• 제목/요약/키워드: Sound transmission class(STC)

검색결과 5건 처리시간 0.02초

건식 경량칸막이 벽체의 차음성능 개선을 위한 실험적 연구 (An Experimental Study on Light- Weight Drywall for Improvement of Sound Insulation Performance)

  • 김태희;신일섭;조창근;송문수;손장열
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.1083-1087
    • /
    • 2001
  • The purpose of this study is to obtain the basic data of existing light-weight Drywall through the evaluation and analysis of the light-weight drywall in reverberation chamber and to improve sound insulation performance of drywalls. Sound transmission loss of the total 11 types were analyzed in each frequency a-third octave band and evaluated sound insulation performance for each frequency. From data by analysis and calculation, STC value plotted on STC contour. We found that the improved light-weight drywall specimens ⓑ, ⓒ and ⓖ were satisfied with the domestic standard of sound transmission loss.

  • PDF

고밀도 암면 다중판의 차음성능 (Sound Insulation performance of multi-layered panels with high density mineral wool)

  • 강현주;김재승;김현실;김봉기;김상렬
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.421-424
    • /
    • 2000
  • This paper investigates the characteristics of analytical models in prediction of sound transmission loss for the multi-layered panels with high density mineral wools. The results show that the sandwich model is more adequate to account for sound insulation performance of those panels than the poro-elastic model. In order to improve STC(Sound Transmission Class), the effect of fiber directions of mineral wools is examined, analytically and experimentally. From the comparison of the measurements with the predictions, it is evident that the vertical fiber directions of mineral wools enhance STC value up to 6 dB, compared to that of the horizontal fiber directions.

  • PDF

공동주택의 현관문 차음성능 개선을 위한 연구 (Improvement of Sound Transmission Class in the Front Door of Apartment)

  • 이병권;배상환;홍천화;송만수;정문호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.93-96
    • /
    • 2004
  • In the case of the front door of the apartment, which functions as an entrance, the study about noise has been less active than corridor type plane in the past, since stair room type plane was generalized. Hence, this study shows the survey about residents' thoughts of noise transmission through the front door, and after researching sound insulation of the present apartments, we figured out what the problem is. Moreover, we did an efficiency test as developing the front door, which increases sound insulation. As a result, it turned out that residents think that the noise transmission through the front door is as serious as floor impact noise, and also, the efficiency of the front door is as poor as STC 22-30. Therefore, in the developed front door, we should improve the efficiency to the level of STCSS. It will be a good way preparing for a demand of residents.

  • PDF

현장실험을 통한 학교교실의 벽체 차음성능 및 측로전달소음 조사 (Investigation of the sound insulation performance of walls and flanking noises in classrooms using field measurements)

  • 류다정;박찬재;한찬훈
    • 한국음향학회지
    • /
    • 제36권5호
    • /
    • pp.329-337
    • /
    • 2017
  • 미국과 영국에서는 교실의 적정한 음환경을 제공하기 위하여 잔향시간 및 배경소음에 대한 기준이 수립되어 있다. 또한 이를 실현하기 위한 건축계획방법 및 실내마감재 적용에 대한 가이드라인을 제시하고 있다. 그러나 대한민국의 경우 학교 교실의 배경소음 기준을 만족하기 위한 가이드라인이 부족할 뿐만 아니라 이에 기초가 되는 교실 벽체의 차음성능에 대한 실태조사가 부족한 실정이다. 본 연구에서는 학교 교실의 실내외 소음에 대한 차음성능을 조사하기 위하여 대한민국 청주시 소재 중학교 2개소의 외부벽체와 실간벽체의 구조를 조사하였다. 실내외 벽체의 차음성능 및 측로전달소음을 비교분석하기 위하여 투과손실, 가중 표준화 음압레벨차, 음향 감쇠 계수, 신호대잡음비 등을 측정하였다. 연구결과 실간벽체의 경우 건식벽으로 건립된 학교의 차음성능이 습식벽보다 높게 나타났으며, 특히 중고파수대역에서 높은 차음성능을 나타내었다. 외부벽체의 경우 각 학교 별로 차음성능을 비교하였을 때 단창을 이중으로 배치한 학교보다 복층유리를 사용한 학교의 성능이 더 높은 것으로 나타났다. 또한 측로전달소음의 경우 창문을 모두 개방하거나 복도 측 창문과 문을 연 경우 기준을 초과하는 것으로 나타나 내부 소음에 의해 학생이 음성전달에 방해를 받을 수 있음을 알 수 있었다.

가설방음벽의 운영방안 및 설치기준에 관한 연구 (The study on the management method and installation guide of temporary noise barrier)

  • 윤제원;김영찬;강희만;장태순;이기정
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.372-375
    • /
    • 2006
  • 건설 공사장에서 발생하는 건설장비의 소음을 저감하여 공사장 인근 지역의 생활환경에 미치는 소음영향을 최소화할 수 있도록 건설업체에서는 최대한의 노력으로 가설방음벽을 설치 운영하고 있으나, 설치된 가설방음벽의 효과분석 및 운영방법에 대한 검토가 부족하여 효율적인 소음저감대책으로서의 가설방음벽 운영이 어려운 실정이다. 따라서, 본 연구에서는 가설방음벽의 기초데이터의 확보와 소음해석을 통한 효율적인 운영방안을 제시하며, 설치기준에 관한 방안을 제시하고자 한다.

  • PDF