• Title/Summary/Keyword: Spatial Properties

Search Result 1,146, Processing Time 0.027 seconds

A Study on the Electrochemical Properties Fabrication Process of Mg-Ca Sacrificial Anode for the Corrosion Protection of Steel Structures (철 구조물의 부식방지를 위한 Mg-Ca 희생양극의 전기화학적 특성과 제조에 관한 연구)

  • Park, Kang-Geun;Kim, Hye-Sung
    • Journal of Korean Association for Spatial Structures
    • /
    • v.6 no.4 s.22
    • /
    • pp.73-80
    • /
    • 2006
  • It is an object of the present paper to investigate a electrochemical properties of Mg-based sacrificial anodes and the effect of calcium added from calcium chloride into magnesium on the melt protection during the melting. Electrochemical data will be correlated with processing control variables, and the microstructural change by the addition of CaCl2. Small addition of calcium into magnesium from CaCl2 imparts beneficial effect in electrochemical properties of Mg alloys, primarily, through microstructural modifications. In addition, the protection effect of the melts surface of Ca with low melting point modification is obtained by adding Ca not more than 0.6%.

  • PDF

An Experimental Study on Distribution of Ultimate Strength of Concrete-Filled Steel Tube Columns according to Concrete Strength and Section Properties Ratio (콘크리트강도 및 단면특성에 따른 콘크리트 충전강관(CFT) 기둥의 극한강도 분포에 관한 실험적 연구)

  • Jang, Gab-Chul;Chang, Kyong-Ho
    • Journal of Korean Association for Spatial Structures
    • /
    • v.8 no.5
    • /
    • pp.59-65
    • /
    • 2008
  • Recently, to improve the load carrying capacity of column structures such as bridge piers, application to concrete-filled steel tube(CFT) type columns are increased more and more. To design the concrete-filled steel tube(CFT) columns in accuracy, influence of material and geometry properties and aspect ratio on ultimate strength of the concrete-filled steel tube column is investigated by experimental researches. In this investigation, the ultimate strength distribution of the concrete-filled steel tube column in accordance with diameter-thickness ratio(D/t) and steel-concrete area ratio(As/Ac) are clarified by the compressive tests. Futhermore, parametric experimental investigation on concrete target strength is performed. It was known from experimental observation that ultimate strength of concrete-filled steel tube column under axial compressive loading more depends on section properties of steel tube rather than concrete strength.

  • PDF

Nonlinear free vibration analysis of moderately thick viscoelastic plates with various geometrical properties

  • Nasrin Jafari;Mojtaba Azhari
    • Steel and Composite Structures
    • /
    • v.48 no.3
    • /
    • pp.293-303
    • /
    • 2023
  • In this paper, geometrically nonlinear free vibration analysis of Mindlin viscoelastic plates with various geometrical and material properties is studied based on the Von-Karman assumptions. A novel solution is proposed in which the nonlinear frequencies of time-dependent plates are predicted according to the nonlinear frequencies of plates not dependent on time. This method greatly reduces the cost of calculations. The viscoelastic properties obey the Boltzmann integral law with constant bulk modulus. The SHPC meshfree method is employed for spatial discretization. The Laplace transformation is used to convert equations from the time domain to the Laplace domain and vice versa. Solving the nonlinear complex eigenvalue problem in the Laplace-Carson domain numerically, the nonlinear frequencies, the nonlinear viscous damping frequencies, and the nonlinear damping ratios are verified and calculated for rectangular, skew, trapezoidal and circular plates with different boundary conditions and different material properties.

Characteristics of the Process of Visual Attention during Spatial Depth Perception (공간의 깊이감 지각과정에 나타난 시각정보획득 특성)

  • Kim, Jong-Ha;Cho, Ji Young
    • Science of Emotion and Sensibility
    • /
    • v.21 no.1
    • /
    • pp.115-128
    • /
    • 2018
  • Understanding the process of spatial perception plays a significant role in the design process as well as in the use of actual spaces. The perception of spatial depth can vary according to the space composition and design even there is no change in the actual size of the space. The properties of 3-dimensional space are its width, height, and depth; however, compared to the perception of spatial width and height, little research and theories exist on spatial depth perception. The reasons may be there less interest lies in the effect of spatial depth perception than that of spaciousness or height of space. This study is an investigation of the process of spatial depth perception using an eye-tracking device with stimuli developed through Computer Graphics. A total of 44 interior design major students participated in the eye tracking experiment; and they looked at three images comprised of an identical room with only changes in the rear wall condition. The results show that a significant difference in the fixation duration per stimulus exists. In addition, a significant difference exists on the fixation duration per stimulus according to the participants' answer of the deepest space. The result of this study can help identify factors for spatial depth perception, validate the assumption on it, and provide knowledge on how to acquire desirable spatial depth by utilizing the research result.

Characteristics of a new cone beam computed tomography

  • Park, Chang-Seo;Kim, Kee-Deog;Park, Hyok;Jeong, Ho-Gul;Lee, Sang-Chul
    • Imaging Science in Dentistry
    • /
    • v.37 no.4
    • /
    • pp.205-209
    • /
    • 2007
  • Purpose: To determine the physical properties of a newly developed cone beam computed tomography (CBCT). Materials and Methods: We measured and compared the imaging properties for the indirect-type flat panel detector (FPD) of a new CBCT and the single detector array (SDA) of conventional helical CT (CHCT). Results: First, the modulation transfer function (MTF) of the CBCT were superior to those of the CHCT. Second, the noise power spectrum (NPS) of the CBCT were worse than those of the CHCT. Third, detective quantum efficiency (DQE) of the indirect-type CBCT were worse than those of the CHCT at lower spatial frequencies, but were better at higher spatial frequencies. Although the comparison of contrast-to-noise ratio (CNR) was estimated in the limited range of tube current, CNR of CBCT were worse than those of CHCT. Conclusion: This study shows that the indirect-type FPD system may be useful as a CBCT detector because of high resolution.

  • PDF

Impact Localization of a Composite Plate Using a Single Transducer and Spatial Focusing Signal Processing Techniques (단일 센서와 공간집속 신호처리 기술을 이용한 복합재 판에서의 충격위치 결정)

  • Cho, Sungjong;Jeong, Hyunjo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.23 no.2
    • /
    • pp.152-159
    • /
    • 2013
  • A structural health monitoring(SHM) technique for locating impact position in a composite plate is presented in this paper. The technique employs a single sensor and spatial focusing properties of time reversal(TR) and inverse filtering(IF). We first examine the focusing effect of back-propagated signal at the impact position and its surroundings through simulation. Impact experiments are then carried out and the localization images are found using the TR and IF signal processing, respectively. Both techniques provide accurate impact location results. Compared to existing techniques for locating impact or acoustic emission source, the proposed methods have the benefits of using a single sensor and not requiring knowledge of material properties and geometry of structures. Furthermore, it does not depend on a particular mode of dispersive Lamb waves that is frequently used in the SHM of plate-like structures.

On Flexibility in Architecture Focused on the Contradiction in Designing Flexible Space and Its Design Proposition

  • Kim, Young-Ju
    • Architectural research
    • /
    • v.15 no.4
    • /
    • pp.191-200
    • /
    • 2013
  • Since Modern Movement flexibility has been one of the most attractive words in architecture. However, "overprovision first, division later" has been the most prevailing design method for spatial flexibility, and many of buildings designed for flexible use are practically quite inflexible due to insufficient building systems or/and irresponsible planning. There have been two dominant strategies to achieve architectural flexibility: multi-functionality and polyvalence. These two approaches, which point contradictory directions, actually reflect the difficulty in providing a proper form of architectural flexibility. Multi-functionality can afford changeable environments with satisfying spatial conditions; however it lacks tolerance to accommodate other uses but intended functions by architects. Meanwhile, flexibility by a polyvalent form relies on the vague anticipation of user's various interpretations. In this study by looking up these two different standpoints and historical precedents flexibility in architecture is carefully scrutinized focused on the contradiction, and as an alternative for architectural flexibility contextual relations is proposed. Unlike both multi-functionality and polyvalence, which produce flexibility by changing its own properties, manipulating contextual relations infuses flexibility into space by changing the properties of a building, not of its individual room. By using this contextual relations method, a community-centered school in Manhattan, NY, which was in danger of being closed because of its academic failure, is represented as a flexible space.

A Dynamic Variable Window-based Topographical Classification Method Using Aerial LiDAR Data (항공 라이다 데이터를 이용한 동적 가변 윈도우 기반 지형 분류 기법)

  • Sung, Chul-Woong;Lee, Sung-Gyu;Park, Chang-Hoo;Lee, Ho-Jun;Kim, Yoo-Sung
    • Spatial Information Research
    • /
    • v.18 no.5
    • /
    • pp.13-26
    • /
    • 2010
  • In this paper, a dynamic variable window-based topographical classification method is proposed which has the changeable classification units depending on topographical properties. In the proposed scheme, to im prove the classification efficiency, the unit of topographical classification can be changeable dynamically according to the topographical properties and repeated patterns. Also, in this paper, the classification efficiency and accuracy of the proposed method are analyzed in order to find an optimal maximum decision window-size through the experiment. According to the experiment results, the proposed dynamic variable window-based topographical classification method maintains similar accuracy but remarkably reduce computing time than that of a fixed window-size based one, respectively.

In-situ monitoring and reliability analysis of an embankment slope with soil variability

  • Bai, Tao;Yang, Han;Chen, Xiaobing;Zhang, Shoucheng;Jin, Yuanshang
    • Geomechanics and Engineering
    • /
    • v.23 no.3
    • /
    • pp.261-273
    • /
    • 2020
  • This paper presents an efficient method utilizing user-defined computer functional codes to determine the reliability of an embankment slope with spatially varying soil properties in real time. The soils' mechanical properties varied with the soil layers that had different degrees of compaction and moisture content levels. The Latin Hypercube Sampling (LHS) for the degree of compaction and Kriging simulation of moisture content variation were adopted and programmed to predict their spatial distributions, respectively, that were subsequently used to characterize the spatial distribution of the soil shear strengths. The shear strength parameters were then integrated into the Geostudio command file to determine the safety factor of the embankment slope. An explicit metamodal for the performance function, using the Kriging method, was established and coded to efficiently compute the failure probability of slope with varying moisture contents. Sensitivity analysis showed that the proposed method significantly reduced the computational time compared to Monte Carlo simulation. About 300 times LHS Geostudio computations were needed to optimize precision and efficiency in determining the failure probability. The results also revealed that an embankment slope is prone to high failure risk if the degree of compaction is low and the moisture content is high.

Developing the Core Modules of for Viz-Platform for Supporting Public Service in the City (도시의 공공서비스 제공을 위한 시각화 플랫폼의 핵심모듈 개발)

  • Kim, Mi-Yun
    • Journal of Korea Multimedia Society
    • /
    • v.18 no.9
    • /
    • pp.1131-1139
    • /
    • 2015
  • The purpose of this research is creating the visualization platform of the user interface to make able to be provide the demanded service while users communication with surrounding space in a smart city environment. This comes from the latest enhanced interface technology and social media, and it uses the shares information to support the proper interface environment according to a life style and spatial properties. "EzCity" which is the user interface platform suggested in this research, can control the enormous amount of public data for the smart city. The core module of user platform is made up with Public data module, Interface module, Visualization module and Service module. The role of this platform is to be provide "Geo-Intelligent Interface Service" for space users to access the data in easier and more practical interface environment. This reinforces the visualization process for data collecting, systematization, visualization and providing service. Also this will be expected to be the base to solve the problem which complexity and rapidly increasing amount of data.