• 제목/요약/키워드: Source Characteristics

검색결과 6,570건 처리시간 0.04초

음향 인텐시티를 이용한 하드디스크 드라이브의 소음원 파악 및 음향파워 제어 (Noise Source Identification and Acoustic Radiation Power Reduction of Hard Disk Drive Using Sound Intensity)

  • 강성우;한윤식;황태연;손영;구자춘
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1540-1548
    • /
    • 2000
  • Sound intensity techniques and ODS(Operational Deflection Shape) techniques are applied to identify the acoustic noise source of a hard disk drive and its control system. The sound intensity is used to visualize the noise source locations, and the ODS information to visualize the vibration pattern and to obtain the dynamic characteristics of the noise sources. The measurement systems are customized to accurately measure the sound intensity and ODS distributions of HDD system in space domains as well as frequency domains. The measurement systems for the sound absorption and transmission loss of materials are also used to support the background data for the efficient noise control. Using the visual information of source locations and its dynamic characteristics, the partial noise barrier structure and optimum absorption are designed and its controlled sound power level is proved to be under 3.1 Bel(Idle)/3.3Bel (Seek) which is the lowest level in the disk drive industry.

  • PDF

경계배치법에 의한 근거리 음장 해석 기법 연구; 가중치를 갖는 선배열 음원의 최적 측정점 개수의 결정 (Study on Sound Field Analysis in Near-Field using Boundary Collocation Method; Decision of Optimum Points of Measurement for Line Array Sound Source with Weighting Value)

  • 김원호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 춘계학술대회논문집
    • /
    • pp.1752-1761
    • /
    • 2000
  • This paper describes the far-field estimation using the near-field measurement data. Measurement in far-field region gives us the acoustical characteristics of the source but in general measurement is made in near-field such as acoustic water tank or anechoic chamber, so far-field acoustical characteristics of the source should be predicted from near-field data. In this case, the number of measurement points in the near field which relates to the accuracy of the predicted field and the amount of data processing, should be optimized. Existing papers say that measurement points is proportional to kL and depends on geometry and directivity of the source. But they do not give us any definite criterion for the required number of measurement points. Boundary Collocation Method which is one of the far-field prediction methods, is analyzed based on Helmholtz integral equation and Green function and it has been found that the number of measurement points is optimized as 0.54kL which is about one half of the existing results.

  • PDF

간호대학생의 스트레스 수준, 근원 및 대처방식 (Nursing Students' Stress Level, Source and Coping)

  • 주민선;이영란;김선희
    • 가정∙방문간호학회지
    • /
    • 제19권2호
    • /
    • pp.195-203
    • /
    • 2012
  • Purpose: This study is conducted to investigate the stress level, stress source and stress coping of nursing students in college. Methods: This study was a cross sectional survey and the data was collected from 341 nursing students by means of self-reported questionnaires from April 2 to May 31, 2012. Collected data were analyzed on SPSS win 18.0. Results: The nursing students experienced moderate levels of stress. The source of stress for students came from 'one's own self'. The most common stress coping used by students was 'make a wish'. There were significant differences in the source of stress and the stress coping according to the nursing students' year of school and other general characteristics, such as motivation of entrance and satisfaction in school life. Conclusion: These results suggest that it is important to develop stress management program and strategies based on nursing students' individual characteristics and sources of stress.

  • PDF

낙동강 상류유역의 지역별 비점오염부하 특성 (Regional Characteristics of Nonpoint Source Pollutant Loads in the Upstream Watersheds of Nakdong River)

  • 최경숙;손성호
    • 한국관개배수논문집
    • /
    • 제13권2호
    • /
    • pp.283-292
    • /
    • 2006
  • The characteristics of nonpoint source pollutant loads in upstream of Nakdong River were studied through analysis of pollutant loads of 10 sub-watersheds divided based on administrative district. The discharge and pollutant concentration of each sub-watershed were collected from Nakdong-River Water Research Institute and Daegu Regional Environmental office, respectively. Pollution items analysed in this study were BOD, T-N and T-P. The delivery loads of the nonpoint source pollutions of each sub-watershed were calculated after analysing the concentration of the pollution of each site. Several points were found from the results. Firstly, in general, city areas including Sangju, Andong showed higher degree of nonpoint pollution than country areas including Cheongsong, Yeongyang. The sub-watersheds located upstream side, such as Yeongju, Bonghwa, Necessarily show better water quality than the sub-watersheds located downstream side, such as Mungyeong, Uiseong. This result indicates that a given pollution condition within the watershed can be more sensitive than location factor to the level of water quality. Secondly, the delivery load and area of watershed were not necessarily correlated in the sense of water quality, while the discharge was shown to be highly correlated to the delively load of pollution. Lastly, sewage and waste caused from population and livestock, as well as landuse factor, were found to significantly contribute to the water pollution. Alternative solutions for controlling pollution source, therefore, should be provided to meet target levels of water quality in these regions.

  • PDF

복소음향인텐시티법을 이용한 HVAC의 소음원 검출 (Identification of Noise Source of the HVAC Using Complex Acoustic Intensity Method)

  • 양정직;이동주
    • 한국소음진동공학회논문집
    • /
    • 제20권11호
    • /
    • pp.1089-1096
    • /
    • 2010
  • The relation between the vibration induced from machinery and the radiated sound is complicated. Acoustic intensity method is widely used to obtain the accuracy of noise measurement and noise identification. In this study, as groundwork, the complex acoustic intensity method is performed to identify noise source and transmission path on different free space point source fields. As an industrial application, the complex acoustic intensity method is applied to HVAC to identify sound radiation characteristics in the near field. Experimental complex acoustic intensity method was applied to HVAC, it is possible to identify noise sources in complicated sound field characteristics which noise sources are related with each other, and certificate the validity of complex acoustic intensity. Especially, it can be seen that complex acoustic intensity method using both of active and reactive intensity is vital in devising a strategy for identification of noise. Also, the vector flow of acoustic intensity was investigated to identify sound intensity distributions and energy flow in the near field of HVAC.

Development of Nonthermal Bioplasma Source Applicable to Human Liquid Fluids

  • Min, Boo-Ki;Oh, Hyun-Joo;Song, Ki-Baek;Uhm, Han-Sup;Kang, Seung-Oun;Choi, Eun-Ha
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2011년도 제41회 하계 정기 학술대회 초록집
    • /
    • pp.327-327
    • /
    • 2011
  • A nonthermal bioplasma source was developed for application to human liquid fluids by making use of nano-size tungsten tips. Characteristics of the plasma source are investigated. Here we have used the AC voltage system. The bioplasma source generated by a tungsten tip with quartz tube and ground electrode is a low-temperature plasma without making any noticeable damage to cells at a low power operation. The breakdown voltage and current signals are measured by high voltage probe (Tektronix P6015A) and current probe (P6021). Variation of breakdown temperature near the tip electrode is larger than that in the neighborhood of ground electrode. Bubble formation during discharge has been recorded and investigated by using the high speed camera. The existence and behavior of hydroxyl and superoxide radicals are detected and measured by spectrometers. The electrical and optical properties of breakdown characteristics are also investigated.

  • PDF

오대산지진(2007/01/20)의 지진원 특성에 관한 연구 (A Study for Earthquake Parameter of Odaesan Earthquake)

  • 김준경
    • 지질공학
    • /
    • 제17권4호
    • /
    • pp.673-680
    • /
    • 2007
  • 2007년 1월 20일 발생한 오대산지진과 관련된 지진원 상수(지진원기구, 진원깊이, 규모, 지진원 특성 등)를 지진모멘트텐서 방법을 이용하여 분석하였다. 3개의 지각속도 모델에 의한 각각의 지각반응을 분석을 위한 그린함수로 이용하였다. 분석된 6개의 지진모멘트텐서 성분을 조합한 결과 오대산지진은 거의 북북동 방향의 주향을 가진 주향단층의 운동에 의해 발생된 것으로 해석된다. 진원깊이는 약 11 km의 값을 가지고 있으며 6개의 지진모멘트 성분을 분석한 결과 CLVD 성분이 약 7%의 값을 가지고 있어 순수 단층면위의 미끄러짐 현상에 의해 발생된 것으로 해석되었다. 지진원기구의 주향이 오대산 단층의 주향과 일치하고 있고, 또한 진앙도 오대산 단층의 지표 연장선과 밀접한 관계를 보여주고 있으므로 오대산 단층이 지진유발 단층인 것으로 해석된다.

SVPWM 방식 마이크로소스로 구성된 마이크로그리드 모델링 및 해석 (Modeling and Analysis of the Micro-Grid with SVPWM Micro-Sources)

  • 손광명;이계병;김영섭
    • 조명전기설비학회논문지
    • /
    • 제20권3호
    • /
    • pp.12-19
    • /
    • 2006
  • 마이크로소스는 1[kW]${\sim}$수[MW] 사이의 전력을 공급하고, 기존의 대규모 발전설비보다 높은 신뢰도와 에너지 효율을 가지는 고품질의 전력을 공급할 수 있다. 본 논문에서는 마이크로소스의 스위칭레벨 모델을 개발하였으며, 다수의 마이크로소스가 전력시스템과 연계되어 마이크로그리드를 형성할 경우의 특성에 대하여 연구하였다. 마이크로소스는 인버터의 효율을 극대화 할 수 있도록 공간벡터 펄스폭변조(Space Vector PWM, SVPWM) 기법을 채용하였으며, 마이크로소스의 제어시스템 파라미터 특성 및 마이크로소스 상호작용에 관하여 연구하였다. 마이크로소스는 PSCAD/EMTDC를 이용하여 구현하였으며 이를 이용해 마이크로그리드를 구성하여 시뮬레이션하였다. 사례 연구를 통하여 제안된 모델의 효용성을 확인하였다.

덕트 내 음원 특성 측정을 위한 다중부하법의 부하 선택에 관한 연구 (On the selection of loads in the multi-load method for measuring in-duct source characteristics)

  • 장승호;이정권
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.384-388
    • /
    • 2000
  • One-port acoustic characteristics of an in-duct source can be measured by the multi-load method using an overdetermined set of open pipes with different lengths as applied loads. The input data. viz. load pressure and load impedance, are usually contaminated by measurement error in the actual measurements, which result in errors in the calculated source parameters. In this paper, the effects of the errors in the input data on the results have been studied numerically, varying the number of loads and their impedances in order to determine what combination of the loads will yield the best result. An error analysis is applied to each case of possible loads, which consist of open pipes. It is noted that, frequently, only a set of open pipes is used when applying the multi-load method to the intake or exhaust sides of internal combustion engines. A set of pipe lengths which cause the calculated results to be least sensitive to the input data error can be found when using open pipe loads. The present work is intended to produce guidelines for preparing an appropriate load set in order to obtain accurate source properties of fluid machines.

  • PDF

REDUCED DIFFERENTIAL TRANSFORM FOR THERMAL STRESS ANALYSIS UNDER 2-D HYPERBOLIC HEAT CONDUCTION MODEL WITH LASER HEAT SOURCE

  • SUTAR, CHANDRASHEKHAR S.;CHAUDHARI, KAMINI K.
    • Journal of the Korean Society for Industrial and Applied Mathematics
    • /
    • 제25권2호
    • /
    • pp.54-65
    • /
    • 2021
  • In this study, a two-dimensional thermoelastic problem under hyperbolic heat conduction theory with an internal heat source is considered. The general solution for the temperature field, stress components and displacement field are obtained using the reduced differential transform method. The stress and displacement components are obtained using the thermal stress function in the reduced differential transform domain. All the solutions are obtained in the form of power series. The special case with a time-dependent laser heat source has been considered. The problem is considered for homogeneous material with finite rectangular cross-section heated with a non-Gaussian temporal profile. The effect of the heat source on all the characteristics of a material is discussed numerically and graphically for magnesium material taking a pulse duration of 0.2 ps. This study provides a powerful tool for finding the solution to the thermoelastic problem with less computational work as compared to other methods. The result obtained in the study may be useful for the investigation of thermal characteristics in engineering and industrial applications.