• 제목/요약/키워드: Sound Pressure Characteristics

검색결과 373건 처리시간 0.029초

중이 이식형 보청기에서 DFMT의 진동에 의한 등골 및 고막 방향으로 전달되는 진동력 측정 (Measurement of transmitted vibration to stapes and tympanic membrane by DFMT's vibration in implantable middle ear hearing devices)

  • 이명원;성기웅;임형규;김민우;정의성;이장우;김동욱;이정현;이상흔;이규엽;조진호
    • 센서학회지
    • /
    • 제18권4호
    • /
    • pp.286-293
    • /
    • 2009
  • The implantable middle ear hearing devices(IMEHDs) have been developed to overcome the conventional hearing aid's problem(ringing effect caused by the acoustic feedback, cosmetic problem, etc.). In the IMEHDs, the vibrating transducer is a key component because its vibration enables to hear for hearing impaired people. The vibrating transducer is implanted on ossicular chain by surgical operation. The coupling status between implanted transducer and ossicular chain has an effect on delivering vibrating force from transducer to stapes. Noninvasive method is required to investigate the output characteristics of IMEHDs after implementation. Recently, emitted sound pressure measuring method of tympanic membrane is proposed to investigate the output characteristics of IMEHDs. However, the relationship between displacement of stapes and sound pressure by tympanic membrane was not cleared. In this paper, displacement of stapes and sound pressure by tympanic membrane were measured using the differential floating mass transducer(DFMT) that implanted on the ossicular chain of the human temporal bone and physical ear model. Through the experiments results, the relationship between displacement of stapes and sound pressure by tympanic membrane was investigated.

실험계획법을 이용한 차량공조시스템의 음질 특성 분석 (Analysis of Subjective Sound Quality Characteristics for the HVAC using the Design of Experiments : Sharp, Annoy)

  • 윤태건;심현진;이정윤;오재응;김성수
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 춘계학술대회논문집
    • /
    • pp.634-637
    • /
    • 2005
  • A subjective index of sound quality when it hit him is required since human listening is very sensitive and complex. Sound quality evaluation it leads consequently rightly in each situation and it composes a sound quality factor. But one of the levels in interest frequency range is substitute we cannot see the tendency of frequency substitute at whole that is executes a clear voice evaluation. Design of experiment is used and dividing 12 equally in frequency domain, the sound quality using sharpness and annoyance is performed by modifying each of frequency domains. Design of experiment method reduces much number experiment very effectively and each main effect of domain solution analysis, such as a case of sharpness and annoyance, the change of domain (increase and decrease of sound pressure level, or change nil) can grasp a type of effect should have influenced to a sound quality, and it will be able to select the objective frequency domain which hits to the sound quality. Through these obtained results the physical changes of level at arbitrary frequency domain sensitivity can be adapted.

  • PDF

건축 설비기기 소음의 특성 및 평가에 관한 연구 (A Study on the Evaluation and Characteristics of Architectural Facility-equipment Noise in Building)

  • 변운섭;최둘;김재수
    • 설비공학논문집
    • /
    • 제21권10호
    • /
    • pp.537-544
    • /
    • 2009
  • On account of the technological development, intelligent building is on increasing where the artificial regulation on indoor environment is possible, thence the concern about those facilities such as water-supply facility, water-heater and drainage facility has becomes higher. However, due to diversification and complicated system of the facility-equipments, the noise generating from such facility equipment is gradually becoming a problem, and since especially equipment noises arising at the machine room frequently infringe into the resident's pleasant living environment with the complex types of an air-borne sound and a structure-borne sound, it is becoming the civil complaint. On such viewpoint, this Study ever observed the characteristics of noise generating from various facility-equipments in the building, and intended to evaluate the facility-noises by use of the valuation index such as PSIL, N, NC, NR. As result of, the facilities noise which happens in the machine room makes normal conversation very difficult due to high sound pressure level. Based on such data, this study is willing to present it as an essential material for establishment an efficient measure against the facility-noises arising at machine room hereafter.

박막과 음장의 연성에 의한 저주파 소음 저감 (Low Frequency Noise Reduction by Acoustic Coupling with Membrane)

  • 박수경;김양한
    • 소음진동
    • /
    • 제7권4호
    • /
    • pp.579-588
    • /
    • 1997
  • When a membrane couples with compressive fluid, waves on the membrane follow a typical dispersion relations. One of characteristics of this relations is that evanscent waves occur below cutoff frequency. We have attempt to use this spatially decaying characteristics as a low frequency sound absorber. Theoretical development has required to solve membrane-fluid coupled linear differential. The solution has been successfully obtained by using eigenfunctions. To assure the obtained solution, experiment was also performed. The comparison was quite satisfactory. We conclude, based on these theoretical as well as experimental evidences, that it is very likely possible to use a membrane as a low frquency sound control element.

  • PDF

다공관 출구로부터 방출되는 펄스파에 관한 실험적 연구 (An Experimental Study on the Impulse Wave Discharged from the Exit of a Perforated Pipe)

  • 허성욱;이동훈;김희동
    • 한국추진공학회:학술대회논문집
    • /
    • 한국추진공학회 2003년도 제20회 춘계학술대회 논문집
    • /
    • pp.67-71
    • /
    • 2003
  • The propagation characteristics of the impulse wave discharged from the exit of a perforated pipe is investigated through a simple shock tube facility. The pressure histories and directivities of the impulse wave propagating outside from the exit of pipe with several different configurations are analyzed for the range of the incident weak shock wave Mach number between 1.02 and 1.2. In the shock tube experiments, the impulse wave are visualized by a Schlieren optical system for the purpose of understanding its propagation characteristics. The experimental results show that for the near sound field the impulse noise strongly propagates toward to the pipe axis, but for the far sound field the impulse noise uniformly propagates toward to the omnidirections, indicating that the directivity pattern is almost same regardless of the pipe type. Especially, it is shown that the perforated pipe has a little performance to reduce the impulse noise only for the near sound field

  • PDF

원음장에서의 충격성 소음전파에 관한 실험적 연구 (An Experimental Study on the Propagation of Impulse Noise in the Far Sound Field)

  • 송화영;제현수;이주원;이성태;이동훈
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.852-855
    • /
    • 2004
  • This experimental study describes the propagation characteristics of the impulse noise emitted from the exit of a straight pipe attached to the open end of a simple shock tube. The sound pressure level and directivity of the impulse noise propagating from the exit of pipe with several different diameters are measured in the far sound fold for the range of the incident shock wave Mach number between 1.07 and 1.26. The experimental results showed that the peak values of impulse noises had a strong dependance on the exit diameter of a pipe and the shock wave Mach number. The impulse noise had the directivity propagating toward to the pipe axis and the characteristics of inverse square law of propagation distance. Moreover, it was shown that the one-third octave band SPL of impulse noise was almost constant regardless of the frequency band.

  • PDF

주거환기용 시로코홴의 공력 및 소음 특성 연구 (A Study on Aerodynamic and Noise Characteristics of a Sirocco Fan for Residential Ventilation)

  • 김진혁;송우석;이승배;김광용
    • 한국유체기계학회 논문집
    • /
    • 제13권2호
    • /
    • pp.18-23
    • /
    • 2010
  • This paper presents a procedure for the aerodynamic and aeroacoustic characteristics of a sirocco fan. For the aerodynamic and aeroacoustic analyses of the sirocco fan, three-dimensional steady and unsteady Reynolds-averaged Navier-Stokes equations are solved with a shear stress transport turbulence model for turbulence closure. The flow analyses were performed on a hexahedral grid using a finite-volume solver. The validation of the numerical results is performed by comparing with experimental data for the pressure, efficiency and power. The internal flow analyses of the sirocco fan are performed to understand the unstable flow phenomenon on the casing for the wall pressure and internal flow characteristics at each position. It was found that fluctuation of pressure and locally concentrated noise source are observed near the cut-off and expansion regions of the casing.

물성변화에 따른 압전형 마이크로스피커의 특성 (Characteristics of Piezoelectric Microspeakers according to the Material Properties)

  • 정경식;조희찬;이승환
    • 한국전기전자재료학회논문지
    • /
    • 제21권6호
    • /
    • pp.556-561
    • /
    • 2008
  • This paper reports the characteristics of piezoelectric microspeakers that are audible in open air with high quality piezoelectric AlN thin film according to the materials properties. When we use a tensile-stressed silicon nitride diaphragm as a supporting layer, the Sound Pressure Level (SPL) is relatively small and constant at low frequency region and shows about 70 dB at 10 kHz. However, in case of a compressively stressed composite diaphragm, the SPL of the fabricated microspeakers shows higher output pressure than those of a tensile-stressed diaphragm. It produces more than 66 dB from 100 Hz to 15 kHz and the highest SPL is about 100 dB at 9.3 kHz with $20V_{peak-to-peak}$, sinusoidal input biases and at 10 mm distances from the fabricated microspeakers to the reference microphone. From the experimental results, it is superior to have a compressively composite diaphragm in order to produce a high SPL in piezoelectric microspeaker.

자동차 흡기계의 방사소음 예측에 대한 연구 (Prediction of the Radiated Noise from the Vehicle Intake System)

  • 김회전;이정권;이성현
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2005년도 추계 학술대회논문집(수송기계편)
    • /
    • pp.105-108
    • /
    • 2005
  • The radiated noise from the automotive intake system should be predicted at the design stage. To this end, the precise measurement of in-duct acoustic source parameters of the intake system, i.e., the source strength and source impedance, is essential. Most of previous works on the measurement of acoustic source parameters were performed under a fixed engine speed condition. However, the requirement of vehicle manufacturer is the noise radiation pattern as a function of engine speed. In this study, the direct method was employed to measure the source parameters of engine intake system under a fixed engine speed and engine run-up condition. It was noted that the frequency spectra of source impedance hardly changes with varying the engine speed. Thus, it is reasonable to calculate the source strength under the engine run-up condition by assuming that source impedance is invariant with engine speed. Measured and conventional source models, i.e., constant pressure source, constant velocity source, and non-reflective source, were utilized to predict insertion loss and radiated sound pressure level. A reasonable prediction accuracy of radiated sound pressure level spectra from the intake system was given in the test vehicle when using the measured source characteristics which were acquired under the operating condition.

  • PDF

물성변화에 따른 압전형 마이크로스피커의 특성 (Characteristics of Piezoelectric Microspeakers according to the Material Properties)

  • 정경식;박종선;조희찬;이승환
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2007년도 추계학술대회 논문집
    • /
    • pp.37-38
    • /
    • 2007
  • This paper reports the characteristics of piezoelectric microspeakers that are audible in open air with high quality piezoelectric AlN thin film according to the materials properties. When we use a tensile-stressed silicon nitride diaphragm as a supporting layer, the Sound Pressure Level (SPL) is relatively small. However, the SPL of the fabricated microspeakers that have compressive-stressed composite diaphragm show higher output pressure than those of tensile-stressed diaphragm. It produces more than 60dB from 100Hz to 15kHz and the highest SPL is about 100dB at 9.3kHz with 20 Vpeak-to-peak sinusoidal input biases and at 10 mm distances from the fabricated microspeakers to the reference microphone.

  • PDF