• 제목/요약/키워드: Special moment building

검색결과 52건 처리시간 0.023초

모멘트-연성 강구조물의 내진설계를 위한 반응수정계수의 평가 (Evaluation of Response Modification Factore for Earthquake Resistant Design of Moment-Resisting Steel Frames)

  • 송종걸
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 1997년도 추계 학술발표회 논문집 Proceedings of EESK Conference-Fall 1997
    • /
    • pp.201-208
    • /
    • 1997
  • In most seismic codes such as the Uniform Building Code(UBC), the response modification factor(or the force reduction factor)is used to reflect the capability of a structure in dissipating energy through inelastic behavior. The response modification factor is assigned according to structural system type. Ductile systems such as special moment-resisting steel frames are assigned larger values of the response modification factor, and are consequently designed for smaller seismic design forces. Therefore, structural damage may occur during a severe earthquake. To ensure safety of the structures, the suitability of the response modification factor used in aseismic design procedures shall be evaluated. The object of this study is to develop a method for the evaluating of the response modification factor. The validity of the evaluating method has been examined for several cases of different structures and different earthquake excitations.

  • PDF

양단단순-타단자유 지지된 적층복합판의 처짐에 대한 종방향 모멘트 무시효과 (The Effect of Neglecting The Longitudinal Moment Terms on The Deflection of Laminated Plates with a Pair of Opposite Edges Simple Supported and The Other Pair of Opposite Edges Free)

  • 김덕현;원치문;심도식;이원석
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1998년도 가을 학술발표회 논문집
    • /
    • pp.77-83
    • /
    • 1998
  • The most of the design engineers for construction has academic background of bachelors degree. Theories for advanced composite structures are too difficult for such engineers and some simple but accurate enough methods are necessary. The senior author has reported that some laminate orientations have decreasing values of B$_{16}$, B$_{26}$, D$_{26}$, and D$_{26}$ stiffnesses as the ply number increases. Such plates above behave as special orthotropic plates and simple formulas developed by the senior author[1, 3] can be used. Most of the bridge and building slabs on girders have large aspect ratios. For such cases further simplification is possible by neglecting the effect of the longitudinal moment terms(M$_{x}$) on the relevant partial differential equations of equilibrium. In this paper, the result of the study on the subject problem is presented.ted.d.

  • PDF

Evaluating the reliability of using the deflection amplification factor to estimate design displacements with accidental torsion effects

  • Lin, Jui-Liang;Wang, Wei-Chun;Tsai, Keh-Chyuan
    • Earthquakes and Structures
    • /
    • 제8권2호
    • /
    • pp.443-462
    • /
    • 2015
  • Some model building codes stipulate that the design displacement of a building can be computed using the elastic static analysis results multiplied by the deflection amplification factor, $C_d$. This approach for estimating the design displacement is essential and appealing in structural engineering practice when nonlinear response history analysis (NRHA) is not required. Furthermore, building codes stipulate the consideration of accidental torsion effects using accidental eccentricity, whether the buildings are symmetric-plan, or asymmetric-plan. In some model building codes, the accidental eccentricity is further amplified by the torsional amplification factor $A_x$ in order to minimize the discrepancy between statically and dynamically estimated responses. Therefore, this warrants exploration of the reliability of statically estimated design displacements in accordance with the building code requirements. This study uses the discrepancy curves as a way of assessing the reliability of the design displacement estimates resulting from the factors $C_d$ and $A_x$. The discrepancy curves show the exceedance probabilities of the differences between the statically estimated design displacements and NRHA results. The discrepancy curves of 3-story, 9-story, and 20-story example buildings are investigated in this study. The example buildings are steel special moment frames with frequency ratios equal to 0.7, 1.0, 1.3, and 1.6, as well as existing eccentricity ratios ranging from 0% to 30%.

Numerical investigation on seismic behaviors of midrise special moment resistant frame retrofitted by timber-base bracings

  • Ainullah-Mirzazadah, Ainullah-Mirzazadah;Sabbagh-Yazdi, Saeed-Reza
    • Steel and Composite Structures
    • /
    • 제45권1호
    • /
    • pp.83-100
    • /
    • 2022
  • Timber is one of the few natural, renewable building materials and glulam is a type of engineering wood product. In the present work, timber-based braces are applied for retrofitting midrise Special Moment Resisting Frame (SMRF) using two types of timber base braces (Timber base glulam, and hybrid Timber-Steel-BRB) as alternatives for retrofitting by traditional steel bracings. The improving effects of adding the bracings to the SMRF on seismic characteristics of the frame are evaluated using load-bearing capacity, energy dissipation, and story drifts of the frame. For evaluating the retrofitting effects on the seismic performance of SMRF, a five-story SMRF is considered unretofitted and retrofitted with steel-hollow structural section (HSS) brace, Glued Laminated Timber (Glulam) brace, and hybrid Timber-Steel BRB. Using OpenSees structural analyzer, the performance are investigated under pushover, cyclic, and incremental loading. Results showed that steel-HSS, timber base Glulam, and hybrid timber-steel BRB braces have more significant roles in energy dissipation, increasing stiffness, changing capacity curves, reducing inter-story drifts, and reducing the weight of the frames, compared by steel bracing. Results showed that Hybrid BRB counteract the negative post-yield stiffness, so their use is more beneficial on buildings where P-Delta effects are more critical. It is found that the repair costs of the buildings with hybrid BRB will be less due to lower residual drifts. As a result, timber steel-BRB has the best energy dissipation and seismic performance due to symmetrical and stable hysteresis curves of buckling restrained braces that can experience the same capacities in tension and compression.

보통과 중간 모멘트 골조 기둥의 내진거동 비교 (Seismic Behavior of Columns in Ordinary and Intermediate Moment Frames)

  • 한상환
    • 콘크리트학회논문집
    • /
    • 제17권1호
    • /
    • pp.51-58
    • /
    • 2005
  • 모멘트골조는 건물 골조로 많이 사용되어 왔다. 현행 설계기준에서는 콘크리트모멘트 골조를 보통, 중간 특수 모멘트저항 콘크리트 골조 (OMRCF, IMRCF, SMRCF)로 분류하고 있다. 본 연구의 목적은 OMRCF와 IMRCF 기둥의 내진성능을 비교 평가하는 것이다. 이 목적을 위하여 3층 사무소 용도의 OMRCF와 IMRCF를 ACI 318 (2002)와 KCI (1999)을 따라 설계하였다. 이 연구에서 건물들은 모두 UBC (1997)에서 분류한 지진지역 1에 위치하는 것으로 가정하였다. 이 연구에서는 1층의 기둥을 고려하였는데 이는 1층이 지진 발생시 가장큰 횡력과 축력을 부담하기 때문이다. 8개의 2/3 축소모델 실험체를 제작하였다. 각 실험체는 각각 OMRCF 와 IMRCF 내부와 외부의 기둥 상부 하부를 모델링한 것이다. 유사정 적가력을 하였고 축력은 외부기둥실험체에는 변동축력을 내부기둥실험체에는 고정축력을 가력하였다. 본 연구결과에 따르면 겹침이음여부, 축력의크기, 기둥단부의 횡보강근은 기둥의 내진거동에 영향을 주는 것으로 나타났다. 하지만 이러한 변수들은 서로 관련되어 있는 것으로 나타났다.

TLCD를 이용한 지진하중을 받는 3차원 비정형 건축구조물의 응답제어 (RESPONSE CONTROL OF 3D IRREGULAR BUILDINGS UNDER SEISMIC EXCITATIONS USING TLCD)

  • 김홍진;김형섭;안상경
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 추계학술대회논문집
    • /
    • pp.66-71
    • /
    • 2003
  • The semi-active TLCD system is investigated for control of responses of 3D irregular buildings under seismic excitations. The TLCD system is a special type of TMD system providing a performance similar to a TMD system but offers a number of practical advantages over the traditional TMD system. The equations of motion for the combined building and TLCD system are derived for multistory building structures with rigid floors and plan and elevation irregularities. Simulation results for control of two multistory moment-resisting space structures with vertical and plan irregularities show clearly that the semi-active TLCD control system reduces the responses of 3D irregular buildings subjected to earthquake ground motions efficiently.

  • PDF

상·하부 스플릿 T 접합부의 초기회전강성 예측모델 (Prediction Model for the Initial Rotational Stiffness of a Double Split T Connection)

  • 양재근;김윤;박재호
    • 한국강구조학회 논문집
    • /
    • 제24권3호
    • /
    • pp.279-287
    • /
    • 2012
  • 상 하부 스플릿 T 접합부는 T-stub의 두께, 고력볼트 게이지 거리 등의 주요 변수 조합에 따라서 보통모멘트골조 혹은 특수모멘트골조에 적합한 접합부로 사용된다. 상 하부 스플릿 T 접합부가 안전한 구조거동을 발휘하기 위해서는 건축구조기준에서 규정한 층간변위각 및 접합부모멘트에 대한 요구사항을 만족하여야 한다. 이러한 요구사항 조건의 충족여부를 파악하기 위해서는 접합부의 회전강성 및 한계소성모멘트에 대한 예측이 필수적이다. 따라서 이 연구는 일차적으로 정적하중을 받는 상 하부 스플릿 T 접합부의 회전강성 예측을 위한 해석모델 제안을 위하여 진행하고자 한다. 이를 위하여 3차원 비선형 유한요소해석을 수행하였다. 제안한 해석모델의 적용 적합성은 기존의 해석모델 및 실험결과와 비교 검토하여 입증하였다.

화령전의 제례의식과 건축특성에 관한 연구 (A Study on the Ritual Ceremony and the Architectural Form of Hwaryeong-Jeon in the Joseon Dynasty)

  • 김동욱;조옥연;정춘환
    • 건축역사연구
    • /
    • 제14권1호
    • /
    • pp.57-70
    • /
    • 2005
  • This study is the consideration about Hwaryeong-Jeon that enshrines Joseon Dynasty 22nd king Jeongjo's portrait of a king. Suwon's Hwaryeong-Jeon that accompanied a portrait and performed ritual ceremonies had several formalities and ceremonies which are connected with rituals. therefore, we will try to examine what relation between arrangement of building and plane composition had. And through this, it is thing to observe construction special quality that Hwaryeong-Jeon has. Joseon Dynasty's young-jeon (a hall where the royal portraits are kept) is retaining each other different state according to construction age every moment. Hwaryeong-Jeon among Joseon Dynasty's a hall of royal portraits is the construction form which is equiped well and is known for keeping the form well from the foundation to now And this building is evaluated as the standard form of early part young-jeon building of 19th century. Especially, Hwaryeong-Jeon shows the typical ritual equipments late Joseon Dynasty and at the same time has all kinds of characteristics which only we can find at Hwaryeong-Jeon. Namely, Hwaryeong-Jeon is the building which brings the design concept of the hall of royal portraits to completion as the building which enshrines single portrait of a king. After all, Hwaryeong-Jeon is evaluated as the building which can pass excellent form of late Joseon Dynasty, the hall of royal portraits building just as it is. Therefore, as I study its own style, I expect Joseon Dynasty's mind that enshrined the portrait of a king elaborately to be revealed.

  • PDF

Development and testing of cored moment resisting stub column dampers

  • Hsiao, Po-Chien;Lin, Kun-Sian;Liao, Wei-Chieh;Zhu, Limeng;Zhang, Chunwei
    • Steel and Composite Structures
    • /
    • 제34권1호
    • /
    • pp.107-122
    • /
    • 2020
  • Moment resisting stub columns (MRSCs) have increasingly adopted in special moment-resisting frame (SMF) systems in steel building structures, especially in Asian countries. The MRSCs typically provide a lower deformation capacity compared to shear-panel stub columns, a limited post-yield stiffness, and severe strength degradation as adopting slender webs. A new MRSC design with cored configuration, consisting of a core-segment and two side-segments using different steel grades, has been proposed in the study to improve the demerits mentioned above. Several full-scale components of the cored MRSC were experimentally investigated focusing on the hysteretic performance of plastic hinges at the ends. The effects of the depths of the core-segment and the adopted reduced column section details on the hysteretic behavior of the components were examined. The measured hysteretic responses verified that the cored MRSC enabled to provide early yielding, great ductility and energy dissipation, enhanced post-yield stiffness and limited strength degradation due to local buckling of flanges. A parametric study upon the dimensions of the cored MRSC was then conducted using numerical discrete model validated by the measured responses. Finally, a set of model equations were established based on the results of the parametric analysis to accurately estimate strength backbone curves of the cored MRSCs under increasing-amplitude cyclic loadings.

Cyclic behavior of jumbo reduced beam section connections with heavy sections: Numerical investigation

  • Qi, Liangjie;Liu, Mengda;Shen, Zhangpeng;Liu, Hang
    • Earthquakes and Structures
    • /
    • 제23권2호
    • /
    • pp.183-196
    • /
    • 2022
  • Reduced beam section (RBS) moment connections used in special moment resisting frames are currently limited to beam sections that are not larger than nominal depths of 920 mm, weight of 447 kg/m and flange thickness of 44 mm. Due to the higher demand for structural components with jumbo sections, which can potentially be applied in the transfer girders in long-span building structures, the newly available steel heavy members are promising. To address this issue, advanced numerical models are developed to fully evaluate the distribution of stresses and concentrations of plastic strains for such jumbo RBS connections. This paper first presents a brief overview of an experimental study on four specimens with large beam and column sections. Then, a numerical model that includes initial imperfections, residual stresses, geometric nonlinearity, and explicitly modeled welds is presented. The model is used to further explore the behavior of the test specimens, including distribution of stresses, distribution of plastic strains, stress triaxiality and potential for fracture. The results reveal that the stresses are highly non-uniform across the beam flange and, similarly, the plastic strains concentrate at the extreme fiber of the bottom flange. However, neither of these phenomena, which are primarily a function of beam flange thickness, is reflected in current design procedures.