• Title/Summary/Keyword: Sorting factors

Search Result 95, Processing Time 0.029 seconds

Relationship between Environmental Factors and Macrobenthos Assemblages in Geum Estuary Tidal-flat (금강하구 갯벌 내 환경요인과 저서성무척추동물 군집 분포의 상관관계)

  • Yoo, Jae-Won;Lee, Chae-Lin;Park, Mi-Ra;Yoon, Jihyun;Kang, Sung-Ryong
    • Journal of Wetlands Research
    • /
    • v.21 no.1
    • /
    • pp.84-94
    • /
    • 2019
  • The Seocheon and Yubu Island mudflats in Geum Estuary are important stopover sites for migratory birds as energy supplementation area in the East Asia-Australasian Flyway. Benthic invertebrates in the tidal flats are important food resources for the migratory birds. In other words, benthic invertebrates in the tidal flats play an important ecological role in energy flow. This study was conducted to investigate the relationship between benthic invertebrate assemblages and environmental factors in Seocheon and Yubudo tidal flats in the Geum Estuary. As a result of the benthic invertebrate assemblage during the fall migration season, the total species number was 147, density and biomass were $1,772{\pm}1,342individuals/m^2$ and $445.1{\pm}807.6g/m^2$, respectively. Based on the appearance species and the density data, the result of analysis of mutual similarity among sampling sites was divided into two groups. Group A was the Macrophthalmus-Heteromastus community and Group B was the Spio-Urothoe-Mandibulophoxus community. Group B showed higher mean species number, density and biomass than Group A. The BIO-ENV analysis showed that the benthic invertebrate assemblages were most affected by the combination of sand content % and sediment sorting (${\rho}=0.500$). The variables of significant relationship with species number and biomass were sediment sorting (p=0.015) and the pore water DO(Dissolved Oxygen, p=0.003) in sediment, respectively.

Environmental Factors and Population Density of Brackish Water Clam, Corbicula japonica on Narndae Stream in Yangyang, Gangwon (양양 남대천 기수재첩, Corbicuza Japonica의 서식환경과 밀도)

  • 김완기;이채성;이정용;백국기;허성범
    • Journal of Aquaculture
    • /
    • v.15 no.1
    • /
    • pp.1-6
    • /
    • 2002
  • Hydrological factors prevailing in the Namdae stream were as follows : temperature = -0.2~$26.8^{\circ}C$, salinity = 0.50~3.21$\textperthousand$, DO = 5.21~8.13 ppm, $PO_{4}-P$ = ND~1.37 ppm, $NO_{2-}$ = 0.10~0.81 ppm, COD = 1.53~2.82 ppm, $H_2 S$ = ND~0.0012 ppm and IL = 0.85~1.36 %. Sediment was typical, gravelly sand or sand with very good sorting value ranging from 0.53 to 1.77$\varphi$. Population density of the clam C. japonica ranged from 2 to 464/$m^2$. The clams were divided into four size classes, based on shell length of small (0~10 mm), medium (10~20 mm), large (20~30 mm) and largest (>30 mm), and were encountered at the frequency of 3.2, 50.4, 43.3 and 3.1 %, respectively.

A Study on Types of stress in Nurses (Q 연구방법론에 의한 간호사의 스트레스 경험 유형에 관한 연구)

  • 정순영;양진향
    • Journal of Korean Academy of Nursing
    • /
    • v.23 no.2
    • /
    • pp.269-283
    • /
    • 1993
  • The purpose of this study was to develop a typology of stress in Nurses through the use of a Q methodology. The research was done between June, 1 and November 30,1992 Fifty nurse working in a hospital were interviewed to solicit statements on their opinions about concepts factors and coping methods related to stress. The statements which were collected were classified and categorized to a find list 48 statements. Each of the statements was written dr a separate card and 30 nurses were a shed to sort the co\ulcorner\ulcorner\ulcorner ac-cording the degree of agreement along with quasinormal distribution. The results of the sorting by each subject were coded and analyzed using the Quanal PC program. As a result of the analysis, four types were identified ; Type I was classified and named as ” neccessary for living Type II was named as ” stimulues to be avoided Type III was named as ” situation to be consumption. Type IV was named as ” self-limited problem which can be solve The correlation among each types was relatively high, but the characteristics of each type are unique and distinct. throughout this study, it was indentified that the type of Nurse’s stress would be formed.

  • PDF

Comparison of Distribution Competitiveness of the Mackerel Industry between Korea and Norway (우리나라-노르웨이 고등어산업의 유통 경쟁력 비교 연구)

  • KIM, Dae-Young;KANG, Jong-Ho
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.27 no.6
    • /
    • pp.1685-1692
    • /
    • 2015
  • This study examines the mackerel distribution systems in Norway which has a leading mackerel industry, and has the purpose of analyzing the effects of structural improvements for the development of Korea's mackerel industry. The landing and distribution status of Korea and Norway's mackerel industry was compared, and the effects of structural improvements was analyzed under the assumption that a number of factors would be improved after an analysis of competitiveness. Special features of the landing and distribution systems of mackerel in Norway are Reduction of transportation costs and transportation time through E-auctions, fish Pumps, freshness management using state-of-the-art equipment and technology such as sea water cooling systems, direct landing at processing factories and Automation through fully automated sorting & packaging systems. The distribution competitiveness of Korea and Norway's mackerel industry was compared through the qualitative review of landing time and the length of distribution channel, distribution costs due to differences in trading method, quality and hygiene management and merchandising. For Korea's mackerel industry to have international competitiveness, they must have efficiency throughout the phases of landing, processing and distribution systems as observed in case of Norway.

Syntaxonomical and Synchorological Characteristics of the Cool-temperate Mixed Forest in the Southern Sikhote Alin, Russian Far East (극동러시아 남연해주의 냉온대 침활혼합림의 군락분류 및 분포적 특성)

  • Kim, Jong-Won;I. Manyko
    • The Korean Journal of Ecology
    • /
    • v.17 no.3
    • /
    • pp.391-413
    • /
    • 1994
  • The northernmost type of the monogolian oak forests in the Russian Far East was studied in terma of syntaxonomy and synchorology. Hand-sorting method, computer program TWIN-SPAN, CANOCO and SYN-TAX III were engaged for the classification and data analysis. Correlation between plant communitie and environmental factors was analyzed by DCA (Detrended Correspondence Analysis) using NeCD (Net Contribution Degree) of species. Three plant communities were recognized: the Abieti holophyllae-Quercetum mongolicae, the Lespedezo-quercetum mongolicas and the Rosa ussuriensis-Quercus mongolica communit. They were included into the alliance Jeffersonio-Quercion monogolicae which is representative to the cool-Temperate forests mixed by conierous and broadleaved trees in southern Sikhote Alin. Human impact was signified as the most important factor to interpret the disjunction of plant communities of which DCA ordination yielded sharp contrasting objects (i.e. stands and species). In the amhi-Tonghae region, alaogous vegetation types such as the Jeffersonio-Quercion monogolicae of Russian Far East, the Quercion grosseserratae of Japanese Hokkaido and the Pino koraiensis-Quercion monogolicae of Koream peninusula were reviewed in terms of similarity of species composition and stratum structure. It is signified that the Jeffersonio-Quercion monogolicae was one of the continental types more similar to Korean alliance that to Japanese one.

  • PDF

A Study on the Optimal Conditions of the Biogas Sorting by Using the Polysulfone Membrane (다공성 분리막을 이용한 최적의 Bio-gas 분리인자 도출)

  • Lee, Seung-Won;Jeong, Chang-Hoon;Kim, Jung-Kwon
    • Journal of Environmental Science International
    • /
    • v.20 no.8
    • /
    • pp.1011-1019
    • /
    • 2011
  • The objective of this research is to evaluate optimal conditions of permeability and selectivity on the polysulfone membrane for efficiency of separation of $CH_4$ by checking four factors which are temperature, pressure, gas compositions and gas flow rates. When higher pressure was applied at the input, lower efficiency of recovery of $CH_4$ and higher efficiency of separation of $CH_4$ were shown. It has the tendency to show lower efficiency of recovery of $CH_4$ and higher efficiency of separation of $CH_4$ at the output as higher temperature at input. The lower flow rates make higher efficiency of recovery of $CH_4$ and lower efficiency of separation of $CH_4$. Finally, over 90% efficiency for $CH_4$ separation and recovery conditions are temperature ($-5^{\circ}C$), pressure (8 bar), gas composition rate (6:4) ($CH_4:CO_2$) and gas flow rate ($5\ell$/min). These conditions make higher separation and recovery efficiency such as 90.1% and 92.1%, respectively.

Optimal design of multiple tuned mass dampers for vibration control of a cable-supported roof

  • Wang, X.C.;Teng, Q.;Duan, Y.F.;Yun, C.B.;Dong, S.L.;Lou, W.J.
    • Smart Structures and Systems
    • /
    • v.26 no.5
    • /
    • pp.545-558
    • /
    • 2020
  • A design method of a Multiple Tuned Mass Damper (MTMD) system is presented for wind induced vibration control of a cable-supported roof structure. Modal contribution analysis is carried out to determine the dominating modes of the structure for the MTMD design. Two MTMD systems are developed for two most dominating modes. Each MTMD system is composed of multiple TMDs with small masses spread at multiple locations with large responses in the corresponding mode. Frequencies of TMDs are distributed uniformly within a range around the dominating frequencies of the roof structure to enhance the robustness of the MTMD system against uncertainties of structural frequencies. Parameter optimizations are carried out by minimizing objective functions regarding the structural responses, TMD strokes, robustness and mass cost. Two optimization approaches are used: Single Objective Approach (SOA) using Sequential Quadratic Programming (SQP) with multi-start method and Multi-Objective Approach (MOA) using Non-dominated Sorting Genetic Algorithm-II (NSGA-II). The computation efficiency of the MOA is found to be superior to the SOA with consistent optimization results. A Pareto optimal front is obtained regarding the control performance and the total weight of the TMDs, from which several specific design options are proposed. The final design may be selected based on the Pareto optimal front and other engineering factors.

A Study for reduction of the power loss of PV modules (PV moudule의 출력손실 저감요인 분석)

  • Lee, Sang-Hun;Kang, Gi-Hwan;Yu, Gwon-Jong;Ahn, Hyung-Keun;Han, Deuk-Young
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2011.11a
    • /
    • pp.45-50
    • /
    • 2011
  • The efficiency of solar cell was about 4[%] in initial stage of photovoltaic industry, but it has quite a lot of efficiency through technology advances. Today, the efficiency of c-Si solar cells is about 17 to 19[%] and the efficiency of PV modules is about 14 to 15 [%]. We called that electrical losses occurred in the Conversion of solar cells to PV modules are CTM loss(Cell To Module loss), the CTM loss typically has a value of about3~5[%]. The more efficiency of solar cell increase, differences are larger because the efficiency decrease owing to physical or technical problems occurred in the Conversion of solar cells to PV modules. In this study, the power loss factors occurred in the Conversion of solar cells to PV modules are analyzed and it is proposed that how to reduce losses of the PV module. The types of power loss factor are (1)losses of front glass and encapsulant(generally EVA sheet), (2)losses by sorting miss, (3)losses by interconnection, (4)losses by the field aging of PV modules. In further study, experimental and evaluation will be conducted to make demonstrate for proposed solutions.

  • PDF

A Study on Sustainable Laundry Behavior -Comparison between Korean and European Consumers- (국내 세탁행동의 지속가능성에 관한 연구 -유럽과의 비교를 중심으로-)

  • Wee, Jeeweon;Lee, Yoon-Jung;Jung, Hye Jung
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.45 no.3
    • /
    • pp.525-545
    • /
    • 2021
  • The purpose of this study was to assess the sustainability of laundry practices among Korean households in comparison with European households. A total of 329 responses were collected through an online survey and analyzed using SPSS. Detergent dosing, use of fabric softener, prewashing, rinsing, washing programs, and washing temperatures of Korean households were not optimal for sustainability. Only 11.2% of respondents followed dosage instructions while the majority based on load size. Use of fabric enhancer, prewashing, and rinsing were frequent. Cotton 40℃ was the most frequently used program (81.5%) while eco and cold wash programs were among the least (1.5%). In terms of laundry sorting, load size, drying, and ironing, more sustainable actions were reported. Laundry was often sorted by color, machines were commonly filled, and clothes tended to be air-dried and not excessively ironed. Gender was the primary socio-demographic factor denoting sustainable habits, with males being more attentive to instructions and care labels than females. European households, however, were more sustainable in all areas except for frequent ironing, and education level and employment status were significant factors affecting sustainable practices.

Experiment investigation on flow characteristics of open natural circulation system

  • Qi, Xiangjie;Zhao, Zichen;Ai, Peng;Chen, Peng;Sun, Zhongning;Meng, Zhaoming
    • Nuclear Engineering and Technology
    • /
    • v.54 no.5
    • /
    • pp.1851-1859
    • /
    • 2022
  • Experimental research on flow characteristics of open natural circulation system was performed, to figure out the mechanism of the open natural circulation behaviors. The influence factors, such as the heating power, the inlet subcooled and the level of cooling tank on the flow characteristics of the system were examined. It was shown that within the scope of the experimental conditions, there are five flow types: single-phase stable flow, flash and geyser coexisting unstable flow, flash stable flow, flash unstable flow, and flash and boiling coexisting unstable flow. The geyser flow in flash and geyser coexisting unstable flow is different from classic geysers flow. The flow oscillation period and amplitude of the former are more regular, is a newly discovered flow pattern. By drawing the flow instability boundary diagram and sorting out the flow types, it is found that the two-phase unstable flow is mainly characterized by boiling and flash, which determine the behavior of open natural circulation respectively or jointly. Moreover, compared with full liquid level system, non-full liquid level system is more prone to boiling phenomenon, and the range of heat flux density and undercooling degree corresponding to unstable flow is larger.