• 제목/요약/키워드: Spatting

검색결과 59건 처리시간 0.02초

폴리프로필렌 섬유의 혼입률 및 부재크기 변화에 따른 콘크리트의 내화 특성 (Properties of Fire Resistance of Concrete with Contents of Polypropylene Fiber and Specimens Size)

  • 전선천;황인성;이병열;양성환;한천구
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2001년도 봄 학술발표회 논문집
    • /
    • pp.463-468
    • /
    • 2001
  • A lot of considerations on the spatting by fire of high performance concrete should be taken into for fire resistance of the concrete structures. In this paper, fire resistance of high performance concrete is described using polypropylene fiber, which is known to be contributed to fire resistance. Strength level and member size are varied with. According to test results, spatting by fire takes place more easily, as W/C increases and member size decreases. It shows that concrete containing polypropylene fiber has good effects on preventing spatting by fire. In case high performance concrete does not contain polypropylene fiber, residual strength shows to be decreased remarkably compared :o that of normal concrete. Whereas, in case 0.1% of polypropylene fiber contents, high performance concrete shows higher residual strength than that of normal concrete. As member size is smaller, residual strength shows to be decreased.

  • PDF

고성능 콘크리트의 폭렬방지 공법 현장적용 사례 (Field Application of Spalling Prevention Method of High Performance Concrete)

  • 김경민;허영선;이재삼;지석원;이성연;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2005년도 추계 학술논문 발표대회
    • /
    • pp.7-10
    • /
    • 2005
  • This paper is about manufacture of spalling resistance concrete and also investigates the spalling mechanism and spalling resistance method with diverse materials, mixture proportion and lateral confinement. The present work with the basic experiment achieved successful method for spatting resistance using both proper amounts of fiber contents and lateral confinement using metal lath. Moreover, the developed spatting resistance method was applied for full sized column construction in the Doosan We've Poseidon I field, located in Busan city. The author investigated the physical properties examining workability, placeability and pumpability. These studies are continuously processing to develop new technology expecting remarkable impact on the spatting resistance and fire resistance performance of high-raise building construction in the future.

  • PDF

무전해 Ni(P)과 무연솔더와의 반응 중 금속간화합물의 spalling 현상에 관한 연구 (Spalling of Intermetallic Compound during the Reaction between Electroless Ni(P) and Lead-free Solders)

  • 손윤철;유진한;강성권;;이택영
    • 마이크로전자및패키징학회지
    • /
    • 제11권3호
    • /
    • pp.37-45
    • /
    • 2004
  • 무전해 Ni(P)는 솔더링 특성과 부식저항성이 우수하고 표면 거칠기가 적으며 원하는 금속 상에 선택적으로 도금이 가능하여 전자패키지에서 반도체칩과 기판의 표면 금속층으로 촉 넓게 사용되고 있다. 그러나 솔더와의 반응 중 금속간 화합물의 spalling과 솔더 조인트에서의 취성파괴 문제가 성공적인 적용의 걸림돌이 되어 왔다. 본 연구에서는 각각 조성이 다른 세가지 Ni(P)막 (4.6,9, and $13 wt.\%$ P)을 사용하곡 솔더와의 반응시 무전해 Ni(P)막의 미세구조 및 상 변화와 금속간화합물의 spatting 거동을 면밀히 조사하였다. $Ni_3Sn_4$ 화합물 아래로 침투한 Sn과 P-rich layer ($Ni_3P$)와의 반응에 의해 $Ni_3SnP$ 층이 형성되며 $Ni_3SnP$ 층이 성장함에 따라 $Ni_3Sn_4$가 spalling됨이 관찰되었다. Spalling 후에는 Ni(P)막이 용융된 솔더와 직접 접촉하게 되어 Ni(P)막의 결정화가 가속화되고 $Ni_3P$상이 $Ni_2P$상으로 변태되었다. 또한 이러한 결정화 과정 중 Ni(P)막의 부피가 감소됨에 따라서 인장응력이 발생하여 막 내부에 크랙이 발생하였다.

  • PDF

혼화재 종류 및 섬유 혼입률 변화에 따른 고강도 콘크리트의 내화특성 (Fire Resistance Properties of High Strength Concrete Made with Various Admixture Types and Fiber Content)

  • 장기현;배장춘;김호림;지석원;양성환;한천구
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2007년도 춘계학술논문 발표대회
    • /
    • pp.63-66
    • /
    • 2007
  • This study investigates the fire resistance properties of high strength concrete, around 60MPa class, designed with various admixture types and fiber content. Test showed that the increase of fiber content decreased the fluidity and slightly inclined the air content of fresh concrete. However, the fiber content in concrete did not affect the compressive strength. For the addition of admixture, specimens adding the shrinkage-reducing-agent (SR) indicated the strength value at 70MPa, which is followed by incorporating silica fume (SF) at 66MPa, the combination of expansive admixture (EA) and SR at 63MPa, only EA at 59MPa, blast furnace slag (BS) at 58MPa and fly ash (FA) at 50MPa in an order. After completing the fire test, all specimens adding 0.05vol.% of polypropylene fiber exhibited protection of spatting, except for the specimens incorporating loft of SF and incorporating 20% of SF with only SR and the combination of EP and SRA, respectively. Therefore the most effective result of this study was shown in the specimens incorporating love of FA and 30% of BS and incorporating 20% of SF with 5 % of EA. It is expected that this test results will be crucial references in near future to develope the spatting resistance method of high strength concrete.

  • PDF

터널 화재로 인한 콘크리트 세그먼트의 손상특성 규명 (Eire-induced Damage to Shield TBM Concrete Segment)

  • 최순욱;장수호;이규필;배규진
    • 한국지반공학회논문집
    • /
    • 제21권5호
    • /
    • pp.171-177
    • /
    • 2005
  • 지하공간에서의 화재는 인명 및 재산피해 뿐만 아니라 지하구조물에 심각한 손상을 발생시킨다. 이러한 화재로부터 구조물을 보호하기 위해서 화재에 의한 지하구조물 시공재료의 손상을 파악하는 것은 매우 중요한 사항이다. 본 연구에서는 화재에 의한 지하구조물의 손상을 파악하기 위하여 지하공간 화재모의시험 가열로를 제작하였고, 쉴드 TBM 콘크리트 세그먼트시편에 대하여 모의 화재실험을 수행하였다. 수행된 실험은 5분에 $1,200^{circ}C$에 도달하여 1시간동안 유지한 후 2시간에 걸쳐 소화되는 RABT곡선을 모사하였다. 시험체내에 설치된 온도센서로 확인한 결과, 화재면으로부터 약 20cm까지 폭렬이 발생하였다. 또한 시험이 완료된 블럭시편으로부터 채취된 코어시편에 수행된 물리$\cdot$화학적 실험을 통하여 폭렬면으로부터 약 l0cm까지 시공재료의 특성이 저하되었음을 확인하였다.

섬유의 종류 및 온도가열곡선 변화에 따른 콘크리트의 내화특성 (Fire Resistance of the Concrete Corresponding to the Various Fiber Contents and Heating Curves)

  • 한천구;배장춘
    • 한국건축시공학회지
    • /
    • 제8권5호
    • /
    • pp.101-107
    • /
    • 2008
  • This study investigated fundamental characters of the concrete according to various fiber types and contents and their properties of spatting resistance and residual compressive strength after fire test corresponding to ISO and RABT heating corves. The results were summarized as following. The Flowability was gradually declined as the increase of fiber contents, and it was the most favorable with nylon(NY) fibers. The decrease of air contents due to increasing fiber contents was in order by polypropylene(PP), polyvinyl alcohol(PVA) and NY fibers. The compressive strengths were over 40 MPa at 7 days and 50 MPa at 28 days. It was in order by PVA, PP and NY fibers. For the spatting properties, all specimens were prevented at ISO heating curve. In the other hand, the partial spatting at the surface occurred on the plain without fibers, but it was prevented over 0.10 % of PVA and 0.05 % of PP and NY fibers at the RABT heating curve.

중심 축하중을 받는 고강도 RC기둥의 섬유 혼입량에 따른 폭열 및 내화 성상 (Spatting and Fire Enduring Properties of High Strength RC Column Subjected to Axial Load Depending on Fiber Contents)

  • 한천구;황인성;이재삼;김경민
    • 콘크리트학회논문집
    • /
    • 제18권1호
    • /
    • pp.83-90
    • /
    • 2006
  • 본 연구는 PP 및 CL 섬유 혼입량 변화에 따라 제작한 고성능 K 기둥부재를 대상으로 화재를 상정한 내화시험 후 폭열 방지 및 내화성능을 검토한 것으로, 그 실험결과를 요약하면 다음과 같다. 굳지않은 콘크리트의 특성으로, PP 및 CL섬유 혼입량 증가에 따른 유동성은 섬유의 엉킴현상 등에 의해 플레인보다 저하하였고, 공기량은 다소 증감의 차이는 있으나 모두 목표 공기량의 범위를 만족하였으며, 경화 콘크리트의 압축강도는 섬유 혼입량 변화에 따라 50 MPa 전후의 고강도로 나타났다. 내화시험 후 RC 기둥부재의 폭열특성으로, 섬유를 혼입하지 않은 플레인은 전체적으로 심한 파괴폭열이 발생하여 철근이 노출되었고, PP섬유를 혼입한 경우는 내부 수증기압의 효과적인 배출로 폭열이 방지되었으며, CL섬유는 플레인보다 폭열 방지효과는 있으나, 모서리 부분에서 일부 파괴폭열이 발생하였다. 또한, 내화시험 후 폭열깊이는 표면보다 모서리에서 더 깊게 나타났고, 폭열발생면적율은 폭열방지 성능과 관계하여 PP섬유를 혼입한 경우가 가장 양호하였으며, 중성화깊이는 $6{\sim}8mm$ 전후의 유사한 깊이로 나타났다. 내화시험 후 잔존 압축강도율은 PP섬유를 혼입한 경우 40% 전후로 플레인의 20% 보다 크게 나타났고, CL섬유를 혼입한 경우는 25% 전후로 플레인과 큰 차이가 없었다.