• 제목/요약/키워드: Source Characteristics

검색결과 6,528건 처리시간 0.036초

새로운 Convergence 방법을 이용한 플래시 메모리의 개서 특성 개선 (New convergence scheme to improve the endurance characteristics in flash memory)

  • 김한기;천종렬;이재기;유종근;박종태
    • 대한전자공학회:학술대회논문집
    • /
    • 대한전자공학회 2000년도 하계종합학술대회 논문집(2)
    • /
    • pp.40-43
    • /
    • 2000
  • The electrons and holes trapped in the tunneling oxide and interface-states generated in the Si/SiO$_2$ interface during program/erase (P/E) operations are known to cause reliability problems which can deteriorate the cell performance and cause the V$_{th}$ window close. This deterioration is caused by the accumulation of electrons and holes trapped in the oxide near the drain and source side after each P/E cycle. we propose three new erase schemes to improve the cell's endurance characteristics: (1)adding a Reverse soft program cycle after the source erase operation, (2)adding a detrapping cycle after the source erase operation, (3)adding a convergence cycle after the source erase operation. (3) is the most effective performance among the three erase schemes have been implemented and shown to significantly reduce the V$_{th}$ window close problem. And we are able to design the reliable periperal circuit of flash memory by using the (3).(3).

  • PDF

LED광원의 자기장 유도전류와 잡음 단자전압의 분석 (EMI Characteristics Analysis of LED Light Source)

  • 황명근;신상욱;조미령;이세현;전상규
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 추계학술대회 논문집
    • /
    • pp.151-155
    • /
    • 2007
  • 본 논문에서는 현재 가장 많이 사용되는 조명용 LED광원에 대한 EMI특성을 측정 분석 분석하였다. LED 광원의 자기장 유도전류와 각각의 인입 전원선에 대한 잡음 단자전압 등을 측정 및 분석하였으며, 향후 LED광원 관련 규격 제안시 참고자료로 활용될 것으로 판단된다.

  • PDF

침수된 전기설비의 누전으로 인한 수중에서의 감전특성에 관한 연구 (A Study on the Characteristics of Electric Shock in Water due to the Leakage of Submerged Electric Facility)

  • 김두현;강동규
    • 한국안전학회지
    • /
    • 제17권3호
    • /
    • pp.61-65
    • /
    • 2002
  • A study on the characteristics of electric shock in fresh water due to the leakage of submerged electric facility is conducted by using a reduced scale model at a scale of 1:10 in laboratory. Electric potential as a function of distance from leakage source, type of the leakage source, magnitude of the source voltage, submerged depth and diameter of a copper rod electrode is measured. On the basis of safety standard, separation for guarantee of safety is determined by the measured potential. Also supposing that body resistance is 500[$\Omega$], the human reaction was estimated by calculating body current for some shock duration. Thus, in this paper, the hazard of the electric shock is assessed by introducing representative safety factors, body voltage and body current due to leakage source.

순시 인텐시티 측정 기법의 개발 및 응용 (Development and Application of Measuring Method of Instantaneous Intensity)

  • 이장우;김영종;안병하;이운섭
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 1997년도 추계학술대회 논문집
    • /
    • pp.560-563
    • /
    • 1997
  • Sound intensity method is well known as a visualization technique of sound field and sound propagation in noise control. Sound intensity is a vector quantity that describes the magnitude and the direction of net flow of acoustic energy at a given position. The current measuring method is expensive and difficult to identify the noise source exactly. In this paper, we have studied the noise source identification and the characteristics of noise source of rotary compressor for air conditioner using complex sound intensity method. The new method for instantaneous sound intensity is also proposed and it is useful for transient state and steady state. The criteria of these states select auto correlation coefficient. The advantage, simplicity and economic attribution of this method are verified by analyzing the characteristics of noise source with instantaneous sound intensity compared to mean sound intensity.

  • PDF

고속 전환특성을 가진 자동부하전환 개폐기의 구동메커니즘의 동적 해석 (Dynamic Analysis of Driving Mechanism for ALTS with High-Speed Transfer Characteristics)

  • 정원선;권병희;안길영;오일성
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2003년도 추계학술대회
    • /
    • pp.1530-1535
    • /
    • 2003
  • The automatic load transfer switch (ALTS) typically automatically transfers electrical loads from a normal electrical power source to an emergency electrical power source upon reduction or loss of normal power source voltage. It can also automatically re-transfer the load to the normal power source when the normal voltage has been restored within acceptable limits. The transfer operation of ALTS is accomplished by a spring-driven linkage mechanism. In this paper we build a dynamic model of driving mechanism for ALTS using ADAMS and checked the characteristics of the transfer operation. Finally we performed a detailed design of the driving mechanism through results of analysis and confirmed it to satisfy design requirements.

  • PDF

순시 인텐시티 측정 기법의 개발 및 응용 (Development and Application of Measuring Method for Instantaneous Intensity)

  • 이장우;안병하
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2003년도 춘계학술대회논문집
    • /
    • pp.960-963
    • /
    • 2003
  • Sound intensity method is well known as a visualization technique of sound field and sound propagation in noise control. Sound intensity is a vector quantity that describes the magnitude and the direction of net flow of acoustic energy at a given position. The current measuring method is expensive and difficult to identify the noise source exactly. In this paper, we have studied the noise source identification and the characteristics of noise source of rotary compressor for air conditioner using complex sound intensity method. The new method for instantaneous sound intensity is also proposed and it is useful for transient state and steady state. The criteria of these state, select auto correlation coefficient. The advantage, simplicity and economic attribution of this method are verified by analyzing the characteristics of noise source with instantaneous sound intensity compared to mean sound intensity.

  • PDF

마이크로폰 어레이를 이용하여 차량 하부에서 발생한 결함의 위치를 찾아내는 방법 (A method to find the position of fault in a moving vehicle using microphone arrays)

  • 김양한;전종훈
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2006년도 추계학술대회 논문집
    • /
    • pp.144-151
    • /
    • 2006
  • Sound generated from a moving vehicle often carries information on the condition of vehicle, for example, whether it has faults or not, where the fault exists. The latter is possible especially by MFAH(moving frame acoustic holography) and beamforming method. MFAH is applicable to the sound source of pure tone or narrow band noise. For the beamforming method, we have to know what kind of wave the sound source radiates, for example, plane wave or spherical wave. That is, whether the above methods are applicable depends on the characteristics of sound source. To apply these methods to the fault detection, we have to know the characteristics of wave from faults. In this research, a machine diagnosis technique based on the above holographic approaches is introduced to find the position of faults. The signal due to faults is modeled based on the fact that the faults radiate impulsive noise, and analyzed in time and frequency domain. The way how MFAH and beamforming method can be used is introduced to find the position of source.

  • PDF

전원분할 커패시터 용량변화에 따른 ZVS-HB형 DC-DC 컨버터의 특성 해석 (A Characteristic Analysis of ZVS-Half Bridge type DC-DC Converter with the Capacity Variation of Source division Capacitor)

  • 오경섭;남승식;김동희
    • 조명전기설비학회논문지
    • /
    • 제15권2호
    • /
    • pp.31-37
    • /
    • 2001
  • 본 논문은 기존의 전원분할 기능만을 하는 전해 커패시터 대신에 ZVS, ZCS와 전원분할 및 공진 기능을 동시에 가지며, 분할비를 이용하면 서로 다른 출력특성을 얻을 수 있는 ZVS-HB형 DC-DC 컨버터를 제안하고 있다. 회로의 해석은 전원분할 커패시터의 분할비에 따른 대부분의 특성들을 무차원화 파라미터를 적용하여 범용성 있게 기술하고 있다. 또, Power-MOSFET를 적용한 실험에서 얻은 실험치와 특성해석에서 얻은 이론치를 비교 하여 특성해석의 정당성을 확인하였다.

  • PDF

슬러지 연소 특성을 통한 신재생에너지의 안전성 연구 (On the Characteristics of Sludge Combustion for Developing Safe and Reusable Energy)

  • 박경진;여재익;윤희철
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2006년도 제33회 KOSCO SYMPOSIUM 논문집
    • /
    • pp.42-45
    • /
    • 2006
  • A new and reusable energy source is water-treatment sludges. There is a significant need for understanding the characteristics of sludge combustion related to improving efficiency and ensuring the safety of this new energy source. Because sludges are composed of solids and gas mixture, the combustion of the mixture may become quite complex. Not only decomposition of conventional organic elements but also dust explosion may be important during the process of converting sludges into a new and safe form of energy. Sludge combustion mainly involves hydrogen, methane, hydro carbons, carbon, and organic particles. Dust explosion during the gasification stage may depend on the surrounding temperature and the composition of gases. The uncertainty in the explosive behavior of energetic source is noted in this work. We study the explosion characteristics of sludge combustion while the reusability of sewage sludges as a new form of energy is also investigated.

  • PDF

경량 및 중량 충격원에 의한 표준 실험동의 진동전달 특성 분석 (Analysis on the Vibration Transmission Characteristics of the Standard Test Building by Using Standard Impact Source)

  • 진필화;김흥식;김도형
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.371-371
    • /
    • 2006
  • The purpose of this study is to provide a fundamental data for efficient and economical reduction method and predict ion method of floor impact noise. In order to get the useful results, the measurement on the vibration transmission characteristics of standard test building with four rooms by using heavy and light-weighed impact source were carried out. In this measurement various conditions such as the change of test structure construction, the pick-up sensor location, the excitation posit ion, and the resilient material types were applied to get the vibration characteristics transmitted from excitation room to adjacent rooms.

  • PDF