• 제목/요약/키워드: Source impedance

검색결과 378건 처리시간 0.023초

변형 SL-ZSI의 설계 및 제어 (Design and Control of Modified Switched Inductor-ZSI)

  • ;전태원;이홍희;김흥근;노의철
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 추계학술대회 논문집
    • /
    • pp.105-106
    • /
    • 2013
  • This paper proposes a new topology with active switched-capacitor and switched-inductor impedance network, which can obtain a high boost factor with small shoot-through time. The proposed topology uses an active switched capacitor and switched-inductor impedance network in order to couple the main circuit and input dc source for boosting the output voltage. The proposed topology contains all advantages of the classical Z-source inverter. Comparing with other topologies, the proposed topology uses lesser component and the voltage boost inversion ability significantly increases. The theoretical analysis, pulse width modulation control strategies, and a comparison with classical ZSI have been given in this paper. Both simulation and experimental results will be presented to verify the advantages of the proposed topology.

  • PDF

전원 임피던스 제어를 통한 도시철도 최대전력 최적화 (Peak Power Optimization for Metro Railway using by Source Impedance Control)

  • 김한수;권오규
    • 전기학회논문지
    • /
    • 제63권6호
    • /
    • pp.841-849
    • /
    • 2014
  • Urban railway with rectifiers is connected by parallel circuits because substations are joined by the power rail. Thus, if an input voltage of a substation is increased, then the voltage of rectifiers is also increased, and which leads to an increase in the peak power of the substation. To solve this problem, this paper proposes a new method reducing the peak power of substations by adjusting the operation number of rectifiers. Its feasibility is exemplified by some simulations performed for Incheon subway Line 1 and GA(Genetic Algorithm) method has been applied to obtain the optimal input. Simulation results show that peak power can significantly be reduced using the method proposed in this paper.

TWO TYPES OF ACTIVE NOISE CONTROL SYSTEM USING MFB LOUDSPEAKER

  • Nishimura, Yoshitaka;Shimada, Yasuyuki;Usagawa, Tsuyoshi;Ebata, Masanao
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1994년도 FIFTH WESTERN PACIFIC REGIONAL ACOUSTICS CONFERENCE SEOUL KOREA
    • /
    • pp.764-769
    • /
    • 1994
  • The impedance of an electro-acoustic transducer can be controlled by motional feedback, and the noise in a duct can be reduced actively by adjusting the impedance using an additional sound. In this paper, two approaches for active noise control using motional feedback (MFB) loudspeaker are described. First configuration uses an external sensor to pickup of source directly. In this configuration, the adaptation of controller is necessary to compensate the change of transfer function from noise source to control poing. The second configuration uses a new adaptive algorithm specialized for peridic noise. Because this configuration does not require any reference input and the error sensor couples very tightly with control loudspeaker, this MFB system itself is independent of the duct condition. No microphone are required in both configurations, so that a more reliable and stable active control system can be realized under severe conditions such as high pressure, high temperature, dust, flow and so on.

  • PDF

광대역 임피이던스정합용 불균일군차선로의 최적설계 (Optimal Design of Nonuniform Transmission Lime Sections for Wide-Band Impedance Matching)

  • 박송배
    • 대한전자공학회논문지
    • /
    • 제11권6호
    • /
    • pp.38-43
    • /
    • 1974
  • 임의의 전원임피이던스와 임의의 부하임피이던스 사이에 삽입할 때 입력반사계수가 가급적 넓은 주파수범위에서 최소가 되는 임피이던스 정합용 불균일선로 섹션을 설계하는 문제를 고찰하였다. 고려대상의 불균일선로는 수학적으로는 특수한 종류에 속하는 것이나 실제적으로는 완만하게 변하는 거의 모든 전송선로를 포괄할 수 있다. 입력반사 계수의 계산에서는 선로의 ABCD 파라미터의 테일러 급수전관식을 이용하였다. 그리고 설계문제를 비선형 구속조건을 가진 비선형 프로그래밍 문제로서 수식화하였으며 이것을 수차적비구속 최소법(Sequential Unconstrained Minimigation Technique)과 Fletcher-Powell 방법을 병용하여 풀었다. 결과적으로 이제까지 광대역 임피이던시 정합편 전송선제로서 발표된 가장 우수한 것보다 훨씬 특성이 개선된 것을 얻을 수 있었다.

  • PDF

Development of Bioelectric Impedance Measurement System Using Multi-Frequency Applying Method

  • Kim, J.H.;Jang, W.Y.;Kim, S.S.;Son, J.M.;Park, G.C.;Kim, Y.J.;Jeon, G.R.
    • 센서학회지
    • /
    • 제23권6호
    • /
    • pp.368-376
    • /
    • 2014
  • In order to measure the segmental impedance of the body, a bioelectrical impedance measurement system (BIMS) using multi-frequency applying method and two-electrode method was implemented in this study. The BIMS was composed of constant current source, automatic gain control, and multi-frequency generation units. Three experiments were performed using the BIMS and a commercial impedance analyzer (CIA). First, in order to evaluate the performance of the BIMS, four RC circuits connected with a resistor and capacitor in serial and/or parallel were composed. Bioelectrical impedance (BI) was measured by applying multi-frequencies -5, 10, 50, 100, 150, 200, 300, 400, and 500 KHz - to each circuit. BI values measured by the BIMS were in good agreement with those obtained by the CIA for four RC circuits. Second, after measuring BI at each frequency by applying multi-frequency to the left and right forearm and the popliteal region of the body, BI values measured by the BIMS were compared to those acquired by the CIA. Third, when the distance between electrodes was changed to 1, 3, 5, 7, 9, 11, 13, and 15 cm, BI by the BIMS was also compared to BI from the CIA. In addition, BI of extracellular fluid (ECF) was measured at each frequency ranging from 10 to 500 KHz. BI of intracellular fluid (ICF) was calculated by subtracting BI of ECF measured at 500 kHZ from BI measured at seven frequencies ranging from 50 to 500 KHz. BI of ICF and ECF decreased as the frequency increased. BI of ICF sharply decreased at frequencies above 300 KHz.

커프 압력 조절에 따른 혈류량 변화 평가를 위한 임피던스법의 구현 (Implementation of Impedance Method to Estimate Blood Flow Variation with Cuff Pressure Change)

  • 정도운;배진우;손정만;예수영;최병철;남기곤;김철한;전계록
    • 센서학회지
    • /
    • 제13권6호
    • /
    • pp.462-472
    • /
    • 2004
  • In this study, we measured the blood flow on arm by non-invasive method and implemented a system to measure variation of the blood flow by estimating bio-electrical impedance and arterial pressure according to cuff pressure. The implemented system measured impedance variation according to pressure variation applied by artificial cuff pressure on the measuring position. The system consisted of pressure measuring part and impedance measuring part using 4-electrode method. Pressure measuring part was composed of semiconductor pressure sensor and electronic circuit for signal processing of sensor output signal. In addition, impedance measuring part was composed of constant current source circuit and lock-in amplifier for detecting impedance signal. We conducted experiments of impedance measuring part using standard resistance for performance evaluation of the implemented system. In addition we experimented to estimate variation of the blood flow by measuring impedances of the experimental group. We estimated ratio of the blood flow resistance using mean arterial pressure and variation of the blood flow. As a result the ratio of the blood flow resistance and variation of blood flow were in an inverse relationship with each other and the correlation coefficient was -0.96776.

진동원으로부터 지지구조물에 전달되는 진동 파워의 추정 - 수평방향으로 전달되는 진동파워의 추정 및 측정 - (Estimation of Vibrational Power Transmitted from Vibration Source to Supporting Structure - Estimation and Measurement of Vibrational Power Transmitted in the Horizontal Direction -)

  • 김재철;주진수
    • 소음진동
    • /
    • 제8권6호
    • /
    • pp.1137-1143
    • /
    • 1998
  • This paper describes the method to measure of the vibrational power transmitted from the vibration source to the supporting structure in the horizontal direction. Generally, it is impossible to measure horizontal forces at the coupling points. However. the vibrational Power transmitted in the horizontal direction can be measured by using indirect method that is based on the mechanical impedance and velocities at the coupling points. We proposed the method to estimate the vibrational power when the vibration source and supporting structure cannot be separated. In this paper. the vibrational power transmitted in the horizontal direction is also estimated by using this method. The estimated and measured results of the mobilities at the coupling point and vibrational power in the horizontal direction are compared. It is shown that the estimated results agree well with the measured results. For the supporting structure with multiple coupling points, the other coupling points should be considered for measuring the vibrational power transmitted through one coupling points. We examine the effects of other coupling points and measure the vibrational power without considering the other coupling points.

  • PDF

Evaluation and Comparison of the Low-Frequency Oscillation Damping Methods for the Droop-Controlled Inverters in Distributed Generation Systems

  • Tao, Yong;Deng, Yan;Li, Guangdi;Chen, Guipeng;He, Xiangning
    • Journal of Power Electronics
    • /
    • 제16권2호
    • /
    • pp.731-747
    • /
    • 2016
  • The droop-based control strategy is widely applied in the interfacing inverters for distributed generation. This can be a problem since low-frequency stability issues may be encountered in droop-based microgrid. The objective of this paper is to classify, evaluate and compare various low-frequency damping methods. First, low-frequency stability problems are analyzed and an equivalent model of a droop-controlled inverter is investigated to classify the damping methods into the source-type damping strategies and the impedance-type damping strategies. Moreover, the lead-lag compensation network insertion control is proposed as a beneficial part of the source-type damping strategies. Then, the advantages and disadvantages of the different types of damping methods are theoretically evaluated and experimentally tested. Furthermore, the damping methods are comprehensively compared to illustrate the application field of each method. Finally, the synthesis of different damping methods to enhance the low-frequency stability is discussed and experimental validation is presented.

Large Area Plasma for LCD Processing by Individyally Controlled Array Sources

  • Kim, Bong-Joo;Kim, Chin-Woo;Park, Se-Geun;Lee, Jong-Geun;Lee, Seung-Ul;Lee, Il-Hang;O, Beom-Hoan
    • Journal of Information Display
    • /
    • 제3권2호
    • /
    • pp.26-30
    • /
    • 2002
  • Large area plasma source has been built for LCD etcher by an array of $2{\times}2$ ICP sources. Since only one RF power supply and one impedance matching network is used in this configuration, any difference in impedances of unit RF antennas causes unbalanced power delivery to the unit ICP. In order to solve this unavoidable unbalance, unit antenna is designed to have a movable tap, with which the inductance of each unit can be adjusted individually. The plasma density becomes symmetric and etch rate becomes more uniform with the impedance adjustment. The concept of adding axial time-varying magnetic field to the single ICP source is applied to the array ICP source, and is found to be effective in terms of etch rate and uniformity.

일정전류 비평행교류브릿지에 의한 전도도측정과 황의 정량 (An Unbalanced A.C. Bridge with High Voltage Source for the Conductometric Determination of Sulfur in Iron Ores)

  • 채명준;최규원
    • 대한화학회지
    • /
    • 제14권4호
    • /
    • pp.327-332
    • /
    • 1970
  • A simple and convenient device for deflection-type direct reading the variations in electrolytic conductance is described and applied to the analysis of sulfur by combustion-$H_2O_2$ oxidation method. The apparatus consisted of a high resistance-ratio bridge in which the other adjacent arms are the differential cells. By adopting unusually high a-c voltage source for the bridge excitation, the a-c method for unbalanced bridge is established, decreased sensitivity owing to reduced bridge factor, 0.01, is overcome and also the absolute sensitivity and linearity are greatly improved. Over 50% variations in impedance of the balanced cell, within 1% deviation from the linearity can be attained with a volt (rms)order of output which was detected directly with VTVM without further amplification. Analysis of the bridge shows that these useful features are natural result of the constant current character of the high source impedance generator and the performance of the device agreed with the theoretical predictions. A standard procedure for the rapid analysis of sulfur using the bridge is also given, the analytical accuracy was approximately 1%. A determination takes not more than 5 minutes.

  • PDF