• Title/Summary/Keyword: Span Matrix

Search Result 98, Processing Time 0.019 seconds

A Nonlinear Analysis of Cable Stayed Bridge including Sway Vibrational Effects using Multiple Cable Elements (다수 케이블요소를 사용한 사장교의 횡방향진동을 포함한 비선형 해석)

  • Seong, Ik-Hyun;Yoon, Ki-Yong
    • Journal of Korean Society of Steel Construction
    • /
    • v.12 no.6
    • /
    • pp.661-670
    • /
    • 2000
  • To investigate the characteristics of the dynamic response of long-span cable-stayed bridges due to various dynamic loadings likes moving traffic loads, two different 3-D cable-stayed bridge models are considered in this study. Two models are exactly the same in structural configurations but different in finite element discretization. Modal analysis is conducted using the deformed dead-load tangent stiffness matrix. A new concept was presented by using divided a cable into several elements in order to study the effect of the cable vibration (both in-plane and swinging) on the overall bridge dynamics. Futhermore case of asymmetric traffic loading clustered in one direction are also considered to study the torsional response of the bridge. The result of this study demonstrates the importance of cable vibration on the overall bridge dynamics.

  • PDF

Characteristics of Static Buckling Load of the Hexagonal Spatial Truss Models using Timber (목재를 이용한 육각형 공간 트러스 모델의 정적좌굴하중 특성)

  • Ha, Hyeonju;Shon, Sudeok;Lee, Seungjae
    • Journal of Korean Association for Spatial Structures
    • /
    • v.22 no.3
    • /
    • pp.25-32
    • /
    • 2022
  • In this paper, the instability of the domed spatial truss structure using wood and the characteristics of the buckling critical load were studied. Hexagonal space truss was adopted as the model to be analyzed, and two boundary conditions were considered. In the first case, the deformation of the inclined member is only considered, and in the second case, the deformation of the horizontal member is also considered. The materials of the model adopted in this paper are steel and timbers, and the considered timbers are spruce, pine, and larch. Here, the inelastic properties of the material are not considered. The instability of the target structure was observed through non-linear incremental analysis, and the buckling critical load was calculated through the singularities and eigenvalues of the tangential stiffness matrix at each incremental step. From the analysis results, in the example of the boundary condition considering only the inclined member, the critical buckling load was lower when using timber than when using steel, and the critical buckling load was determined according to the modulus of elasticity of timber. In the case of boundary conditions considering the effect of the horizontal member, using a mixture of steel and timber case had a lower buckling critical load than the steel case. But, the result showed that it was more effective in structural stability than only timber was used.

SUMRAY: R and Python Codes for Calculating Cancer Risk Due to Radiation Exposure of a Population

  • Michiya Sasaki;Kyoji Furukawa;Daiki Satoh;Kazumasa Shimada;Shin'ichi Kudo;Shunji Takagi;Shogo Takahara;Michiaki Kai
    • Journal of Radiation Protection and Research
    • /
    • v.48 no.2
    • /
    • pp.90-99
    • /
    • 2023
  • Background: Quantitative risk assessments should be accompanied by uncertainty analyses of the risk models employed in the calculations. In this study, we aim to develop a computational code named SUMRAY for use in cancer risk projections from radiation exposure taking into account uncertainties. We also aim to make SUMRAY publicly available as a resource for further improvement of risk projection. Materials and Methods: SUMRAY has two versions of code written in R and Python. The risk models used in SUMRAY for all-solid-cancer mortality and incidence were those published in the Life Span Study of a cohort of the atomic bomb survivors in Hiroshima and Nagasaki. The confidence intervals associated with the evaluated risks were derived by propagating the statistical uncertainties in the risk model parameter estimates by the Monte Carlo method. Results and Discussion: SUMRAY was used to calculate the lifetime or time-integrated attributable risks of cancer under an exposure scenario (baseline rates, dose[s], age[s] at exposure, age at the end of follow-up, sex) specified by the user. The results were compared with those calculated using another well-known web-based tool, Radiation Risk Assessment Tool (RadRAT; National Institutes of Health), and showed a reasonable agreement within the estimated confidential interval. Compared with RadRAT, SUMRAY can be used for a wide range of applications, as it allows the risk projection with arbitrarily specified risk models and/or population reference data. Conclusion: The reliabilities of SUMRAY with the present risk-model parameters and their variance-covariance matrices were verified by comparing them with those of the other codes. The SUMRAY code is distributed to the public as an open-source code under the Massachusetts Institute of Technology license.

Effects of specimens dimension on the flexural properties and testing reliability of dental composite resin (치과용 복합레진의 굽힘 특성과 시험 신뢰도에 미치는 시편 크기의 영향)

  • Im, Yong-Woon;Hwang, Seong-sig;Kim, Sa-hak;Lee, Hae-Hyoung
    • Korean Journal of Dental Materials
    • /
    • v.44 no.3
    • /
    • pp.273-280
    • /
    • 2017
  • The aim of the present study was to investigate the effects of specimen dimension on the flexural properties and testing reliability of dental composite resin. The composite resin was prepared experimentally by mixing a resin matrix with silanated micrometer glass filler at 50 vol%. Flexural specimens with various dimension in specimen's width were fabricated by light curing using a split metal mold; $25{\times}2{\times}2mm$, $25{\times}2{\times}4mm$, $25{\times}2{\times}6mm$ in length ${\times}$ height ${\times}$ width. The flexural strength and modulus were determined according to ISO 4049 test protocol at a span length of 20 mm (normal-flexural strength; NFS). Another flexural test was conducted using mini-sized specimens ($12{\times}2{\times}2mm$, $12{\times}2{\times}4mm$, $12{\times}2{\times}6mm$) from the broken specimens at a span length of 10 mm (mini-flexural strength; MFS). Data were analyzed with ANOVA and Duncan's post-hoc test and the test reliability was evaluated by Weibull analysis. Results showed that there are generally no significant difference in flexural strength with the increase in the specimen width in NFS and MFS tests. However, the test reliability of flexural strength based on Weibull analysis was largely changed with the variables in the dimension of width and span length. The flexural modulus of NFS was increased as the dimension of specimens width increased while there was no trend in flexural modulus of MFS test. Overall results recommend that the evaluation of flexural properties and the reliability of dental composite resins should be performed with more than one test method.

Development of Korean Neurobehavioral Test Battery -Assessment of the Validity of Traditional and Computerized Neurobehavioral Tests- (한국형 신경행동검사 배터리의 개발 -면접과 컴퓨터 신경행동검사의 타당성 평가-)

  • Chung, Jong-Hak;Kim, Chang-Yoon;SaKong, Joon;Jeon, Man-Joong;Park, Hong-Chin
    • Journal of Preventive Medicine and Public Health
    • /
    • v.31 no.4 s.63
    • /
    • pp.692-707
    • /
    • 1998
  • Aim. A neurobehavioral test for workers exposed to organic solvents in the workplace can be affected by many factors : age, education, motivation, ethnicity, etc. To apply more suitable neurobehavioral test for Korean workers, we evaluated the validity of several items of computerized and traditional neurobehavioral tests. Methods. We have applied eleven tests : four items of computerized neurobehavioral test(Swedish Performance Evaluation System) including Addition, Symbol-Digit, Dig-it Span, and Finger tapping speed, and seven items of traditional neurobehavioral test consisting of Addition, Digit-Symbol, Digit Span, Benton visual retention test, Pursuit aiming, Pegboard, and Tapping. These tests were performed on 96 workers exposed to solvents, and 100 reference workers. The concurrent and construct validities were evaluated by group difference, correlation with age, educational level, hippuric acid level, neurotoxic symptom, current exposure level, multitrait-multimethod matrix, fator analysis, and discriminant analysis. Results. Statistically significant differences were observed between the workers exposed to solvents and referents in computerized Symbol-Digit, Finger tapping speed, traditional Digit-Symbol and Pegboard. The computerized Symbol-Digit, traditional Digit-Symbol, Addition, Benton visual retention test, and Pegboard were found to be related to the age. The performance of computerized Symbol-Digit, Addition, and traditional Digit-Symbol were found to be related to the educational level significantly. The computerized Symbol-Digit, Finger tapping speed, and traditional Digit-Symbol were found to be related to hippuric acid, and neurotoxic symptom. The discriminability of Finger tapping speed, and Pegboard was better than the other tests. In discriminant analysis, the model with two variables, the computerized Symbol-Digit and Pegboard, classified almost 70 percent of the workers correctly. Conclusions. These results suggest that the computerized Symbol-Digit, Finger tapping speed, and Pegboard are more satisfactory for our purpose, and the Addition, Tapping, Benton visual retention test, and Pursuit aiming are less valid than other items. These may allow the reasonable selection of core neurobehavioral tests for workers exposed to solvents in Korea.

  • PDF

Wine quality grading by near infrared spectroscopy.

  • Dambergs, Robert G.;Kambouris, Ambrosias;Schumacher, Nathan;Francis, I. Leigh;Esler, Michael B.;Gishen, Mark
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.1253-1253
    • /
    • 2001
  • The ability to accurately assess wine quality is important during the wine making process, particularly when allocating batches of wines to styles determined by consumer requirements. Grape payments are often determined by the quality category of the wine that is produced from them. Wine quality, in terms of sensory characteristics, is normally a subjective measure, performed by experienced winemakers, wine competition judges or winetasting panellists. By nature, such assessments can be biased by individual preferences and may be subject to day-to-day variation. Taste and aroma compounds are often present in concentrations below the detection limit of near infrared (NIR) spectroscopy but the more abundant organic compounds offer potential for objective quality grading by this technique. Samples were drawn from one of Australia's major wine shows and from BRL Hardy's post-vintage wine quality allocation tastings. The samples were scanned in transmission mode with a FOSS NIR Systems 6500, over the wavelength range 400-2500 ㎚. Data analysis was performed with the Vision chemometrics package. With samples from the allocation tastings, the best correlations between NIR spectra and tasting data were obtained with dry red wines. These calibrations used loadings in the wavelengths related to anthocyanins, ethanol and possibly tannins. Anthocyanins are a group of compounds responsible for colour in red wines - restricting the wavelengths to those relating to anthocyanins produced calibrations of similar accuracy to those using the full wavelength range. This was particularly marked with Merlot, a variety that tends to have relatively lower anthocyanin levels than Cabernet Sauvignon and Shiraz. For dry white wines, calibrations appeared to be more dependent on ethanol characteristics of the spectrum, implying that quality correlated with fruit maturity. The correlations between NIR spectra and sensory data obtained using the wine show samples were less significant in general. This may be related to the fact that within most classes in the show, the samples may span vintages, glowing areas and winemaking styles, even though they may be made from only one grape variety. For dry red wines, the best calibrations were obtained with a class of Pinot Noir - a variety that tends to be produced in limited areas in Australia and would represent the least matrix variation. Good correlations were obtained with a tawny port class - these wines are sweet, fortified wines, that are aged for long periods in wooden barrels. During the ageing process Maillard browning compounds are formed and the water is lost through the barrels in preference to ethanol, producing “concentrated” darkly coloured wines with high alcohol content. These calibrations indicated heaviest loadings in the water regions of the spectrum, suggesting that “concentration” of the wines was important, whilst the visible and alcohol regions of the spectrum also featured as important factors. NIR calibrations based on sensory scores will always be difficult to obtain due to variation between individual winetasters. Nevertheless, these results warrant further investigation and may provide valuable Insight into the main parameters affecting wine quality.

  • PDF

Development of Probiotic Microcapsules for the Preservation of Cell Viability (생균활성 보존을 위한 유산균 미세캡슐 개발)

  • Lee, Kang-Whi;Jang, Keum-Il;Lee, Yoon-Bok;Sohn, Heon-Soo;Kim, Kwang-Yup
    • Korean Journal of Food Science and Technology
    • /
    • v.39 no.1
    • /
    • pp.66-70
    • /
    • 2007
  • Lactobacillus fermentum YL-3 was encapsulated to increase acid tolerance and its total viability. After micro-encapsulation of L. fermentum YL-3 cells with sodium alginate and soybean oil, the morphology of the microcapsule was observed using confocal laser scanning microscopy (CLSM) after staining with pyronin Y and fluorescein isothiocyanate. The sizes of the microcapsules were 120-126 ${\mu}m$, 444-486 ${\mu}m$ and 401-463 ${\mu}m$ when manufactured at pH 2, 3 and 4, respectively. The microcapsule could hold live cells of L. fermentum YL-3 up to $1.2{\times}10^{7}$, $8.1{\times}10^{7}$ and $1.1{\times}10^{8}$ CFU/mL at pH 2, 3 and 4, respectively. The acid tolerance and preservative ability of L. fermentum YL-3 in microcapsule and macrocapsule at $4^{\circ}C$ and $25^{\circ}C$ were tested. L. fermentum YL-3 cells were evenly located in the alginate capsule matrix structure and the firmness of microcapsule was highest at pH 2. Micro-encapsulation showed the most effective acid tolerance at pH 2.0 and preservation of viability at $4^{\circ}C$. However, at $25^{\circ}C$, the macrocapsules showed more effective cell protection than the microcapsules. The application range for microcapsules could be wider than for macrocapsules in the food industry.

Target Proteins Involved in Aging Mechanism as an Aging Molecular Marker (노화 분자마커로서 노화기전에 관여하는 타켓 단백질)

  • Kim, Moon-Moo
    • Journal of Life Science
    • /
    • v.26 no.8
    • /
    • pp.983-989
    • /
    • 2016
  • All cells composing of our body undergo their destiny such as proliferation, differentiation, necrosis, apoptosis and senescence depending on their circumstance with time. The errors occurring in these processes develop several aberrations in phenotypes including cancer, inflammation, aging and diseases. New strategy and approach are required to screen anti-aging compounds derived from natural products. Therefore, here we explain the target proteins to play a key role in aging mechanism. In the first place, matrix metalloproteinases (MMPs) are involved in metastasis, chronic inflammation and skin aging as an aging marker. In particular, histone deacetylases (HDACs) give a great attention to aging researchers who try to extend the life span of animal model. In addition, we describe the signaling pathway related to senescence which p53, IGF-1 and SIRT1 play an important role in. Furthermore, autophagy is involved in the signaling pathway associated with aging. Several new compounds modulating the signaling pathway of senescence are introduced in this review. Here, we try to provide a new insight in the molecular basis for the aging mechanism and development of aging marker. In addition, the compounds introduced here could be available for pharmaceutical applications for the prevention and the treatment of diseases related to aging.