• 제목/요약/키워드: Source to surface distance (SSD)

검색결과 29건 처리시간 0.029초

High-Dose-Rate Electron-Beam Dosimetry Using an Advanced Markus Chamber with Improved Ion-Recombination Corrections

  • Jeong, Dong Hyeok;Lee, Manwoo;Lim, Heuijin;Kang, Sang Koo;Jang, Kyoung Won
    • 한국의학물리학회지:의학물리
    • /
    • 제31권4호
    • /
    • pp.145-152
    • /
    • 2020
  • Purpose: In ionization-chamber dosimetry for high-dose-rate electron beams-above 20 mGy/pulse-the ion-recombination correction methods recommended by the International Atomic Energy Agency (IAEA) and the American Association of Physicists in Medicine (AAPM) are not appropriate, because they overestimate the correction factor. In this study, we suggest a practical ion-recombination correction method, based on Boag's improved model, and apply it to reference dosimetry for electron beams of about 100 mGy/pulse generated from an electron linear accelerator (LINAC). Methods: This study employed a theoretical model of the ion-collection efficiency developed by Boag and physical parameters used by Laitano et al. We recalculated the ion-recombination correction factors using two-voltage analysis and obtained an empirical fitting formula to represent the results. Next, we compared the calculated correction factors with published results for the same calculation conditions. Additionally, we performed dosimetry for electron beams from a 6 MeV electron LINAC using an Advanced Markus® ionization chamber to determine the reference dose in water at the source-to-surface distance (SSD)=100 cm, using the correction factors obtained in this study. Results: The values of the correction factors obtained in this work are in good agreement with the published data. The measured dose-per-pulse for electron beams at the depth of maximum dose for SSD=100 cm was 115 mGy/pulse, with a standard uncertainty of 2.4%. In contrast, the ks values determined using the IAEA and AAPM methods are, respectively, 8.9% and 8.2% higher than our results. Conclusions: The new method based on Boag's improved model provides a practical method of determining the ion-recombination correction factors for high dose-per-pulse radiation beams up to about 120 mGy/pulse. This method can be applied to electron beams with even higher dose-per-pulse, subject to independent verification.

RW3 고체팬텀에서 고에너지 X-선에 대한 전리함 반응보정인자의 특성에 관한 연구 (Study on the Characteristics of Response Correction Factor of Ionization Chamber in RW3 Solid Phantom for High Energy X-rays)

  • 이정옥;정동혁;김부길
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제32권2호
    • /
    • pp.205-212
    • /
    • 2009
  • 반응보정인자(h)는 고체팬텀에서 전리함의 반응을 물에서의 값으로 변환하기 위한 인자이다. RW3 고체 팬텀의 경우에 고에너지 X-선에 대한 반응보정인자는 선질과 깊이에 의존하는 것으로 알려져 있으나 조사면 크기와 SSD(Source to surface distance), 그리고 전리함 종류에 따른 의존성은 알려진 바가 없다. 본 연구에서는 알려진 의존성을 고찰하고 알려지지 않은 인자들에 대한 의존성을 조사하였다. 본 측정에서는 파머형전리함(FC65G, IBA, Germany)과 소형전리함(CC13, IBA, Germany)이 사용되었으며 대상 선질은 6 MV와 15 MV X-선이었다. 측정 결과 반응보정인자는 6 MV의 경우에 깊이 5 cm와 10 cm에서 각각 h = 1.015, 1.021, 그리고 15 MV의 경우에 깊이 5와 10 cm에서 각각 h = 1.024, 1.029로 나타났다. 결론적으로 반응보정인자는 선질과 깊이에는 의존하였지만 조사면 크기와 SSD에 따른 변화는 적었다. 전리함에 있어서 대상의 두 전리함에 대해서는 차이가 없었으나 다른 종류의 전리함에 대해서 추가적 연구가 필요하다고 생각한다. 본 결과는 RW3에서 전리함을 이용한 측정시 측정값의 분석에 활용될 수 있다.

  • PDF

진단용 X선을 이용한 방사선검사에서 차폐체 모양과 부가필터 변화에 따른 난소의 선량 분석 (A Dose Analysis on the Ovary According to the Type of Shielding Material and the Change of Additional Filter in Radiography Using Diagnostic X-ray)

  • 최준호
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제42권6호
    • /
    • pp.429-434
    • /
    • 2019
  • The gonads are directly affected by radiation exposure during radiography of the pelvis, abdomen, and spine. Exposure of the gonads to radiation can cause genetic mutations and can result in the occurrence of malignant tumors. In this study, we created three types of shielding material shapes for shielding of the ovaries, which are the gonads of female during radiography of the pelvis, and comparative evaluations using shadow shielding methods. The source surface distance(SSD) was 100 cm and the field size was 42 cm × 43 cm. The three types of shielding material shapes(type 1, 2 and 3) were assessed and the entrance surface dose in the ovaries were measured. The thickness of the shielding material was expanded from 0.3 mm to 2.4 mm and after five repetitions, radiation values were measured and mean values were calculated. The mean dose were 3.09 mGy for type 1, 3.54 mGy for type 2, and 3.19 mGy for type 3, indicating that the measurements were the lowest for type 1. When an additional filter of 0.2 Cu + 1 Al was used, the dose were 3.72 mGy for type 1, 5.43 mGy for type 2, and 4.05 mGy for type 3, indicating that the measurements were the lowest for type 1. The results show that, even if the shielding material is not thick, in other words, even with a thickness of 2.94 mGy for the SN 3(0.9 mm) of type 1, shielding can be achieved, with a patient dose lower than the diagnostic reference level(3.42 mGy). Additionally, among the three types of shielding material, the type 1 appeared to be the most appropriate shielding material. It is thought that the use of shielding material could reduce the risk factors for stochastic effects or critical effects of ionizing radiation during pelvic or lumbar radiography.

Development of a Wide Dose-Rate Range Electron Beam Irradiation System for Pre-Clinical Studies and Multi-Purpose Applications Using a Research Linear Accelerator

  • Jang, Kyoung Won;Lee, Manwoo;Lim, Heuijin;Kang, Sang Koo;Lee, Sang Jin;Kim, Jung Kee;Moon, Young Min;Kim, Jin Young;Jeong, Dong Hyeok
    • 한국의학물리학회지:의학물리
    • /
    • 제31권2호
    • /
    • pp.9-19
    • /
    • 2020
  • Purpose: This study aims to develop a multi-purpose electron beam irradiation device for preclinical research and material testing using the research electron linear accelerator installed at the Dongnam Institute of Radiological and Medical Sciences. Methods: The fabricated irradiation device comprises a dual scattering foil and collimator. The correct scattering foil thickness, in terms of the energy loss and beam profile uniformity, was determined using Monte Carlo calculations. The ion-chamber and radiochromic films were used to determine the reference dose-rate (Gy/s) and beam profiles as functions of the source to surface distance (SSD) and pulse frequency. Results: The dose-rates for the electron beams were evaluated for the range from 59.16 Gy/s to 5.22 cGy/s at SSDs of 40-120 cm, by controlling the pulse frequency. Furthermore, uniform dose distributions in the electron fields were achieved up to approximately 10 cm in diameter. An empirical formula for the systematic dose-rate calculation for the irradiation system was established using the measured data. Conclusions: A wide dose-rate range electron beam irradiation device was successfully developed in this study. The pre-clinical studies relating to FLASH radiotherapy to the conventional level were made available. Additionally, material studies were made available using a quantified irradiation system. Future studies are required to improve the energy, dose-rate, and field uniformity of the irradiation system.

Verification of Mechanical Leaf Gap Error and VMAT Dose Distribution on Varian VitalBeamTM Linear Accelerator

  • Kim, Myeong Soo;Choi, Chang Heon;An, Hyun Joon;Son, Jae Man;Park, So-Yeon
    • 한국의학물리학회지:의학물리
    • /
    • 제29권2호
    • /
    • pp.66-72
    • /
    • 2018
  • The proper position of a multi-leaf collimator (MLC) is essential for the quality of intensity-modulated radiation therapy (IMRT) and volumetric modulated arc radiotherapy (VMAT) dose delivery. Task Group (TG) 142 provides a quality assurance (QA) procedure for MLC position. Our study investigated the QA validation of the mechanical leaf gap measurement and the maintenance procedure. Two $VitalBeam^{TM}$ systems were evaluated to validate the acceptance of an MLC position. The dosimetric leaf gaps (DLGs) were measured for 6 MV, 6 MVFFF, 10 MV, and 15 MV photon beams. A solid water phantom was irradiated using $10{\times}10cm^2$ field size at source-to-surface distance (SSD) of 90 cm and depth of 10 cm. The portal dose image prediction (PDIP) calculation was implemented on a treatment planning system (TPS) called $Eclipse^{TM}$. A total of 20 VMAT plans were used to confirm the accuracy of dose distribution measured by an electronic portal imaging device (EPID) and those predicted by VMAT plans. The measured leaf gaps were 0.30 mm and 0.35 mm for VitalBeam 1 and 2, respectively. The DLG values decreased by an average of 6.9% and 5.9% after mechanical MLC adjustment. Although the passing rates increased slightly, by 1.5% (relative) and 1.2% (absolute) in arc 1, the average passing rates were still within the good dose delivery level (>95%). Our study shows the existence of a mechanical leaf gap error caused by a degenerated MLC motor. This can be recovered by reinitialization of MLC position on the machine control panel. Consequently, the QA procedure should be performed regularly to protect the MLC system.

Co-60에 의한 전신조사시 선량분포 (Dose Distribution of Co-60 Photon Beam in Total Body Irradiation)

  • Kang, Wee-Saing
    • 한국의학물리학회지:의학물리
    • /
    • 제2권2호
    • /
    • pp.109-120
    • /
    • 1991
  • 골수이식을 받게 될 환자의 이상 골수를 완전히 죽이기 위해 MV 정도의 선질의 광자선에 의한 전신방사선요법이 시행되고 있다. 국소방사선요법에 이용되고 있는 방사선치료장치에 의한 일상적인 방법으로 환자의 전선에 걸쳐 방사선을 조사하기에는 조사면의 크기가 훨씬 미치지 못한다. 그래서 환자의 전선에 걸쳐 방사선을 조사할 수 있는 방법이 개발되어야 한다. 방사선 전신조사를 위한 여건이 병원에 따라 다를 것이기 때문에 병원에 따라 독특한 방법이 개발될 수 있다. 서울대학교병원에서는 코발트치료기 만이 두부를 기울일 수 있어서 전신조사에 이용될 수 있다. 코발트치료기의 두부를 밖으로 90$^{\circ}$ 기울일 때 선축은 수평이고 또한 맞은편 벽과 직각이 된다. 이 때 선원에서 맞은편 벽가지 거리는 319cm 이였다. 벽에서 환자의 중앙시상면까지 간격을 40cm라고 가정할 때, 중앙시상면에서 명목상 최대 조사면 크기가 122cm$\times$122em 이였고, 조사선량 분포를 측정한 결과로는 130cm$\times$129cm 이였으며 상하방향에서는 대칭이 아니였다. 환자가 쭈그리고 앉은 자세를 취한다면 조사면의 크기는 전신조사를 시행할 수 있을 정도로 충분히 크다. 환자 좌우폭의 평균을 30cm 라고 가정하고, 중앙시상면에서 선원쪽 15cm 위치에 기준표면 (SSD는 264cm, 명목상 조사면 크기 115.5cm$\times$155.5cm)을 두고 단면의 크기가 25cm$\times$25cm이고 두께가 30cm 인 폴리스티렌 팬톰에서 평판형 전리함으로 PDD를 측정하였다. 최대선량점의 깊이는 0.3cm 이였고 표면선량율은 82%, 50% 깊이는 16.9cm였다. 대향조사시 선축상 선량분포는 중점의 선량에서 10%이내로 일치하였다. SCD를 279cm. 최대 조사면, 기준깊이 15cm 에 대한 TPR 을 폴리스티렌 팬톰에서 깊이 10cm 에서 20cm 에 걸쳐 측정하였다 . 측정범위에서 TPR 은 직선성을 보였다. 인체팬톰의 최대 전단면(coronal plane) 에 있는 각 구멍에 TLD 조각을 넣고, 코발트 선원에서 팬톰의 시상면까지 거리를 279cm 되게 하고 선축은 팬톰의 27번 절편과 28번 절편의 접변과 최대 전단면의 교차선과 일치시켜 양방향에서 15분씩 조사하여 전단면에서 선량을 측정하였다. 팬톰내 선축상 중앙점의 선량을 기준으로 다른 부위의 선량을 비교하였다. 두경부와 복부, 폐의 하반에서 선량의 차이는 $\pm$ 10% 이내였고, 폐의 상반과 어깨와 골반 부위에서 선량은 10%이상 저선량을 보였다. 특히 어깨부위에는 30%이상 저선량을 보였다. 이로부터 서울대병원과 유사한 조건에서 코발트로 전신조사하는 경우에는 폐나 두경부에 대응하는 조직보상체를 이용하기보다는 어깨부위에 선량을 추가하는 것이 바람직할 것이라고 생각한다.

  • PDF

고정형쐐기(Physical Wedge)와 동적쐐기(Dynamic Wedge)의 조사야 주변 선량에 관한 연구 (A Study of Peripheral Doses for Physical Wedge and Dynamic Wedge)

  • 민제순;나경수;이제희;박흥득
    • 대한방사선치료학회지
    • /
    • 제19권2호
    • /
    • pp.77-82
    • /
    • 2007
  • 목 적: 목적: 2D-ARRAY chamber를 이용하여 고정형쐐기(Physical wedge filter)와 동적쐐기(Dynamic wedge)의 조사야 주변의 선량을 비교하여 평가하였다. 대상 및 방법: 고체팬텀위에 2D-ARRAY seven29 (PTW, Germany) chamber를 이용하여 조사야 10$\times$10, SSD 90 cm로 고정시키고 에너지는 6 MV와 15 MV로 변화시켜 5 mm 깊이의 조사야 밖 선량을 측정하였다. 쐐기필터15$^\circ$, 45$^\circ$동적쐐기와 선형가속기에 장착된 동적쐐기의 15$^\circ$, 45$^\circ$를 측정하여 조사야 끝에서 쐐기의 heel부분과 toe부분의 1 cm 되는 지점에서 5 cm 지점까지의 1 cm 간격으로 주변선량을 비교, 분석하였다. 선량은 최대선량지점에 대한 표면에 근접한 5 mm 깊이와 5 cm 깊이의 백분율로 선량값을 얻었다. 결 과: 6 MV 에너지는 동적쐐기가 고정형쐐기보다 조사야 주변 선량이 0.1$\sim$1.4%정도 모두 낮았다. 15 MV 에너지는 조사야에서 근접한 거리에서 동적쐐기의 선량이 0.4$\sim$0.9%정도 높지만 멀어지면서 급격하게 감소하여 동적쐐기가 최대 1.6% 낮게 측정되었다. 경사각 15$^\circ$와 45$^\circ$에서의 선량차이는 크지 않았으며, 동적쐐기는 heel 부분과 toe부분의 선량차이가 없는 반면 고정형쐐기는 에너지가 크고 쐐기 각도가 클수록 heel부분 보다 toe부분의 선량이 2%정도 높게 측정되었다. 결 론: 동적쐐기와 고정형 쐐기가 조사야 내에서는 같은 선량분포를 갖는 반면 조사야 주변에서는 동적쐐기가 고정형쐐기보다 선량이 낮았다. 따라서 동적쐐기를 사용할 경우 치료주위선량을 감소시킬 수 있으므로 치료부위와 근접한 표면에 가까운 주요장기의 선량을 최소화 할 수 있으며, 치료시간도 단축시킬 수 있었다.

  • PDF

고정형 쐐기(Physical wedge)와 동적 쐐기(Dynamic wedge)의 조사야 주변 선량에 관한 연구 (A Study of Peripheral Doses for Physical Wedge and Dynamic Wedge)

  • 고신관;민제순;나경수;이제희;박흥득;한동균
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제31권4호
    • /
    • pp.407-413
    • /
    • 2008
  • 2D-ARRAY chamber를 이용하여 고정형쐐기(Physical wedge filter)와 동적쐐기(Dynamic wedge)의 조사야 주변의 선량을 비교 평가하고자 하였다. 고체팬텀 위에 2D-ARRAY seven 29 (PTW, Germany) chamber를 이용하여 조사야 $10cm{\times}10cm$, SSD 90cm로 고정시키고, 에너지는 6MV와 15MV로 변화시켜 산란선의 영향을 많이 받는 피부 깊이인 5mm 깊이의 조사야 밖 인접 선량을 측정하였다. 고정형 쐐기 $15^{\circ}$, $45^{\circ}$와 선형가속기에 장착된 동적쐐기의 $15^{\circ}$, $45^{\circ}$를 측정하여 조사야 끝에서 쐐기의 heel부분과 toe 부분의 1cm되는 지점에서 5cm 지점까지의 1cm 간격으로 주변선량을 비교, 분석하였다. 6MV 에너지는 동적쐐기가 고정형쐐기 보다 조사야 주변 선량이 $0.1{\sim}1.4%$ 정도 모두 낮았다. 15MV 에너지는 조사야에서 근접한 거리에서 동적쐐기의 선량이 $0.4{\sim}0.9%$ 정도 높지만 멀어지면서 급격하게 감소하여 동적쐐기가 최대 1.6% 낮게 측정 되었다. 동적쐐기는 heel부분과 toe부분의 선량차이가 없는 반면 고정형쐐기는 에너지가 높고 쐐기 각도가 클수록 heel부분 보다 toe부분의 선량이 2% 정도 높게 측정되었다. 따라서 동적쐐기를 사용할 경우 치료주위선량을 균일하게 감소시킬 수 있으므로 치료부위와 근접한 표면에 가까운 주요장기의 선량을 최소화 할 수 있었다.

  • PDF

CLINAC 1800 선형가속기의 15 MV X-선의 특성 (Characteristics of 15 MV Photon Beam from a Varian Clinac 1800 Dual Energy Linear Accelerator)

  • 김계준;이종영;박경란
    • Radiation Oncology Journal
    • /
    • 제9권1호
    • /
    • pp.131-141
    • /
    • 1991
  • 국내에서 처음으로 사용되는 CLINAC 1800에서 발생된 15MV X-선의 특성을 구하기 위하여 3 Dimensional water Phantom Dosimetry system)를 이용하여 방사선 치료에 근간이 되는 심부선량 백분율(POD), 최대 조직 비율(TMR), 편평도(beam profile), 대칭도, Wedge인자 등을 측정하였고 선량계산을 위하여 출력 인자들을 구하였다. 1. 선축상 최대치 지점(Dmax)은 SSD 100cm일때 조사면이 $10\times10cm^2$에서 $3.0\pm0.1$ cm이였고 $4\times4cm^2,\;35\times35cm^2$에서 각각 $3.1\pm0.1\;cm,2.2\pm0.1$ cm으로 조사면이 넓어지면서 측정치가 표면에 가까워지는 결과를 보였다. 2. 조직표면 선량(Surface Dose)는 SSD 100cm일때 조사면이 $10\times10cm^2$에서 $15.5\%$이였고 $4\times4cm^2,\;35\times35cm^2$에서 각각 $9.8\%\;,51.2\%$로 조사면이 넓어지면서 표면 선량은 증가하는 결과를 보였다. 3. 심부선량 백분율(PDO)은 SSD 100cm에서 측정하였고 조사면이 $10\times10cm^2$이고 10cm depth에서 $76.8\%$이였고 $80\%,\;50\%$ 선량의 깊이는 각각 $9.1\pm0.1\;cm,19.9\pm0.2\;cm$으로 측정되었다. 4. 최대조직비율(TMR)은 심부선량 백분율(PDD)로부터 계산하였고 측정값과의 차이는 $10\times10cm^2$ 조사면에서 평균 $1\;%$ 이내의 오차를 보였다. 5. 대칭도(symmetry)와 편평도(flatness)는 조사면 $10\times10cm^2$일때 각각 $0.73\%,\;2.72\%$이였다. 6. 출력인자(output factor)는 $10\times10cm^2$ 기준 조사면에서 흡수선량을 1로 하였을때 $4\times4cm^2,\;35\times35cm^2$ 조사면에서는 각각 0.927, 1.087로 측정되었는데 조사면이 증가할수록 흡수량이 증가하는 결과를 보였다. 7. Wedge factor는 $15^{\circ}\;30^{\circ}\;45^{\circ}\;60^{\circ}$를 10cm깊이에서 측정하였는데 0.825, 0.099, 0.560, 0.457로 각각 측정되었고 아크릴 0.4 mm Tray의 투과율은 0.976이였다. 8. 15 MV X-선에 의한 납벽층의 반가층 두께는 13 mm였고 Cerrobend의 반가층은 15.5 mm으로 측정되었다.

  • PDF

고에너지 선형가속기의 Independent Collimator를 이용한 비대칭 방사선 조사시 방사선량 결정에 미치는 요인에 관한 연구 (Dosimetric Characteristics of Dual Photon Energy Using Independent Collimator Jaws)

  • 김정기;최영민;이형힉;허원주
    • Radiation Oncology Journal
    • /
    • 제14권3호
    • /
    • pp.237-244
    • /
    • 1996
  • 목적 : 의료용 선형가속기의 Independent Collimator는 현재 광범위하게 사용되고 있다. 그러나 방사선량의 계산과 MU(Monitor Unit)의 계산에 사용되는 모든 기본 자료는 대칭 조사면를 기준으로 작성되었기 때문에 independent collimator를 사용한 비대칭적인 조사면의 경우 현재 사용하고 있는 계산 방식을 그대로 적용함에 무리가 있을 것으로 생각된다. 따라서 이러한 의문에 대한 체계적이고 과학적인 검토가 필요할 것으로 사료되어 본 연구를 진행하였다. 대상 및 방법 :본 연구는 Dual Photon Beam(6MV와 15MV)을 산출(産出)하는 선형가속기(Linac 1800, Varian Co)에서 collimator 사용시 산란 방사선의 총채로 표현되어지는 field size factor, beam qualify에 영향을 미치는 HVL와 PDD를 조사하였다. 먼저 field size factor는 water phantom(WP 600C Wellhofer, Germany)내의 Dmax에서 field size $3{\times}3cm$에서 $35{\times}35cm$까지의 방사선량의 변화를 square field로 $1cm^2$씩 증가시켜 가며 0.6cc ion chamber(NE 2571)로 측정하였다. Beam quality는 100cm SSD(source-surface distance)에서 $5{\times}5$, $10{\times}10$, $15{\times}15$$20{\times}20cm$ field size로 0, 3 및 10cm off-axis distance와 dmax 4, 10, 15 및 20cm의 깊이에서 측정하였다. Dose distribution을 분석하기 위하여 film densitometer와 water phantom(IC 10 ion chamber)을 사용, $10{\times}10cm$ field size에서 5, 10 및 15cm의 off-axis distance까지의 방사선량의 분포를 관찰하고 대칭 방사선 조사면와 비교 분석하여 실제 isodose 분포에 미치는 영향을 관찰하였다. 결과: 1) Relative field size factor는 중심 축에서 off-axis lateral distance에 따라 다양하게 변화하였는데 6MV X-선의 경우 최대 $3.1\%$, 15MV X-선의 경우 최대 $5\%$까지의 변화를 보였다. 이때 off-axis factor를 구하여 교정을 하였을 경우 중심 축의 field size factor와 거의 유사한 값에 도달할 수 있었다. 2) Beam qualify의 변화를 관찰하기 위한 실험에서 HVL는 off-axis distance가 멀어질수록 감소하였고 PDD도 off-axis distance가 멀어지고 측정 깊이가 깊어질수록 감소되는 현상을 보였다. 통상적인 방사선 치료시에 이용되는 $5{\times}5cm$ 이상의 field size와 15cm 이내의 깊이에서는 3cm 와 l0cm의 off-axis에서 6MV X-선은 평균 $0.5\%$$2\%$, 15MV X선은 $0.4\%$$1.4\%$의 감소 현상을 보여 큰 편차를 관찰할 수 없었다. 3) Isodose distribution은 off-axis distance가 멀어질수록 depth dose의 증가치가 감소되었으며 특히 central axis의 가장자리 부위에서는 isodose curve의 위축이 확연하였다. 결론 : Independent collimator를 사용하여 비대칭 방사선 치료를 할 경우 MU의 계산은 off-axis factor와 PDD 보정이 필수적이며 임상적으로는 중심 축에서의 과소조사에 대한 정밀한 주의가 필요할 것으로 사료된다.

  • PDF