• Title/Summary/Keyword: Specific absorption rate

Search Result 242, Processing Time 0.027 seconds

Design and Implementation of WWAN Antenna with Metal Structure for Increasing Frequency Bandwidth and Gain (안테나 대역폭과 이득 향상을 위한 금속 구조체가 적용된 WWAN 안테나의 설계 및 구현)

  • Lee, Keon-Myung;Cho, Il-Hoon;Cho, Young-Hee;Lee, In-Young;Kim, Young-Sik
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.21 no.9
    • /
    • pp.940-946
    • /
    • 2010
  • In this paper, we proposed the internal antenna on PCB(Planar Circuit Board) for achieving WWAN(Wireless Wide Area Network) operation in the laptop computer. The proposed antenna has a metal structure instead of printed pattern on PCB to improve the antenna characteristics for GSM850/900 bands. Compared to PCB embedded antenna without metal structure, the proposed antenna occupies similar area of $74{\times}11{\times}0.5\;mm^3$ with before and the bandwidth of the proposed one for GSM850/900 bands is increased 13 MHz than before. Further we confirmed that the proposed antenna has higher radiation gain of -4.45~-2.29 dBi for GSM850/900 bands than PCB embedded antenna without metal structure.

Comparative Study on Microwave Probes for Plasma Density Measurement by FDTD Simulations

  • Kim, D.W.;You, S.J.;Na, B.K.;Kim, J.H.;Chang, H.Y.;Oh, W.Y.
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.218.1-218.1
    • /
    • 2014
  • In order to measure the absolute plasma density, various probes are proposed and investigated and microwave probes are widely used for its advantages (Insensitivity to thin non-conducting material deposited by processing plasmas, High reliability, Simple process for determination of plasma density, no complicate assumptions and so forth). There are representative microwave probes such as the cutoff probe, the hairpin probe, the impedance probe, the absorption probe and the plasma transmission probe. These probes utilize the microwave interactions with the plasma-sheath and inserted structure (probe), but frequency range used by each probe and specific mechanisms for determining the plasma density for each probe are different. In the recent studies, behaviors of each microwave probe with respect to the plasma parameters of the plasma density, the pressure (the collision frequency), and the sheath width is abundant and reasonably investigated, whereas relative diagnostic characteristics of the probes by a comparative study is insufficient in spite of importance for comprehensive applications of the probes. However, experimental comparative study suffers from spatially different plasma characteristics in the same discharge chamber, a low-reproducibility of ignited plasma for an uncertainty in external discharge parameters (the power, the pressure, the flow rate and so forth), impossibility of independently control of the density, the pressure, and the sheath width as well as expensive and complicate experimental setup. In this paper, various microwave probes are simulated by finite-different time-domain simulation and the error between the input plasma density in FDTD simulations and the measured that by the unique microwave spectrums of each probe is obtained under possible conditions of plasma density, pressure, and sheath width for general low-temperature plasmas. This result shows that the each probe has an optimum applicable plasma condition and reliability of plasma density measurement using the microwave probes can be improved by the complementary use of each probe.

  • PDF

Prediction of the Exposure to 1763MHz Radiofrequency Radiation Based on Gene Expression Patterns

  • Lee, Min-Su;Huang, Tai-Qin;Seo, Jeong-Sun;Park, Woong-Yang
    • Genomics & Informatics
    • /
    • v.5 no.3
    • /
    • pp.102-106
    • /
    • 2007
  • Radiofrequency (RF) radiation at the frequency of mobile phones has been not reported to induce cellular responses in in vitro and in vivo models. We exposed HEI-OC1, conditionally-immortalized mouse auditory cells, to RF radiation to characterize cellular responses to 1763 MHz RF radiation. While we could not detect any differences upon RF exposure, whole-genome expression profiling might provide the most sensitive method to find the molecular responses to RF radiation. HEI-OC1 cells were exposed to 1763 MHz RF radiation at an average specific absorption rate (SAR) of 20 W/kg for 24 hr and harvested after 5 hr of recovery (R5), alongside sham-exposed samples (S5). From the whole-genome profiles of mouse neurons, we selected 9 differentially-expressed genes between the S5 and R5 groups using information gain-based recursive feature elimination procedure. Based on support vector machine (SVM), we designed a prediction model using the 9 genes to discriminate the two groups. Our prediction model could predict the target class without any error. From these results, we developed a prediction model using biomarkers to determine the RF radiation exposure in mouse auditory cells with perfect accuracy, which may need validation in in vivo RF-exposure models.

Physicochemical Characteristics and Pharmacokintics of Ibuprofen Lysine Salts (흰쥐에서 이부프로펜 리신염의 물리화학적 특성 및 약물동태에 관한 평가)

  • Shin, Dae-Hwan;Kim, Tai-Sung;Park, Seong-Hyeok;Kim, Si-Hyun;Jo, Han-Jun;Han, Kun;Chung, Youn-Bok
    • YAKHAK HOEJI
    • /
    • v.55 no.3
    • /
    • pp.260-266
    • /
    • 2011
  • Two types of water soluble lysine salts of ibuprofen were prepared and evaluated. Physicochemical properties for ibuprofen-l-lysinate (IBL-l), ibuprofen-dl-lysinate (IBL-dl) and ibuprofen (IB) were studied on melting point, specific ratation, UV spectra and $^1H$-NMR spectra. There were not differences between IBL-dl and IBL-l in UV spectra and $^1H$-NMR spectra. The pharmacokinetic parameters of IB were compared to those of its lysine salts (IBL-l and IBL-dl) after i.v. or oral administration at the dose of 50 mg/kg (calculated as IB). Total body clearance ($CL_t$) and area under the plasma concentration-time curve (AUC) were not different between IB group and IBL groups after i.v. administration. On the other hand, IBL-l and IBL-dl produced peak plasma concentrations ($C_{max}$) significantly ealier and higher than IB. Time to reach peak concentration ($T_{max}$) after IBL administration was lower than that after IB administration. There was no difference in AUC across all different groups (IB, IBL-l and IBL-dl) after oral administration. However, absorption rate constant ($k_a$) of IBL-l and IBL-dl were significantly increased than that of IB. These results indicated that the administration of IBL-l and IBL-dl may be advantageous if rapid and reliable onset of pain relief is required.

Temperature-Range-Dependent Optimization of Noninvasive MR Thermometry Methods (온도범위에 따른 비침습적 자기공명 온도측정방법의 최적화)

  • Kim, Jong-Min;Kumar, Suchit;Jo, Young-Seung;Park, Joshua Haekyun;Kim, Jeong-Hee;Lee, Chulhyun;Oh, Chang-Hyun
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.6
    • /
    • pp.241-250
    • /
    • 2015
  • Noninvasive temperature monitoring is feasible with Magnetic Resonance Imaging (MRI) based on temperature sensitive MR parameters such as $T_1$ and $T_2$ relaxation times, Proton Resonance Frequency shift (PRFs), diffusion, exchange process, magnetization transfer contrast, chemical exchange saturation transfer, etc. While the temperature monitoring is very useful to guide the thermal treatment such as RF hyperthermia or thermal ablation, the optimization of the MR thermometry method is essential because the range of temperature measurement depends on the choice of the measurement methods. Useful temperature range depends on the purpose of treatment methods, for example, $42^{\circ}C$ to $45^{\circ}C$ for RF hyperthermia and over $50^{\circ}C$ for thermal ablation. In this paper, MR thermometry methods using $T_1$ and $T_2$ relaxation times and PRFs-based MR thermometry are tried on a 3.0 T MRI system and their results are reported and compared. In addition, the scanning protocol and temperature calculation algorithms from $T_1$ and $T_2$ relaxation times and PRFs are optimized for the different temperature ranges for the purpose of RF hyperthermia and/or thermal ablation.

Design of UWB MIMO Antenna for On-Body Application (인체 부착형 UWB MIMO 안테나 설계)

  • Joo, Eunman;Kwon, Kyeol;Jeon, Jaesung;Kim, Sunwoo;Choi, Jaehoon
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.25 no.2
    • /
    • pp.137-148
    • /
    • 2014
  • In this paper, design of a UWB MIMO antenna for an on-body application is proposed and antenna performance with body effect and the impact on the human body are investigated. The proposed MIMO antenna is composed of UWB antenna above ground plane and an additional plunger shaped isolator located between the two monopole antennas to enhance the isolation characteristic. The simulation and measurement are performed to analyze the effect of the human body on antenna performance when the human body is located in the near field of the antenna. According to the measurement results, the measured SAR values for antennas 1 and 2 are 0.132 W/kg and 0.08 W/kg, respectively when 0.5 mW input power is delivered. These values satisfy the FCC guideline which ragulates that the 1-g average SAR should be lower than 1.6 W/kg.

Analysis of Human Exposure for Wireless Devices Near War-Fighter (전투원 신체 주변 통신기기의 인체 노출량 분석)

  • Seo, Min-Gyeong;Choi, Jeung-Won;Ko, Jong Hwan;Lee, Hyunsung;Park, Juman;Pack, Jeong-Ki
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.24 no.1
    • /
    • pp.106-112
    • /
    • 2013
  • In this paper, human exposure of wireless devices was analyzed for various positions of the transmitter. The scenario for the position of the transmitting antenna was decided after discussion with ADD(Agency for Defense Development), and Korean male phantom model developed by ETRI were used to conduct simulations. The SAR values were analyzed by changing the position of the transmitter, and compared with Korean EMF regulations and ICNIRP guidelines. Additionally, human exposure was also investigated for two typical postures which can be posed by war-fighter.

A Study on the Properties of Traditional Korean Roof Tile by Using Nano Alumino Silicate (전통한식기와의 나노알루미노실리케이트 첨가에 따른 성능연구)

  • Kim, Soon-Ho
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.5
    • /
    • pp.425-432
    • /
    • 2020
  • The appearance of Korean traditional roof tiles is beautiful and excellent in water resistance, fire resistance and durability, but a high sintering temperature of 1,200℃ or higher is required. Therefore, due to the economical and heavy weight problem, the current trend is to use different roof finishing materials than Korean traditional roof tiles. By adding nanoaluminosilicate to clay and kaolin, which are the materials of the clay roof tiles, the sintering temperature is sintered at a low temperature of 1,000℃ or less, and the optimal mixing and material process is designed to satisfy the characteristics required as a Korean traditional roof tile. The results of this study again demonstrate the superiority of Korean traditional tiles with roof finishing materials using nanoaluminate. The properties of Korean traditional roof tiles that satisfy the criteria of KS F 3510 by applying fire resistance of natural minerals and nanoparticle technology to flexural strength of 2800N, Bulk specific gravity of 2.0g/㎤ and absorption rate of less than 10.0%, through which and researched materials development.

Effect of Ginseng on Calretinin Expression in Mouse Hippocampus Following Exposure to 835 MHz Radiofrequency

  • Aryal, Bijay;Maskey, Dhiraj;Kim, Myeung-Ju;Yang, Jae-Won;Kim, Hyung-Gun
    • Journal of Ginseng Research
    • /
    • v.35 no.2
    • /
    • pp.138-148
    • /
    • 2011
  • Exponential rise in the use of mobile communication devices has generated health concerns due to radiofrequency (RF) exposure due to its close proximity to the head. Calcium binding proteins like calretinin regulate the levels of calcium ($Ca^{2+}$) which plays an important role in biological systems. Ginseng is known for maintaining equilibrium in the human body and may play a beneficial radioprotectant role against electromagnetic field (EMF) exposure. In the present study, we evaluated the radioprotective effects of red ginseng (RG) extract in a mouse model. Calretinin (CR) expression was measured using a free-floating immunohistochemical method in the hippocampus of mice after 835 MHz EMF exposure for 5 h/d for 5 d at specific absorption rate=1.6 W/kg for the different experimental groups. The control animals were treated with NaCl while the experimental animals received 10 mg/kg ginseng, or 30 mg/kg; EMF exposed mice were also treated with NaCl, 10 mg/kg ginseng (E10), or 30 mg/kg (E30). Decreases in CR immunoreactivity (IR) along with loss of CA1 and CA3 interneurons and infragranular cells were observed in the ENaCl group while such losses were not observed in the E10 and E30 groups. CR IR significantly increased in the RG-treated group compared to control and EMF-exposed groups treated with NaCl. The study demonstrates that RG extract can serve as a radioprotective agent that maintains $Ca^{2+}$ homeostasis and prevents neuronal loss in the brain hippocampal region caused by RF exposure.

Prediction of Exposure to 1763MHz Radiofrequency Radiation Using Support Vector Machine Algorithm in Jurkat Cell Model System

  • Huang Tai-Qin;Lee Min-Su;Bae Young-Joo;Park Hyun-Seok;Park Woong-Yang;Seo Jeong-Sun
    • Genomics & Informatics
    • /
    • v.4 no.2
    • /
    • pp.71-76
    • /
    • 2006
  • We have investigated biological responses to radiofrequency (RF) radiation in in vitro and in vivo models. By measuring the levels of heat shock proteins as well as the activation of mitogen activated protein kinases (MAPKs), we could not detect any differences upon RF exposure. In this study, we used more sensitive method to find the molecular responses to RF radiation. Jurkat, human T-Iymphocyte cells were exposed to 1763 MHz RF radiation at an average specific absorption rate (SAR) of 10 W/kg for one hour and harvested immediately (R0) or after five hours (R5). From the profiles of 30,000 genes, we selected 68 differentially expressed genes among sham (S), R0 and R5 groups using a random-variance F-test. Especially 45 annotated genes were related to metabolism, apoptosis or transcription regulation. Based on support vector machine (SVM) algorithm, we designed prediction model using 68 genes to discriminate three groups. Our prediction model could predict the target class of 19 among 20 examples exactly (95% accuracy). From these data, we could select the 68 biomarkers to predict the RF radiation exposure with high accuracy, which might need to be validated in in vivo models.