• Title/Summary/Keyword: Space time modulation

Search Result 212, Processing Time 0.026 seconds

Performance Analysis of MIMO-OFDMA System Applying Dynamic Resource Allocation (동적 자원 할당 기법을 적용한 MIMO-OFDMA 시스템 성능 분석)

  • Lee, Yun-Ho;Kim, Kyung-Seok
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.6
    • /
    • pp.669-676
    • /
    • 2008
  • The adaptive resource optimization problem in multi-input multi-output orthogonal frequency division multiple access (MIMO-OFDMA) systems is addressed. This paper, adaptive modulation and coding(AMC) and power control algorithms is proposed with SFC(Space-Frequency Coding), which aims to maximize the system capacity based on the CQI(Channel Quality Information). Firstly, power level is decided to each sub-channels with received feedback signal to noise ratio(SNR). In the second step, sub-carriers are allocated according to modulation type. Simulation results show that the proposed algorithm achieves a better performance than conventional algorithm in terms of capacity.

Ground Experiment of Spacecraft Attitude Control Using Hardware Testbed

  • Oh, Choong-Suk;Bang, Hyo-Choong
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.4 no.1
    • /
    • pp.75-87
    • /
    • 2003
  • The primary objective of this study is to demonstrate ground-based experiment for the attitude control of spacecraft. A two-axis rotational simulator with a flexible ann is constructed with on-off air thrusters as actuators. The simulator is also equipped with payload pointing capability by simultaneous thruster and DC servo motor actuation. The azimuth angle is controlled by on-off thruster command while the payload elevation angle is controlled by a servo-motor. A thruster modulation technique PWM(Pulse Width Modulation) employing a time-optimal switching function plus integral error control is proposed. An optical camera is used for the purpose of pointing as well as on-board rate sensor calibration. Attitude control performance based upon the new closed-loop control law is demonstrated by ground experiment. The modified switching function turns out to be effective with improved pointing performance under external disturbance. The rate sensor calibration technique by Kalman Filter algorithm led to reduction of attitude error caused by the bias in the rate sensor output.

A Modulation Transfer Function Compensation for the Geostationary Ocean Color Imager (GOCI) Based on the Wiener Filter

  • Oh, Eunsong;Ahn, Ki-Beom;Cho, Seongick;Ryu, Joo-Hyung
    • Journal of Astronomy and Space Sciences
    • /
    • v.30 no.4
    • /
    • pp.321-326
    • /
    • 2013
  • The modulation transfer function (MTF) is a widely used indicator in assessments of remote-sensing image quality. This MTF method is also used to restore information to a standard value to compensate for image degradation caused by atmospheric or satellite jitter effects. In this study, we evaluated MTF values as an image quality indicator for the Geostationary Ocean Color Imager (GOCI). GOCI was launched in 2010 to monitor the ocean and coastal areas of the Korean peninsula. We evaluated in-orbit MTF value based on the GOCI image having a 500-m spatial resolution in the first time. The pulse method was selected to estimate a point spread function (PSF) with an optimal natural target such as a Seamangeum Seawall. Finally, image restoration was performed with a Wiener filter (WF) to calculate the PSF value required for the optimal regularization parameter. After application of the WF to the target image, MTF value is improved 35.06%, and the compensated image shows more sharpness comparing with the original image.

Analysis and Compensation Control of Dead-Time Effect on Space Vector PWM

  • Shi, Jie;Li, Shihua
    • Journal of Power Electronics
    • /
    • v.15 no.2
    • /
    • pp.431-442
    • /
    • 2015
  • Dead-time element must be set into space vector pulsed width modulation signals to avoid short circuits of the inverter. However, the dead-time element distorts the output voltage vector, which deteriorates the performance of electrical machine drive system. In this paper, dead-time effect and its compensation control strategy are analyzed. Based on the analysis, the voltage distortion caused by dead-time is regarded as two disturbances imposed on dq axes in the rotor reference frame, which degenerates the current tracking performance. To inhibit the adverse effect caused by the dead-time, a control scheme using two linear extended state observers is proposed. This method provides a strong ability to suppress dead-time effects. Simulations and experiments are conducted on a permanent magnet synchronous motor drive system to demonstrate the effectiveness of the proposed method.

Unitary precoding space time block coding with limited feedback (폐-루프 다중안테나시스템에서 제한된 피드백을 이용한 시공간블록부호기술의 적용)

  • Kim, Jeong-Mi;Oh, Dong-Jin;Kim, Cheol-Sung
    • Proceedings of the IEEK Conference
    • /
    • 2005.11a
    • /
    • pp.85-88
    • /
    • 2005
  • Space-time code is a good solution to get transmit diversity. During the last years a number of space-time block codes have been proposed for use in multiple transmit antenna systems. This code, however, was presented only for the special case of the certain numbers of transmit antennas and the certain modulation schemes. and designed under the assumption that the transmitter has no knowledge about the channel. In this work, on the other hand, we consider the case when the transmitter has partial, but not perfect knowledge about the channel. This system can have full diversity for arbitrary number of the transmit antennas with a little bits of feedback.

  • PDF

Generalized Principal Ratio Combining of Space-Time Trellis Coded OFDM over Multi-Path Fading Channels (다중 경로 채널에서 공간-시간 트렐리스 부호화된 OFDM의 일반화된 준최적 검파)

  • Kim, Young-Ju
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.19 no.3
    • /
    • pp.352-357
    • /
    • 2008
  • We present a space-time trellis coded OFDM system in slow fading channels. Generalized principal ratio combining (GPRC) is also analyzed theoretically in frequency domain. The analysis shows that the decoding metric of GPRC includes the metrics of maximum likelihood(ML) and PRC. The computer simulations with M-PSK modulation are obtained in frequency flat and frequency selective fading channels. The decoding complexity and simulation running times are also evaluated among the decoding schemes.

The Algorithms for Controlling AC Output Voltage of Z-Source Inverter Using Modified SVPWM

  • Tran Quang-Vinh;Chun Tae-Won;Son Jang-Kyung;Hee Lee-Hong;Ahn Jung-Ryol
    • Proceedings of the KIPE Conference
    • /
    • 2004.11a
    • /
    • pp.64-69
    • /
    • 2004
  • This paper deals with an algorithm for controlling ac output voltage of Z-source inverter using Modified SVPWM (abbreviated as MSVPWM). Unlike the conventional space vector pulse width modulation, MSVPWM has one extra shoot-through zero time $T_{sh}$. During shoot-through zero time, both switches in a leg are conducted simultaneously in order to boost inverter output voltage to any desirable value regardless the line voltage. The algorithm to control linearly the capacitor voltage is suggested to improve the performance of Z-source inverter system. The performance of Z-source inverter using above algorithms is demonstrated in simulation results using PSIM. Index terms-Z-source inverter (ZSI), shoot-through time, three-phase carrier-based PWM, space vector PWM (SVPWM), modified space vector PWM (MSVPWM).

  • PDF

Dead Time Compensation Algorithm for the 3-Phase Inverter using SVPWM (SVPWM 방식의 3상 인버터에 대한 간단한 데드타임 보상 알고리즘)

  • Kim, Hong-Min;Choo, Young-Bae;Lee, Dong-Hee
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.16 no.6
    • /
    • pp.610-617
    • /
    • 2011
  • This paper proposes a novel and direct dead-time compensation method of the 3-phase inverter using space vector pulse width modulation(SVPWM) topology. The proposed dead-time compensation method directly compensates the dead-time to the turn-on time of the effective voltage vector according to the current direction of the medium voltage reference. Each phase voltages are determined by the switching times of the effective voltage vectors, and the practical switching times have loss according to the current direction by the dead-time effect in the 3-phase inverter. The proposed method adds the dead-time to the switching time of the effective voltage vector according to the current direction, so it does not require complex d-q transform and controller to compensate the voltage error. The proposed dead-time compensation scheme is verified by the computer simulation and experiments of 3-phase R-L load.

Power-efficiency Analysis of the MIMO-VLC System considering Dimming Control (조광제어를 고려한 MIMO-VLC 시스템의 전력 효율 분석)

  • Kim, Yong-Won;Lee, Byung-Jin;Lee, Byung-Hoon;Lee, Min-Jung;Kim, Kyung-Seok
    • The Journal of the Institute of Internet, Broadcasting and Communication
    • /
    • v.18 no.6
    • /
    • pp.169-180
    • /
    • 2018
  • White light-emitting diodes (LEDs) are more economical than fluorescent lights, and provide high brightness, a high lifetime expectancy, and greater durability. As LEDs are closely connected with people's daily lives, dimming control of LED is an important component in providing energy savings and improving quality of life. In visible light communications systems using these LEDs, multiple input multiple output (MIMO) technology has attracted a lot of attention, in that it can attain the channel capacity in proportion to the number of antennas. This paper analyzes the power performance of three kinds of modulation in visible light communications (VLC) systems applied space-time block code (STBC) techniques. The modulation schemes are return-to-zero on-off keying (RZ-OOK), variable pulse position modulation (VPPM), and overlapping pulse position modulation (OPPM), and dimming control was applied. The power requirements and power consumption were used as metrics to compare the power efficiency in $2{\times}2$ STBC-VLC environments under the three kinds of modulation. We confirm that dimming control affects the communications performance of each modulation scheme. VPPM showed greater consumption among the three modulations, and OPPM showed energy savings comparable to VPPM.

Pulse Code Signal Recognition using Integra-Normalizer (인테그라-노말라이저를 이용한 펄스코드 신호인식)

  • Kim, Seong-Su
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.49 no.8
    • /
    • pp.491-494
    • /
    • 2000
  • A scheme is proposed for measuring similarities between the binary pulse signals in the pulse-code modulation using the Integra-Normalizer. The Integra-Normalizer provides a better interpretation of the relationship between the pulse signals by removing redundant codes, which maps all possible observed signals to one of the codes to be received with relative similarities between each pair of compared signals. The proposed method provides better error tolerance than L2 metric, such as Hamming distance, since the distances between pulse signals are measured not useful for the time-delay detection in the pulse-code modulation.

  • PDF