• 제목/요약/키워드: South Korea Power System

검색결과 269건 처리시간 0.033초

비상시 선로혼잡 해결을 위한 직접부하제어 (Direct Load Control Scheme for Congestion Problems in Power System Emergency)

  • 신호성;김병수;송경빈;김재철;이학주;권성철
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2005년도 춘계학술대회논문집
    • /
    • pp.307-310
    • /
    • 2005
  • Most of the electric power in the power system of South Korea is flowing from the south area to the north area, Seoul, in the capital of South Korea. Almost of the needs of the electric power in the capital area are about 43% of the total loads and generation plants are mainly located in the south area of South Korea. As mentioned the earlier characteristic, transmission congestion is one of the important research issues. Because of the limits of the power flows from the south to the north which are anticipated to be increased more and more in the future, these congestion situations may cause a serious voltage stability problem in emergency of the power system. Accordingly, we are interested in an interruptible load control program so as to solve this problem in emergency. This problem can be solved by an interruptible load management in emergency, however, the systematic and effective mechanism has not been presented yet. In this paper, the algorithm of interruptible load management plan using the line sensitivity to the loads for the transmission congestion management in emergency is presented. The proposed method is applied to 6-Bus sample system and their results are presented.

  • PDF

경인지역 전력불균형 대책 시나리오 및 조류계산 (Scenario & Load Flow for Power Unbalance Resolution in Kyung-In Area)

  • 이세정;김태균;김용학;장경철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.291-293
    • /
    • 2003
  • Energy markets of the Northeast Asia countries and in particular South Korea are perspective enough from the standpoint of export of energy resources from Russia. South Korea Power System has been rapidly growing. However, recently it has been confronted with difficulties in regard to constructing new Power Stations and especially Hydro Power Plants. Therefore it is mutually beneficial to build electric tie to South Korea in order to use highly effective Power of Northeast Asia. In this paper, we describe the maximum available transmission power through interconnected line without loss of stability in power system. For this simulation, the AC transmission system is assumed appropriate for this preliminary study. The transmission system will pass through territory of North Korea and connect to 765 kV Network near Seoul with long distance.

  • PDF

남북전력협력을 위한 전력계통 연계방안의 전압안정도 분석 (Voltage Stability Analysis for Power System Interconnection between North and South in Korea Peninsula)

  • 신중린;김병섭;최열준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 춘계학술대회 논문집 전력기술부문
    • /
    • pp.103-107
    • /
    • 2001
  • This paper presents a proposal for the power system interconnection alternative between the South and North Korea. The characteristics of bus voltage and power flow are analized to see the feasibility of the proposed and to evaluate the voltage atability. We collect and estimate various data of the South and North Korea power network. and the various case studies using the PowerWorld simulator were made to find the aceeptable interconnection alternative.

  • PDF

A Proposal for Power System Linkage between South and North in Korean Peninsula under the Current Situation

  • Shin, Joong-rin;Kim, Byung-Seop
    • KIEE International Transactions on Power Engineering
    • /
    • 제12A권2호
    • /
    • pp.39-44
    • /
    • 2002
  • This paper proposes some alternatives fur the power system linkage between South and North Korea, under the current situation. Since little information and data on the North-Korean power system are available so far, many efforts have been made to collect the required data for the North system as much as possible if available, and suppose, estimate and/or conjecture many things otherwise. Using these collected or assumed data, the characteristics of bus voltage and power flow are being studied to estimate the feasibility of the proposed linkage alternatives. To this end, many case studies have been made to examine the performance of acceptable interconnection alternatives.

22.9kV 고온 초전도 케이블.초전도 한류기 스마트 그리드 적용을 위한 초전도 시범사업 (Introduction of The First Demonstration Project for the Application of HTS Cable and SFCL to Real Smart Grid in South Korea)

  • 양병모;박진우;이승렬
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제12권3호
    • /
    • pp.34-38
    • /
    • 2010
  • Until now some countries including South Korea have made big progress and many efforts in the development of high temperature superconductor (HTS) power equipments. Especially, HTS Cable and superconducting fault current limiter (SFCL) are the strongest candidates among them from the viewpoint of applying to real grid. In South Korea, HTS cable and SFCL have been installed in test fields and tested successfully at Gochang PT Center of KEPCO. In order to meet practical requirements and be feasible in real grid, a demonstration project for HTS cable and SFCL systems, called GENI(green superconducting electric power network at Icheon substation) project, has been initiated to install 23kV HTS cable and SFCL systems in a utility network in South Korea since 2008. Namely, it says the first demonstration project for the application HTS system to real smart grid in South Korea. This paper presents the design and the application plan of the 22.9kV HTS cable and SFCL in 154kV Icheon substation in South Korea with the viewpoint of applying in Smat Grid.

울산 남동부 해안지역에서의 소용량 풍력발전 가능성에 관한 연구 (A Study of Wind-power Generations at the south-east coast of Ul-san)

  • 박문동;백민식;이간운;이영수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2003년도 하계학술대회 논문집 B
    • /
    • pp.1392-1394
    • /
    • 2003
  • This paper presents the actual test data of 3 phase, 9 pole, 3.6 [kw] synchronized wind-power generator controlled by hinged vane system and the possibilities of the small mount wind-power generations at the south-east coast of Ul-san. It also shows the data of the wind-velocity acquired by wind-direction sensor, calculation and analysis of the estimated electrical generation power, energy storage systems, and the efficient usages of the wind-power system.

  • PDF

Northeast Asia Interconnection, and Power Flow Analysis Considering Seasonal Load Patterns

  • Lee, Sang-Seung;Kim, Yu-Chang;Park, Jong-Keun;Lee, Seung-Hun;Osawa, Masaharu;Moon, Seung-Il;Yoon, Yong-Tae
    • Journal of Electrical Engineering and Technology
    • /
    • 제2권1호
    • /
    • pp.1-9
    • /
    • 2007
  • This paper presents the effects of an increase or a decrease of a power reserve by load flow calculations under the seasonal load patterns of each country for the future power shortages faced by the metropolitan areas or by the southeastern area of South Korea in North-East Asia. In this paper, the various cases of the power system interconnections in Far-East Asia are presented, and the resulting interconnected power systems are simulated by means of a power flow analysis performed with the PSS/E 28 version tool. Data for simulation were obtained from the 2-th long term plan of electricity supply and demand in KEPCO. The power flow map is drawn from simulated data and the comparative study is done. In the future, a power flow analysis will be considered to reflect the effects of seasonal power exchanges. And the plan of assumed scenarios will be considered with maximum or minimum power exchanges during summer or winter in North-East Asian countries.

남해안 어촌주거시설의 전력 소비량 실측 (A Measurement of electricity power consumption of houses located at south coastal fishing village)

  • 구재혁;조형오;황광일
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2012년도 춘계학술대회
    • /
    • pp.50-51
    • /
    • 2012
  • 해안 및 도서지역의 전력수요를 파력, 조력, 조류, 해상풍력과 같은 해양발전 시스템을 이용하는 혁신적인 고효율 하이브리드 알고리즘과 기본 모듈을 개발하기 위하여 2011년 8월부터 2012년 2월까지 남해안 도서지역 중 1개 섬을 선택하여 섬에 거주하고 있는 주민의 가구에 전력량 측정기를 설치하여 소비전력량 패턴을 확인하였다.

  • PDF

남해안 어촌 주거시설의 하절기 전력소비 실태 조사 (A Survey on the Electricity Power Consumption in Summer of Residential Areas at Island on South Coast)

  • 구재혁;조형오;황광일
    • 한국항해항만학회:학술대회논문집
    • /
    • 한국항해항만학회 2011년도 추계학술대회
    • /
    • pp.136-137
    • /
    • 2011
  • 해안 및 도서지역의 전력수요를 파력, 조력, 조류, 해상풍력과 같은 해양발전 시스템을 이용하는 혁신적인 고효율 하이브리드 알고리즘과 기본 모듈을 개발하기 위하여 2011년 하절기 남해안 도서지역 중 1개 섬을 선택하여 섬에 거주하고 있는 주민의 가구에 전력량 측정기를 설치하여 소비전력량 패턴을 확인하였다.

  • PDF

비정질 실리콘 투과형 태양전지를 적용한 BIPV 시스템 발전 성능에 관한 사례 연구 (A Case Study on the Power Performance Characteristics of Building Integrated PV System with Amorphous Silicon Transparent Solar Cells)

  • 정선미;송종화;이성진;윤종호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2009년도 춘계학술대회 논문집
    • /
    • pp.49-52
    • /
    • 2009
  • Practical building integrated photovoltaic system built by Kolon E&C has been monitored and evaluated with respect to power generation, which was installed in Deokpyeong Eco Service Area in Deokpyeong, Gyeonggi, Korea. The amorphous silicon transparent PV module in this BIPV system has 44Wp in power output per unit module and 10% of transmittance with the unit dimension with $980mm{\times}950mm$. The BIPV system was applied as the skylight in the main entrance of the building. This study provided the database for the practical application of the transparent thin-film PV module for BIPV system through 11 month monitoring as well as various statistical analyses such as monthly power output and insolation. Average monthly power output of the system was 52.9kWh/kWp/month which is a 60% of power output of the previously reported data obtained under $30^{\circ}$of an inclined PV module facing south(azimuth=0). This lower power output can be explained by the installation condition of the building facing east, west and south, which was resulted from the influence of azimuth.

  • PDF