• Title/Summary/Keyword: Sound levels

Search Result 520, Processing Time 0.032 seconds

Consideration on Rating Method for Heavy Impact Sound Taking Account of the Characteristics of Floor Vibration and Impact Sources (바닥 진동 거동 및 충격원 특성을 고려한 바닥 중량 충격음 평가방법 고찰)

  • Lee, Min-Jung;Choi, Hyun-Ki
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.4
    • /
    • pp.69-79
    • /
    • 2017
  • The purpose of this study is to reconsider the rating method for the floor impact sound insulation performance in current criterion. Although there are some arguments about proper standard heavy impact source with reproducibility of actual impact source in residence building, bang machine is adopted as the only standard heavy impact source in domestic criterion. To inspect the rating methods of evaluation criteria, this study conducted vibration test for both of standard heavy impact sources and actual impact sources. Using the test results, the floor impact sound insulation performance levels were assessed by each of several criteria. In addition, low frequency noise beyond current criteria was evaluated. Consequently, the floor impact sound levels have different performance levels according to adopted criteria, and measured floor impact sounds are bound to annoy the neighbors in the low frequency range. Current criteria does not consider the spectrum characteristics of floor impact sound according to impact sources and low frequency noise. This may cause the difference between the floor impact sound insulation performance level and human perception. Thus current criterion needs to be complemented to reflect the spectrum characteristics of floor impact sound levels according to impact sources and sound pressure levels in low frequency range.

Experimental study on the sound attenuation of the fire alarm sounder system in apartment buildings (공동주택 화재경보 발생음 특성에 관한 실험연구)

  • Lee, Min-Joo;Kang, Hee-Hyuk;Kwon, Bong-Suk;Kim, Myung-Jun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.05a
    • /
    • pp.1162-1168
    • /
    • 2007
  • In many fire emergencies, the audible fire alarm signals are very important to save the occupant's life. But as the sound insulation of building elements has been improved, it is more difficult for occupant to recognize the fire alarm signals when the fire alarm worked. This is the study to show the sound attenuation of the fire alarm sounder system in apartment buildings. We measured and analyzed the sound attenuation level in 17 units, and the results were compared with the minimum sound level at sleeping area by NFPA(National Fire Protection Association) 72. When only the fire alarm worked in stair hall, the sound levels in bedroom were in the range of $30.6{\sim}42.8dB(A)$ and the differences between sound level and ambient sound level in bedrooms were in the range of $7.1{\sim}13.8dB(A)$. And when the emergency broadcasting device in the livingroom and the fire alarm worked simultaneously, the sound levels in bedrooms were in the range of $54.2{\sim}63.0dBA$. Finally, it was showed that the fire alarm sounder system didn't give a sufficient sound level in bedroom to awake out of sleep.

  • PDF

Prediction and Reduction of Alarm Sound Propagated through Elevator Shaft (엘리베이터 샤프트를 통한 경보음 전달 예측과 개선)

  • Jeong, Jeong-Ho
    • Fire Science and Engineering
    • /
    • v.33 no.4
    • /
    • pp.89-96
    • /
    • 2019
  • In this study, alarm sound generated as a priority alert system propagation through an elevator shaft in apartment buildings were simulated using room acoustic simulation software. The simulations were conducted on three kinds of elevator hall plan with a different number of elevators and placement. First, the elevator shaft without sound absorption material was simulated as a condition of the present. When the distance from the alarm sound generating floor became farther, alarm sound level was decreased. However, the alarm sound level three-floor distance was about 54 dB(A)~56 dB(A) which were louder than a background sound level of typical apartment buildings. Sound absorption material placement proposed by previous studies were simulated and the alarm sound levels were decreased about 12 dB~16 dB. These levels were similar or lower than the background level of apartment buildings. From these results, it can be concluded that placing sound absorption material on the surface of the elevator shaft wall can be one of the methods to control the alarm sound as regulated in NFSC.

A Study on Sound Radiation from Isofropic Plates Stiffened by Symmetrical Reinforced Beams (대칭형 보에 의해 보강된 등방성 평판의 음향방사에 관한 연구)

  • 김택현
    • Journal of the Korean Society of Manufacturing Technology Engineers
    • /
    • v.7 no.1
    • /
    • pp.41-50
    • /
    • 1998
  • The detemination of sound pressure radiated from peoriodic plate structures is fundamental in the estimation of noise levels in aircraft fuselages and ship hull structures. As a robust approach to this problem, here a very general and comprehensive analytical model for predicting the sound radiated by a vibrating plate stiffened by periodically spaced orthogonal symmetric beams subjected to a sinusoidally time varying point load is developed. The plate is assumed to be infinite in extent, and the beams are considered to exert both line force and moment reactions on it. Structural damping is included in both plate and beam materials. A space harmonic series representation of the spatial variables is used in conjunction with the Fourier transform to find the sound pressure in terms of harmonic coefficients. From this theoretical model. the sound pressure levels on axis in a semi-infinite fluid (water) bounded by the plate with the variation in the locations of an external time harmonic point force on the plate can be calculated efficiently using three numerical tools such as the Gauss-Jordan method, the LU decomposition method and the IMSL numerical package.

  • PDF

A Study on BSR Noise and Sound Quality Property for Vehicle Interior Module (자동차 인테리어 모듈의 BSR 소음과 음질 특성 연구)

  • Shin, Su-Hyun;Cheong, Cheol-Ung;Jung, Sung-Soo;Kang, Dae-Hwan
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.6
    • /
    • pp.550-555
    • /
    • 2012
  • Among the various elements affecting a customer's evaluation of automobile quality, buzz, squeak and rattle(BSR) have been considered to be major factors. In most vehicle manufacturers, the BSR problems are solved by find-fix method with the vehicle road test, mainly due to various excitation sources, complex generation mechanism and subjective response. To systematically tackle the BSR problems in early stage of the vehicle development cycle, these difficulties should be resolved. The aim of the present paper is to characterize the sound quality property of BSR noise that can be used to assess the subjective responses to BSR. The four sound metrics from Zwicker's sound quality parameter are computed for the signals recorded for eight BSR noise source regions localized by using the acoustic-field visualized results. Then, the jury test of BSR noise are performed. On the basis of the computed sound metrics and jury test result is evaluated to represent the harshness of BSR noise. It is expected that the developed BSR measuring system and sound quality properties can be used to reduce the automotive interior BSR noise in terms of subjective levels as well as objective levels.

The Effect of Adaptation to Sound Intensity on the Neural Metabolism in Auditory Pathway: Small Animal PET Study (소동물 [F-18]FDG 양전자단층촬영 기법을 이용한 청각신경에서의 소리크기에 대한 적응효과 연구)

  • Jang, Dong-Pyo
    • Journal of Biomedical Engineering Research
    • /
    • v.32 no.1
    • /
    • pp.55-60
    • /
    • 2011
  • Although sound intensity is considered as one of important factors in auditory processing, its neural mechanism in auditory neurons with limited dynamic range of firing rates is still unclear. In this study, we examined the effect of sound intensity adaptation on the change of glucose metabolism in a rat brain using [F-18] micro positron emission tomography (PET) neuroimaging technique. In the experiment, broadband white noise sound was given for 30 minutes after the [F-18]FDG injection in order to explore the functional adaptation of rat brain into the sound intensity levels. Nine rats were scanned with four different sound intensity levels: 40 dB, 60 dB, 80 dB, 100 dB sound pressure level (SPL) for four weeks. When glucose uptake during the adaptation of a high intensity sound level (100 dB SPL) was compared with that during adaptation to a low intensity level (40 dB SPL) in the experiment, the former induced a greater uptake at bilateral cochlear nucleus, superior olivary complexes and inferior colliculi in the auditory pathway. Expectedly, the metabolic activity in those areas linearly increased as the sound intensity level increased. In contrast, significant decrease interestingly occurred in the bilateral auditory cortices: The activities of auditory cortex proportionally decreased with higher sound intensities. It may reflect that the auditory cortex actively down-regulates neural activities when the sound gets louder.

A Study on the Noise Produced by Unsteady Exhaust Efflux of Engine (기관의 비정상 배기배출에 의해 생성되는 소음에 관한 연구)

  • 이민호;박명규
    • Journal of the Korean Society of Safety
    • /
    • v.12 no.4
    • /
    • pp.191-200
    • /
    • 1997
  • This paper discusses prediction of the sound pressure level produced by simple engine exhaust systems(plain pipe, plain expansion chamber pipe, plain expansion chamber with internally extended inlet and outlet pipe, perforated pipe enclosed in a plain expansion chamber) and a computer program has been developed which predicts the sound pressure level and the frequency spectrum. The program utilizes unsteady flow gas dynamic theory and acoustic theory to predict the pressure-time history in the exhaust system and the mass flow rate-time history at the open end of the system and the sound pressure levels(1/3 Octave band levels) and the frequency spectrum in semi-anechoic room. The predictions are compared with measured levels and show a high degree of correlation.

  • PDF

The allowable sound levels of major noise sources for the indoor-noise requirements of KHST (한국형 고속전철(KHST) 실내소음 설계기준을 위한 주요 소음원의 허용소음도)

  • 조국래;이우식
    • Journal of the Korean Society for Railway
    • /
    • v.4 no.1
    • /
    • pp.9-15
    • /
    • 2001
  • It is required that the indoor-noise level of KHST (Korean High Speed Train) should be lower than 66 dB(A) at 300 km/h. In this study, the indoor-noise level of KHST has been predicted to determine the maximum allowable sound power levels of major noise sources. It is found that the indoor-noise requirements for KHST can be met by increasing the transmission losses of the floor and side-wall structures as well as by lowering the sound power levels of the major noise sources.

  • PDF

Acoustic Power Estimation of Highway Traffic Noise (고속도로 교통소음의 음향파워 평가)

  • 오정한;조대승;장태순;강희만;이용은;박형식;권성용;이성환
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2001.11b
    • /
    • pp.1273-1279
    • /
    • 2001
  • Precise highway traffic noise simulation and reduction require the accurate data for sound power levels emitted by vehicles, varied to road surface, traffic speed, vehicle types and makers, different from countries to countries. In this study, we have elaboratively measured domestic highway traffic noise and parameters affecting noise levels at the nearside carriageway edge. From numerical simulation using the measured results for highway traffic noise, we propose not only two correction factors to enhance the accuracy of highway traffic sound power estimation using ASJ Model-1998 but also its typical power spectrum according to road surface type. The measured and predicted highway traffic noise levels using the proposed sound power shows little difference within 1 dB.

  • PDF

An Study on the Sound Attenuation of Audible Fire Alarm Device in Apartment Buildings (공동주택에서의 화재 경보음 전달특성에 관한 연구)

  • Lee, Min-Joo;Kim, Myung-Jun;Yoon, Myong-O
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.11a
    • /
    • pp.658-661
    • /
    • 2005
  • In many fire emergencies, the auditory fire alarm signals are very important to save the occupant's life. But as the sound insulation of building elements has been improved, it is more difficult for occupant to recognize the fire alarm signals when the audible fire alarm worked. This is the first study to show the sound attenuation of audible fire alarm device in apartments. We measured and analyzed the sound attenuation level in seven units. The result showed that it was not sufficient to detect the sound from the fire alarm device in bedrooms. Whether the fire alarm device worked or not, the differences of sound level in bedrooms were below 1$\sim$10dBA. To give the minimum sound level 60dBA in bedrooms, the proper sound levels from alarm device installed in livingrooms were suggested using computer simulation.

  • PDF