• Title/Summary/Keyword: Space efficiency

Search Result 2,681, Processing Time 0.029 seconds

Evaluation of Creative Space Efficiency in China' Provinces Based on AHP Method

  • Hu, Shan-Shan;Kim, Hyung-Ho
    • International journal of advanced smart convergence
    • /
    • v.9 no.4
    • /
    • pp.52-61
    • /
    • 2020
  • The AHP method was used in 30 provinces of China to construct the index system of creative space efficiency evaluation and determine the weight of each index. The fuzzy comprehensive evaluation method was further used to score the indexes at all levels, and then the total efficiency score was sorted. The purpose of this study is to adjust the regional layout of creative space reasonably and implement financial policies accurately through the evaluation of the efficiency of creative space. The results is ranking top in weight of several indicators, which include the number of incubated Startups, the number of innovation and entrepreneurship mentors, the survival rate of incubator, the innovative training activities, etc. It was also found that Beijing, Shanghai, Jiangsu, Guangdong and Zhejiang ranked first in the score of creative space efficiency. This study is meaningful in that it was In order to effectively solve the problem of the imbalance of the creative space efficiency in China's province, by coordinating the regional pattern, establishing a sound service system and improving the efficiency evaluation system.

Library Space Efficiency Improvement Through Closed Access System -Focused on Academic Libraries- (공간효율 개선을 위한 폐가식 도서관 운용 -지역 대학도서관 시설을 중심으로-)

  • Ahn, Joon Suk
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.18 no.4
    • /
    • pp.17-24
    • /
    • 2016
  • Since the users have direct access to search and browse freely, the open access system has been employed to all the usual modern libraries. However, library space shortage problem created by the continuously increasing printed materials caused the degradation of usability and quality of the library space. Open Access system is superior in user convenience but is inferior in space efficiency. Keeping the open access system is considered as one of the reasons of the space shortage problem. Even though the closed access system does not provide free access or easy browsing for the uses, it's space efficiency is much higher than the open access system. The closed access system should be employed as a plan to relieve space shortage problem. Since the closed access system does not allow the public direct access to books, it is very economical. It also provides much better space efficiency with higher book shelving density. In this article, closed access library system models and their characteristics are examined as the reduction plans for the library space shortage problems.

A Case Study of Combining NDC Blasting Method and Wide Space Blasting Method to Increase Blast Efficiency (NDC 및 Wide Space 혼합공법을 통한 발파효율 개선 사례연구)

  • No, Sang-Lim;Noh, Seung-Hwan;Lee, Sang-Pil;Lee, Hoon-Yeon;Lee, Tai-Ro
    • Tunnel and Underground Space
    • /
    • v.16 no.5 s.64
    • /
    • pp.387-393
    • /
    • 2006
  • This paper introduces the combination of two blasting methods applied to reduce blast-vibration and increase blast efficiency. NDC (New Deck Charge) blasting method using air deck effect with separation tube made of paper was effective to reduce blast-vibration, while blast efficiency was decreased a little in the bottom of a blasthole. Wide Space blasting method has an advantage to control the fragmentation and to increase blast efficiency over conventional blasting methods. In this study new blasting method combining NDC blasting method and Wide Space blasting method was applied to the field, it was confirmed to reduce blast-vibration and increase blast efficiency. It is expected to make useful blasting method to cover the public complaints and to shorten construction time by accumulating blasting data using new method with various conditions.

Layout design optimization of pipe system in ship engine room for space efficiency

  • Lee, Dong-Myung;Kim, Soo-Young;Moon, Byung-Young;Kang, Gyung-Ju
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.37 no.7
    • /
    • pp.784-791
    • /
    • 2013
  • Recent advanced IT made layout design fast and accurate by using algorithms. Layout design should be determined by considering the position of equipment with satisfying various space constraints and its component works with optimum performance. Especially, engine room layout design is performed with mother ship data, theoretical optimal solution, design requirements and several design constraints in initial design stage. Piping design is affected by position of equipment seriously. Piping design depends on experience of designer. And also piping designer should consider correlation of equipment and efficiency of space. In this study, space evaluation method has been used to evaluate efficiency of space. And also this study suggested object function for optimal piping route, Average Reservation Index(ARI), Estimated Piping Productivity(EPP) and with modified space evaluation method. In this study, optimum pipe routing system has been developed to reflect automated piping route with space efficiency and experience of piping designer. Engine room is applied to the design of the piping in order to confirm validity of the developed system.

Analysis of Effects of Space Charge in Removal efficiency of Pollutant using Dielectric Barrier Discharges (유전체장벽방전효과를 이용한 공해물질 제거 효율에 미치는 공간전하의 영향 분석)

  • Nam, S.H.;Jeon, S.I.;Lee, D.Y.;Lee, J.H.;Han, M.K.
    • Proceedings of the KIEE Conference
    • /
    • 1998.07d
    • /
    • pp.1441-1443
    • /
    • 1998
  • In this work, the effects of space charge was analyzed in removal efficiency of pollutant using dielectric barrier discharges. In order to investigate effects of space charge, two dielectrics(XLPE and TR-XLPE) was chosen which are different in space charge distribution. The simultaneously measurement of space charge and discharge current was carried out in XLPE and TR-XLPE with air gap by Pulsed-Electro-Acoustic Method in ac. Also, the removal efficiency is measured by classical ozone generator(von Siemens 1875). From the experimental results, we knew that the space charge distribution affects the discharge patterns. The more space charge is in surface, the quickly discharge initiates and the magnitude of discharge is increased when polarity changes. And these affect the removal efficiency of pollutant.

  • PDF

Space Efficiency Improvement for Open Access Library -Focused on Book-storage Space of Academic Libraries in Province Area- (개가식 도서관의 공간효율 제고 방안 -지역 대학도서관 서고 공간을 중심으로-)

  • Ahn, Joon Suk
    • Journal of the Korean Institute of Rural Architecture
    • /
    • v.17 no.4
    • /
    • pp.67-74
    • /
    • 2015
  • Due to an inability to accommodate for the rapidly increasing number of printed materials, Korean academic libraries are facing serious space shortage problems. Very few academic institutions have the funds to expand existing libraries or construct new facilities in order to accommodate the influx of printed materials. Despite not having the luxury to create new space, many establishments continue to implement the open access system. Seeing that such a system is only user friendly when used in a spacious facility, the maintenance of the open access system is unreasonable. Only few libraries consider the space efficient closed access system which helps to resolve storage space shortage. In the current state of the problem, improving the efficiency to which books are stored in existing storage areas within a library facility is the only appropriate solution. Enacting methods to improve physical space utilization within a fixed volume library facility will undoubtedly diminish the space shortage issue at hand. In this article, several space efficiency improvement approaches are discussed. Methods of book storage plan re-layout (floor, plan, ceiling, height, bookshelf design), book arrangement possibilities, and the reduction of the physical volume of reserved materials are each examined.

A Study on the Evaluation of the Cognition of the Circulation Efficiency in Geriatric Hospital (노인요양병원 진료부의 경로인지 효율성 평가에 관한 연구)

  • Bae, Sun-mi;Kim, Suk-Tae
    • Korean Institute of Interior Design Journal
    • /
    • v.25 no.6
    • /
    • pp.40-51
    • /
    • 2016
  • The aim of this study is to quantitatively deduce the circulation efficiency and space arrangements of the outpatient department in geriatric hospitals in terms of spatial structure and to find a methodology that could promote the improvement of accessibility and spatial cognition while using the facilities. All space units of the selected twelve geriatric hospitals were located on the first floor. The study adopted the psychological distance concept of space syntax to the unitized spaces, and presented a set of indices, such as TD, PN, RF, PNT and TRF. These indices were calculated according to the standard clinical use procedures. The study evaluated the effectiveness of circulation. The analysis of circulation was based on the four major geriatric illnesses that were selected in this study. The study established the standard clinical use procedure with consideration of the medical treatment, examinations and space units of outpatient departments. The results are as follows: 1) Based on the statistical data, four major geriatric illnesses are examined, and space requirement and standard procedures are established. Development indicators are applied in order to quantitatively deduce the efficiency of spatial cognition. 2) The percentage of the risk of cognitive decline(TRF) has an inversely proportional correlation to the circulation efficiency(PNT) at a certain point. TRF is more influenced by the clinical use procedure than the scale. 3) The arrangement of the waiting space and types of corridor greatly affect the percentage of the risk of cognitive decline. 4) Vulnerable facilities are selected on the basis of the evaluation, and two alternatives that could promote the circulation efficiency are presented. The result of the reanalysis showed that cognitive efficiency had much improved compared to the existing facilities.

Advanced Silicon Solar Cell Structures for Space Applications

  • Lee, S.H.;Kim, D.S.
    • Solar Energy
    • /
    • v.17 no.2
    • /
    • pp.23-33
    • /
    • 1997
  • This paper reviews the advanced solar cell structures used in space. These are the structures which incorporate the back surface field and reflectors with very shallow and lightly doped emitters. Their use in space has shown that the thinner cells are more resistive to radiation damage than the thicker ones. It has been found that the charged particles affect both the surface and bulk of the cells used in space. This causes degradation in the output power, which in effect, can be explained by the degrading diffusion length of the cells. The PERL cells showed higher BOL(beginning of life) efficiency and almost the same EOL(end of life) efficiency as structures with wrap-around contact configuration fabricated on 10 ${\Omega}cm$ resistivity substrates. This observation lead to a conclusion that, the space cells do not necessarily need to have very high BOL efficiency except in specific missions which require such.

  • PDF

Performance Variation of the Air Curtain for Various Discharge Angles in Feating Space (난방공간에서 에어커튼의 토출각도 변화에 따른 성능 변화)

  • Sung, Sun-Kyung
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.22 no.2
    • /
    • pp.57-63
    • /
    • 2010
  • Air curtains are widely used for gates of shopping mall, warehouse, cold stores and refrigerated display cabinets. The purpose of the air curtain is to reduce the infiltration of outdoor air and heat loss from the air conditioning space to ambient air. The discharge angle of air curtain is very important as the sealing efficiency is affected by it. This paper presents a performance of single jet air curtain in heating space when the discharge angle of nozzle changes. A numerical simulation is used to study the influence of various parameters on the efficiency of the downward-blowing air curtain device which is installed inside of the wall above the door. The performance of the air curtain is evaluated by sealing efficiency which provides the assessment of the energy savings. A condition of discharge angle that has the highest sealing efficiency is proposed.

Efficiency estimation of ASTE receiver optics using measured beam patterns from KASI band 7+8 feed horn

  • Lee, Bangwon;Lee, Jung-won;Kang, Hyunwoo;Je, Do-Heung
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.43 no.2
    • /
    • pp.44.2-44.2
    • /
    • 2018
  • We conducted efficiency calculation in a prototype receiver optics for ASTE 10 meter telescope using the measured beam patterns of the band7+8 feed horn. Beam measurements results are summarized and estimated aperture efficiencies over band7+8 frequency range are presented.

  • PDF