• 제목/요약/키워드: Spatial resolution

검색결과 2,523건 처리시간 0.027초

바람장의 공간적.시간적 해상도가 누출물질 확산에 미치는 영향 (Effects of Spatio-Temporal Resolution of Diagnostic Wind Field on the Dispersion of Released Substance)

  • 김영성
    • 한국대기환경학회지
    • /
    • 제16권4호
    • /
    • pp.327-338
    • /
    • 2000
  • complexity in atmospheric environment coupled with shoreline and complex terrain often causes local variations of meteorology that are distinct from those representative over larger surrounding area, These kinds of local variations are less significant in usual long-term environmental impact analyses dealing with continuous plume. The variations could however be crucial in predicting dispersion of toxic substance released in a relatively small area for a short duration. In the present paper the effects of spatial and temporal resolution of diagnostic wind field on the dispersion of the released substance are investigated by using a puff model. A hypothetical release scenario assumes that a substance is released from a location in the Yochon Industrial Estate and passively dispersed within a few-kilometer distance for an hour. The results show that diagnostic analysis could resolve more spatial variations to some extent by employing smaller grid size. The peak concentrations and puff trajectories obtained from spatially -and/or tmeporally -varing diagnostic wind field are found appreciably different from those obtained from uniform wind field. Attention to high-resolution wind field in the both spatial and temporal spaces is called in the consequence analysis of toxic substance release.

  • PDF

Bar 타겟을 이용한 DMC 영상의 공간해상력 검증 (Verification of Spatial Resolution in DMC Imagery using Bar Target)

  • 이태윤;이재원;윤부열
    • 한국측량학회지
    • /
    • 제30권5호
    • /
    • pp.485-492
    • /
    • 2012
  • 최근 디지털 항공영상 센서는 다양한 국가 공간정보기반구축에 큰 역할을 하고 있다. 하지만 고정밀의 신뢰성 있는 자료를 확보하기 위해서는 취득된 디지털영상에 대한 적절한 품질 평가 작업이 선행되어야 한다. 따라서 현재 관련분야의 연구가 국내외적으로 크게 주목을 받고 있다. 디지털카메라의 성능을 테스트하기 위한 영상해상력 검증용 테스트필드가 유럽과 미국 등에서 이미 설치 및 활용되고 있다. 이러한 테스트필드에는 카메라의 기하학적 성능분석을 위한 대공표지를 비롯하여 공간해상력 및 방사해상력 분석을 위한 다양한 형태의 타겟 역시 설치되어 있다. 본 연구에서는DMC 카메라의 공간해상력을 검증하기 위하여 영상에서 인식 가능한 크기의 바 타겟(bar target)을 제작 설치 후 항공촬영을 수행하였다. 연구에 사용된 DMC 영상의 이론적인 지상표본거리(GSD ; Ground Sample Distance)는 12cm 급으로, 촬영 비행방향과 비행방향의 직각방향에 대하여 보조영상과 집성영상에 대하여 각각 실제 해상력을 분석하였다. 연구결과 이론적인 해상력과 영상의 실제 해상력간의 차이는 약 0.6cm로 나타났으며, 블록의 가장자리에 위치한 영상에서 최대 1.5cm 정도로 나타났다.

자동 추적 윈도우를 이용한 방위각 추정 알고리즘에 개선에 관하여 (On the Improvement of Bearing Estimation Algorithm Using Automatic Tracking Window)

  • 윤병우;신윤기
    • 대한전자공학회논문지
    • /
    • 제27권12호
    • /
    • pp.1800-1809
    • /
    • 1990
  • This paper proposed a preprocessing algorithm which is named Automatic Tracking Window (ATW), which eliminates the effects of noises at spatial signals and spurious peaks at high-resolution algorithm in bearing estimation algorithm. This method estimates spatial spectrum by periodogram algorisdthm and hihg-resolution algorithm after preprocessing of spatial signal by automatically tracked window.

  • PDF

영역-점 회귀 크리깅 기반 다중센서 위성영상의 공간-분광 융합: 고해상도 적색 경계 및 단파 적외선 밴드 생성 실험 (Spatio-spectral Fusion of Multi-sensor Satellite Images Based on Area-to-point Regression Kriging: An Experiment on the Generation of High Spatial Resolution Red-edge and Short-wave Infrared Bands)

  • 박소연;강솔아;박노욱
    • 대한원격탐사학회지
    • /
    • 제38권5_1호
    • /
    • pp.523-533
    • /
    • 2022
  • 이 논문에서는 상호보완적인 공간 및 분광해상도를 가진 다중센서 위성영상을 이용하여 공간해상도와 분광해상도를 향상시키기 위해 영역-점 회귀 크리깅(area-to-point regression kriging, ATPRK) 기반의 2단계 spatio-spectral fusion method (2SSFM)을 제안하였다. 2SSFM은 ATPRK와 random forest 회귀 모형을 결합하여 다중센서 위성영상에서 높은 공간해상도를 갖는 분광 밴드를 예측한다. 첫 번째 단계에서는 다중센서 위성영상 사이의 공간해상도 차이를 감소시키기 위해 ATPRK 기반 공간 상세화를 수행한다. 두 번째 단계에서는 다중센서 위성영상 사이의 분광 밴드의 관계성을 정량화하기 위해 random forest를 이용한 회귀 모델링을 적용하였다. 2SSFM의 예측 성능은 적색 경계와 단파 적외선 밴드를 생성하는 사례 연구를 통해 평가하였다. 사례 연구에서 2SSFM은 실제 분광 밴드와 유사한 분광패턴을 보이면서 공간해상도가 향상된 적색 경계와 단파 적외선 밴드를 생성할 수 있었으며, 2SSFM가 고해상도 위성영상에서 제공하지 않은 분광 밴드 생성에 유용함을 확인할 수 있었다. 따라서 2SSFM을 통해 실제로 획득 불가능하지만 환경 모니터링에 효과적인 분광 밴드를 예측함으로써 다양한 분광 지수를 생성할 수 있을 것으로 기대된다.

변조전달함수를 이용한 컴퓨터 방사선영상의 감도 노출 분류에 따른 공간분해능 평가 (Evaluation of the Spatial Resolution for Exposure Class in Computed Radiography by Using the Modulation Transfer Function)

  • 성열훈
    • 디지털융복합연구
    • /
    • 제11권8호
    • /
    • pp.273-279
    • /
    • 2013
  • 본 연구에서는 변조전달함수(Modulation transfer function, MTF)를 이용한 컴퓨터 방사선영상의 감도 노출 분류에 따른 공간분해능을 평가하여 컴퓨터 방사선영상 획득의 기초자료로 제시하고자 하였다. 본 실험에서는 $100{\mu}mm$ 픽셀의 영상판을 이용하여 엣지법의 MTF를 측정하였다. 방사선 선질은 IEC 61267에서 권고하고 있는 RQA5를 이용하였다. X-선이 조사된 영상판은 감도 노출 분류를 50, 100, 200, 300, 400, 600, 800, 1200으로 각각 설정한 후 디지털 영상화하였다. 최종 획득된 영상들은 공인된 영상분석 프로그램인 image J와 Origin 8.0을 이용하여 MTF 50%와 10%를 구하여 평가하였다. 그 결과 감도 노출 분류 200에서 가장 우수한 MTF 50%($1.979{\pm}0.114lp/mm$)와 MTF 10%($3.932{\pm}0.041$)의 공간주파수를 구하였다. 따라서 골절 등과 같이 높은 공간분해능을 요구하는 질병진단에 유용할 것으로 사료된다.

The influence of different scan resolutions on the detection of proximal caries lesions

  • Ferreira, Liana Matos;Queiroz, Polyane Mazucatto;Santaella, Gustavo Machado;Wenzel, Ann;Groppo, Francisco Carlos;Haiter-Neto, Francisco
    • Imaging Science in Dentistry
    • /
    • 제49권2호
    • /
    • pp.97-102
    • /
    • 2019
  • Purpose: This study was conducted to evaluate the effect of different spatial resolutions of a photostimulable phosphor plate (PSP) radiography system on the detection of proximal caries lesions. Materials and Methods: Forty-five extracted human permanent teeth were radiographed using a PSP system (VistaScan Perio Plus) and scanned at the 4 resolutions (10 lp/mm, 20 lp/mm, 25 lp/mm, and 40 lp/mm) available in the system. Three independent examiners scored the images for the presence and absence of proximal caries lesions using a 5-point scale. The presence or absence of caries was confirmed by histological sections of the examined teeth (defined as the gold standard). Intra- and inter-observer reproducibility was calculated by the weighted kappa test. One-way analysis of variance with the post hoc Tukey test was used to compare the area under the receiver operating characteristic curve for the classifications made with each resolution. Results: For the detection of enamel lesions, the spatial resolution of 10 lp/mm was significantly superior to the other resolutions. However, the spatial resolution did not affect the detection of caries lesions in dentin (P>0.05). Conclusion: Spatial resolution may influence the accuracy of the detection of incipient caries lesions in radiographs with PSP plates. Images with low spatial resolution seem to be more appropriate for this purpose.

An Implementation of Change Detection System for High-resolution Satellite Imagery using a Floating Window

  • Lim, Young-Jae;Jeong, Soo;Kim, Kyung-Ok
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2002년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.275-279
    • /
    • 2002
  • Change Detection is a useful technology that can be applied to various fields, taking temporal change information with the comparison and analysis among multi-temporal satellite images. Especially, Change Detection that utilizes high-resolution satellite imagery can be implemented to extract useful change information for many purposes, such as the environmental inspection, the circumstantial analysis of disaster damage, the inspection of illegal building, and the military use, which cannot be achieved by low- or middle-resolution satellite imagery. However, because of the special characteristics that result from high-resolution satellite imagery, it cannot use a pixel-based method that is used for low-resolution satellite imagery. Therefore, it must be used a feature-based algorithm based on the geographical and morphological feature. This paper presents the system that builds the change map by digitizing the boundary of the changed object. In this system, we can make the change map using manual or semi-automatic digitizing through the user interface implemented with a floating window that enables to detect the sign of the change, such as the construction or dismantlement, more efficiently.

  • PDF

HYPERSPECTRAL IMAGING SPECTROMETER WITH A NOVEL ZOOMING FUNCTION

  • Choi Jin;Kim Tae Hyung;Kong Hong Jin;Lee Jong-Ung
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2005년도 Proceedings of ISRS 2005
    • /
    • pp.213-216
    • /
    • 2005
  • A novel hyperspectral imaging spectrometer controlling spatial and spectral resolution individually has been proposed. This imaging spectrometer uses a zoom lens as a telescope and a focusing element. It can change the spatial resolution fixing the spectral resolution or the spectral resolution fixing the spatial resolution. Here, we report the concept of the hyperspectral imaging spectrometer with the novel zooming function and the optical design of a zoom lens as the focusing element. By using lens module and third-order aberration theory, we have presented the initial design of four-group zoom lens with external entrance pupil. And the optimized zoom lens with a focal length of 50 to 150 mm is obtained from the initial design by the optical design software. As a result, the designed zoom lens shows satisfactory performances in wavelength range of 450 to 900 nm as a focusing element in an imaging spectrometer. Furthermore, the collimator lens of the imaging spectrometer is designed through the third-order aberration correction by using an iterative process.

  • PDF

섬광체와 평행구멍조준기가 감마프로브 영상에 미치는 영향에 관한 컴퓨터 시뮬레이션 (Computer Simulation for Effects of Scintillator and Parallel Hole Collimator on Gamma Probe Imaging)

  • 봉정균;김희중;이종두;권수일
    • 대한의용생체공학회:의공학회지
    • /
    • 제19권6호
    • /
    • pp.563-570
    • /
    • 1998
  • The purpose of this study was to investigate the effects of scintillator and collimator parameters that tradeoff between system sensitivity and spatial resolution. The parameters simulated using Monte Carlo program were scintillator thickness, colimator hole shape, septal thickness, and hole length. The results show that the sensitivity increases exponentially upto about 1 cm of scintillator thickness as the thickness increases. However the sensitivity is almost constant when the scintiallator is thicker than about 1 cm. The simulation of collimator hole shape shows that the hexagonal hole gives the best spatial resolution for the same system sensitivity. The system statical resolution is improved, as both collimator septal thickness and hole length increase, however that system sensitivity is rapidly decreased. In conclusion, The optimization of scintillator and collimator parameters using monte carlo simulation may be useful to develop a high-resolution miniature gamma probe.

  • PDF

High Spatial Resolution Imaging of the Contiguous Objects Using Sub-Y-Type Interferometric Synthetic Aperture Radiometer

  • Lee Ho-Jin;Park Hyuk;Kim Sung-Hyun;Choi Jun-Ho;Seo Seung-Won;Kim Yong-Hoon;Kang Gum-Sil
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2004년도 Proceedings of ISRS 2004
    • /
    • pp.53-56
    • /
    • 2004
  • Recently the interferometric synthetic aperture radiometer with sub-Y-type antenna array was suggested to improve the spatial resolution than that of conventional Y-type with the same number of antenna elements. The sub-Y-type performance has been reported under a point source target. In this paper, the performance of sub-Y-type is evaluated under contiguous objects. The angular resolution of sub-Y-type with 52 antennas was compared with that of Y-type with the 40 antennas. The images of sub-Y -type and Y-type array were simulated under the contiguous objects. The sub-Y-type showed higher resolution than Y-type in the simulation and experiments. The sub-Y-type has high spatial resolution than Y-type in case of contiguous source as well as single point source.

  • PDF