• Title/Summary/Keyword: Specific charge

Search Result 575, Processing Time 0.035 seconds

Parameter Analysis of Swedish Bench Blast Design using Robust Design Method (강건설계법을 이용한 스웨덴식 벤치발파의 설계 인자 분석)

  • Yang, Hyung-Sik
    • Explosives and Blasting
    • /
    • v.31 no.2
    • /
    • pp.1-5
    • /
    • 2013
  • Parameters of Swedish bench blast design was analyzed by robust design method. Orthogonal array which is adopted in this study was $L_9(3^4)$ and the parameters were hole diameter, explosive type, hole inclination and rock factor of 3 levels. Result of analysis showed that maximum and minimum burden are most affected by hole diameter, followed by explosive type, rock type and inclination of hole. Parameters affecting specific charge are in the order of rock type, explosive type and to specific drilling are hole diameter and explosive type. Cost analysis showed that robust design is capable of parameter optimization.

Performance improvement of SOC indicator for electric vehicle using hydrometer (온-라인 비중계를 이용한 전기자동차용 바테리 잔존용량계의 성능개선)

  • 박종건;임영철;박철수;류영재
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.423-426
    • /
    • 1996
  • The conditions to be satisfied with SOC(State-of-Charge) indicator installed on the electric vehicle were that it should be used under frequent loading conditions and that it should enable the monitor to adjust to the aging effect. But, the state-of-charge test requires a lengthy stabilization period after discharge cycles and the ampere-hour test requires the knowledge of the battery capacity in terms of amp-hours. However, a monitoring technique combining the state-of-charge test to enable the monitor to adjust to the aging effect with the ampere-hour test to use under frequent loading condition is studied and implemented on a microcontroller-based circuit in this paper. Specially, optical fiber is used to realize hydrometer which is immune to electromagnetic interference and toxic environment and makes it possible to be used in a wide temperature range.

  • PDF

An Empirical Study for the Running Rationalization of Korean Export Insurance (수출보험 운영합리화를 위한 실증연구)

  • Kim, Ji-Yong
    • International Commerce and Information Review
    • /
    • v.10 no.4
    • /
    • pp.513-532
    • /
    • 2008
  • The purpose of this study was to analyze which factors have had impacts on extension export insurance charge of Korean export insurance. In order to attainment of this study, an empirical study was proceeded. The export insurance charge was hired as the dependent variable and export insurance premium, insurance compensation charge, export insurance collection charge and export insurance fund were used as independent variables. Data was used for estimation are the annually data from 1969 to 2007. From results of this analysis, we find the hired variables have highly correlation among them and the most influential factor turns out to be export insurance fund. Main results of this study was as follows : i) The export insurance fund must be increased immediately. ii) It is necessary that Korea Export Insurance Corporation give their attention to the compensate amount of export insurance compensation on specific insurance item. iii) It is necessary that Korea Export Insurance Corporation extension the collection efforts of the export insurance. iv) A reasonable raising of export insurance premium need to be done.

  • PDF

Charge Transfer Mechanism of Electrically Bistable Switching Devices based on Polyimide

  • Lee, Gyeong-Jae;Im, Gyu-Uk;Kim, Dong-Min;Lee, Mun-Ho;Gang, Tae-Hui;Jeong, Seok-Min
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2010.02a
    • /
    • pp.374-374
    • /
    • 2010
  • Charge transfer mechanism of poly(4,4'-aminotriphenylene hexafluoroisopropylidenediphthalimide) (TP6F PI) which exhibits bistable ON and OFF switching has been studied using photoemission electron spectroscopy (PES) and near-edge x-ray absorption fine structure (NEXAFS). Here, we demonstrate novel set-up in which holes are injected by photoemission process instead of direct charge carrier injection via metal electrode. The accumulated charges on the PI surface in the OFF state abruptly flow across the PI film when the bias voltage of a back electrode reaches a specific value, indicating that the film is changed to the ON state. Core level and x-ray absorption spectra probed at charge injection region via photoemission process do not show any evidences implying structural modification of TP6F PI during the phase change. Whereas, in valence band spectra, the highest occupied molecular orbital (HOMO) is shifted toward Fermi level, responsible for improved hole-mobility of TP6F PI of ON state.

  • PDF

Studies on $\alpha$-Amylase of Bacillus circulans F-2 (Part I) Purification of $\alpha$-amylase (Bacillus circulans F-2가 생산하는 $\alpha$-Amylase에 관한 연구 (제 1보) $\alpha$-Amylase의 정제)

  • ;Hajime Taniguchi;Yoshiharu Maruyama
    • Microbiology and Biotechnology Letters
    • /
    • v.9 no.4
    • /
    • pp.185-190
    • /
    • 1981
  • 1. $\alpha$-amylase from B. circulans F-2 was purified with specific activity 55.0 u/mg. protein (about 23 times of the original specific activity) and the yield of 25.5%, by means of corn starch absorption, salting out with ammonium sulfate (80% saturation), gel filtration on Bio-Gel P-100 and DE-32 column chromatography. 2 The purified enzyme showed two closely migrated protin bands on polyacrylamide disc gel electrophoresis, both of which have amylase activity judging from the activity staining of the gel. On SDS-polyacrylamide disc gel electrophoresis, however, the purified enzyme showed a single band suggesting that those two bands are the charge isomers of an amlyase having the slightly different charge. 3. Plot of log mobility of two bands versus polyacrylamide gel concentration according to Hedrick and Smith gave the parallel lines indicating them to be charge isomers. 4. To confirm the action pattern of two enzyme protein bands, each band was separated and was eluted from the gel and eluates were incubated with soluble starch. Oligosaccharide pattern produced by each eluate was examined by paper chromatography. The eluates of two bands showed the same action pattern. 5. The maltohexaose was the only hydrolysis product of soluble starch in the early stage of hydrolysis.

  • PDF

A Study on the Standard Rock fracture Method Using the Finecker Plus (미진동파쇄기를 이용한 표준암반반쇄굴착공법에 관한 연구)

  • Kim Young-Geun;Kim Il-Jung;Ki Kyung-Chul
    • Explosives and Blasting
    • /
    • v.23 no.1
    • /
    • pp.19-30
    • /
    • 2005
  • In this study, the standard particle velocity equations and the equation for calculating specific charge weight with application of rock fracture method using the finecker plus are suggested and the existing equation of fragmentation was transformed into one applicable to finecker plus. Standard rock fracture pattern was designed. Square root scaled equation is $V=345.39(D/\sqrt{W})^{-1.4484$. computable equation to specific charge wei인t is $W_f=(2.3\~2.5)\;f_agdV$, charge weight per hole is 0.54kg, and proportion of diameter 30cm fragmentation is about $48.7\%$. This rock fracture method nay him out to be more excellent than the other methods.

Analysis of Medical Charge for Inpatients with Stroke in Tertiary Hospital (종합전문요양기관에 입원한 뇌졸중환자의 진료비 분석)

  • Kim, Key-Hoon;Park, Jae-Yong;Han, Chang-Hyun
    • Korea Journal of Hospital Management
    • /
    • v.14 no.4
    • /
    • pp.71-87
    • /
    • 2009
  • This study was conducted to present strategies for efficient use of older people's medical expense and efficient management of hospital beds 삭제by analyzing factors which influenced medical charge of inpatients with stroke and medical charge of each medical treatment. The subjects was 1,070 inpatients with stroke in Academic hospital. The result of this study can be summarized as follows. In the case of cerebral hemorrhage, the rate of female was higher than that of male. In the case of cerebral infarction, the rate of male was higher than that of female. With increase of age, patients with cerebral hemorrhage decreased and patients with cerebral infarction increased. Medical charge for cerebral hemorrhage was 12,600,000 won, while that for cerebral infarction was 572,000 won. The medical charge with surgery was four times of that with non-surgery. The total medical charge for inpatients with stroke was 6,860,000 won. The patient payed 2,240,000 won(32.6%) and National Health Insurance Corporation payed 4,620,000 won(67.3%). Among charges of specific medical treatments, operation and treatment charge was highest(27.7%) in the case of cerebral hemorrhage, while examination charge was highest(32.2%)in the case of cerebral infarction. This study will provide basic information for efficient use of Medical Charge for Inpatients with Stroke.

  • PDF

Concentration/Purification Technologies: Multi-Functionalities of Nanostructures in Biosensing Fields

  • Son, Sang Jun;Min, Junhong
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.02a
    • /
    • pp.87-87
    • /
    • 2013
  • Sample concentration and purification processes are essential in the bio-analytical and pharmaceutical fields because most bio samples or media are extremely sophisticated. To concentrate and purify specific substances, passive membrane type filters have been utilized, which is driven by size or charge differences between target and others. The traditional and representative method to identify nucleic acid sequences in the complex biosample is gel electrophoresis, which has been worked by size and net charge of molecules. The adsorption phenomena have been also utilized to concentrate and purify biomolecules. This adsorption of biomolecule can be controlled under specific salts and surfaces as well as surface area. To utilize the differences of physical properties of molecules or bio-targets such as virus, bacteria, and cells, the nanotechnologies can be introduced in target concentration, purification, and isolation processes. In here, I'd like to briefly survey typical examples of nanobiotechnologies which are introduced in sample treatment. Also I specifically demonstrate two different simple techniques to concentrate and detect bacteria from the samples using multifunctional silica nanotube (SNT).

  • PDF

Electrodeposited Nano-flakes of Manganese Oxide on Macroporous Ni Electrode Exhibiting High Pseudocapacitance

  • Gobal, F.;Jafarzadeh, S.
    • Journal of Electrochemical Science and Technology
    • /
    • v.3 no.4
    • /
    • pp.178-184
    • /
    • 2012
  • A porous nickel (P-Ni) substrate was prepared by selective leaching of zinc from pressed pellets containing powders of Ni & Zn in 4 M NaOH solution. Anodic deposition of manganese oxide onto the porous Ni substrate ($MnO_x$/P-Ni) formed nano-flakes of manganese oxide layers as revealed in SEM studies. Pseudocapacitance of this oxide electrode was evaluated by cyclic voltammetry (CV) and chronopotentiometry (CHP) in 2 M NaOH solution. The specific capacitance of the Mn oxide electrode was as high as 1515 F $g^{-1}$, which was ten times higher than Mn oxide deposited on a flat Ni-ribbon. 80% of capacity was retained after 200 charge/discharge cycles. The system showed no loss of activity in dry form over period of days. The impedance studies indicated highly conducting $MnO_x$/P-Ni substance and the obtained specific capacitance from impedance data showed good agreement with the charge/discharge measurements.

Three-Dimensional Finite Element Analysis for Compression Molding of Step-Type Random/Unidirectional Polymer Composite Laminates (단부형상을 갖는 무배향/일방향 복합적층판의 압축성형에 있어서 3차원 유한요소해석)

  • 송강석;채경철;김이곤
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 1999.11a
    • /
    • pp.101-106
    • /
    • 1999
  • Fiber reinforced plastic composites is widely used to make be lightening of aircraft and automotive owing to having high specific strength and specific modulus. And it is very important to know a charge shape in order to have good products in the compression molding. In particular, the product such as a bumper beam is composed of the random and unidirectional composite mats. Its deformation and charge shape are very different by stack type of random and unidirectional mats. In this paper, the characteristics of flow fronts such as a bulging phenomenon for step-type random/unidirectional composite mats and slip parameters are studied numerically. And the effects of viscosity ratio and stack type on the mold filling parameters are also discussed.

  • PDF