• Title/Summary/Keyword: Space Rate

Search Result 3,337, Processing Time 0.032 seconds

The Analysis of the Topside Additional Layer of Martian Ionosphere Using MARSIS/Mars Express Data

  • Kim, Eojin;Seo, Haingja;Kim, Joo Hyeon;Lee, Joo Hee;Kim, Yong Ha;Choi, Gi-Hyuk;Sim, Eun-Sup
    • Journal of Astronomy and Space Sciences
    • /
    • v.29 no.4
    • /
    • pp.337-342
    • /
    • 2012
  • In this study, the transient second or third layer on the topside of the Martian ionosphere were investigated with the most recently released Mars advanced radar for subsurface and ionospheric sounding/Mars Express data obtained from January 2010 to September 2011 to study the correlation between these topside additional layers and surface magnetic fields, solar zenith angle and solar activities. When examining the zones where the topside layer appeared, the occurrence rate of the topside layer was low at the areas with a strong Martian crustal magnetic field as observed by the Mars global surveyor. The occurrence rate of additional layers on the Martian topside ionosphere decreases as the solar zenith angle increases. However, these layers appeared significantly near the terminator of which solar zenith angle is $90^{\circ}$. In comparison between F10.7 which is the index of solar activities and the occurrence rate of the topside layer by date, its occurrence rate was higher in 2011 than in 2010 with less solar activities. The result of this study will contribute to better understanding of the environments in the topside of the ionosphere through the correlation between the various conditions regarding the Martian ionosphere and the transient layer.

Study of Hydraulic Characteristics with the Shape of the Intake of an Underground Inflow Facility using Hydraulic Experiments (수리실험을 이용한 지하유입시설 유입구 형상에 따른 수리학적 특성 분석)

  • Seong, Ho Je;Park, In Hwan;Rhee, Dong Sop
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.4
    • /
    • pp.119-126
    • /
    • 2018
  • In recent years, as flood damage caused by heavy rains increased, the great-depth tunnel using urban underground space is emerging as a countermeasure of urban inundation. The great-depth tunnel is used to reduce urban inundation by using the underground space. The drainage efficiency of great-depth tunnel depends on the intake design, which leads to increase discharge into the underground space. The spiral intake and the tangential intake are commonly used for the inlet facility. The spiral intake creates a vortex flow along the drop shaft and reduces an energy of the flow by the wall friction. In the tangential intake, flow simply falls down into the drop shaft, and the design is simple to construct compared to the spiral intake. In the case of the spiral intake, the water level at the drop shaft entrance is risen due to the chocking induced by the flowrate increase. The drainage efficiency of the tangential intake decreases because the flow is not sufficiently accelerated under low flow conditions. Therefore, to compensate disadvantages of the previously suggested intake design, the multi-stage intake was developed which can stably withdraw water even under a low flow rate below the design flow rate. The hydraulic characteristics in the multi-stage intake were analyzed by changing the flow rate to compare the drainage performance according to the intake design. From the measurements, the drainage efficiency was improved in both the low and high flow rate conditions when the multi-stage inlet was employed.

A Smooth Estimation of Failure Rate Function (고장률 함수의 평활추정)

  • 나명환;이현우;김재주
    • Journal of Korean Society for Quality Management
    • /
    • v.25 no.3
    • /
    • pp.51-61
    • /
    • 1997
  • We introduce a method of estimating an unknown failure rate function based on sample data. We estimate failure rate function by a function s from a space of cubic splines constrained to be linear (or constant) in tails using maximum likelihood estimation. The number of knots are determined by Bayesian Information Criterion(BIC). Examples using simulated data are used to illustrate the performance of this method.

  • PDF

The Study for the KOMPSAT-3 Image Data Compression

  • Lee S.G.;Lee S.T.
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.298-300
    • /
    • 2005
  • Satellite payload on-board date compression unit are use for saving date storage space and reducing time to transmit payload data to the ground station. The KOMPSAT-3 payload will generate higher data rate than KOMPSAT-2 due to its better ground sample distance capacity. High input data rate and limited output transmission data rate might lead excessive compression and degraded image quality. This paper presents a trade-off study about data storage capacity and compression parameters for estimated KOMPSAT-3 system.

  • PDF

Flammability Limits Variation of Opposed Flow Diffusion Flames for Different Channel Gap (채널 간격에 따른 대향류 확산화염의 가연 영역의 변화)

  • Lee, Min Jung;Kim, Nam Il
    • 한국연소학회:학술대회논문집
    • /
    • 2012.11a
    • /
    • pp.323-324
    • /
    • 2012
  • Flammability limits of opposed flow diffusion flame in a narrow channel was investigated experimentally and theoretically. There were three different extinction modes corresponding to high strain rate (HSR), low strain rate (LSR) and dilution ratio (DR) limits. To investigate these limits, a theoretical study was followed by focusing on flow and heat transfer characteristics. Consequently, a dead space concept that has been used for premixed flames was important to reveal the heat loss mechanism in a narrow channel especially for LSR conditions even in the case of diffusion flames.

  • PDF

Variation of abrasive feed rate with abrasive injection waterjet system process parameters (연마재 투입형 워터젯 시스템의 공정 변수에 따른 연마재 투입량 변화)

  • Joo, Gun-Wook;Oh, Tae-Min;Kim, Hak-Sung;Cho, Gye-Chun
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.17 no.2
    • /
    • pp.141-151
    • /
    • 2015
  • A new rock excavation method using an abrasive injection waterjet system has been developed to enhance the efficiency and reduce the vibration of tunnel excavation. The abrasive feed rate is an important factor for the cutting performance and the economical efficiency of waterjet-based excavation. In this study, various experiments were performed to explore the effects of major process parameters for both the abrasive feed rate and the suction pressure occurring inside the mixing chamber when the abrasives are inhaled. Experimental results reveal that the abrasive feed rate is affected by geometry parameters (abrasive pipe height, length, and tortuosity), abrasive parameters (abrasive particle size), and jet energy parameters (water pressure and water flow rate). In addition, the relation between the cutting performance and the abrasive feed rate was discussed on the basis of the results of an experimental study. The cutting performance can be maximized when the abrasive feed rate is controlled appropriately via careful management of major process parameters.

ON THE BACKGROUND-SUBTRACTED INTENSITY (백그라운드 제거후 신호의 세기에 대하여)

  • Seon, Kwang-Il
    • Publications of The Korean Astronomical Society
    • /
    • v.20 no.1 s.24
    • /
    • pp.109-116
    • /
    • 2005
  • When we measure a source signal in the presence of a background rate that has been independently measured, the usual approach is to obtain an estimate of the background rate by observing an empty part of the sky, and an estimate of the source signal plus background rate by observing the region where a source signal is expected. The source signal rate is then estimated by subtracting the background rate from the source signal plus background rate. However, when the rates or their observation times are small, this procedure can lead to negative estimates of the source signal rate, even when it should produce a positive value. By applying the Bayesian approach, we solve the problem and prove that the most probable value of source signal rate is zero when the observed total count is smaller than the expected background counts. It is also shown that the results from the conventional method is consistent with the most probable value obtained from the Bayesian approach when the source signal is large or the observation time is long enough.

An Experimental Study on the Ventilation velocity of the Variation of Burning rate in Tunnel Fires - Heptane pool fire case (터널 화재시 배연속도가 연소율변화에 미치는 실험적 연구 - Heptane 풀화재 경우)

  • Ryou, Hong-Sun;Yang, Seung-Shin
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.7 no.2
    • /
    • pp.109-117
    • /
    • 2005
  • In this study, the 1/20 reduced-scale experiments using Froude scaling were conducted to investigate the ventilation velocity of the variation of burning rate in tunnel fires. The heptane square pool fire with heat release rate ranging from 3.71~15.6 kW were used. The burning rate of fuel was obtained by measuring mass using load cell and temperature distributions were measured by K-type theomocouples in order to investigate smoke movement. The ventilation velocity in the tested tunnel was controlled by inverter of the wind tunnel. In heptane pool fire case, the increase in ventilation velocity incresed the burning rate due to the direct supply of oxygen to the fire plume. For the same dimensionless velocity($\bar{V}$), burning rate increased as the size of pool fire decreased.

  • PDF

A new derivation method of the generalized Jacobian matrix of a space robot and its application to a multi-robot system

  • Kobayashi, Jun;Nakatsuka, Keiichi;Katoh, Ryozo;Ohkawa, Fujio
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1997.10a
    • /
    • pp.799-802
    • /
    • 1997
  • This paper deals with a new method to derive the Generalized Jacobian Matrix of a space robot. In a conventional method to derive the Generalized Jacobian Matrix, generalized coordinates select Joint angles and a space robot body's position and attitude angle. But, in this paper, we select position and attitude angle of the end-effector or the handled floating object as generalized coordinates. Then, we can derive the Generalized Jacobian Matrix of the system which consists of several space robots and a handled floating object. Moreover control methods operated by only one space robot can be easily extended to the cases of cooperation task by several space robots. Computer simulations show that the Generalized Jacobian Matrix derived here is effective.

  • PDF

Influence Factors on Job Satisfaction Factor and Spatial Environments Evaluation of Fire-Fighting Officer - Focused on Fire Officials in Incheon Metropolitan City - (소방공무원의 직무만족요소에 의한 공간만족평가 영향에 관한 연구 - 인천지방 소방공무원을 중심으로 -)

  • Han, Myoung-Heum
    • Korean Institute of Interior Design Journal
    • /
    • v.25 no.6
    • /
    • pp.61-69
    • /
    • 2016
  • A study on how fire officer's job satisfaction factors influence space satisfaction rates. This article will conduct regression analysis for the study on these three problems. 'What are the factors of fire officer's job satisfaction?', 'Does space satisfaction rates influence job satisfaction rates?', 'Which job satisfaction factor influence space satisfaction rate?' Therefore, variables were set based on the prior study, and before regression analysis was conducted, variables were purified through analysis on primary factor and reliability analysis, and hypothesis test was done via variable calculation. According to the prior study, factors that influence job satisfaction rates are as following; self-regulation of tasks, ethics and responsibility level, relationship with colleagues, job identity. And regression analysis showed that space satisfaction rates do not influence job satisfaction rates. The writer thinks that it's showing that Korean fire officers tend to prioritize colleague relationship and job identity over space improvements. And the factor that influence job satisfaction rates turned out to be the self-regulation of tasks, and the writer estimates that it's reflecting the hierarchical organization culture of current Korean fire officers. Therefore, future Korean fire station design plans need to consider a space plan that provides fire officer's private self-regulation of tasks.