• Title/Summary/Keyword: Space nuclear application

Search Result 49, Processing Time 0.02 seconds

A Study on the Radiative Heat Transfer Characteristics in the Fluidized Particles Layer (유동입자층에서의 복사열전달 특성에 관한 연구)

  • 김금무;김용모;김경근
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.18 no.4
    • /
    • pp.33-42
    • /
    • 1994
  • The radiative heat transfer analysis in the fluidized particles layer has important application in many technological areas such as combustion chambers at high pressure and temperature, plasma generators for nuclear fusion, MHD generator using pulverized coal and the liquid droplet radiator used to reject wasted heat from a power plant operating in space. To accurately model the radiation properties of the fluidized particles layer, it is necessary to know the radiation interchange factors of particles in each layer. But the solutions are usually not possible for the equations of radiative heat transfer because it has an inherent difficulty in treating the governing intergo- differential equations, which are derived from the remote effects of radiative heat transfer. In this study, the analysis uses the Monte Carlo simulation method with optical depth model to calculate the radiation interchange factors of particles in each layer with wall and with each other.

  • PDF

The Development of the Solar Tracking System with High Accuracy by using LabVIEW (LabVIEW를 활용한 고정밀도 태양추적장치 개발)

  • Oh, Seung-Jin;Cho, Yil-Sik;Lee, Yoon-Joon;Chun, Won-Gee
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.04a
    • /
    • pp.31-36
    • /
    • 2009
  • There have been many solar tracking systems developed for the high accuracy in solar tracking. One of the key components of any motion control system is software. LabVIEW offers an ideal combination of flexibility, ease-of-use and well-integration with other I/O pieces for developing solar tracking system. Real-time solar positions which vary with GPS's data are used simultaneously to control the solar tracker by a chain of operating modes between the open and closed loops. This paper introduces a step by step procedure for the fabrication and performance assessment of a precision solar tracking system. The system developed in this study consists of motion controllers, motor drives, step-motors, feedback devices and application. CRD sensors are applied for the solar tracking system which play a primary role in poor conditions for tracking due to a gear backlash and a strong wind. Mini-dish was used as a concentrator for collecting sun light. The solar position data, in terms of azimuth and elevation, sunrise and sunset times was compared with those of KASI(Korea Astronomy & Space Science Institute). The results presented in this paper demonstrate the accuracy of the present system in solar tracking and utilization.

  • PDF

The luminescence properties of Eu3+ or Tb 3+ doped Lu2Gd1Ga2Al3O12 phosphors for X-ray imaging

  • M.J. Oh;Sudipta Saha;H.J. Kim
    • Nuclear Engineering and Technology
    • /
    • v.55 no.12
    • /
    • pp.4642-4646
    • /
    • 2023
  • The Tb3+ or Eu3+-doped Lu2Gd1Ga2Al3O12 phosphor were fabricated by funace at 1500 ℃ for 12 h using a solid state reaction. The XRD (X-ray diffraction_Panalytical X'Pert Pro) and FE-SEM (field emission scanning electron microscope) are measured to confirm the crystalline structure and surface morphology of the phosphor. The Tb3+-doped Lu2Gd1Ga2Al3O12 phosphor emits the lights in 470~650 nm wavelength range due to transitions from 5D4 to 7Fj. Therefore, it shows the green region in the CIE chromaticity diagram under both UV and X-rays excitations. The Eu3+-doped Lu2Gd1Ga2Al3O12 phosphor emits the lights in 550~750 nm wavelength range because of 5Di to 7Fj. The emission is confirmed to be in the red region using the CIE chromaticity diagram. The Tb3+ or Eu3+-doped Lu2Gd1Ga2Al3O12 phosphor shows the characteristic f-f transition with a long decay time, which is about several milliseconds. They have the high efficiency of light emission for X-ray because of their high effective Z number (Zeff = 58.5) and density. Therefore, they are very much promising phosphors for X-ray imaging application in medical fields.

A Study on 2010 Beijing Convention for Antiterrorism of International Aviation - Compared Beijing Convention(2010) with Montreal Protocol - (국제항공테러방지 북경협약(2010)에 관한 연구 - 몬트리올협약과의 비교를 중심으로 -)

  • Hwang, Ho-Won
    • The Korean Journal of Air & Space Law and Policy
    • /
    • v.25 no.2
    • /
    • pp.79-112
    • /
    • 2010
  • The Beijing Convention of 2010 taken together effectively establishes a new broader and stronger civil aviation security framework. This adoption would significantly advance cooperation in prevent of the full range of unlawful acting relation to civil aviation and the prosecution and punishment of offenders. First, the Beijing Convention of 2010 will require parties to criminalize a number of new and emerging threats to the safety of civil aviation, including using aircraft as a weapon and organizing, directing and financing acts of terrorism. These new treaties reflect the international community's shared effort to prevent acts of terrorism against civil aviation and to prosecute and punish those who would commit them. Second, this convention will also require States to criminalize the transport of biological, chemical, nuclear weapons and related material. These provisions reflect the nexus between non-proliferation and terrorism and ensure that the international community will act to combat both. Third, this Convention shall not apply to aircraft used in military, customs or police services. As a substitute, International Humanitarian Law will be applied in a case. Moreover, the National Jurisdiction and the application of the law will be extended farther. The treaty promotes cooperation between States while emphasizing the human rights and fair treatment of terrorist suspects.

  • PDF

Current Status and Future Perspective of PET (PET 이용 현황 및 전망)

  • Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.36 no.1
    • /
    • pp.1-7
    • /
    • 2002
  • Positron Emission Tomography (PET) is a nuclear medicine imaging modality that consists of systemic administration to a subject of a radiopharmaceutical labeled with a positron-emitting radionuclide. Following administration, its distribution in the organ or structure under study can be assessed as a function of time and space by (1) defecting the annihilation radiation resulting from the interaction of the positrons with matter, and (2) reconstructing the distribution of the radioactivity from a series of that used in computed tomography (CT). The nuclides most generally exhibit chemical properties that render them particularly desirable in physiological studies. The radionuclides most widely used in PET are F-18, C-11, O-15 and N-13. Regarding to the number of the current PET Centers worldwide (based on ICP data), more than 300 PET Centers were in operation in 2000. The use of PET technology grew rapidly compared to that in 1992 and 1996, particularly in the USA, which demonstrates a three-fold rise in PET installations. In 2001, 194 PET Centers were operating in the USA. In 1994, two clinical and research-oriented PET Centers at Seoul National University Hospital and Samsung Medical Center, was established as the first dedicated PET and Cyclotron machines in Korea, followed by two more PET facilities at the Korea Cancer Center Hospital, Ajou Medical Center, Yonsei University Medical Center, National Cancer Center and established their PET Center. Catholic Medical School and Pusan National University Hospital have finalized a plan to install PET machine in 2002, which results in total of nine PET Centers in Korea. Considering annual trends of PET application in four major PET centers in Korea in Asan Medical Center recent six years (from 1995 to 2000), a total of 11,564 patients have been studied every year and the number of PET studies has shown steep growth year upon year. We had 1,020 PET patients in 1995. This number increased to 1,196, 1,756, 2,379, 3,015 and 4,414 in 1996,1997,1998,1999 and 2000, respectively. The application in cardiac disorders is minimal, and among various neuropsychiatric diseases, patients with epilepsy or dementia can benefit from PET studios. Recently, we investigated brain mapping and neuroreceptor works. PET is not a key application for evaluation of the cardiac patients in Korea because of the relatively low incidence of cardiac disease and less costly procedures such as SPECT can now be performed. The changes in the application of PET studios indicate that, initially, brain PET occupied almost 60% in 1995, followed by a gradual decrease in brain application. However, overall PET use in the diagnosis and management of patients with cancer was up to 63% in 2000. The current medicare coverage policy in the USA is very important because reimbursement policy is critical for the promotion of PET. In May 1995, the Health Care Financing Administration (HCFA) began covering the PET perfusion study using Rubidium-82, evaluation of a solitary pulmonary nodule and pathologically proven non-small cell lung cancer. As of July 1999, Medicare's coverage policy expanded to include additional indications: evaluation of recurrent colorectal cancer with a rising CEA level, staging of lymphoma and detection of recurrent or metastatic melanoma. In December of 2001, National Coverage decided to expand Medicare reimbursement for broad use in 6 cancers: lung, colorecctal, lymphoma, melanoma, head and neck, and esophageal cancers; for determining revascularization in heart diseases; and for identifying epilepsy patients. In addition, PET coverage is expected to further expand to diseases affecting women, such as breast, ovarian, uterine and vaginal cancers as well as diseases like prostate cancer and Alzheimer's disease.

Field Application of Ultrasonic Inspection System for Stay Welds at Steam Generator of KSNP (한국표준형 원전 증기발생기 Stay 용접부 자동검사시스템 및 현장 검증)

  • Lim, Sa Hoe;Park, Chi Seung;Park, Chul Hoon;Joo, Keum Chong;Noh, Hee Chung;Yoon, Kwang Sik
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.6 no.1
    • /
    • pp.37-42
    • /
    • 2010
  • The stay cylinder weld at the steam generator of Korean Standard Nuclear Power Plants is safety class I component and is subjected to be inspected by the volumetric examination such as ultrasonic method. As accessibility of this area is limited due to the narrow space and high radiation, the existing manual inspection method involves various difficulties. Moreover operators may be exposed to internal contamination by contaminated dust during the surface buffing process to improve the inspection reliability of this area. Recently the new automatic inspection system for stay cylinder welds has been developed. The inspection system basically consists of a driving assembly, data acquisition device and signal processing units. The driving assembly is classified by 1) the scanner for inspecting and buffing the weld, 2) pillars for guiding the scanner and 3) the base frame for loading and supporting pillars. The scanner has 4 sensor modules to inspect in 4 refracted angles and 4 incident directions. These components can be inserted into the skirt of the stay cylinder through the manway hole and assembled easily by one-touch in the skirt. Data acquisition device and signal processing units developed in previous works are also newly upgraded for better processing of data analysis and evaluation. The system has been successfully demonstrated not only in the mock-up but also in the field. In this paper, newly developed inspection system for the stay cylinder weld of the steam generator is introduced and their field applications are discussed.

  • PDF

The Construction Work Completion of the Fuel Test Loop (핵연료 노내조사시험설비 설치공사 완료)

  • Park, Kook-Nam;Lee, Chung-Young;Chi, Dae-Young;Park, Su-Ki;Shim, Bong-Sik;Ahn, Sung-Ho;Kim, Hark-Rho;Lee, Jong-Min
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.291-295
    • /
    • 2007
  • FTL(Fuel Test Loop) is a facility that confirms performance of nuclear fuel at a similar irradiation condition with that of nuclear power plant. FTL consists of In-Pile Test Section (IPS) and Out-Pile System (OPS). FTL construction work began on August, 2006 and ended on March, 2007. During Construction, ensuring the worker's safety was the top priority and installation of the FTL without hampering the integrity of the HANARO was the next one. Task Force Team was organized to do a construction systematically and the communication between members of the task force team was done through the CoP(community of Practice) notice board provided by the Institute. The installation works were done successfully overcoming the difficulties such as on the limited space, on the radiation hazard inside the reactor pool, and finally on the shortening of the shut down period of the HANARO. Without a sweet of the workers of the participating company of HEC(Hyundae Engineering Co, Ltd), HDEC(HyunDai Engineering & Construction Co. Ltd), equipment manufacturer, and the task force team, it is not possible to install the FTL facility within the planned shutdown period. The Commissioning of the FTL is on due to check the function and the performance of the equipment and the overall system as well. The FTL shall start operation with high burn up test fuels in early 2008 if the commissioning and licensing progress on schedule.

  • PDF

The Effects of Hangryunhaedocktang on Allergic Contact Dermatitis Based on the Morphological Changes in Epidemal Damage in Mice (황연해독탕(黃連解毒湯)이 알러지성 접촉피부염에 미치는 영향 -알러지성 접촉피부염 유발로 손상된 생쥐 상피세포의 완화를 중심으로)

  • Kang, Yoon-Ho;Kim, Jin-Taek;Kim, Sung-A
    • The Journal of Internal Korean Medicine
    • /
    • v.25 no.3
    • /
    • pp.508-517
    • /
    • 2004
  • This study was performed to investigate the effectiveness of Hangryunhaedocktang (HHT) on epidermal damages induced by allergic contact dermatitis (ACD). The sensitization were caused by one application of $25{\mu}l$ of 5% 2,4-dinitroch1orobenzene (DNCB) onto a back-lumbar skin of BALB/c mice. 2 weeks later, ACD was elicitated with $4{\mu}l$ of 2.5% DNCB and then mice were given HHT extract in doses of 3.3ml/kg/day, for 72 hours. The ACD induced epidermal damages in HHT treated ACD mice was more mitigated than non-treated ACD elicited mice. The features related with epidermal damage such as epidermal hyperplasia, infiltration of inflammatory cells, increase of nuclear shrinkages and vacuolation, and enlargement of intercellular space softened. And the distribution of soybean agglutinin (SBA) positive reaction in stratum spinosum (SS) and stratum basale (SB) were similarly maintained in a normal configuration. The numerical decrease of BrdU, TUNEL, and Fas positive cells observed were prominent in SB. Results suggest a benefit role for HHT in mitigating epidermal damages in mice with allergic contact dermatitis.

  • PDF

Strain Improvement Based on Ion Beam-Induced Mutagenesis (이온빔을 이용한 미생물의 균주 개량)

  • Jeong, Hae-Young;Kim, Kye-Ryung
    • Microbiology and Biotechnology Letters
    • /
    • v.38 no.3
    • /
    • pp.235-243
    • /
    • 2010
  • For decades, traditional mutation breeding technologies using spontaneous mutation, chemicals, or conventional radiation sources have contributed greatly to the improvement of crops and microorganisms of agricultural and industrial importance. However, new mutagens that can generate more diverse mutation spectra with minimal damage to the original organism are always in need. In this regard, ion beam irradiation, including proton-, helium-, and heavier-charged particle irradiation, is considered to be superior to traditional radiation mutagenesis. In particular, it has been suggested that ion beams predominantly produce strand breaks that often lead to mutations, which is not a situation frequently observed in mutagenesis induced by gamma-ray exposure. In this review, we briefly describe the general principles and history of particle accelerators, and then introduce their successful application in ion beam technology for the improvement of crops and microbes. In particular, a 100-MeV proton beam accelerator currently under construction by the Proton Engineering Frontier Project (PEFP) is discussed. The PEFP accelerator will hopefully prompt the utilization of ion beam technology for strain improvement, as well as for use in nuclear physics, medical science, biology, space technology, radiation technology and basic sciences.

Clinical Observation of Liver Scintigram (간(肝) Scintigram의 임상적(臨床的) 고찰(考察))

  • Moon, Sung-Soo;Oh, Kyoung-Sik;Kim, Yul-Za;Kim, Yong-Cheol;Lee, Chong-Suk;Lee, Hak-Choong
    • The Korean Journal of Nuclear Medicine
    • /
    • v.14 no.2
    • /
    • pp.19-27
    • /
    • 1980
  • Although primary application of radioisotope scanning technics to the liver has been of use in the detection of the intra-hepatic space occupying lesion from the normal functioning liver parenchyme, there has been on increasing awareness of its use in evalution of Liver function. In this study, the diseases of the liver were classified into group A,B,C and D by the liver scanning findings, conventional liver function tests and clinical findings. Following were the results: 1. The colloidal radiogold liver scan appeared normal in the group A, also the albumin in serum, alkaline phosphatase activity and prothrombin time were within normal levels in this group. 2. In the group B, there were acute hepatitis 24(48%), chronic hepatitis 5(10%), toxic hepatitis 3(6%), subacute hepatic necrosis 3(6%), typhoid liver 4(8%), hepatic tuberculosis 2(4%), diabetes mellitus 3(6%) and others 3(6%). In this group, SGOT and SGPT were increased predominantly as compared with group A, and the liver scan showed small amount of mottling of activity and faintly visualized spleen. 3. In the group C, there were postnecrotic liver cirrhosis 30(60%), Laennec cirrhosis 10(20%), cardiac cirrhosis 1(2%), cholangiocarcinoma 1(2%), chronic active hepatitis 6(12%), hepatic milliary tuberculosis 1(2%) and gall bladder cancer 1(2%). In this group, the albumin in serum and prothrombin time were lowered significantly and the liver scan showed severe mottling of activity with extra-hepatic uptake in the spleen and bone marrow along the vertebral column. 4. In the group D, there were primary hepatoma 26(52%), hepatoma with liver cirrhosis 7(14%), metastatic liver cancer 5(10%), liver abscess 10(20%), multiple liver cyst 1(2%) and cystic duct adenoma 1(2%), In this group, the alkaline phosphatase activity was elevated with single or multiple intrahepatic space occupying lesion in the radiogold colloid liver scan.

  • PDF