• Title/Summary/Keyword: Sound Installation

Search Result 116, Processing Time 0.023 seconds

Crying Sea, The Sound Installation: Artistic Considerations for Coexistence between Human and Technology

  • Park, Jungsun;Wi, Hyeongseok;Park, Sungwoo
    • Journal of Multimedia Information System
    • /
    • v.9 no.1
    • /
    • pp.43-50
    • /
    • 2022
  • As the discourse on Anthropocene grows, this exploratory research investigates the interrelationship and interconnectivity between humanity and technology by analyzing a sound art installation created by the author. Crying Sea is a sound installation that uses plastic wastes collected from the shore to create symbolic narratives and artistic experience connecting humans, objects, and nature through interactive digital technology. In this installation, the audiences are guided to walk over the wastes, and the sounds created by the footsteps are recorded in real-time, which then are distorted and amplified into disturbing sounds through speakers filling up the room. In analyzing this artwork, three theories from technological, philosophical, and ecological backgrounds were used; specifically, Bernard Stiegler's pharmakon theory, Dona Haraway's cyborg manifesto, and Timothy Morton's dark ecology theory. A common factor revealed from all three theories by analyzing the Crying Sea is that humans, technologies, and all other entities within nature are interconnected and resonated. The awareness of this recursive relationship allows us to consider sustainable balancing.

The Research of the Heavy-Weight Impact Sound Characteristic by Live load Installation on the Source Room (공동주택 음원실 바닥의 하중 설치에 따른 중량충격음 특성에 관한 연구)

  • Kim, Kyoung-Woo;Yang, Kwan-Seop;Sohn, Jang-Yeul
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.6
    • /
    • pp.235-242
    • /
    • 2007
  • The test and evaluation of floor impact sound is mainly conducted before move in the residence. Floor impact sound generating is actually the conditions in which a heavy load like a curtain and furniture is installed, the situation before and after move in the residence is different. In this study, we investigate the floor impact sound variations according to the live load installation like furniture in the source room. The vibration acceleration level and floor impact sound level variation were measured before and after live load ($200kg/m^2$) installation in the floor impact sound test building and the field. The difference was not large although the vibration acceleration level and the floor impact sound level were reduced through measurement result of load installation. Resonance frequency was not changed by load installation.

Evaluation of Floor Impact Sound Performance according to the installation of Ceiling and Wall (천장 및 벽구성 방법에 따른 바닥충격음 특성평가)

  • Kim, Kyoung-Woo;Choi, Hyun-Jung;Yang, Kwan-Seop;Lee, Seung-Eon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2004.11a
    • /
    • pp.261-264
    • /
    • 2004
  • Impact sounds, such as those created by footsteps, the dropping of an object or the moving of furniture, can be a source of great annoyance in residential buildings. The character and level of impact noise generated depends on the object striking the floor, on the basic structure of the floor, and on the floor covering. This study base on the evaluate of isolation performance of impact sound according to the installation of ceiling and wall. In this test, we measured the reduction of impact sound in the case of inserting absorption materials, increasing of the thickness of air layer and using anti-vibration rubber in ceiling, install of absorption materials in wall. The results of this study show that treatment of ceiling and wall have some reduction of the light weight impact sound and heavy weight impact sound.

  • PDF

A Study on an Analysis of Noise Reduction Effects using the tentatively Installed Sound-absorbing Materials in Metro Tunnel (도시철도 터널내 흡음재 시험설치 및 소음저감효과 분석에 관한 연구)

  • Hong, Chul-Kee;Jeong, Ri-Taek;Kim, Byeong-Hong
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.125-131
    • /
    • 2008
  • This research tries to analyze and investigate the effects of the noise reduction test for the sound-absorbing materials installed tentatively on Metro Line 5. Though the noise reduction effects of each sound-absorbing material showed that there was about $2{\sim}5\;dB$ compared with before and after of the tentative installation, it shows that the noise reduction effects are reducing because of the section change condition such as dust absorption and the rail abrasion as time passes after the tentative installation. Also, many difficulties are occurring in the maintenance of the orbit facilities because of the installation of sound-absorbing materials. Though various abroad products for noise reduction are imported like this, the researches for the noise reduction effect increase for this and the improvement direction are being required because of the poor circumstance of the efficiency aspect compared to the economic investment effect because those are not suited to the character of domestic Metro.

  • PDF

Effects of the sound field characteristics of the receiving room on heavy-weight impact sound measurement generated by impact ball (임팩트 볼에 의한 중량충격음 측정에 있어서 수음실 음장특성의 영향)

  • Yoo, Seung-Yup;Lee, Sin-Young;Jeong, Young;Jeon, Jin-Yong
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.622-625
    • /
    • 2006
  • This study is a fundamental investigation for standardization of the heavy-weight floor impact measuring method by the impact ball. The distribution chrematistics of floor impact sound level and reverberation time in a receiving room of the testing building for floor impact sound were measured with variations of number and arrangement of the sound-absorbing materials. Total 8 cases were investigated. The distribution of the floor impact sound level($L_{i,\;Fmax}$) was measured at 30 points with same intervals. The absorption coefficient of the room is 0.10 in case of installation of 6 absorbing materials and 0.02 in case of non-installation. The distribution shape of the impact sound pressure level was similar to the result of the bang machine driving at the measured frequency range. However, the overall reduction of the impact sound level investigated in the 125 to 500 Hz shows that the sound absorption characteristics of the receiving room actually affects the result of the heavy-weight impact measurement.

  • PDF

Design of Spontaneous Acoustic Field Reproducing System (능동형 음장조성시스템의 설계)

  • Kook, Chan;Jang, Gil-Soo;Jang, Gyung-Sung;Kim, Sun-Woo
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2005.05a
    • /
    • pp.611-614
    • /
    • 2005
  • The introduction of the sound based on the soundscape concept has the effect to offer comfortable sound environments at the public spaces by masking undesired ones and to identify the spaces. Sound installation, sound sculptor and the soundscape are used for these purpose, but the most important factors to be considered therein are to determine what kind of sounds to offer and how to adjust them to the changing circumstances. But, installing, maintaining and adjusting the soundscape system directly in the field will ensue numerous problems as well as high costs. And, even if it was epochal and novel when the soundscape is first installed at a space, new different sound environment is necessary to continue the effectiveness as time goes. Thus, this study aims at devising the instrument system that has the artificial intelligence, enables to remote control, with a great ease, numerous variables, reproduce most agreeable sound sources, and can produce the proper sound fit to the space automatically and spontaneously.

  • PDF

Analysis of Sound Transmitting System using Power line Communication Technique (전력선을 이용한 음향전달 시스템의 구성 및 특성 분석)

  • Kim, Ho-Soo;Lee, Myung-Sub;Koo, Kyung-Wan;Han, Sang-Ok
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.18 no.3
    • /
    • pp.128-134
    • /
    • 2004
  • This paper presents a result of sound transmitting system with power line communication technique. Sound transmitting system is a transmitter which transmits modulated audio signal to power to power line and receiver which is capable of detecting it with earphone or speaker. It has been evaluated with the frequency characteristics and spectrum analysis. And, from the result of evaluation on the developed system, we confirmed the superior sound transmitting characteristics, and the possibility of application on a language laboratory.

Experimental discussion on the installation of filler wall for sound insulation measurements of shipboard windows (선박용 창의 차음성능 측정용 충진벽체 설치에 관한 실험적 고찰)

  • Kim, Sang-Ryul;Kang, Hyun-Ju;Kim, Hyun-Sil
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2008.04a
    • /
    • pp.276-279
    • /
    • 2008
  • In order to measure sound transmission loss (STL) of a shipboard window of small size, a special partition is built into the test opening between two reverberation rooms and the specimen is placed in that partition. For high sound insulation, the filler wall often has multi-layered structure such as double-brick wall or buckhead structure with thick steel plate, absorptive material, and sandwich panels. This paper discusses the installation method of a multi-layered filler wall that consist of gypsum boards, lead plates, and glass wool. The experimental results of various wall structures are introduced. The comparison between the results show that the sound bridge effect plays a significant role in lowering the maximum STL of the filler wall. It is also found that the higher the sound insulation performance of the filler wall is, the more important the franking transmission through other side wall of the test facility is.

  • PDF

Evaluation on Effect of Constitution of Timber Framed Floor on Insulation Performance Against Impact Sound by Field Measurements (현장실험을 통한 목조바닥의 구성요소가 충격음 차단성능에 미치는 영향 평가)

  • Park, Joo-Saeng;Lee, Sang-Joon;Kim, Se-Jong
    • Journal of the Korean Wood Science and Technology
    • /
    • v.40 no.6
    • /
    • pp.431-444
    • /
    • 2012
  • Constituents of timber framed floor affect the insulation performance against impact sound significantly. Among them, installation of massive sound absorbing layer and reinforcement of stiffness of timber floor have been considered as major factors that improve the insulation performance against impact sound. Researches on evaluating the effect of floor constitutions have been carried out through the field measurements for timber framed buildings in Korea. It is concluded that the impact sound pressure level at the relatively lower frequency governs the overall insulation performance, and can be improved by the installation of sound absorbing layer and reinforcement of floor stiffness. Especially, the insulation performance against heavy impact sound was improved significantly when the massive cement mortar layer for floor heating system was installed and the stiffness was reinforced by shortening the joist span using additional beam at the mid-position of original span.

Correlation Between Dynamic Stiffness of Resilient Materials and Lightweight Floor Impact Sound Reduction Level (완충재 동탄성계수와 경량바닥충격음 저감량의 상관성)

  • Kim, Kyoung-Woo;Jeong, Gab-Cheol;Sohn, Jang-Yeul
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.8
    • /
    • pp.886-895
    • /
    • 2008
  • Resilient materials are generally used for the floating floors to reduce the floor impact sound. Dynamic stiffness of resilient material have a close relation with the floor impact sound reduction. In this study, to examine the relationship between dynamic stiffness and lightweight impact sound level, the dynamic stiffness and floor impact sound level of 51 resilient materials were measured. The impact sound level of each of these resilient materials, whose dynamic stiffness was measured, was measured before and after installation, and the level difference (${\Delta}L$) was analyzed. The result of test showed that the dynamic stiffness of resilient materials decreased, the lightweight impact sound level also decreased, and there was a correlation between the dynamic stiffness and the lightweight impact sound, especially in the low frequency domain.