Browse > Article
http://dx.doi.org/10.3344/kjp.2009.22.2.124

The Aspiration of Injected Air via an Epidural Catheter as an Indicator for Appropriate Placement of the Catheter in the Epidural Space  

Cheong, Soon Ho (Department of Anesthesiology and Pain Medicine, Pusan Paik Hospital, College of Medicine, Inje University)
Park, Dae Sik (Gupo Sungsim Hospital)
Moon, Sung Ho (Department of Anesthesiology and Pain Medicine, Pusan Paik Hospital, College of Medicine, Inje University)
Cho, Kwang Rae (Department of Anesthesiology and Pain Medicine, Pusan Paik Hospital, College of Medicine, Inje University)
Lee, Sang Eun (Department of Anesthesiology and Pain Medicine, Pusan Paik Hospital, College of Medicine, Inje University)
Kim, Young Hwan (Department of Anesthesiology and Pain Medicine, Pusan Paik Hospital, College of Medicine, Inje University)
Lim, Se Hun (Department of Anesthesiology and Pain Medicine, Pusan Paik Hospital, College of Medicine, Inje University)
Lee, Jeong Han (Department of Anesthesiology and Pain Medicine, Pusan Paik Hospital, College of Medicine, Inje University)
Lee, Kun Moo (Department of Anesthesiology and Pain Medicine, Pusan Paik Hospital, College of Medicine, Inje University)
Choe, Young Kyun (Department of Anesthesiology and Pain Medicine, Pusan Paik Hospital, College of Medicine, Inje University)
Kim, Young Jae (Department of Anesthesiology and Pain Medicine, Pusan Paik Hospital, College of Medicine, Inje University)
Shin, Chee Mahn (Department of Anesthesiology and Pain Medicine, Pusan Paik Hospital, College of Medicine, Inje University)
Publication Information
The Korean Journal of Pain / v.22, no.2, 2009 , pp. 124-129 More about this Journal
Abstract
Background: The "gold standard" for proper epidural catheter positioning is a clinical response, as assessed by a pinprick test. Yet it may take time or it may be difficult to perform this test after epidural catheter placement in sedated or uncooperative patients or during general anesthesia. We assessed the usefulness of aspirating injected air via an epidural catheter as an indicator of correct epidural catheter placement. Methods: We surveyed 200 patients who underwent surgery under general or epidural anesthesia. A Tuohy needle was inserted into the epidural space with using the hanging drop technique. After placement of the epidural catheter, 3 ml of air was injected via the catheter, and then the volume of aspirated air was measured. Results: The mean volume of aspirated air was $2.3{\pm}0.7ml$ (75% of the injected air volume) and this ranged from 0 to 3 ml. Conclusions: Aspiration of injected air is a simple alternative method for identifying the appropriate placement of epidural catheters in the epidural space.
Keywords
air aspiration; epidural anesthesia; epidural catheter;
Citations & Related Records
연도 인용수 순위
  • Reference
1 Tsui BC, Gupta S, Finucane B: Confirmation of epidural catheter placement using nerve stimulation. Can J Anaesth 1998; 45: 640-4   DOI   ScienceOn
2 Rapp HJ, Folger A, Grau T: Ultrasound-guided epidural catheter insertion in children. Anesth Analg 2005; 101: 333-9   DOI   ScienceOn
3 Tanaka M, Nishikawa T: T-wave amplitude as an indicator for detecting intravascular injection of epinephrine test dose in awake and anesthetized elderly patients. Anesth Analg 2001; 93: 1332-7   DOI   ScienceOn
4 Liu SS, Carpenter RL: Hemodynamic responses to intravascular injection of epinephrine-containing epidural test doses in adults during general anesthesia. Anesthesiology 1996; 84: 81-7   DOI   ScienceOn
5 Willschke H, Marhofer P, Böosenberg A, Johnston S, Wanzel O, Sitzwohl C, et al: Epidural catheter placement in children: comparing a novel approach using ultrasound guidance and a standard loss-of-resistance technique. Br J Anaesth 2006; 97: 200-7   DOI   ScienceOn
6 Miller RD: Miller's anesthesia. 6th ed. Philadelphia, Churchill Livingstone. 2004, p 2738
7 Ghia JN, Arora SK, Castillo M, Mukherji SK: Confirmation of location of epidural catheters by epidural pressure waveform and computed tomography cathetergram. Reg Anesth Pain Med 2001; 26: 337-41   PUBMED   ScienceOn
8 Sala-Blanch X, Martinez-Palli G, Agusti-Lasus M, Nalda- Felipe MA: Misplacement of multihole epidural catheters--a report of two cases. Anaesthesia 1996; 51: 386-8   DOI   ScienceOn
9 Tanaka M, Nishikawa T: Aging reduces the efficacy of the simulated epidural test dose in anesthetized adults. Anesth Analg 2000; 91: 657-61   ScienceOn
10 Tsui BC, Sze CK: An in vitro comparison of the electrical conducting properties of multiport versus single-port epidural catheters for the epidural stimulation test. Anesth Analg 2005; 101: 1528-30   DOI   ScienceOn
11 Tanaka M, Yamamoto S, Ashimura H, Iwai M, Matsumiya N: Efficacy of an epidural test dose in adult patients anesthetized with isoflurane: lidocaine containing 15 micrograms epinephrine reliably increases arterial blood pressure, but not heart rate. Anesth Analg 1995; 80: 310-4   DOI
12 Takahashi S, Tanaka M: Reduced efficacy of simulated epidural test doses in sevoflurane-anesthetized adults. Can J Anaesth 1999; 46: 433-8   DOI   ScienceOn
13 Salevsky FC, Whalley DG, Kalant D, Crawhall J: Epidural epinephrine and the systemic circulation during peripheral vascular surgery. Can J Anaesth 1990; 37: 160-5   DOI   ScienceOn
14 Sethna NF, Berde CB: Venous air embolism during identification of the epidural space in children, Anesth Analg 1993; 76: 925-7   ScienceOn
15 Gaiser RR: The epidural test dose in obstetric anesthesia: it is not obsolete. J Clin Anesth 2003; 15: 474-7   DOI   PUBMED   ScienceOn
16 Beck H, Brassow F, Doehn M, Bause H, Dziadzka A, Schulte am Esch J: Epidural catheters of the multi-orifice type: dangers and complications. Acta Anaesthesiol Scand 1986; 30: 549-55   DOI   ScienceOn
17 Hogan Q: Epidural catheter tip position and distribution of injectate evaluated by computed tomography. Anesthesiology 1999; 90: 964-70   DOI   PUBMED   ScienceOn
18 Leighton BL, Katsiris SE, Halpern SH, Wilson DB, Kronberg JE: Multiport epidural catheters: can orifice location be tested? Anesthesiology 2000; 92: 1840-2   DOI   ScienceOn
19 Saberski LR, Kondamuri S, Osinubi OY: Identification of the epidural space: is loss of resistance to air a safe technique? A review of the complications related to the use of air. Reg Anesth 1997; 22: 3-15   DOI   PUBMED   ScienceOn