• Title/Summary/Keyword: Soon-dong

Search Result 5,143, Processing Time 0.053 seconds

A Numerical and Experimental Study for Fry-drying of Various Sludge (슬러지 유중 건조에 대한 전산 해석 및 실험적 연구)

  • Shin, Mi-Soo;Kim, Hey-Suk;Kim, Byeong-Gap;Hwang, Min-Jeong;Jang, Dong-Soon;Ohm, Tae-In
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.32 no.4
    • /
    • pp.341-348
    • /
    • 2010
  • The basic principle of fry drying process of sludge lies in the rapid pressure change of sludge material caused by the change of temperature between oil and moisture due to the difference of specific heat. Therefore, the rapid increase of pressure in drying sludge induces the efficient moisture escape through sludge pores toward heating oil media. The object of this study is to carry out a systematic investigation of the influence of various parameters associated with the sludge fry drying processes on the drying efficiency. To this end, a series of parametric experimental investigation has been made together with the numerical calculation in order to obtain typical drying curves as function of important parameters such as drying temperature, sludge diameter, oil type and sludge type. In the aspect of frying temperature, especially it is found that the operation higher than $140^{\circ}C$ was favorable in drying efficiency regardless of type of waste oil employed in this study. The same result was also noted consistently in the investigation of numerical calculation, that is, in that the sludge particle drying was efficiently made over $140^{\circ}C$ irrespective of the change of particle diameter. As expected, in general, the decrease of diameter in sludge was found efficient both experiment and numerical calculation in drying due to the increased surface area per unit volume. In the investigation of oil type and property, the effect of the viscosity of waste oil was found to be more influential in drying performance. In particular, when the oil with high viscosity, a visible time delay was noticed in moisture evaporation especially in the early stage of drying. However, the effect of high viscosity decreased significantly over the temperature of $140^{\circ}C$. There was no visible difference observed in the study of sludge type but the sewage sludge with a slightly better efficiency. The numerical study is considered to be a quite useful tool to assist in experiment with more detailed empirical modeling as further work.

A Numerical Study for Effective Operation of MSW Incinerator for Waste of High Heating Value by the Addition of Moisture Air (함습공기를 이용한 고발열량 도시폐기물 소각로의 효율적 운전을 위한 수치 해석적 연구)

  • Shin, Mi-Soo;Shin, Na-Ra;Jang, Dong-Soon
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.2
    • /
    • pp.115-123
    • /
    • 2013
  • Stoker type incinerator is one of the most popular one used as municipal solid waste (MSW) incineration because, in general, it is quite suitable for large capacity and need no preprocessing facility. Nowadays, however, since the combustible portion of incoming MSW increases together with the decrease of the moisture content due to prohibition of directly burying food waste in landfill, the heating value of waste is remarkably increasing in comparison with the early stage of incinerator installation. Consequently, the increased heating value in incinerator operation causes a number of serious problems such as reduction of waste amount to be burned due to the boiler heat capacity together with the significant NO generation in high temperature environment. Therefore, in this study, a series of numerical simulation have been made as parameters of waste amount and the fraction of moisture in air stream in order to investigate optimal operating condition for the resolution of the problems associated with the high heating value of waste mentioned above. In specific, a detailed turbulent reaction flow field calculation with NO model was made for the full scale incinerator of D city. To this end, the injection method of moisturized air as oxidizer was intensively reviewed by the addition of moisture water amount from 10% and 20%. The calculation result, in general, showed that the reduction of maximum flame temperature appears consistently due to the combined effects of the increased specific heat of combustion air and vaporization heat by the addition of water moisture. As a consequence, the generation of NOx concentration was substantially reduced. Further, for the case of 20% moisture amount stream, the afterburner region is quite appropriate in temperature range for the operation of SNCR. This suggests the SNCR facility can be considered for reoperation. which is not in service at all due to the increased heating value of MSW.

A Study on the Environmental Condition and Safety in Dental Radiography Room (치과방사선 촬영실의 환경 및 안전성에 관한 연구)

  • Park, Il-Soon;Lee, Kyung-Hee
    • Journal of Korean society of Dental Hygiene
    • /
    • v.4 no.1
    • /
    • pp.49-64
    • /
    • 2004
  • This study is designed to conduct a questionnaire research into the safety control and the actual condition of radiography by working with dentistry belonging to university hospitals, dental hospitals and dental clinics for three months ranging from August, 2003 to October, 2003. The researcher came to the following conclusions. 1. The research on the current condition of possessed radiational equipment shows that 61.2 percent of the subjects had one intraoral radiation medicine and that 70.1 percent of the subjects had more than one extraoral radiation medicine and that 37.3 percent of the subjects had more than one digital radiation medicine. 2. Most of intraoral radiography (82.1%) was conducted by dental hygienists, and 7.5 percent of intraoral radiography was conducted by nurse aids. On the other hand, most of extraoral radiography (76.6%) was conducted by dental hygienists and digital radiography was conducted by dental hygienists(60.6%), dentists(32.0%) and radiographer(80.0%). 3. The less-than 1-meter-long distance between cone and the radiographer accounted for 44.8 percent. And the more-than 1.6-meter-long distance accounted for no more than 13.4 percent. The exposure time per standard film which was adjusted to each part accounted for 71.6 percent. Fixing the film on the part of healthy patients accounted for 76.1 percent. Fixing the film of elderly patients and children patients by the radiographer accounted for 43.3 percent. 4. The average daily photographing frequency of standard films stood at six to ten pieces(31.3%), and the average weekly photographing frequency of bitewing films stood at less than one piece(47.8%), and the dentistries where bitewing films were not employed accounted for 25.4%. The subjects whose average weekly photographing freqeuncy of occlusal films stood at less than a piece accounted for 59.7 percent. The dentistries whose average weekly photographing frequency of pediatric films stood at one to five pieces accounted for 41.8 percent. In case of panorama & cephalo, one to five pieces on a weekly average accounted for 36.2 percent. The dentistries whose average daily photographing frequency of digital radiation medicine stood at less than 1 piece accounted for 40.0 percent. 5. The research on the use of protective clothes shows that pregnant ·women only accounted for 31.3 percent. In regard to the use of protective clothes in case of the radiographers fixing films, the cases where no protective clothes were employed accounted for 88.1 percent. The reason was said to he attributable to the trouble related to wearing the clothes(54.2%). 6. The survey on the measurement of exposure dose shows that the cases where no measurement was made accounted for 76.1 percent. As far as the measurement methods of exposure dose was concerned, the employment of film badge accounted for 68.8 percent. The subjects turned out to conduct measurement of exposure dose every third month, which accounted for 43.8 percent. The barriers to the measurement of measurement of exposure dose were attributable to the recognition that a little amount of exposure dose need not be measured(29.9%). 7. The survey on the distinction of radiation rooms and clinic rooms reveals that the cases where radiation rooms exclusively existed accounted for 67.2 percent. 43.3 percent of the subjects turned out to have only one protective garment, and 49.3 percent of the subjects proved to conduct a periodical checkup of radiational equipment. The survey on the examination certificates of radiational generators and protective facilities indicates that 80.6 percent of the subjects had the certificates. The research also shows that the subjects with the marks indicating the radiational areas accounted for 70.1 percent. And trustees turned out to handle developing solutions and fixing solutions.

  • PDF

Affect of Pharmaceutical Byproduct and Cosmetic Industry Wastewater Sludge as Raw Materials of Compost on Damage of Red Pepper Cultivation (제약업종 부산물 및 화장품 제조업 폐수처리오니의 고추 비해에 미치는 영향)

  • Lim, Dong-Kyu;Lee, Sang-Beom;Kwon, Soon-Ik;Lee, Seung-Hwan;So, Kyu-Ho;Sung, Ki-Suk;Koh, Mun-Hwan
    • Korean Journal of Environmental Agriculture
    • /
    • v.23 no.4
    • /
    • pp.211-219
    • /
    • 2004
  • Three sludge types from pharmaceutical byproducts and one sludge type from cosmetic waste-water sludge as raw materials of compost were used in a field based concrete pot ($4\;m^2$, $2\;m{\times}2\;m$) for investigating damage of red pepper cultivation. These sludges and pig manure (1 Mg/10a, dry basis) were incorporated into the upper of clay loam soil prior to transplanting with red pepper. Changes in concentration and properties of heavy metal for both of soil and plant were investigated 4 times during of red pepper growth. Plant height and stem diameter of red pepper in sludge treatments except to Pharmaceutical sludge 3 were poor than those of NPK treatment. This result were regarded as an effect of incompleted decomposition sludge which has a lot of organic matter concentration. Amount of total As was increased rapidly Jul. 8. in soil, total Zn Cu Pb Cd were in harvest time, and 1 N-HCl extractable Zn Cu Pb Cd As were in harvest at middle stage and then decreased. Amounts of nitrogen in plant (leaf and stem) were high in Phamaceutical Sludge 1 and fig Manure treatment in early and middle stage because of organic matter and nitrogen concentrations and characteristics. Amounts of Zn, Pb, and Ni in leaf and amount of Zn and Pb in stem were increased in harvest time so that we need to have a concern in detail. Total yield of red pepper was Pig Manure > Phamaceutical Sludge 3 > Phamaceutical Sludge 1 > NPK > Phamaceutical Sludge 2 and Cosmetic Sludge treatment was decreased considerably to compare to others. Amounts of Zn and Cu in green and red pepper in harvest time were higher than the other heavy metals. Finally these results can use to utilize that finding damage on crop for authorization and suitability estimation of raw material of compost.

Characteristics of Nutrient Uptake by Water Plants in Free Water Surface Constructed Wetlands for Treating Non-point Source Pollution (비점오염원 처리를 위한 자유수면형 인공습지에서 수생식물의 영양염류 흡수특성 평가)

  • Kang, Se-Won;Seo, Dong-Cheol;Choi, Ik-Won;Lee, Jun-Bae;Lim, Byung-Jin;Park, Jong-Hwan;Kim, Kap-Soon;Kim, Sang-Don;Heo, Jong-Soo;Cho, Ju-Sik
    • Korean Journal of Environmental Agriculture
    • /
    • v.30 no.3
    • /
    • pp.304-309
    • /
    • 2011
  • BACKGROUND: Generally, water plants may play an important role in nutrients(N, P) removal in constructed wetlands(CWs). Previous studies considered nutrients uptake by water plants in various CWs for treating point source pollution. On the other hand, few studies considered nutrients uptake by water plants in free water surface(FWS) CWs for treating non-point source pollution. METHODS AND RESULTS: To investigate characteristics of nutrient uptake by water plants in FWS CWs, dry weights, nutrients content and nutrients uptake by water plants were investigated from April, 2008 to October, 2008. Dominance plants were Phragmites japonica STEUD (PHRJA), Nymphaea tetragona ANGUSTA(NTMTE), Typha orientalis PRESL(TYHOR), Phragmites communis TRINIUS(PHRCO) and Zizanis latifolia TURCZ(ZIZLA) in FWS CWs. The dry weights of water plants in August were higher in the order of TYHOR(54.27 g/plant) > PHRJA(44.30 g/plant) ${\geqq}$ PHRCO(39.60 g/plant) ${\geqq}$ ZIZLA(37.80 g/plant) ${\fallingdotseq}$ NTMTE(36.75 g/plant). The T-N and T-P contents by water plants were not significantly differences regardless of cultivation period. The maximum amount of T-N uptake by water plants in August were 773 mg/plant for PHRJA, 625 mg/plant for NTMTE, 1206 mg/plant for TYHOR, 754 mg/plant for PHRCO and 768 mg/plant for ZIZLA. The maximum amounts of T-P uptake by PHRJA, NTMTE, TYHOR, PHRCO and ZIZLA were 397, 177, 411, 261 and 229 mg/plant in August, respectively. CONCLUSION(s): The results of this study suggest that optimum water plant was Typha orientalis PRESL in free water surface constructed wetlands.

Dietary Effects of Post-fermented Green Tea by Monascus pilosus on the Body Weight, Serum Lipid Profiles and the Activities of Hepatic Antioxidative Enzymes in Mouse Fed a High Fat Diet (Monascus pilosus로 발효시킨 후발효 녹차가 고지방 식이 마우스의 체중과 혈청 지방함량 및 간 조직 항산화계 효소활성에 미치는 영향)

  • Lee, Sang-Il;Lee, Ye-Kyung;Kim, Soon-Dong;Yang, Seung-Hwan;Suh, Joo-Won
    • Journal of Applied Biological Chemistry
    • /
    • v.55 no.2
    • /
    • pp.85-94
    • /
    • 2012
  • The anti-obese, hypolipidemic and hepatoprotective effects of post-fermented green tea by Monascus pilosus was tested with mice fed with high-fat diet for 7 weeks. The body weight gain and feed efficiency ratio (FER) in normal control group (NC), CHA (2% non-fermented green tea powder supplemented high-fat diet group) and mCHA (2% green tea powder post-fermented by M. pilosus supplemented high fat diet group) groups were significantly lower than those of high fat diet control group (HC). Epididymal fat weight in mCHA and NC were significantly lower than HC. The hepatic lipid peroxide was dramatically higher in HC than that of NC and was significantly lower in CHA and mCHA. In addition, dehydrogenase type activity of xanthine oxidoreductase in HC was lower than that of NC, but significantly higher than CHA and mCHA. In histopathological findings, hepatic fat accumulation in HC was higher than that of NC, CHA and mCHA. Antiobese, hypolipidemic and antifatty liver effect of green tea powder post-fermented by M. pilosus was slightly higher than that of non-fermented green tea. In conclusion, the constituents of green tea fermented by M. pilosus has been proven to not only inhibit obesity and hyperlipidemia but also decrease the hepatic fat accumulation in high fat diet-induced obese mice.

A Study on the Cosmeceutical activities of Prunus Sargentii R. (산벚나무(Prunus sargentii R.) 수피의 화장품활성에 관한 연구)

  • Park, Jung-Mi;Lee, Jin-Young;Park, Tae-Soon;Hyun, Sok-Jun;Kim, Han-Hyuk;Cho, Young-Je;Kwon, O-Jun;Son, Ae-Ryang;Kim, Dong-Seok;An, Bong-Jeun
    • Applied Biological Chemistry
    • /
    • v.51 no.1
    • /
    • pp.70-78
    • /
    • 2008
  • Prunus sargentii R. of Rosaceae familiy, has been reported to have radical scavenging activity and anti-inflammatory effect. On these facts, biological activity and safety test were conducted to evaluate biological activities of the extracts of P. sargentii R. as a potential pharmaceutical ingredient. The electron donating ability of its ethanol extracts at a 500 ppm level showed 92%, which was higher than that of hot water extract (59%), the superoxide dismutase (SOD)-like activity of the water extract of P. sargentii R. was about 50%, the ethanol extract of P. sargentii R. was about 40% at 1,000 ppm concentration. Xanthine oxidase inhibition by the water extract of P. sargentii R. was about 40% and that by the ethanol extract was 60% respectively at 500 ppm concentration. From the measurement on lipid oxidation, the $Cu^{2+}$ chelating effect of the ethanol extract was higher than that of hot water extract. The $Fe^{2+}$ chelating effect was also shown to be about 80% at a 500 ppm concentration in both hot water extract and ethanol extract. The tyrosinase inhibition effect related to skin-whitening was 26% by hot water extract and 20% by ethanol extract respectively at a 1,000 ppm. Hyaluronidase inhibition activity related to the anti-inflammation effect was 96% in ethanolic extract at a 500 ppm. Clear zones formed by P. sargentii R. against the human skin-resident micro-flora such as Staphylococcus aureus, Staphylococcus epidermidis, Escherichia coli and Propionibacterium acnes indicated that antimicrobial activity of the ethanol extract was higher than that of the hot water extract.

Analyze for the Quality Control of General X-ray Systems in Capital region (수도권지역 일반촬영 장비의 정도관리 분석)

  • Kang, Byung-Sam;Lee, Kang-Min;Shim, Woo-Yong;Park, Soon-Chul;Choi, Hak-Dong;Cho, Yong-Kwon
    • Journal of radiological science and technology
    • /
    • v.35 no.2
    • /
    • pp.93-102
    • /
    • 2012
  • Thanks to the rapid increase of the interest in the quality control of the General X-ray systems, this research proposes the direction of the quality control through comparing and inspecting the actual condition of the respective quality control in the Clinic, the educational institution and the hospital. The subjects of the investigation are diagnostic radiation equipment's in the clinic, the educational institution and the hospital around the capital. A test of kVp, mR/mAs out put test and reproducibility of the exposure dose, half value layer, an accordance between the light field and the beam alignment test, and lastly reproducibility of the exposure time. Then the mean difference of the percentage, the CV (Coefficient of Variation, CV) and the attenuated curve which are respectively resulted from the above tests are computed. After that we have evaluated the values according to the regulations on the Diagnostic Radiation Equipment Safety Administration regulations. In the case of the clinic and the educational institution, there were 22 general X-ray devices. And 18.2% of the kVp test, 13.6% of the reproducibility of exposure dose test, 9.1% of the mR/mAs out put test, and 13.6% of the HVL (Half Value Layer) test appeared to be improper. In the case of the hospital, however, there were 28 devices. And 7.1% of the reproducibility of exposure dose, 7.1% of the difference in the light field/ beam alignment, and 7.1% of the reproducibility of the exposure time appeared to be improper. According to the investigation, the hospital's quality control condition is better than the condition in the clinic and the educational institution. The quality control condition of the general X-ray devices in the clinic is unsatisfactory compared to the hospital. Thus, it is considered that realizing the importance of the quality control is necessary.

Analysis of Factors Influencing the Integrated Bolus Peak Timing in Contrast-Enhanced Brain Computed Tomographic Angiography (Computed Tomographic Angiography (CTA)의 검사 시 조영제 집적 정점시간에 영향을 미치는 특성 인자를 분석)

  • Son, Soon-Yong;Choi, Kwan-Woo;Jeong, Hoi-Woun;Jang, Seo-Goo;Jung, Jae-Yong;Yun, Jung-Soo;Kim, Ki-Won;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.59-69
    • /
    • 2016
  • The objective of this study was to analyze the factors influencing integrated bolus peak timing in contrast-enhanced computed tomographic angiography (CTA) and to determine a method of calculating personal peak time. The optimal time was calculated by performing multiple linear regression analysis, after finding the influence factors through correlation analysis between integrated peak time of contrast medium and personal measured value by monitoring CTA scans. The radiation exposure dose in CTA was $716.53mGy{\cdot}cm$ and the radiation exposure dose in monitoring scan was 15.52 mGy (2 - 34 mGy). The results were statistically significant (p < .01). Regression analysis revealed, a -0.160 times decrease with a one-step increase in heart rate in male, and -0.004, -0.174, and 0.006 times decrease with one-step in DBP, heart rate, and blood sugar, respectively, in female. In a consistency test of peak time by calculating measured peak time and peak time by using the regression equation, the consistency was determined to be very high for male and female. This study could prevent unnecessary dose exposure by encouraging in clinic calculation of personal integrated peak time of contrast medium prior to examination.

Comparison of Noise Power Spectrum Methodologies in Measurements by Using Various Electronic Portal Imaging Devices in Radiation Therapy (방사선치료시 전자포털영상장치를 이용한 잡음전력스펙트럼 방법론 측정비교)

  • Son, Soon-Yong;Choi, Kwan-Woo;Jeong, Hoi-Woun;Kwon, Kyung-Tae;Kim, Ki-Won;Lee, Young-Ah;Son, Jin-Hyun;Min, Jung-Whan
    • Journal of radiological science and technology
    • /
    • v.39 no.1
    • /
    • pp.99-105
    • /
    • 2016
  • The noise power spectrum (NPS) is one of the most general methods for measuring the noise amplitude and the quality of an image acquired from a uniform radiation field. The purpose of this study was to compare different NPS methodologies by using megavoltage X-ray energies. The NPS evaluation methods in diagnostic radiation were applied to therapy using the International Electro-technical Commission standard (IEC 62220-1). Various radiation therapy (RT) devices such as TrueBeam$^{TM}$(Varian), BEAMVIEW$^{PLUS}$(Siemens), iViewGT(Elekta) and Clinac$^R$ iX (Varian) were used. In order to measure the region of interest (ROI) of the NPS, we used the following four factors: the overlapping impact, the non-overlapping impact, the flatness and penumbra. As for NPS results, iViewGT(Elekta) had the higher amplitude of noise, compared to BEAMVIEW$^{PLUS}$ (Siemens), TrueBeam$^{TM}$(Varian) flattening filter, Clinac$^{R}$iXaS1000(Varian) and TrueBeam$^{TM}$(Varian) flattening filter free. The present study revealed that various factors could be employed to produce megavoltage imaging (MVI) of the NPS and as a baseline standard for NPS methodologies control in MVI.