• Title/Summary/Keyword: Space placement

Search Result 279, Processing Time 0.027 seconds

Guidelines Development of Living and Social Environmental Aspects for the Planning of Back-to-Farm Community Village (귀촌형 공동체마을 조성을 위한 생활환경과 사회환경 측면의 가이드라인 개발)

  • Park, Kyoung-Ok;Lee, Sang-Un;Jung, Ji-In
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.20 no.1
    • /
    • pp.1-10
    • /
    • 2018
  • In order to give back-to-farm residents the stable settlement environment in the rural area, the 'community village' is desirable as the village type and its village planning guideline should be supported as well. The purpose of this study was to develop a guideline for the planning of back-to-farm community village in the living and social environmental aspects, based on the comprehensive comparative analysis about items that field survey and literature suggested. The guideline for the living environment was developed for 6 items; village structure(adequate size, lot, outer space for household), village landscape(allocation, space composition), road system and transportation(parking lot in village, placement of bus stops, village trail, public transportation, road and pedestrian system), common living facilities and common space(number, size, location & placement, plan type, planning type of common facilities), transfer space, individual housing(type, size, planning type). The guideline for the social environment was developed for 3 items; village making and establishment(resident participation type, resident participation tool, residents' construction participation) and resident education in the course of planning, resident participation(gathering resident opinion, decision making, composition of construction committee, community newsletter).

Computational study of road tunnel exposure to severe wind conditions

  • Muhic, Simon;Mazej, Mitja
    • Wind and Structures
    • /
    • v.19 no.2
    • /
    • pp.185-197
    • /
    • 2014
  • Ventilation and fire safety design in road tunnels are one of the most complex issues that need to be carefully considered and analysed in the designing stage of any potential upgrade of ventilation and other fire safety systems in tunnels. Placement road tunnels space has an important influence on fire safety, especially when considering the effect of adverse wind conditions that significantly influence ventilation characteristics. The appropriate analysis of fire and smoke control is almost impossible without the use of modern simulation tools (e.g., CFD) due to a large number of influential parameters and consequently extensive data. The impact of the strong wind is briefly presented in this paper in the case of a longitudinally ventilated road tunnel Kastelec, which is exposed to various severe wind conditions that significantly influence its fire safety. The possibility of using CFD simulations in the analysis of the tunnel placement in space terms negative effect of wind influence on the tunnel ventilation is clearly indicated.

A Study on the Design Elements and Features of Environment-Friendly Architecture (친환경건축(親環境建築)의 디자인구성요소(構成要素)와 계획특성(計劃特性)에 관한 연구(硏究))

  • Lee, Sang-Ok;John, Che-Hui
    • KIEAE Journal
    • /
    • v.2 no.3
    • /
    • pp.47-54
    • /
    • 2002
  • As the problems of environment have been increasing, the architecture is exploring ways toward development of a idea for future generation. The purpose of this study is design element of environment-friendly architecture, and a general concept and mark of environment-friendly architecture are considered. And then, the design element is analyzed to come true the mark by considering the internal and external examples. The related elements on design of environment-friendly architecture are proposed by considering estimation items: The items are divided into six branches that is placement strategy, outside space furtherance, form of building, room environment furtherance, supply processing system, and preservation administration. Through this process, this study is proposed applicable solution of a concrete plan.

Inverse Perturbation Method and Sensor Location for Structural Damage Detection (구조물의 손상탐지를 위한 역섭동법과 센서위치의 선정)

  • Park, Yun Cheol;Choe, Yeong Jae;Jo, Jin Yeon;Kim, Gi Uk
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.31 no.3
    • /
    • pp.31-38
    • /
    • 2003
  • In the present work, a nonlinear inverse perturbation method which has been used in the structural optimization, is adopted so as to identify the structural damages. Unlike the structural optimization, a larger number of constrained equations than the number of unknown parameters are often required detect structural damage. Therefore, nonlinear least squares method is utilized to solve the problem. Because only a limited number of sensors are available I real situation of damage detection, the determination of sensor location becomes one of the most important issues. Hence, this work concentrates on the issue of sensor placement in the framework of nonlinear inverse perturbation method, and the performances of various methodologies concerning to sensor placement are compared with each other. The comparisons show tat the successive elimination method gets good performance for sensor placement. From the several numerical studies, it is confirmed that the inverse perturbation method, combined with the successive elimination method, is very promising in structural damage detection.

Epidural Emphysema Associated with Subcutaneous Emphysema after Chest Tube Placement: A Case Report (흉관 삽입 후 발생한 피하 기종을 동반한 척추 경막외 기종: 증례 보고)

  • Rho, Ji-Young;Yoo, Seung-Min;Cho, Young-Ah;Lee, Sang-Min
    • Tuberculosis and Respiratory Diseases
    • /
    • v.69 no.5
    • /
    • pp.389-391
    • /
    • 2010
  • Spinal epidural emphysema is rare and has been described secondary to following medical intervention, such as lumbar puncture and epidural analgesia, pneumothorax or pneumomediastinum, degenerative disk disease, epidural abscess, and trauma. Rarely, it occurs after chest tube placement. We report a case of spinal epidural emphysema incidentally noted on HRCT after chest tube placement.

Sensor placement strategy for high quality sensing in machine health monitoring

  • Gao, Robert X.;Wang, Changting;Sheng, Shuangwen
    • Smart Structures and Systems
    • /
    • v.1 no.2
    • /
    • pp.121-140
    • /
    • 2005
  • This paper presents a systematic investigation of the effect of sensor location on the data quality and subsequently, on the effectiveness of machine health monitoring. Based on an analysis of the signal propagation process from the defect location to the sensor, numerical simulations using finite element modeling were conducted on a bearing test bed to determine the signal strength at several representative sensor locations. The results showed that placing sensors closely to the machine component being monitored is critical to achieving high signal-to-noise ratio, thus improving the data quality. Using millimeter-sized piezoceramic plates, the obtained results were evaluated experimentally. A comparison with a set of commercial vibration sensors verified the developed structural dynamics-based sensor placement strategy. It further demonstrated that the proposed shock wave-based sensing technique provided an effective alternative to vibration measurement, while requiring less space for sensor installation.

Process Development for Optimizing Sensor Placement Using 3D Information by LiDAR (LiDAR자료의 3차원 정보를 이용한 최적 Sensor 위치 선정방법론 개발)

  • Yu, Han-Seo;Lee, Woo-Kyun;Choi, Sung-Ho;Kwak, Han-Bin;Kwak, Doo-Ahn
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.18 no.2
    • /
    • pp.3-12
    • /
    • 2010
  • In previous studies, the digital measurement systems and analysis algorithms were developed by using the related techniques, such as the aerial photograph detection and high resolution satellite image process. However, these studies were limited in 2-dimensional geo-processing. Therefore, it is necessary to apply the 3-dimensional spatial information and coordinate system for higher accuracy in recognizing and locating of geo-features. The objective of this study was to develop a stochastic algorithm for the optimal sensor placement using the 3-dimensional spatial analysis method. The 3-dimensional information of the LiDAR was applied in the sensor field algorithm based on 2- and/or 3-dimensional gridded points. This study was conducted with three case studies using the optimal sensor placement algorithms; the first case was based on 2-dimensional space without obstacles(2D-non obstacles), the second case was based on 2-dimensional space with obstacles(2D-obstacles), and lastly, the third case was based on 3-dimensional space with obstacles(3D-obstacles). Finally, this study suggested the methodology for the optimal sensor placement - especially, for ground-settled sensors - using the LiDAR data, and it showed the possibility of algorithm application in the information collection using sensors.

The Aspiration of Injected Air via an Epidural Catheter as an Indicator for Appropriate Placement of the Catheter in the Epidural Space (경막외 카테터의 적합한 위치지표로서의 주입공기의 흡인)

  • Cheong, Soon Ho;Park, Dae Sik;Moon, Sung Ho;Cho, Kwang Rae;Lee, Sang Eun;Kim, Young Hwan;Lim, Se Hun;Lee, Jeong Han;Lee, Kun Moo;Choe, Young Kyun;Kim, Young Jae;Shin, Chee Mahn
    • The Korean Journal of Pain
    • /
    • v.22 no.2
    • /
    • pp.124-129
    • /
    • 2009
  • Background: The "gold standard" for proper epidural catheter positioning is a clinical response, as assessed by a pinprick test. Yet it may take time or it may be difficult to perform this test after epidural catheter placement in sedated or uncooperative patients or during general anesthesia. We assessed the usefulness of aspirating injected air via an epidural catheter as an indicator of correct epidural catheter placement. Methods: We surveyed 200 patients who underwent surgery under general or epidural anesthesia. A Tuohy needle was inserted into the epidural space with using the hanging drop technique. After placement of the epidural catheter, 3 ml of air was injected via the catheter, and then the volume of aspirated air was measured. Results: The mean volume of aspirated air was $2.3{\pm}0.7ml$ (75% of the injected air volume) and this ranged from 0 to 3 ml. Conclusions: Aspiration of injected air is a simple alternative method for identifying the appropriate placement of epidural catheters in the epidural space.

A Study on Typology of Maru's Placement in Korean Traditional Single Houses of Four Kan in Chonnam Province (전라남도 4칸 홑집의 마루배치에 관한 조사연구)

  • Chang, Dong-Kuk;Chung, Seong-Kyoon;Shin, Woong-Ju;Eun, Chul-Young;Kim, Soo-In;Park, Kang-Chul
    • Journal of architectural history
    • /
    • v.16 no.4
    • /
    • pp.23-36
    • /
    • 2007
  • Many researches on the typology of 'Maru' (Wooden deck) in Korean traditional houses have mainly focused on the high-class houses in the central region of Korea. They were mainly concerned on defining Maru's typology by social status of the owner, based on the researches regarding its physical and spatial properties. Maru in the high-class traditional houses has been served as an essential architectural feature showing the social status of owners as well as adapting in the region of humid and hot summer. This research investigated the typology of Maru's placement in traditional single houses of four Kan in Chonnam province, which shows many differences in its placement according to the regions. Research results show that the typology of Maru's placement and openness is different with the location of houses within the region. This difference affects on the circulation of movement, which eventually affects on the pattern of space use. The difference is also very likely to be affected by the natural environment of geography and climate of the region.

  • PDF

Modeling and Performance Evaluation of AP Deployment Schemes for Indoor Location-Awareness (실내 환경에서 위치 인식율을 고려한 AP 배치 기법의 모델링 및 성능 평가)

  • Kim, Taehoon;Tak, Sungwoo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.17 no.4
    • /
    • pp.847-856
    • /
    • 2013
  • This paper presents an AP placement technique considering indoor location-awareness and examines its performance. The proposed AP placement technique is addressed from three performance metrics: location-awareness and AP-based wireless network performance as well as its cost. The proposed AP placement technique consists of meta-heuristic algorithms that yield a near optimal AP configuration for given performance metrics, and deterministic algorithms that improve the fast convergence of the near optimal AP configuration. The performance of the AP placement technique presented in this paper is measured under the environments simulating indoor space, and numerical results obtained by experimental evaluation yield the fast convergence of a near-optimal solution to a given performance metric.