• Title/Summary/Keyword: Specific Flow Rate

Search Result 548, Processing Time 0.036 seconds

A Study on Flow Coefficient and Flow Characteristics for Butterfly Valve by Numerical Analysis (수치해석에 의한 버터플라이 밸브의 유량계수 및 유동특성에 관한 연구)

  • Kwak, Kyung-Min;Cho, Ji-Sung;Kim, Jin-Dae;Lee, Jung-Hyung
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.11 no.4
    • /
    • pp.62-66
    • /
    • 2012
  • The objective of this study is to simulate flow coefficient and flow characteristics such as velocity and pressure distribution for butterfly valve. Butterfly valves used in this study are 65A, 80A and 100A, in size, and of which the opening angle is varied. The flow coefficient, Kv, increases as the disc opening and valve size are increase. When using flow coefficient meanwhile specific curve of flow rate is also determined. The flow velocity between disc and seat increase as the disc opening decrease. The re-circulating zone is also observed in downstream behind disc.

Influence of Bethanidine on the Renal Function of the Dog (개의 신장 기능에 미치는 Bethanidine의 영향)

  • 고석태
    • YAKHAK HOEJI
    • /
    • v.22 no.3
    • /
    • pp.138-147
    • /
    • 1978
  • Bethanidine, which is known as a sympathetic blocking agent, was injected into the vein of a dog in an attempt to investigate the influence on renal funciton. Bethanidine resulted in an increased urine flow and glomerular filtration rate, and it produced an increase of urinary sodium and potassium excretion and a decrease of reabsorption rate of sodium and potassium in renal tubules, whereas renal plasma flow showed no significant changes. After pretreatment of phentolamine, a specific alpha adrenergic blocking agent, bethanidine did not significantly increase glomerular filtration rate and diuresis, significantly increased urinary sodium and potassium excretion although the magnitudes were reduced when compared with that of bethanidine alone. In conclusion, bethanidine-induced diuresis appears to be the result of an inhibited tubuler reabsorpting of electrolytes within the kidney through its sympathetic blockade of renal nerves and of an increased glomerular filtration rate, which was caused by the constriction of vas efferense in the glomeruli.

  • PDF

A Study on the Pressure Control Process of Gas Regulators through Numerical Analysis (수치해석을 통한 가스 레귤레이터의 압력제어 프로세스 고찰)

  • Jung, Jun-Hwan;Nam, Chung-Woo;Kim, Min-Kyung
    • Journal of the Korean Institute of Gas
    • /
    • v.25 no.5
    • /
    • pp.37-51
    • /
    • 2021
  • The pressure drop phenomenon that occurs when the same flow rate is supplied to the gas regulator was analyzed. The regulator moves the position of the piston through the interaction of the force acting on the upper and lower parts of the piston and the spring tension to release the pressure of a specific range in a specific environment as constant pressure, thereby maintaining the pressure. The flow characteristics and pressure control process of the regulator were investigated through a numerical analysis technique as the volume of the fluid inside the regulator changed. As the gap between the piston and the piston seat decreased, the pressure drop increased and the flow velocity increased. It was verified through numerical analysis that the piston was positioned at 0.12mm under the same conditions as the pressure-flow test (inlet pressure 3MPa, outlet pressure 0.8MPa, flow rate 70kg/h).

Comparison of Seepage Quantity Calculated by Experiments and Finite Element Method (실험(實驗)과 FEM기법(技法)을 사용(使用)하여 구(求)한 침투유량(浸透流量)의 비교(比較))

  • Jin, Byung Ik;Kim, Jae Hong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.5 no.2
    • /
    • pp.83-90
    • /
    • 1985
  • The thesis is established on the basis of model tests on the central core dam. With variations in the upstream water level, the quantity of seepage in the downstream boundaries were obtained for each specific water level. Seepage alignment and equipotential lines to these occasions were also researched and measured. By making use of the resulting data from the experiment, the flow velocities and seepage quantity computed to the flow rate of each element of flownets by the Finite Element Method was compared with the values produced by experiments and approximate theoretical formula. Further to this, transitions of water level related thereto was also examined in the thesis. During the high water level, seepages shown by the experiment were larger than that of the F.E.M. Meanwhile, the in-between differences were found to be quite small during the low water level. In the flow rate of each element with which the flow-nets are constructed, flow velocities of the X and Z axis were faster on account of the variations in water level. Flow velocities of the Y axis were extremely small enough to be disregarded.

  • PDF

Several Problems in Reactor Coolant System Flow Rate Measurement

  • Ahn, Seung-Hoon;Auh, Geun-Sun;Suh, nam-Cuk;Park, Jun-Sang;Koo, Bon-Hyun
    • Nuclear Engineering and Technology
    • /
    • v.30 no.6
    • /
    • pp.592-608
    • /
    • 1998
  • Inspection of RCS flow measurements for the domestic pressurized water reactors has been performed by the Korea Institute of Nuclear Safety (KINS) as one of the authorized periodical inspection activities. The inspection results for the Westinghouse-type plants reveal that 1) the RCS flow instrumentation has been calibrated by using the initial design and commissioning test result, without reflecting the cycle specific reference flow measurements, 2) the loop-to-loop now variation in the actual flow measurement which has not been considered in the safety analysis affects the asymmetric How transient results, and 3) the measured RCS flows in Kori 3 and 4, Yonggwang 1 and 2 do not support the definition of the best estimate RCS flow, approaching the RCS flow limit. In this study, the revealed problems were discussed with review of the design and the RCS flow measurement uncertainty evaluation, and the technical approaches and recommendations for resolving these problems were proposed.

  • PDF

Characteristics of Sulfur Oxidation by a Newly Isolated Burkholderia spp.

  • JUNG JE, SUNG;JANG KI-HYO;SIHN EON-HWAN;PARK SEUNG-KOOK;PARK CHANG-HO
    • Journal of Microbiology and Biotechnology
    • /
    • v.15 no.4
    • /
    • pp.716-721
    • /
    • 2005
  • The role of an effective microbial species is critical to the successful application of biological processes to remove sulfur compounds. A bacterial strain was isolated from the soil of a malodorous site and identified as Burkholderia spp. This isolate was able to oxidize thiosulfate to sulfate, with simultaneous pH decrease and accumulation of elemental sulfur. The specific growth rate and the sulfate oxidation rate using the thiosulfate basal medium were $0.003 h^{-1}\;and\;3.7 h^{-1}$, respectively. The isolated strain was mixotrophic, and supplementation of $0.2\%$ (w/v) of yeast extract to the thiosulfate-basal medium increased the specific growth rate by 50-fold. However, the rate of sulfate oxidation was more than ten times higher without yeast extract. The isolate grew best at pH 7.0 and $30^{\circ}C$, and the sulfate oxidation rate was the highest at 0.12 M sodium thiosulfate. In an upflow biofilter, the isolated strain was able to degrade $H_2S\;with\;88\%$ efficiency at 8 ppm and 121/h of incoming gas concentration and flow rate, respectively. The cell density at the bottom of the column reached $3.2{\times}10^8$ CFU/(g bead) at a gas flow rate of 121/h.

Study on the Critical Nozzle Flow of Hydrogen Gas with Real Gas Effects (실제기체 효과를 고려한 수소기체의 임계노즐 유동에 관한 연구)

  • Kim, Jae-Hyung;Kim, Heuy-Dong
    • Proceedings of the KSME Conference
    • /
    • 2007.05b
    • /
    • pp.3003-3008
    • /
    • 2007
  • Critical nozzle has been frequently employed to measure the flow rate of various gases, but hydrogen gas, especially being at high-pressure condition, was not nearly dealt with the critical nozzle due to treatment danger. According to a few experimental data obtained recently, it was reported that the discharge coefficient of hydrogen gas through the critical nozzle exceeds unity in a specific range of Reynolds number. No detailed explanation on such an unreasonable value was made, but it was vaguely inferred as real gas effects. For the purpose of practical use of high-pressure hydrogen gas, systematic research is required to clarify the critical nozzle flow of high-pressure hydrogen gas. In the present study, a computational fluid dynamics(CFD) method has been applied to predict the critical nozzle flow of high-pressure hydrogen gas. Redlich-Kwong equation of state that take account for the forces and volume of molecules of hydrogen gas were incorporated into the axisymmetric, compressible Navier-Stokes equations. A fully implicit finite volume scheme was used to numerically solve the governing equations. The computational results were validated with some experimental data available. The results show that the coefficient of discharge coefficient is mainly influenced by the compressibility factor and the specific heat ratio, which appear more remarkable as the inlet total pressure of hydrogen gas increases.

  • PDF

Estimating Nutrients Delivery Ratios at the Subwatershed Scale -A Case Study at the Bochung-A Watershed- (소유역 유달율 추정공식 개발 -보청A유역을 중심으로-)

  • Jeon, Ji-Hong;Choi, Dong-Hyuk;Lim, Kyung-Jae;Kim, Tae-Dong
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.52 no.5
    • /
    • pp.27-35
    • /
    • 2010
  • The characteristics of delivered nutrient loads were analyzed and the regression equations to estimate delivery ratios of nutrients (TN and TP) were developed using HSPF simulation results at six subwatersheds within the Bochung A unit watershed during 1998-2007. TN delivery ratio was higher than TP delivery ratio because significant amounts of TP was considered to be attached at soil as ${PO_4}^-$ during delivery process from discharged point of nutrient source to main stream. As a results of correlation analysis, factors related to geomorphic characteristics had not statistical correlation with TN and TP delivery ratios. TN loading rate from living and specific stream flow had statistical negative and positive correlation, respectively, with TN delivery ratio. TP loading rates from all sources and from land cover and specific stream flow had statistical negative, negative and positive correlation, respectively. The specific stream flow represents the most strong correlation with nutrient delivery ratios. The regression equations to estimate delivery ratios for TN and TP were developed by including statistical correlated factors and showed high efficiency of 0.98 and 0.95 of coefficient of determination for TN and TP, respectively.

Mass transfer characteristics of benzene in nonpolar solution (비극성용매 내의 벤젠 물질전달특성)

  • 최성우;김혜진;박문기
    • Journal of Environmental Science International
    • /
    • v.11 no.6
    • /
    • pp.605-610
    • /
    • 2002
  • The absorption of benzene in nonpolar solution was studied in a laboratory-scale of bubble column varying of gas flow rates and gas-to-liquid ratios. A bubble column had a 0.8∼l$\times$10$\^$-3/ m$^3$ total volume (height 1500 mm, diameter 50 mm). Solution analysis was performed by GC-FID and GC-MSD. The objectives of this research were to select the best absorption fluid and to evaluate the mass transfer characteristics under specific conditions of each absorption. The results of this research were follow as: First, the heat transfer fluid is more efficient than the other nonpolar solution in removing VOC. Second, The benzene removal efficiency improved according to an increasing rate of gas flow. Also, volumetric mass transfer rate of column can be enhanced by increasing gas flow rate. Finally, the relation of gas flow rates, liquid amount, and volumetric mass transfer coefficient was obtained as follows. K$\_$y/a: 0.5906(V$\_$g//L)$\^$0.7611/ The following correlation of mass transfer coefficient and efficiency was proposed. v= 0.06078 K$\_$y/a$\^$0.2444/.

Performance Improvement of a Micro Eco Cross-Flow Hydro Turbine

  • Kokubu, Kiyoshi;Kanemoto, Toshiaki;Son, Sung-Woo;Choi, Young-Do
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.36 no.7
    • /
    • pp.902-909
    • /
    • 2012
  • This study is aimed to develop a new type of micro cross-flow hydro turbine which has very simple structure and relatively high efficiency. Micro eco cross-flow hydro turbine (ECFT) is proposed to apply in the ranges of very low and middle specific speeds in order to extend the operational range of the turbine. In order to not only obtain a basic data for a new design method of ECFT but also improve the turbine efficiency, experiments and CFD analysis on the performance and internal flow characteristics of the turbine model are conducted. According to the present study results, anti-recirculation block (ARB) and relatively wide turbine width with high flow rate improve the turbine efficiency.