitrification efficiency in winter season.

Comparison of the Nitrification Efficiencies of Three Biofilter Media in a Freshwater System

  • Harwanto, Dicky;Oh, Sung-Yong;Jo, Jae-Yoon
    • Fisheries and Aquatic Sciences
    • /
    • v.14 no.4
    • /
    • pp.363-369
    • /
    • 2011
  • Total ammonia nitrogen (TAN) removal efficiencies of a sand filter (SF), polystyrene microbead filter (PF), and Kaldnes bead filter (KF) media were evaluated under ammonia loading rates of 5, 25, and 50 g $m^{-3}day^{-1}$. The volume of each filter media tested was 7 L, and the water flow rate for all filter media was 24 L/min. The specific surface areas of the SF, PF, and KF were 7,836, 3,287, and 500 $m^2/m^3$, respectively. Sand was fluidized and the other two media were trickle filtered. The volumetric TAN removal rate increased with increasing ammonia loading rate for all filter media. Mean volumetric TAN removal rates under the ammonia loading rates of 5, 25, and 50 g $m^{-3}day^{-1}$ in SF (39.3, 168.6, and 322.7 g $m^{-3}day^{-1}$, respectively) were higher than those in PF (35.0, 157.4, and 310.5 g $m^{-3}day^{-1}$, respectively) and KF (32.1, 142.5, and 288.1 g $m^{-3}day^{-1}$, respectively). These results were related to differences in the specific surface areas of the filter media. PF was the most economic media for efficiently removing TAN.

Effect of Coagulant addition on Nutrient Removal Efficiency in a Submerged Membrane Bioreactor (응집제의 첨가에 따른 Membrane bioreactor 의 고도처리 효율 연구)

  • Park, Jong-Bu
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.2
    • /
    • pp.235-241
    • /
    • 2011
  • This study was performed to investigate the characteristics of nutrient removal of municipal wastewater in the submerged membrane bioreactor by addition of alum directly into aerobic tank. Membrane bioreactor consists of three reactors such as two intermittent anaerobic tanks and the aerobic tank with hollow fiber membrane. The removal efficiencies of $COD_{cr}$, BOD, SS, TN and TP on the membrane bioreactor were 94.0%, 99.1%, 99.9%, 66.9%, and 58.9%, respectively. In addition, The removal efficiencies of $COD_{cr}$, BOD, SS, TN and TP on the membrane bioreactor with alum addition were 93.4%, 99.0%, 99.9%, 63.2%, and 96.8%, respectively. There was little difference between them on the nutrient removal efficiencies except phophorus removal. The estimated sludge production, specific denitrification rate, specific nitrification rate and phosphorus removal content on the membrane bioreactor were 1.76 kgTSS/d, $0.055mgNO_3-N/mgVSS{\cdot}d$, $0.031mgNH_4-N/mgVSS{\cdot}d$, and 0.095 kgP/d, respectively. And The estimated sludge production, specific denitrification rate, specific nitrification rate and phosphorus removal content on the membrane bioreactor with alum addition were 2.90 kgTSS/d, $0.049mgNO_3-N/mgVSS{\cdot}d$, $0.030mgNH_4-N/mgVSS{\cdot}d$, and 0.160 kgP/d, respectively. The alum content added was 1.7 molAl/molP on an average. The increasing ratio of tran-membrane pressure on the membrane bioreactor was $0.0056kgf/cm^2{\cdot}compared$ to $0.0033kgf/cm^2{\cdot}d$ on the membrane bioreactor with alum addition. There was a slightly reduction effect on membrane fouling by alum addition.

Nitrogen and Phosphorus Removal of Municipal Wastewater with Temperature in CNR Process (섬모상담체를 이용한 혐기, 무산소, 호기공정(CNR공법)의 온도변화에 따른 하수의 질소, 인의 제거특성)

  • 김영규;양익배;김인배;이영준
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.1
    • /
    • pp.112-118
    • /
    • 2001
  • The aim of this study was to evaluate on the removal effect of total nitrogen and phosphorus in municipal wastewater with temperature change from 1$0^{\circ}C$ to 24$^{\circ}C$ in CNR(Cilia Nutrient Removal) process. CNR process is the process combining $A^2$/O process with cilium media of H2L company. The removal efficiencies for T-N were found to be 57.9% at 1$0^{\circ}C$ below, 53.7% at 10-2$0^{\circ}C$, 52.2%at 20-24$^{\circ}C$ and 44.4% over 24$^{\circ}C$ respectively. The removal efficiencies for T-P were 53.3% at 1$0^{\circ}C$ below, 59.1% at 10-2$0^{\circ}C$, 72.4% at 20-24$^{\circ}C$ and 50.0% over 24$^{\circ}C$ respectively. The specific nitrification rate (kg NH$_3$-N/kg MLSS.d) of Oxic basin was 0.088 and 0.053 at 1$0^{\circ}C$ below, 0.077 at 10-2$0^{\circ}C$, 0.097 at 20-24$^{\circ}C$ and 0.088 over 24$^{\circ}C$ respectively. The specific denitrification rate (kg NH$_3$-N/kg MLSS.d) in anaerobic and anoxic was 0.013, 0.008 respectively.

  • PDF

The Study on denitrification of low organic loading sewage by pre-denitrification process (유기물부하가 낮은 하수의 전달탈질공법에 의한 탈질방안)

  • Lee, Cheol Seung;Seo, Jong Hwan;Kim, Jin U
    • Journal of Environmental Science International
    • /
    • v.13 no.9
    • /
    • pp.779-878
    • /
    • 2004
  • This study was conducted to analyze the operating conditions of predenitrification process to improve the treatment efficiency in low organic loading sewage plant in use today, and to investigate the treatment efficiency of pilot plant added night soil as well as the nitrogen removal characteristics of pilot plant added carbon sources. In the operation under the condition of $BOD_{5}$ sludge load 0.03-0.28kg $BOD_{5}$/kg VSS/d and oxic ammoniac nitrogen sludge load 0.02-0.24 $kgNH_{4}^{+}$-N/kg MLVSS/d, nitrification efficiency is higher than 95%. In order to achieve 70% nitrogen removal at the T-N sludge loading 0.06kg T-N/kg VSSㆍd and the SRT 6~11 days, optimum operating factors were revealed to $CODc_{r}$/T-N ratio 9, recycle ratio 2.6, and denitrification volume ratio 0.33. At this time, denitrification capacity was approximately 0.09 kg $NO_{3}^{-}$-N/kg $CODc_{r}$; specific nitrification rate was 3.4mg $NH_{4}^{+}$-N/g MLVSS/hr; and specific denitrification rate was 4.8mg $NO_{3}^{-}$-N/g MLVSS/hr.

Nitrite Accumulation Characteristics and Quantitative Analyses of Nitrifying and Denitrifying Bacteria in a Sequencing Batch Reactor (연속회분반응기의 아질산 축적 특성과 질산화 및 탈질 미생물의 정량적 분포 연구)

  • Kim, Dong-Jin;Kwon, Hyun-Jin;Yoon, Jung-Yee;Cha, Gi-Cheol
    • Journal of Korean Society on Water Environment
    • /
    • v.24 no.3
    • /
    • pp.383-390
    • /
    • 2008
  • Recently, the interests on economical nitrogen removal from wastewater are growing. As a method of the novel nitrogen removal technology, nitrogen removal via nitrite pathway by selective inhibition of free ammonia and free nitrous acid on nitrite oxidizing bacteria have been intensively studied. The inhibition effects of free ammonia and free nitrous acid are low when domestic wastewater is used, however, because of its relatively lower nitrogen concentration than the wastewater from industry and landfill, etc. In this study, a sequencing batch reactor (SBR) is proposed for nitrogen removal to investigate the effect of the low nitrogen concentration on nitrite accumulation. Nitrification efficiency reached almost 100% during the aerobic cycle and the maximum specific nitrification rate ($V_{max,nit}$) reached $17.8mg\;NH_4{^+}-N/g\;MLVSS{\bullet}h$. During the anoxic cycle, average denitrification efficiency reached 87% and the maximum specific denitrification rate ($V_{max,den}$) reached $9.8mg\;NO_3{^-}-N/g\;MLVSS{\bullet}h$. From the analysis the main reason of nitrite accumulation in the SBR was free nitrous acid rather than free ammonia. Nitrite accumulation increased with the decrease of organic content in the wastewater and the mechanism is not well understood yet. From the result of fluorescent in situ hybridization, the distribution of nitrite oxidizing bacteria was in equilibrium with ammonium oxidizing bacteria when nitrite accumulation did not occur.

Simultaneous nitrification and denitrification by using ejector type microbubble generator in a single reactor

  • Lim, Ji-Young;Kim, Hyun-Sik;Park, Soo-Young;Kim, Jin-Han
    • Environmental Engineering Research
    • /
    • v.25 no.2
    • /
    • pp.251-257
    • /
    • 2020
  • This study was performed to verify the possibility of nitrification and denitrification in a single reactor. In batch type experiment, optimal point of experimental conditions could be found by performing the experiments. When supply location of microbubbles was located at half of width of the aeration tank and operating pressure of 0.5 bar, it was possible for zones in the aeration tank to be separated into anoxic and aerobic by controlling air suction rate according to operating pressure of the generator. To be specific, the concentration of dissolved oxygen (DO) in zone 1 and 2 of the aeration tank could be maintained as less than 0.5 mg/L. Also, in the case of concentration of oxygen in zone 3 and 4, the concentration of DO was increased up to 1.7 mg/L due to effects of microbubbles. In continuous flow type experiment based on the results of batch type experiments, the removal efficiency of nitrogen based on T-N was observed as 39.83% at operating pressure of 0.5 bar and 46.51% at operating pressure of 1 bar so it was able to know that sufficient air suction rate should be required for nitrification. Also, denitrification process could be achieved in a single reactor by using ejector type microbubble generator and organic matter and suspended solid could be removed. Therefore, it was possible to verify that zones could be separated into anoxic and aerobic and nitrification and denitrification process could be performed in a single reactor.

The Role of Primary Clarifier in Biological Processes for Nutrient Removal (생물학적 질소·인제거 공정에서 일차 침전지의 영향)

  • Whang, Gye-Dae;Kim, Tae-Kyung
    • Journal of Korean Society on Water Environment
    • /
    • v.23 no.1
    • /
    • pp.19-26
    • /
    • 2007
  • The lab-scale BNR processes fed with Municipal Wastewater Before or After Primary Clarifier (MWBPC or MWAPC) were operated to observe the behavior of particle organic matter in terms of nitrification and denitrification efficiency. As a result of the fractionation of the COD from MWBPC or MWAPC using an aerobic respirometric serum bottle reactor, the total mass of biodegradable organic matter from MWBPC is about 52% greater than the mass from MWAPC. Batch reactors were operated to observe the effect of the Particulate Organic Matter (POM) on substrate utilization for denitrification. Although the consumption of POM for denitrification was observed, the increment of the Specific Denitrification Rate (SDNR) was not great. In terms of the effect of POM on nitrification at different HRTs, activate sludge reactors were operated to determine the optimal HRT when MWBPC and MWAPC were fed relatively. All reactors showed a great organic matter removal efficiency. Reactors fed with MWAPC had obtained the nitrification efficiency above 90% when the HRT of 4 hr, at least, was maintained, while reactors fed with MWBPC had same efficiency when the HRT longer than 5 hr was kept. Three parallel $A^2/O$ systems fed with MWBPC or MWAPC relatively were operated to investigate the effects of POM on BNR processes with varying the HRT of an anoxic reactor. For all systems, the efficiency of organic matter removal and denitrification, respectively, was great and about the same. In case of denitrification efficiency, system with MWAPC had 1.5% lower than system with MWBPC at the same HRT of anoxic reactor of 2 hr, and the increasing the HRT of the anoxic reactor by 1 hr in systems fed with MWBPC resulted in a 3.5% increment. The denitrification rate was similar while the consumption of organic matter in systems fed with MWBPC was higher than system fed with MWBPC. It suggests that POM in MWBPC was not be used significantly as a substrate for denitrification in system with the HRT of 3 hr of an anoxic reactor.

Analysis on effect of heavy metal and Retention time to nitrification using industrial wastewater (중금속과 체류시간이 산업단지하수 질산화에 미치는 영향)

  • Im, Jiyeol;Gil, Kyungik
    • Journal of Wetlands Research
    • /
    • v.20 no.4
    • /
    • pp.390-397
    • /
    • 2018
  • The Municipal Wastewater Treatment Plant(MWTP), located industrial estate, has a problem of decreasing nitrification efficiency. In this research, it was analyzed that effect of heavy metals and retention time to nitrification based on operational result of laboratory scale reactors. And suggest improving MWTP operation method for increasing nitrification efficiency based on findings. According to operational result, laboratory scale reactor shows over 60% nitrification efficiency over hydraulic retention time(HRT) 0.5 day. However, the nitrification efficiency of S MWTP(high heavy metal concentration) sample was lower than that of A MWTP(low heavy metal concentration) sample in same operational condition. The main reason was heavy metals in industrial wastewater. This heavy metals was acted as inhibitor to nitrifier in reactors. So, activity of nitrifier was analyzed based on specific nitrification rate(SNR). The SNR of S MWTP sample shows 0.13 ~ 0.21 mg NH4/gMLSS/hr and that of A MWTP sample shows 0.74 mg NH4/gMLSS/hr. As a result, the activity of nitrifier of S MWTP was lower than that of A MWPT. In other words, retrofit methods for improving nitrification efficiency in MWTPs located industrial estate were that to increase retention time in biological treatment process or to pretreat heavy metal before being injected biological treatment process.

Effects on Microbial Activity of Aerobic Granular Sludge (AGS) in High-Salinity Wastewater (고농도 염분함유 폐수가 호기성 그래뉼 슬러지의 미생물 활성도에 미치는 영향)

  • Kim, Hyun-Gu;Ahn, Dae-Hee
    • Journal of Environmental Science International
    • /
    • v.28 no.7
    • /
    • pp.629-637
    • /
    • 2019
  • The purpose of this study was to evaluate the effect of high-salinity wastewater on the microbial activity of Aerobic Granule Sludge (AGS). Laboratory-scale experiments were performed using a sequencing batch reactor, and the Chemical Oxygen Demand (COD), nitrogen removal efficiency, sludge precipitability, and microbial activity were evaluated under various salinity injection. The COD removal efficiency was found to decrease gradually to 3.0% salinity injection, and it tended to recover slightly from 4.0%. The specific nitrification rate was 0.043 - 0.139 mg $NH_4{^+}-N/mg$ $MLVSS{\cdot}day$. The specific denitrification rate was 0.069 - 0.108 mg $NO_3{^-}-N/mg$ $MLVSS{\cdot}day$. The sludge volume index ($SVI_{30}$) ultimately decreased to 46 mL/g. The specific oxygen uptake rate decreased from an initial value 120.3 to a final value 70.7 mg $O_2/g$ $MLVSS{\cdot}hr$. Therefore, salinity injection affects the activity of AGS, causing degradation of the COD and nitrogen removal efficiency. It can be used as an indicator to objectively determine the effect of salinity on microbial activity.