• 제목/요약/키워드: Spatial type

Search Result 1,978, Processing Time 0.036 seconds

A Three-Set Type Korean Keyboard Model, 38K, with High Compatibility to the KS Computer Keyboard

  • Kim, Kuk
    • Journal of the Ergonomics Society of Korea
    • /
    • v.33 no.5
    • /
    • pp.355-363
    • /
    • 2014
  • Objective:The purpose of this study is to design a three-set type (Sebulsik) keyboard that is to input Korean text with no shifted keys and also compatible with the standard Korean computer keyboard or ANSI keyboard. Background: The KS computer keyboard is two-set type (Dubulsik). Existing and proposed designs of three-set type of past studies are not compatible with KS or ANSI keyboard and are complex with many redundant letters. Method: The number of Korean letters for 3-set type is analyzed. Then Korean letters are arranged with normality and with spatial compatibility to the KS Korean keyboard, and symbols were arranged to same positions with ANSI keyboard. Results: Initial consonants of 14 numbers and 6 vowels are arranged as exactly same positions of KS keyboard, and other vowels are arranged with spatial compatibility. Symbols are arranged to the same positions with ANSI keyboard, and 10 digits are confirmed and has compatibility to International standard. Conclusion: A 38-key model, 38K, is designed to require minimal keys to input Korean text with no shifted keys, increased the compatibility to the KS Korean computer keyboard. Application: Using the proposed 38-key model, 38K, it can be taken into account for keyboards in industrial production. It is applicable to user group of 3-set type Korean keyboard with more easy than past keyboards.

A Study on the Spatial Configuration of Internal Functions of Public Area in City Hotels - Focusing on middle size first-class hotels in Korea and Japan - (도시 호텔 공용부문에 나타난 내부기능구성형식에 관한 연구 - 한국과 일본의 중규모 특급호텔을 중심으로 -)

  • 이창노
    • Korean Institute of Interior Design Journal
    • /
    • v.13 no.5
    • /
    • pp.125-132
    • /
    • 2004
  • The purpose of this study is focused on defining the types of spatial configuration of internal functions in city hotels by researching and analyzing city hotels in Korea and Japan. The scope of this study is limited to the period of early 1980's to the end of 1990's and 18 city hotels in Korea and Japan are selected as subject. Researching existing records and analyzing plans, surveys are used as the method of the study. The result of this study is as follow. First, block composition of floor plans that is used for hotel construction could be divided into three types (immanent type-6hotels, combined type-7hotels, adjacent type-4hotels). Second, the result of analysis about the internal functions and structural types of public area in city hotels is as follow. More Korean city hotels are taking concourse type (Korea 77.8%, Japan 55.6%) and hall type (Korea 22.2%, Japan 11.1%) than Japanese city hotels. However, the mixed type (concourse type +hall type) is only used in Japan (Korea 0%, Japan 33.3%). Third, as the result of the comparison of the size of public area between Korea and Japan, Korean hotels (36.70%) have larger space than Japanese hotels only in the service area. public (Korea 33.98% < Japan 34.71%), business (Korea 27.68% Japan 31.41%)and empty (Korea 1.64% < Japan 6.13%) area is taking larger space in Japanese city hotels than Korean.

A Study on Effect of the Junction's Eccentricity for Buckling Characteristics of Single-Layer Latticed Dome (접합부 편심을 고려한 단층 래티스돔의 좌굴특성에 관한 연구)

  • Park, Sang-Hoon;Suk, Chang-Mok;Jung, Hwan-Mok;Kwon, Young-Hwan
    • Journal of Korean Association for Spatial Structures
    • /
    • v.1 no.1 s.1
    • /
    • pp.117-124
    • /
    • 2001
  • In Single-layer latticed domes with rectangular network which is composed of ring of circumferential direction and rafter of longitudinal direction, that is, rib domes, if we use the cross-membered junction's method for the advantage in fabrication and construction, the eccentricity is occurred in the nodal point of crossing members. This paper is aimed at investigating the buckling characteristics for the effect of eccentricity according to rise-span ratios and distance of eccentricity. Analysis method is based on FEM dealing with the geometrically nonlinear deflection problems. The conclusion were given as follows: 1. The maximum decreasing ratio of buckling strength due to the junction's eccentricity is about 60% in models of this paper. 2. In the increasing ratio of buckling strength for rise-span ratio, that of Type 3 models is larger than that of type 2 models. On the other hand, that of Type 2 mode is larger than that of Type 3 for eccentricity-distance. 3. In the viewpoint of the value of buckling strength, that of Type 2 models is larger than that of type 3 models. The effect of the junction's rigidity on buckling strength is not great for overall models. Therefore if we use the cross-membered junction's method for the advantage in fabrication and construction, the method of Type 2 will have the great advantage of that of Type 3.

  • PDF

A study on the Spatial Arrangement and Area of Senior Sharehouses in Japan (일본의 시니어 쉐어하우스 공간배치 및 면적 연구)

  • Ju, Hyun-Jin;Moon, Jeong-Min
    • Journal of the Korean housing association
    • /
    • v.26 no.2
    • /
    • pp.13-20
    • /
    • 2015
  • Single household is expected to be the typical form of future Korean elderly household from reduction of household size and rapid growth of the elderly. As Japanese solve the same problem with Senior Sharehouse, a case study on Senior Sharehouse in japan focused on the Spatial Arrangement and Spatial Composition could suggest an potential applications in Korea. In conclusion, compare to Korea, the Senior Sharehouse in Japan supplies additional $7.5{\sim}9.3m^2$ more space to support the physical movement of the elderly and to help the elderly to solve various functions at one space. The independence and privacy of residents are also assured by supplying single occupancy. Space analysis shows that public space is as spacious (47.3~55%) as personal space. The result of the Space analysis suggests that the sharehouse provides rational ratio of space to assure residents' independence. It was supposed that the center type would be the main stream of the Spatial Arrangement for sharehouse considering its characteristic of sharing space. But, the Senior Sharehouse in Japan prefers corner type. The guarantee of personal space is being considered as a important characteristic. As a result of case analysis, Senior Sharehouse can be a proper type of house for single elderly household and present study can be used for the baseline data to solve the residence problem for single elderly household in Korea.

A Study on Spatial Configuration of Central Medical Treatment Part and Outpatient Part at Geriatric Hospital according to Function and Corridor Type (기능과 복도유형에 따른 요양병원 외래진료부·중앙진료부의 공간구조특성에 관한 연구)

  • Bae, Sunmi;Yoon, Sohee;Kim, Suktae
    • Journal of The Korea Institute of Healthcare Architecture
    • /
    • v.21 no.2
    • /
    • pp.7-15
    • /
    • 2015
  • Purpose: The purpose of this study is analyze linkage and spatial and structural characteristics of outpatient department and diagnosis/treatment area of geriatric hospitals based on quantitative analysis, according to function and corridor types. Methods: To examine structural characteristics and correlation of outpatient department and diagnosis/treatment area of six geriatric hospitals according to the corridor type, were systemized according to the function and corridor type and made into a j-graph, and an index was created by using space syntax to understand spatial characteristics. Results: 1) Different functional spaces are connected by a corridor, which, therefore, can be an axis of the connectivity and linkage of functional spaces and an important element in a clear hierarchy. 2) Treatment areas were disconnected from different functional spaces and, therefore, the accessibility was low. Many hospitals had an arrangement plan for treatment and diagnosis areas, and recent hospitals have segmented treatment areas within the rehabilitation space, which resulted in deeper space. 3) In terms of the level of integration, more integrated reception area meant shallower spatial depth, and deeper space for treatment and diagnosis areas. Implications: Spatial relation of outpatient department of geriatric hospitals was analyzed based on characteristics of the elderly.

The Instruction Flash memory system with the high performance dual buffer system (명령어 플래시 메모리를 위한 고성능 이중 버퍼 시스템 설계)

  • Jung, Bo-Sung;Lee, Jung-Hoon
    • Journal of the Korea Society of Computer and Information
    • /
    • v.16 no.2
    • /
    • pp.1-8
    • /
    • 2011
  • NAND type Flash memory has performing much researches for a hard disk substitution due to its low power consumption, cheap prices and a large storage. Especially, the NAND type flash memory is using general buffer systems of a cache memory for improving overall system performance, but this has shown a tendency to emphasize in terms of data. So, our research is to design a high performance instruction NAND type flash memory structure by using a buffer system. The proposed buffer system in a NAND flash memory consists of two parts, i.e., a fully associative temporal buffer for branch instruction and a fully associative spatial buffer for spatial locality. The spatial buffer with a large fetching size turns out to be effective serial instructions, and the temporal buffer with a small fetching size can achieve effective branch instructions. According to the simulation results, we can reduce average miss ratios by around 77% and the average memory access time can achieve a similar performance compared with the 2-way, victim and fully associative buffer with two or four sizes.

The CGH in the Electro-holographic system using the Bragg type AOSLM (Bragg type 음향광변조기를 채택한 Electro-holographic system에서의 computer generated Fresnel hologram의 구현)

  • ;;;;Tru Thi Van Anh
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 2002.07a
    • /
    • pp.142-143
    • /
    • 2002
  • KIST에서는 Pulsed Laser를 사용하여 3차원 image를 재생할 수 있는 Electro-Holographic System을 만들어 CGH이미지를 구현하였다. CGH 이미지를 구현하기 위한 SLM (Spatial Light Modulator)으로 TeO$_2$ 결정의 Shear Mode 에서 동작하는 Bragg type의 다채널 AOSLM(Acousto-optic Spatial Light Modulator)이 사용되었다. 이 Bragg type 다채널 AOSLM에서는 광원이 특정 Bragg 각도로 입사하였을 때 다른 고위 차수는 억압되고 +나 -의 첫번째 차수의 회절 빔만이 형성된다. (중략)

  • PDF

Interferometric Synthetic Aperture Millimeter-wave Radiometer for the High Resolution Imaging

  • Kim, Yong-Hoon;Choi, Jung-Hee;Kang, Gum-Sil
    • Proceedings of the KSRS Conference
    • /
    • 1999.11a
    • /
    • pp.122-126
    • /
    • 1999
  • The imaging characteristics of a 2-D interferometric synthetic aperture radiometer, such as an angular resolution, depend largely on the type of an antenna array. In this paper, different array configurations of antenna are studied and compared with each array types to get more high resolution image in spatial. T-, X- and Y- types of antenna array are considered and the performances of each type are analyzed considering spatial resolution. The simulation results of candidate antenna types are presented in this paper. In case of Y-type the coverage area of the visibility function is wide and the angular resolution is high more than the others. X-type array shows the good performance for side lobe level.

  • PDF

Tensile Characteristics of ETFE Film According to the Specimen Type (시험편 형상에 따른 ETFE 필름재의 인장 특성)

  • Kim, Seung-Deog;Chu, Seok-Beom;Jang, Myung-Ho;Lee, Jeong-Hyun
    • Journal of Korean Association for Spatial Structures
    • /
    • v.17 no.4
    • /
    • pp.159-165
    • /
    • 2017
  • In this paper, uniaxial tensile tests of ETFE films with three kinds of thicknesses(100, 200, $250{\mu}m$) and two kinds of directions(machine direction & transverse direction) are performed and the tensile strength, the tensile strain at break and the Young's modulus of ETFE films are compared for two kinds of specimen types(2 & 5). It could be figured out that there are no significant difference between tensile strengths of two specimen types but the tensile strain at break and the Young's modulus of ETFE films are affected by the specimen types. And it is concluded that the uniaxial tensile test of specimen type 2 are more reliable than that of specimen type 5.

A Study on Spatial Composition of the Middle Schools in Gyeongnam Province (경상남도 내 중학교의 공간구성에 관한 연구)

  • Yang, Kum-Suek
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.9 no.1
    • /
    • pp.17-25
    • /
    • 2007
  • The purpose of this study is to clarify the actual conditions of layout type and territorial area of middle schools. This article discuses about the characteristics of the floor plan composition and the layout type of 30 middle schools in gyeongnam province. The results of this study are summarized as follows; 1) In facilities arrangement of middle schools, it shows diverse forms of arrangement from existing uniform straight type, however, most of schools do not being against the simple in their external space. Therefore, it requires an expansion of space size and facilities for the change of school life outside class. 2) Comparing to traditional middle school facilities, it occurs various types of plane and the area is somewhat expanded in the school with same class size, however, it needs to improve facility standards in its reality to deal with the change of future educational environment actively.

  • PDF