• 제목/요약/키워드: Sound pressure Level

검색결과 690건 처리시간 0.038초

Shroud 형상에 대한 해석적 연구 및 '프로벨러 홴' 소개 (Computational Study of the Shr oud Shape & the ProBeller Fan)

  • 한재오;유승훈;모진용
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2008년도 춘계학술대회논문집
    • /
    • pp.638-641
    • /
    • 2008
  • Computational investigation was conducted to study the effects of the shape parameter of shroud on the performance of the outdoor unit of an air-conditioners. For this study the Design of Experiment(4-factor 3-level) was created and the an automatic program was composed using VBA to reduce the load of pre-process for CFD. The estimated mathematical equation was produced from this analysis and it was found that the gap between fan and shroud affects more heavily than the other parameters. As a result, the composition of the best parameters was verified that its flow rate was increased by 10 percents and sound pressure level was reduced by 1.2 dBA compare with the worst. And finally, a kind of Propeller fan with blades which were attached to the shroud, so-called 'ProBeller Fan' was introduced in this study.

  • PDF

대형석탄화력발전용 보일러 관군의 Anti-Noise Baffle 설치에 따른 음향공진 (Acoustic resonance by Inserting Anti-noise Baffle in the Tube Bank of Boiler of a Large Fossil Power Plant)

  • 방경보;김철홍
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 추계학술대회논문집
    • /
    • pp.178-183
    • /
    • 2004
  • This paper presents phenomena of vibration and noise due to acoustic resonance in tube bank of a large fossil power plant. The phenomena of acoustic resonance may arise when the vortex shedding frequency coincides with the acoustic natural frequency. In this system dominant frequency of vibration and noise was 37.5Hz. The $3^{rd}$ acoustic natural frequency calculated was 37.2 Hz. When the difference of vortex shedding frequency and acoustic natural frequency is within ${\pm}20%$, acoustic resonance could occur. If system is the state of acoustic resonance, vibration and noise become large. In order to prevent acoustic resonance, anti-noise baffle should be installed in the tube bank. In the case of installing baffle, we should consider the number of baffle and the effect of acoustic mode due to baffle extension length. To do this, we did acoustic mode analysis. After installing anti-noise baffle, acoustic resonance was disappeared and vibration magnitude and noise level was reduced dramatically.

  • PDF

부유식 석유생산.저장.하역선박의 소음해석 (A Noise Prediction of Floating, Production, Storage and Offloading(FPSO))

  • 김영현;김동해
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.307-310
    • /
    • 2000
  • Recently, the demand for the Floating, Production Storage, and Offloading facility(FPSO) which has some economic and technical advantages, has increased in offshore oil production areas. The basic characteristics of a 343,000 DWT class FPSO which is being built in Hyundai Heavy Industries and shall be installed in offshore Angola, is almost same as that of oil carriers. However, she do not have self-propulsion system, but has additional facilities for oil production and positioning system. Main noise source contributing to the cabin noise of the accommodation, are classified into the machine in the engine room and the deckhouse, HVAC system, and the topside equipments. In general, the noise regulation for the offshore structure is much severer than that of the common commercial ships and the maximum acceptable sound pressure level of cabins is specified in 45dB(A). This paper describes the procedure of noise analysis along with its results. Noise analysis has been carried out for the case of emergency diesel generator running condition and the case of normal production condition and the results has been compared with the measurement results of the first case. Based on the results, proper countermeasures to reduce excessive noise level has been applied considering the characteristics of sources and receiver spaces and can be satisfied the specifications at all spaces.

  • PDF

75MW 급 발전용 보일러 관군에서의 음향공진에 의한 진동/소음 사례연구 (A Case Study on the vibration and noise by acoustic resonance in the tube bank of a boiler of 75MW power plant)

  • 김철홍;방경보;주영호;변형현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2000년도 추계학술대회논문집
    • /
    • pp.150-155
    • /
    • 2000
  • This paper presents phenomena of vibration and noise due to acoustic resonance in tube bank of a power plant. Acoustic resonance is may arise when the vortex shedding frequency coincides with the acoustic natural frequency. At the resonance, the value of vibration in this system was 595 ${\mu}m$, p-p and the sound pressure level was maximum 103 dBA. And the resonance frequency was found to be 35 Hz. When the difference of vortex shedding frequency and acoustic natural frequency is within ${\pm}20%$, acoustic resonance is possible. In this system, the difference of these frequencies was 1.8%. We can evaluate the possibility of acoustic resonance by using damping parameter. We did eliminate acoustic resonance by installing baffle in tube bank. After installing baffle, the level of vibration and noise was reduced dramatically.

  • PDF

음향도구 착용 근로자의 소음노출 실태에 관한 연구 (Research on the characteristics of noise exposure on worker wearing acoustic devices)

  • 김갑배;유계묵;이인섭;정광재
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2011년도 춘계학술대회 논문집
    • /
    • pp.808-813
    • /
    • 2011
  • There are hundreds of thousands call center workers wearing acoustic device. However, researches and noise exposure measurements on the noise transmitted from acoustic devices have seldom been performed due to the difficulty of measurement and to the absence of the measuring method in Korea. The aim of this study is to set up management measures to protect hearing loss on the call operator by acquiring measurement data of noise transmitted from the headset Noise exposure measurements of 17 operators were performed in 7 call centers and Head and Torso Simulator method in compliance with the ISO Standard 11904-2 was used for the measurement of noise transmitted from the headset Sound pressure levels(SPL) transmitted from the headset were 73.2~86 dB(A). The operator exposed to the highest SPL set up his volume control at 9 which was the highest volume level. The volume control level, adjustable from 1 to 9, could be identified 12 out of 17 operators and the range of volume levels was 4.5~9. As a result of Pearson Correlation Analysis, the correlation between volume level and SPL transmitted from the headset showed high relation as significance at the 0.672 level(p<0.05). To protect hearing loss of call center operators, it is more practical and effective measure to limit the volume level below the noise exposure level, i.e. 85 dB(A), rather than to carry out noise monitoring considering cost-effective aspect.

  • PDF

음향도구 착용 근로자의 소음노출 실태에 관한 연구 (Research on the Characteristics and Measures of Noise Exposure on Worker Wearing Acoustic Devices)

  • 김갑배;유계묵;이인섭;정광재
    • 한국소음진동공학회논문집
    • /
    • 제21권7호
    • /
    • pp.615-621
    • /
    • 2011
  • There are hundreds of thousands call center workers wearing acoustic device. However, researches and noise exposure measurements on the noise transmitted from acoustic devices have seldom been performed due to the difficulty of measurement and to the absence of the measuring method in Korea. The aim of this study is to set up management measures to protect hearing loss on the call operator by acquiring measurement data of noise transmitted from the headset. Noise exposure measurements of 17 operators were performed in 7 call centers and head and Torso simulator method in compliance with the ISO standard 11904-2 was used for the measurement of noise transmitted from the headset. Sound pressure levels(SPL) transmitted from the headset were 73.2~86 dB(A). The operator exposed to the highest SPL set up his volume control at 9 which was the highest volume level. The volume control level, adjustable from 1 to 9, could be identified 12 out of 17 operators and the range of volume levels was 4.5~9. As a result of pearson correlation analysis, the correlation between volume level and SPL transmitted from the headset showed high relation as significance at the 0.672 level(p<0.05). To protect hearing loss of call center operators, it is more practical and effective measure to limit the volume level below the noise exposure level, i.e. 85 dB(A), rather than to carry out noise monitoring considering cost-effective aspect.

군용 항공기 이륙소음이 청력, 혈압, 스트레스 및 주관적 인지도에 미치는 영향 (The effects of aircraft noise on the hearing loss, blood pressure and response to psychological stress)

  • 한상환;조수헌;고경심;권호장;하미나;주영수;신명희
    • Journal of Preventive Medicine and Public Health
    • /
    • 제30권2호
    • /
    • pp.356-368
    • /
    • 1997
  • In effort to determine whether aircraft noise can have health effects such as hearing loss, hypertension and psychological stress, a total of 111 male professors and administrative officers working a college near a military airport in Korea(exposed group) and a total of 168 males and 112 females matched by age groups(control groups) were analyzed. Personal noise exposure and indoor and outdoor sound level of jet aircraft noise were measured at the exposed are3. And pure tone, air conduction test and measurement of blood pressure were given to the exposed(males) and matched control groups (males and females). BEPSI(Brief Encounter Psychological Instrument) and psychological response to aircraft noise were examined for the exposed group. The noise dosimetry results revealed time-weighted averages(TWAs) that ranged from 61 to 68 dBA. However the levels encountered during taking off jet airplanes reached 126 dBA for two half minutes time period. Th, audiometric, test showed that mean values of HTL(hearing threshold level) in exposed group at every frequency(500, 1,000, 2,000, 4,000, and 8,000 Hz were much lower than them of male and female control groups. And in old age groups, interaction of age and noise was observed at 8,000 Hz in both ears(p<0.05). Conclusively, aircraft noise does not appear to induce hearing loss directly in high frequency, but may decreased hearing threshold level by interaction of aging process and noise exposure. However, difference of mean values of exposed and control groups on blood pressure was not significantly. In psychological test, annoyance was the most severe psychological response to noise in exposed group, but mean value of BEPSI was not correlated with job duration in exposed group.

  • PDF

자동차 시트 쿨링용 고성능·저소음 컴팩트 원심팬 개발 (Development of high performance and low noise compact centrifugal fan for cooling automotive seats)

  • 김재현;유서윤;정철웅;장동혁;안민기
    • 한국음향학회지
    • /
    • 제37권6호
    • /
    • pp.396-403
    • /
    • 2018
  • 본 논문에서는 쾌적한 운전 환경을 제공하기 위해 자동차 시트를 냉각시키기 위한 고성능 및 저소음 원심팬을 개발하였다. 먼저 팬 성능 테스터 및 전산유체역학(Computational Fluid Dynamics, CFD) 시뮬레이션을 이용하여 기존 팬 장치의 유동 특성을 분석하였다. 예측한 유동장 분석을 통하여 팬 허브 팁 근처의 와류 및 팬 허브 상단의 정체된 유동 현상이 관측되었다. 이러한 와류 및 정체 유동을 줄이기 위해 두 가지 설계 요소를 고안하였다. 첫째, 팬 날개와 팬 하우징 최소 간극(cut-off)를 증가시켜 난류강도를 줄이고 그 결과로 전체적인 음압 레벨을 줄이고자 하였다. 둘째, 허브 형상은 정체 유동을 줄이기 위해 형상을 변경하였다. 제안된 설계의 타당성을 수치해석을 통해 확인하였다. 수치해석결과를 바탕으로 프로토타입을 제작하고 팬 테스터에서 측정한 성능 곡선(P-Q curve)과 반무향실에서 측정한 음압 레벨의 분석을 통해서 유동과 소음 성능의 향상을 확인하였다.

FxLMS 알고리듬 기법을 이용한 식기 세척기의 펌프 소음 능동 제어 (Active control of pump noise of dishwashers using FxLMS algorithm)

  • 탁언수;오한음;홍진숙;정의봉
    • 한국음향학회지
    • /
    • 제40권1호
    • /
    • pp.46-54
    • /
    • 2021
  • 본 논문에서는 가정용 식기세척기의 저주파 대역 방사 소음 저감을 위하여 능동 소음 제어를 수행하였다. 먼저 식기세척기의 소음 환경 분석을 통해 펌프 소음이 저주파 대역 방사 소음에 가장 크게 기여하고 있음을 확인하였고 이를 고려하여 참조 신호를 선정하였다. 참조 신호는 음향피드백을 방지하기 위해 가속도계를 이용하여 펌프 몸체에 부착하여 획득하였다. 오차 신호 센서는 식기세척기 전방 1 m, 높이 0.5 m에 위치한 마이크로폰으로 선정하였다. 다음으로 제어기 설계를 위해 식기세척기의 작동 회전수 2,500 rpm, 2,600 rpm, 2,800 rpm에 대하여 오차 신호와 참조 신호를 측정하고, 2차 경로 전달함수를 측정하였다. 그리고 설계된 제어기를 Digital Signal Processor(DSP) 장비에 탑재 시켜 제어 성능을 시험으로 확인하였다. 시험 결과 펌프 작동 주파수의 7차 배수 성분에서는 회전수 별로 1.93 dB, 4.43 dB, 5.15 dB 만큼 줄었고 12차 배수 성분에서는 회전수 별로 6.67 dB, 2.34 dB, 4.28 dB 만큼 줄었다. 그리고 overall Sound Pressure Level(SPL)은 회전수별로 0.84 dB, 2.58 dB, 1.48 dB 만큼 줄었다.

휴게음식점 주방의 환경위생상태에 관한 조사연구 - 계절별 변화를 중심으로 - (A Study on the Sanitary Condition of Kitchens in Food Court/Cafeterias - An Observation on Seasonal Variations)

  • 김종규;박정영;김중순
    • 한국환경보건학회지
    • /
    • 제38권2호
    • /
    • pp.118-127
    • /
    • 2012
  • Objectives: This study was undertaken to assess the sanitary conditions in the kitchens of food court/cafeterias and determine seasonal variations. Methods: We measured environmental factors (air temperature, relative humidity, illumination intensity, noise level), and dropping airborne microbes (bacteria and fungi) in the kitchens of eight food court/cafeterias in four seasons (January, April, July, and October). Air temperature and relative humidity were measured with in/out thermo-hygrometers at 1.2-1.5 m above floor level. Illuminance measurement was performed through the multiple point method of Korean Standards (KS). Noise level was measured by the standard methods for the examination of environmental pollution (noise and vibration) of Korea. The estimation of dropping airborne bacteria and fungi was performed through use of Koch's method. Results: The highest kitchen air temperature was in July, and the lowest in January. The average temperature surpassed $21^{\circ}C$ throughout the seasons, suggesting a higher temperature than required for the safe handling of food. Humidity in all the kitchens was measured in the range of 50-60%. Half of the kitchens showed illumination intensities below 300 Lux in April. It was found that the sound pressure level of noise in almost all of the kitchens was higher than 85 dB (A). The highest levels of dropping airborne bacteria and fungi were noted in July. The numbers of airborne bacteria were higher than those of fungi. The levels of dropping airborne bacteria and fungi were affected by air temperature, relative humidity, season, and place. Conclusions: This study indicates that the kitchen environments were unqualified to supply safe food. The hygiene level of the kitchens should be improved.