• Title/Summary/Keyword: Source position detection

Search Result 93, Processing Time 0.028 seconds

Changes according to the geometry of the shield using MCNP code system (MCNP코드 시스템을 이용한 차폐물 geometry에 따른 결과 변화에 대한 연구)

  • Kang, Ki-byung;Lee, Nam-ho;Hwang, Young-kwan
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2013.05a
    • /
    • pp.1031-1033
    • /
    • 2013
  • Radiation protection, as well as finding the location of the radiation source, such as the Fukushima radiation leak accident, it is important for the early and safe disposal of nuclear accident. The three-dimensional position of the radiation source detection distance of the radiation source can provide additional information to the existing radiation detectors radiation of a two-dimensional position detection function and then it can play a decisive role in the radiation contaminant removal and decontamination work. In this research, three-dimensional semiconductor sensor based on dual radiation detectors radiation source device visible part of the research and development of efficient radiation sensor unit on the design of the shielding structure.The lightweight, high-efficiency radiation source locator implementation was attempted for the structure and thickness of the shielding and collimator to perform the simulation of the radiation shielding for the various parameters of the shape model through design the optimal structure of the MCNP-based heavy-duty tungsten shielding, lead shielding The results of this study, is a compact, lightweight three-dimensional radiation source detection and future of silicon - based sensors will be used in the study.

  • PDF

The Study Image Aquisition System for Radiation Source Using the Stereo Gamma-ray Detector (스테레오 감마선 탐지장치를 이용한 감마선원 분포측정 시스템에 관한 연구)

  • Hwang, Young-Gwan;Lee, Nam-Ho;Lee, Seung-Min
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.4
    • /
    • pp.197-203
    • /
    • 2015
  • Nuclear power plant has increased continuously for power production in all over the world and the interest about nuclear accident and the dismantling of aging nuclear power plant has been a growing. The leaked radioactive source that is generated by radiation accidents must detect and remove to minimized the damage as soon as possible. Gamma-ray detection system that have been developed until now cannot provide the precise position of radioactive sources because they detect and imaging the position of radiation sources in just two dimensions. In this paper, stereo gamma ray detection system has developed and the algorithm for calculation of the distance has implemented to be able to measure the distribution of the leakage gamma ray source for the system. Stereo camera calibration for distance detection was conducted with the correction pattern and LED light and we carried out performance test of the system for the LED light source and a gamma ray source. In both experiments the results of the performance test, it was confirmed to have a 5% error. The results of this paper is used as a material for the development of gamma-ray imaging device.

INTELLIGENT MIRROR ADJUSTMENT SYSTEM USING A DRIVER′S PUPILS

  • Rho, K.H.;Han, M.H.
    • International Journal of Automotive Technology
    • /
    • v.5 no.4
    • /
    • pp.277-285
    • /
    • 2004
  • This paper describes an intelligent mirror adjustment system that rotates a pair of side mirrors and the room mirror of a car to the optimal position for a driver by using the location of the driver's pupils. A stereo vision system measures the three-dimensional coordinates of a pair of pupils by analyzing the input images of stereo B/W CCD cameras mounted on the instrument panel. This system determines the position angle of each mirror on the basis of information about the location of the pupils and rotates each mirror to the appropriate position by mirror actuators. The vision system can detect the driver's pupils regardless of whether it is daytime or nighttime by virtue of an infrared light source. Information about the pair of nostrils is used to improve the correctness of pupil detection. This system can adjust side mirrors and the room mirror automatically and rapidly by a simple interface regardless of driver replacement or driver's posture. Experiment has shown this to be a new mirror adjustment system that can make up for the weak points of previous mirror adjustment systems.

Tunnel Detection Using Seismic Multi-source Amplitude Data (복수파동원의 탄성파 진폭법을 이용한 터널탐사에 관한 연구)

  • Suh, Baek-Soo;Kim, Hoon;Sohn, Kwon-Ik
    • Geophysics and Geophysical Exploration
    • /
    • v.10 no.4
    • /
    • pp.377-382
    • /
    • 2007
  • Several prospecting methods have been used to detect deep seated small tunnel in Korea. Tunnel interpretation of seismic method has been performed mainly by wave traveltime inversion method. But it often gives inacurate solution for the exact tunnel position because of the short distance between two measuring boreholes and picking errors of first arrivals. In this study, "error tomogram" was proposed to detect tunnel position and applied to theoretical and field dat using multi-source amplitude data.

Sound Source Localization Method Using Spatially Mapped GCC Functions (공간좌표로 사상된 GCC 함수를 이용한 음원 위치 추정 방법)

  • Kwon, Byoung-Ho;Park, Young-Jin;Park, Youn-Sik
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.19 no.4
    • /
    • pp.355-362
    • /
    • 2009
  • Sound source localization method based on the time delay of arrival(TDOA) is applied to many research fields such as a robot auditory system, teleconferencing and so on. When multi-microphones are utilized to localize the source in 3 dimensional space, the conventional localization methods based on TDOA decide the actual source position using the TDOAs from all microphone arrays and the detection measure, which represents the errors between the actual source position and the estimated ones. Performance of these methods usually depends on the number of microphones because it determines the resolution of an estimated position. In this paper, we proposed the localization method using spatially mapped GCC functions. The proposed method does not use just TDOA for localization such as previous ones but it uses spatially mapped GCC functions which is the cross correlation function mapped by an appropriate mapping function over the spatial coordinate. A number of the spatially mapped GCC functions are summed to a single function over the global coordinate and then the actual source position is determined based on the summed GCC function. Performance of the proposed method for the noise effect and estimation resolution is verified with the real environmental experiment. The mean value of estimation error of the proposed method is much smaller than the one based on the conventional ones and the percentage of correct estimation is improved by 30% when the error bound is ${\pm}20^{\circ}$.

A Speaker Detection System based on Stereo Vision and Audio (스테레오 시청각 기반의 화자 검출 시스템)

  • An, Jun-Ho;Hong, Kwang-Seok
    • Journal of Internet Computing and Services
    • /
    • v.11 no.6
    • /
    • pp.21-29
    • /
    • 2010
  • In this paper, we propose the system which detects the speaker, who is speaking currently, among a number of users. A proposed speaker detection system based on stereo vision and audio is mainly composed of the followings: a position estimation of speaker candidates using stereo camara and microphone, a current speaker detection, and a speaker information acquisition based on a mobile device. We use the haar-like features and the adaboost algorithm to detect the faces of speaker candidates with stereo camera, and the position of speaker candidates is estimated by a triangulation method. Next, the Time Delay Of Arrival (TDOA) is estimated by the Cross Power Spectrum Phase (CPSP) analysis to find the direction of source with two microphone. Finally we acquire the information of the speaker including his position, voice, and face by comparing the information of the stereo camera with that of two microphone. Furthermore, the proposed system includes a TCP client/server connection method for mobile service.

Development of Noise Source Detection System using Array Microphone in Power Plant Equipment (배열형 음향센서를 이용한 발전설비 소음원 탐지시스템 개발)

  • Sohn, Seok-Man;Kim, Dong-Hwan;Lee, Wook-Ryun;Koo, Jae-Raeyang;Hong, Jin-Pyo
    • KEPCO Journal on Electric Power and Energy
    • /
    • v.1 no.1
    • /
    • pp.99-104
    • /
    • 2015
  • In this study, it has been initiated to investigate the specific abnormal vibration signal that has been captured in the power equipment. Array Microphone can be used in order to detect the direction and the position of the noise source. It is possible to track the abnormal mechanical noise in the power plant by utilizing the program and the microphone array system developed from this research. Array microphone system can be operated as a constant monitoring system.

THE AKARI FIR ALL-SKY POINT SOURCE CATALOGUES: IMPROVEMENT ACTIVITIES

  • Makiuti, Sin'itirou;Yamamura, Issei;Koga, Tatsuya;Nakada, Tatsuya;AKARI team
    • Publications of The Korean Astronomical Society
    • /
    • v.32 no.1
    • /
    • pp.17-19
    • /
    • 2017
  • The first version of the AKARI far-infrared All-Sky Bright Source Catalogue (BSC ver.1) was released to public in March 2010. It has been widely used for various astrophysical researches. We are continuing efforts to produce the next edition. The new version is expected to be improved in accuracy and reliability, as well as its volume. Many improvements to the next version are in progress. The time-line signal is being re-examined throughout the entire data processing. Correction processes for signal linearity and detector responsivity, and procedure for masking signal anomaly are revised. The source extraction process is further tuned and operating parameters will be optimized. These bring better reliability of the source detection and possibly an increase of source numbers. The position accuracy is expected to be improved. Systematic position error seen around the Galactic plane will also be corrected. We also plan to deliver the Faint Source Catalogue version 1.

Study of seismic amplitude method using single source for tunnel detection (터널탐사에 단일 파동원을 이용한 탄성파 진폭법에 관한 연구)

  • Suh, Baek-Soo;Sohn, Kwon-Ik
    • Journal of Industrial Technology
    • /
    • v.27 no.A
    • /
    • pp.3-7
    • /
    • 2007
  • There are many techniques to calculate the exact position of deep seated tunnel. Especially, tomography method has been used generally in present days. This method has been performed mainly by wave traveltime. Because of short interval of two measuring boreholes, it was very hard to interpret the exact tunnel position. To solve this problem, seismic amplitude method was tried to detect exact pososition of tunnel in this study.

  • PDF