• 제목/요약/키워드: Sound Pressure Level Distribution

검색결과 58건 처리시간 0.023초

벽식구조 표준시험동에서 중량충격음장에 관한 연구 (Investigation of the heavy-weight floor impact sound field in a testing building with bearing wall structure)

  • 유승엽;이신영;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.969-973
    • /
    • 2007
  • The heavy-weight floor impact sound field of the receiving room in a testing building with bearing wall structure was investigated using bang machine and impact ball. The sound field was investigated through the impact sound pressure level distribution by the field measurement and computational analysis. Predicted sound field using the computational analysis agree with measurement result in the low frequency band. Result shows that standard deviations of the single number rating value are about 2dB in each impact source. Particularly, impact sound pressure level at 120cm height in 63Hz octave band was 5dB lower than spatial averaging value. It was found that receiving positions in the ministry of construction and transportation notice should be reconsidered.

  • PDF

외부소음에 대한 공동주택 실내 소음레벨분포에 관한 실험적 연구 (An Experimental Study on the Prediction of Indoor Sound Level Distribution in Apartment for Exterior Noise)

  • 박현구;김종빈;강동영;장현충;송혁;김선우
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2001년도 춘계학술대회논문집
    • /
    • pp.259-264
    • /
    • 2001
  • It is necessary to predict the sound pressure level(SPL) in rooms before designing an apartment when exterior noises are produced. In order to predict SPL for an apartment that has some specific exterior noises, the following should be known: the characteristics of outdoor noise, sound insulation performance and sound level differences of each room. The purpose of this study is to find out the possibility of predicting sound pressure level of rooms in an apartment by analysing sound level differences among rooms. Sound sources used in this experiment are construction noise, aircraft noise, railroad noise, road traffic noise and white noise as a reference to compare with the previous four. These noises were recorded and reproduced by speaker. As a result, we found that within the sound reduction pattern, the sound difference level appeared uniform depending on the sound insulation characteristics of the windows installed when facing the noise source. When the windows having the same acoustic performance were installed, the SPL in each room resulted in nearly the same values.

  • PDF

산업장 소음의 강도 및 주파수 특성에 관한 조사연구 (The Study on the Characteristic Sound Intensity and Frequency of Noise Exposure at Occupational Sites)

  • 김광종;차철환
    • 한국산업보건학회지
    • /
    • 제1권2호
    • /
    • pp.181-191
    • /
    • 1991
  • The present study determined the overall noise level and the distribution of sound pressure level over audible frequency range of noise produced at various work sites. Work-related noise greater than 80dBA produced from 98 separate work sites at 37 manufacturing companies and machine shops were analysed for the overall sound level (dBA) and frequency distribution. In addition, to determine the possible hearing loss related to work site noise, a hearing test was also conducted on 1,374 workers in these work sites. The results of the study were as follows ; 1. Of the total 98 work sites, 57 work sites(58.2%) produced noise exceeding threshold limit value (${\geq}90dBA$) set by the Ministry 01 Labor. In terms of different manufacturing industries the proportion of work sites which exceeded 90dBA was the highest for the cut-stone products industry with 6/6 work sites and lowest for the commercial printing industry with 1/13 work sites. 2. The percentage of workers who were exposed to noise greater than 90dBA was 19.8% (1,040 workers) 01 the total 5,261 workers. In terms of different industries, cut-stone products industry had the most workers exposed to noise exceeding 90dBA with 82.8%, textile bleaching and dyeing industry was next at 30.6% followed by fabricated metal products industry with 27.9%, plastic products manufacturing industry had the lowest percentage of workers exposed to 90dBA exceeding noise with 4.5%. 3. There was a statistically significant correlation between the frequency of noise-induced hearing loss and the percentage of workers exposed to noise exceeding 90dBA (P<0.05). 4. The frequency analysis of noise produced at the 98 work sites revealed that 44 work sites (44.9%) had the maximum sound pressure level at high-frequencies greater than 2KHz. In addition, significantly higher sound pressure level was detected at the high-frequencies at 90dBA exceeding work sites as compared to below 90dBA work sites (P<0.01). 5. The differences in sound level meter's A-and C-weighted sound pressure levels were analysed by frequencies. Of the 28 work sites which showed 0-1 dB difference in the two weighted sound levels, 20 work sites (71.4%) had significantly higher sound pressure levels at high-frequencies greater than 2KHz (P<0.01). Furthermore, there was a tendency for higher sound pressure levels to occur in the high-frequency range as the differences in the two weighted sound levels decreased.

  • PDF

T자형 복도 공간의 비상 방송용 확성기 배치별 음압 레벨과 음성 명료도 비교 (Comparison of Sound Pressure Level and Speech Intelligibility of Emergency Broadcasting System at T-junction Corridor Space)

  • 정정호;이성찬
    • 한국화재소방학회논문지
    • /
    • 제33권1호
    • /
    • pp.105-112
    • /
    • 2019
  • 본 연구에서는 T자형의 복도 연결 공간에서 비상 방송음이 명료하고 고르게 전달되는지를 건축음향 시뮬레이션을 이용하여 알아보았다. 복도 공간의 흡음성능 변화, 비상 방송용 확성기의 설치 위치와 간격을 변화시켜 보았으며 변화에 따른 음압 레벨 분포, 음성 전달 지수(STI, RASTI) 분포를 비교하였다. 시뮬레이션 결과 명료한 음성 전달을 위해서는 비상 방송용 확성기를 T자형 복도 연결부의 중심에서 약 10 m를 이격시켜 설치하는 것이 좋은 것으로 나타났다. NFSC의 25 m 설치 간격을 좁히는 경우 더욱 명료하고 충분한 음량을 갖는 비상 방송음이 고르게 전달될 수 있는 것으로 나타났다.

쐐기소리에서 분류-쐐기의 상호작용과 소리의 방사 (Jet-Edge Interaction and Sound Radiation in Edgetones)

  • 권영필
    • 대한기계학회논문집
    • /
    • 제18권3호
    • /
    • pp.584-590
    • /
    • 1994
  • A theoretical model has been developed to analyze the jet-edge interaction and the sound radiation. The edge responding to the sinuous impinging jet is regarded as an array of dipoles and their strength is determined by the boundary condition on the edge surface. The surface pressure distribution and the edgeforce are estimated using these dipoles. Then the pressure amplitude and directivity of the sound field is obtained by summing the radiating sounds from the dipole sources. It is found that the effective source is located a little distance downstream from the edge tip. And the directivity of the sound radiation is cardioid pattern near the edge but dipole pattern far from the edge. The theoretical model is confirmed by comparing the theoretical prediction of the edgeforce and sound pressure level with available experimental data.

임팩트 볼에 의한 중량충격음 측정에 있어서 수음실 음장특성의 영향 (Effects of the sound field characteristics of the receiving room on heavy-weight impact sound measurement generated by impact ball)

  • 유승엽;이신영;정영;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2006년도 추계학술대회논문집
    • /
    • pp.622-625
    • /
    • 2006
  • This study is a fundamental investigation for standardization of the heavy-weight floor impact measuring method by the impact ball. The distribution chrematistics of floor impact sound level and reverberation time in a receiving room of the testing building for floor impact sound were measured with variations of number and arrangement of the sound-absorbing materials. Total 8 cases were investigated. The distribution of the floor impact sound level($L_{i,\;Fmax}$) was measured at 30 points with same intervals. The absorption coefficient of the room is 0.10 in case of installation of 6 absorbing materials and 0.02 in case of non-installation. The distribution shape of the impact sound pressure level was similar to the result of the bang machine driving at the measured frequency range. However, the overall reduction of the impact sound level investigated in the 125 to 500 Hz shows that the sound absorption characteristics of the receiving room actually affects the result of the heavy-weight impact measurement.

  • PDF

소형 이륜자동차의 머플러 배기압력 특성에 관한 실험적 연구 (Experimental Study on the Exhaust Pressure Charactieristics in the small motorcycle.)

  • 이중섭;최석천;배재영;정한식;정효민;서정세
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2004년도 추계학술대회
    • /
    • pp.678-683
    • /
    • 2004
  • In this study, a experiment has been developed for measuring the exhaust pressure of muffler at inlet and outlet. The main experimental parameters were a engine speed and sound absorbing material in the muffler. The muffler sound absorbing material tested a steel wool and glass wool. The exhaust pressure was measured with pressure sensor. The phase of exhaust pressure with high speed was moved according to increasing engine speed comparing with exhaust pressure with low speed. Also, the distribution of exhaust pressure at the model-1, 2 and 3 are similar with distribution of exhaust pressure at muffler inlet.

  • PDF

3차원 유동해석을 통한 차량 배기소음 예측에 관한 연구 (Prediction of Vehicle Exhaust Noise using 3-Dimensional CFD Analysis)

  • 진봉용;이상호;조남효
    • 한국자동차공학회논문집
    • /
    • 제9권5호
    • /
    • pp.148-156
    • /
    • 2001
  • Computational Fluid Dynamics (CFD) analysis was carried out to investigate exhaust gas flow and acoustic characteristics in the exhaust system of a passenger car. Transient 3-dimensional flow field in the front and rear mufflers was simulated by CFD and far-field sound pressure was modeled by a simple monopole source method. Engine performance simulation was also performed to obtain the boundary condition of instantaneous fluid flow variation at the inlet of the exhaust system. Detailed exhaust gas flow characteristics such as velocity and pressure distribution inside the mufflers were presented and the pulsating pressure amplitude was compared at several positions in the exhaust system to deduce sound pressure level. The present method of the acoustic analysis coupled with CFD techniques would be very effective for the prediction of sound noise from vehicle exhaust systems although the effects of the inlet boundary condition and heat transfer on the accuracy of the prediction have to be validated through further studies.

  • PDF

개구부로 연결된 3중 커플룸의 음향특성 (Acoustic Properties of Three-room Coupled System by Connected Two Apertures)

  • 나혜중;임병덕
    • 한국소음진동공학회논문집
    • /
    • 제26권3호
    • /
    • pp.340-349
    • /
    • 2016
  • A coupled room system consists of adjacent rooms and apertures where the sound energy is exchanged between the two rooms. Acoustically, a coupled room system shows a non-exponential decay profile. Most of the related researches have been to analyze the acoustic properties of two-room coupled system so far whereas three-room coupled system were seldom studied. In this regard, this paper aims to analyse the distribution of sound pressure level, sound decay curve of three-room coupled system and sound energy flow between them by using the acoustic diffusion model and to further verify them through experiments. Firstly, the sound pressure level distribution and mean sound pressure level in the steady-state condition are analyzed at various frequencies and source locations. Good agreements are observed in both experiments and analysis results. Secondly, two double slope effect quantifiers of sound attenuation, LDT/EDT and LDT/T10 are compared at various frequencies and for different source locations. The result indicates that LDT/T10, less affected by the early reflection patterns than LDT/EDT, is more suitable to the analysis and experiments of a multi-slope sound decay curve. Lastly, the sound energy flow in each room is analyzed based on the acoustic diffusion model. After the early decay stage, the sound energy is observed to flow from the room with a long reverberation time to the room with a short one.

표준시험동 바닥충격음 측정위치에 대한 고찰 (Investigation of receiving position in the measurement method for floor impact sound in a testing building)

  • 이신영;유승엽;전진용
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2007년도 춘계학술대회논문집
    • /
    • pp.964-968
    • /
    • 2007
  • The measurement of floor impact sound have been standardized in KS 2810-1 and 2. The height of receiving microphones position is specified in the standard as 1.2m which is almost half height of apartment rooms as a listening position. In this study, receiving positions are investigated by measuring the distribution of sound pressure levels at 792 receiving microphone positions in the standard testing building. Standard impact sources, tapping machine and impact ball, are driven on the center position in the source room where is located at the above floor. It was found that the distribution of sound pressure levels in the receiving room indicates significant deviation at different frequencies there is more than 5dB drop at 63Hz but 2dB rise at 125Hz at a height of 1.2m when the impact ball is driven, in the other case of a generating tapping machine there is more than 2dB rise at 125Hz at a height of 1.2m due to room modes.

  • PDF