• Title/Summary/Keyword: Specific absorption rate

Search Result 239, Processing Time 0.028 seconds

Studies on the Residual Bending Strength of Burned Wood treated with Fire-retardant Chemicals (내화처리연소목(耐火處理燃燒木)의 잔류(殘留) 휨강도에 관(關)한 연구(硏究))

  • Lee, Phil-Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.12 no.2
    • /
    • pp.10-19
    • /
    • 1984
  • The $3{\times}3{\times}30$ ($cm^3$) sized lumbers of Populus alba-grandulosa L. were treated with four fire-retardant solutions of ammonium sulfate, monoammonium phosphate, diammonium phosphate and aluminium chloride for 1, 15, 30, and 60 minutes and 1, 3, and 7 days. Thereafter they were air-dried and burned at high temperature about $1,800^{\circ}C$ and for short time of five minutes. This study estimated the relationship between absorbed chemical amounts and rate of weight loss or residual bending strength of these burned lumbers. The results were as follows: 1) In absorption amount of fire-retardant chemicals, diammonium phosphate showed the largest, aluminium chloride the smallest, but monoammonium phosphate and ammonium sulfate showed similar level. 2) The absorption amount of chemicals was decreased with the increase of specific gravity in the same species except aluminium chloride. 3) The rate of weight loss was decreased as the absorption amount of chemicals increased, especially monoammonium phosphate was most effective. 4) The MOR value of the residual bending strength was increased as the absorption amount of chemicals increased and especially monoammonium phosphate showed the most efficient effect. 5) Aluminium chloride showed more striking increase of MOR value of residual bending strength with the increase of absorption amount than any other chemical, therefore its MOR value was similar to the maximum MOR value of the most effective monoammonium phosphate. 6) The correlation between weight loss and MOR value of the residual bending strength was negative and aluminium chloride showed the most striking negative relation, but the others showed similar trends. 7) The correlation between work to proportional limit and absorption amount of chemicals was positive and the degree of increase in work to proportional limit was most in aluminium chloride, and the next, in monoammonium phosphate and diammonium phosphate in turn. 8) The correlation between work to maximum load and absorption amount of chemicals showed positive and diammonium phosphate revealed the best result and aluminium chloride showed better results than other two chemicals.

  • PDF

Mass transfer characteristics of benzene in nonpolar solution (비극성용매 내의 벤젠 물질전달특성)

  • 최성우;김혜진;박문기
    • Journal of Environmental Science International
    • /
    • v.11 no.6
    • /
    • pp.605-610
    • /
    • 2002
  • The absorption of benzene in nonpolar solution was studied in a laboratory-scale of bubble column varying of gas flow rates and gas-to-liquid ratios. A bubble column had a 0.8∼l$\times$10$\^$-3/ m$^3$ total volume (height 1500 mm, diameter 50 mm). Solution analysis was performed by GC-FID and GC-MSD. The objectives of this research were to select the best absorption fluid and to evaluate the mass transfer characteristics under specific conditions of each absorption. The results of this research were follow as: First, the heat transfer fluid is more efficient than the other nonpolar solution in removing VOC. Second, The benzene removal efficiency improved according to an increasing rate of gas flow. Also, volumetric mass transfer rate of column can be enhanced by increasing gas flow rate. Finally, the relation of gas flow rates, liquid amount, and volumetric mass transfer coefficient was obtained as follows. K$\_$y/a: 0.5906(V$\_$g//L)$\^$0.7611/ The following correlation of mass transfer coefficient and efficiency was proposed. v= 0.06078 K$\_$y/a$\^$0.2444/.

FDTD를 이용한 인체두부 모델내의 SAR 분포 특성 해석

  • 김두현;홍동욱
    • Proceedings of the Korean Institute of Industrial Safety Conference
    • /
    • 2002.11a
    • /
    • pp.271-275
    • /
    • 2002
  • 전파기술의 진보에 따라 일상생활 주변에서 전자파가 인체에 미치는 영향과 안전노출 허용한계에 대한 관심이 커지고 있다. 비 흡수율( Specific Absorption Rate )은 일반적으로 전자파 흡수율로 정의되고 주로 100[KHz]에서 10[㎓] 사이의 주파수 대역에서 전자파가 생체조직에 미치는 영향을 평가할 때 쓰이는 기본한계가 된다.(중략)

  • PDF

Dosimetry for Resonance-Based Wireless Power Transfer Charging of Electric Vehicles

  • Park, Sang-Wook
    • Journal of electromagnetic engineering and science
    • /
    • v.15 no.3
    • /
    • pp.129-133
    • /
    • 2015
  • This paper presents the dosimetry of a resonance-based wireless power transfer (RBWPT) system for electric vehicles applications. The compact RBWPT system is designed to transfer power at 150-mm distance. The electric and magnetic fields generated by the RBWPT system and the specific absorption rate in the human body model, which stands around the system, are calculated. These analyses are conducted in two cases: the alignment and the misalignment between the transmitter and the receiver. The matching loops are adjusted to maximize the power transfer efficiency of the RBWPT system for the misalignment condition. When the two cases were compared for the best power transfer efficiency, the specific absorption rates (SAR) in the misalignment case were larger than those in the alignment case. The dosimetric results are discussed in relation to the international safety guidelines.

Automatic RF Input Power Level Control Methodology for SAR Measurement Validation

  • Kim, Ki-Hwea;Choi, Dong-Geun;Gimm, Yoon-Myoung
    • Journal of electromagnetic engineering and science
    • /
    • v.15 no.3
    • /
    • pp.181-184
    • /
    • 2015
  • Evaluation of radiating radiofrequency fields from hand-held and body-mounted wireless communication devices to human bodies are conducted by measuring the specific absorption rate (SAR). The uncertainty of system validation and probe calibration in SAR measurement depend on the variation of RF power used for the validation and calibration. RF input power for system validation or probe calibration is controlled manually during the test process of the existing systems in the laboratories. Consequently, a long time is required to reach the stable power needed for testing that will cause less uncertainty. The standard uncertainty due to this power drift is typically 2.89%, which can be obtained by applying IEC 62209 in a normal operating condition. The principle of the Automatic Input Power Level Control System (AIPLC), which controls the equipment by a program that maintains a stable input power level, is suggested in this paper. The power drift is reduced to less than ${\pm}1.16dB$ by AIPLC, which reduces the standard uncertainty of power drift to 0.67%.

Organic Solvent Absorption Characteristics of Split-type Microfiber Fabrics

  • Lee Kwang Ju;Kim Seong Hun;Oh Kyung Wha
    • Fibers and Polymers
    • /
    • v.5 no.4
    • /
    • pp.280-288
    • /
    • 2004
  • Split-type nylon/polyester microfiber and polyester microfiber fabrics possess drapeability, softness, bulkiness, and smoothness, so that they can be applied in various industrial fields. In particular, these fabrics are able to absorb various organic solvents, and can be used as clean room materials. To investigate the chemical affinity between solvents and the compositional materials of these fabrics, the contact angle of thermally pressed film fabrics was measured with different solvents. The thermally pressed nylon/polyester fabric films showed a chemical attraction to formamide. The sorption properties of the microfiber fabrics were investigated using a real time testing device, and these tests showed that the sorption behavior was more influenced by the structure of the fibrous assembly than by any chemical attraction. The effect of the fabric density, specific weight, and sample structure on the sorption capacity and rate was examined for various organic solvents. The sorption capacity was influenced by the density and the specific weight of the fibrous assembly, and knitted fabric showed a higher sorption capacity than woven fabric. However, the sorption rate was less affected in lower viscosity solvents. On applying Poiseuille's Law, the lower viscosity solvents showed higher initial sorption rates, and more easily penetrated into the fibrous assembly.

Evaluation of Clinical Usefulness of Radio-Frequency Power Limitation in Brain MRI of Patients with Deep Brain Stimulation (뇌심부자극술 시술환자의 뇌 자기공명영상에서 고주파 출력의 제한기준에 대한 임상적 유용성 평가)

  • Yeon, Kyoo-Jin;Chang, Young-Ae;Lee, Seung-Keun;Lee, Tae-Soo
    • Journal of Radiation Industry
    • /
    • v.11 no.3
    • /
    • pp.139-144
    • /
    • 2017
  • To evaluation of clinical usefulness for B1+RMS limits, we compared image quality of Routine, Specific absorption rate (SAR) and Root mean square (RMS) protocol. 5 volunteers underwent Magnetic Resonance Imaging (MRI) scan of the brain using three different protocols. We draw Region of interest ROI in cortex, white matter, gray matter, putamen and thalamus of axial plan. Signal to noise ratio (SNR) were evaluated in each area and Contrast to noise ration (CNR) were evaluated between white matter and gray matter. Qualitative evaluation was used to score each ROI. B1+RMS is confirmed its usefulness compared to conventional SAR standard on the aspect of improvement of image quality, reduction of scan time and easy adjusting parameter.

EMC Debugging Technique for Image Equipments (영상기기의 EMC Debugging 기술)

  • Song, Min-jong;Kim, Jin-Sa
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.35 no.2
    • /
    • pp.143-148
    • /
    • 2022
  • For the purpose of treating health checkups and recovery of patients in a super-aged society, hospitals use devices designed with a reduction circuit of electromagnetic waves associated with the specific absorption rate of electromagnetic waves absorbed by the human body. In this paper, we proposed a filter improvement design method capable of reducing electromagnetic waves. As a result of confirming the validity of the proposed technique through simulation and experimental results, the following result values were obtained. Applying the common-mode (CM) inductor 4 mH to a calibration circuit, noise decreased in a multiband spectrum. Using the differential mode(DM) inductor 40 µH element in the primary calibration circuit, the noise decreased by 15 dB or more in the 3 MHz band spectrum. Also, applying the Admittance Capacitance (Y-Cap) 10 nF element in the secondary calibration circuit resulted in the decrease by more than 30 dB in the band spectrum before 2 MHz. After using a common-mode inductor 4 mH element in the tertiary calibration circuit, it decreased by more than 15 dB in the band spectrum after 2 MHz.

An Experimental Study on the Properties of Strength for Lightweight Concrete of Coated Scoria Lightweight Aggregate (피복 화산암재를 이용한 경량콘크리트의 강도특성에 관한 실험적연구)

  • 이시우;서치호
    • Magazine of the Korea Concrete Institute
    • /
    • v.2 no.4
    • /
    • pp.61-68
    • /
    • 1990
  • This experimental study is aimed to investigate the coating method of scoria lightweight aggregate for reo duction of water absorption and the physical dynamic characteristics of coated-scoria jightweight aggregate con¬crete. The coating methods are as follows: I) Non-coating method. II) Coating method of only cement paste. rn) Coating mehtod of surface-coating agent after coating by cement paste. IV) Coating method of only surfaee-coating agent. V) Coating method of cement pasted after coating by surface-coating agent. The summerized conclusion are as fallows ; 1) Specific gravity and the rate of water absorption were lowest when aggregate was covered by only surface-coating agent, especially, rate of absorption was about 10% of non-coating aggregate. 2) Coated-aggregate were about 0.87~0.97t/m3 and lightweight concrete made of coated-aggre¬gates were 1.80~ 1.94 t/m3 in unit weight. 3) Compressive strength of the lightweight concrete made of cement pasted-coating aggregate was about 200~215kg/crrl. 4) The higher the rate of water absorption of coarse aggregate, the higher the rate of deterioration of compressive strength.

Primary Productivity and Matter Economy of a Maize Plant Population. III. Phosphorus Economy in Relation to Dry Matter Production (옥수수 개체군의 일차생산성과 물질경제. 3. 건물생산과 인경제)

  • Huque, M. Anwarul;Seung-Dal Song
    • Journal of Plant Biology
    • /
    • v.24 no.1
    • /
    • pp.1-12
    • /
    • 1981
  • Phosphorus dynamics in terms of specific absorption rate, inflow and outflow rates. turnover rate, demand and supply, and utility index of a high yield Zea mays L. cv. Bokgyo field were evaluated using an analysis of successive production structures. The analysis was adopted for measuring quantitative changes in the population by stratified clip technique on every two weeks during the growing season. The seasonal trends of specific absorption rate (2. 4 mg P/g/day in maximum) and specific absorption efficiency (0. 03) closely correlated with that of relative growth rate of the population. The overall inflow and outflow of phosphorus was 3.41 g P/$m^2$/yr showing the maximum inflow of 2.99 g P/$m^2$/month in July. While the maximum phosphorus standing crop was 1.4 g P/$m^2$ showing the maximum turnover rate of 178% in late June. The accumulation of phosphorus along plant height declined monotonically in stems and roots but increased in foliage after heading. The proportions of the total annual demand of phosphorus were 24.4% for leaves, 22.5% for stems, 49.6% for fruits and 3.5% for roots. These demands were met with internal (18.2 %) and external (81.8 %) supplies. The seasonal highest phosphorus utility index was 1,091 in early June, while the average value was 655.

  • PDF