• Title/Summary/Keyword: Sonography

Search Result 277, Processing Time 0.024 seconds

Diagnostic Potential of Strain Ratio Measurement and a 5 Point Scoring Method for Detection of Breast Cancer: Chinese Experience

  • Parajuly, Shyam Sundar;Lan, Peng Yu;Yun, Ma Bu;Gang, Yang Zhi;Hua, Zhuang
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.4
    • /
    • pp.1447-1452
    • /
    • 2012
  • Aim: To evaluate the differential diagnostic potential of lesion stiffness assessed by the sonoelastographic strain index ratio (SR) and elastographic color scoring system (UE) for breast lesions. Materials and Methods: Three hundred and forty two breast masses (158 benign and 184 malignant) from 325 consecutive patients (mean age 44.2 years; range 16-81)who had been scheduled for a sonographically guided core biopsy were examined proposed by Itoh et al, with scoring 1-3=benign and 4-5=malignant. Strain and area ratios of each lesion were calculated within the same machine. Histological diagnosis was used as the reference standard. The area under the curve (AUC) and cut-off point were obtained by receiver operating curve and the cross table Fischer Test was carried out for assessing diagnostic value. Sensitivity, specificity, PPV, NPV, accuracy and false-discovery rates were compared. Results: The mean strain ratios for benign and malignant lesions were 1.87 and 7.9 respectively. (P<0.0001). When a cutoff point of 3.54 was used, SR had a sensitivity of 94.6%, a specificity 94.3%, a PPV of 95.1%, an NPV of 93.7% and an accuracy of 94.4%. The AUC values were 0.90 for the 5 point scoring system (UE) and 0.96 for the strain index ratio. The overall diagnostic performance was SR method was better (P<0.05). Conclusions: Strain ratio measurement could be another effective predictor in elastography imaging besides 5 the point scoring system for differential diagnosis of breast lesions.

BreastLight Apparatus Performance in Detection of Breast Masses Depends on Mass Size

  • Shiryazdi, Seyed Mostafa;Kargar, Saeed;Taheri-Nasaj, Hossein;Neamatzadeh, Hossein
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.16 no.3
    • /
    • pp.1181-1184
    • /
    • 2015
  • Background: Accurate measurement of breast mass size is fundamental for treatment planning. We evaluated performance of BreastLight apparatus in detection breast of masses with this in mind. Materials and Methods: From July 2011 to September 2013, a total of 500 women referred to mammography unit in Yazd, Iran for screening were recruited to this study. Performance of BreastLight in detection breast masses regard their sizeing, measured with clinical breast examination (CBE), mammography and sonography, was assessed. Sonographic and mammography examinations were performed according to breast density among women in two groups of women younger (n=105) and older (n=395) than 30 years. Size correlations were performed using Spearman rho analysis. Differences between mass size as assessed with the different methods (mammography, sonography, and clinical examination) and the BreastLight detection were analyzed using $X^2$-trend test. Results: Performance of the BreastLight in detection of lesions smaller than or equal to 1 cm assessed by CBE, mammography and sonography was 4.4%,7.7% and 12.5% and for masses larger than 4 cm was 65%, 100% and 57.1%, respectively. The performance of BreastLight in detection was significantly increased with larger masses (p<0.001). Conclusions: We conclude that clinical measurement of breast cancer size is as accurate as that from mammography or ultrasound. Accuracy can be improved by the use of a simple formula of both clinical and mammographic measurements.

Carotid Web in Duplex Sonography: 4 Cases (이중초음파에서 관찰된 경동맥갈퀴막: 4례)

  • Han, Minho;Seo, Kangsik;Choi, Junghye
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.52 no.1
    • /
    • pp.78-82
    • /
    • 2020
  • Carotid web is a disease that is rarely found in patients with ischemic stroke, whereas it is more frequently observed in cryptogenic stroke patients. Fibromuscular dysplasia is known as the cause of carotid web, and it has been reported that carotid web causes blood flow disturbance, resulting in both thrombus and embolic stroke. Carotid web is confused with carotid dissection because fibromuscular dysplasia causes relatively rigid fibrous structures to grow into the lumen of the carotid artery and this creates a double lumen that is seen on duplex sonography. In addition, carotid web is web-shaped and may be confused with other carotid artery diseases such as ulcerative plaque. However, carotid web tends to be thicker at the beginning and thinner at the end, and it also has no flutter. Therefore, this study reports on four cases of carotid web with the overall description of the carotid web and the characteristic findings of duplex sonography in patients with carotid web.

Usefulness of Routine Renal Sonography Screening for Healthy Infants with Isolated Single Umbilical Artery (단일 제대 동맥을 가진 건강한 신생아에서 신장 초음파 검사의 유용성)

  • Kang, Ju-Mi;Song, Eun-Song;Kuk, Jin-Hwa;Lee, Hyung-Sin;Kim, So-Young;Choi, Young-Youn
    • Clinical and Experimental Pediatrics
    • /
    • v.46 no.9
    • /
    • pp.854-857
    • /
    • 2003
  • Purpose : It is known that single umbilical artery is frequently associated with gastrointestinal or urogenital anomaly, however, routine renal sonography has been debated in healthy neonate with isolated single umbilical artery. This study is designed to determine the usefulness of routine renal sonography in apparently healthy infants with an isolated single umbilical artery. Methods : Thirty healthy neonates with a single umbilical artery without a major anomaly from January 1995 to July 2002 were enrolled. The authors investigated the clinical background of babies and their mothers after renal sonography after 72 hours of age. When the abnormalities were found at the first renal sonography, the severity of hydronephrosis and degree of obstruction and renal function were analyzed by follow up renal sonography, voiding cystourethrography(VCUG) and technetium-99m-dimercaptosuccinic acid(DMSA) scan or technetium-99m-mercaptoacetyl-triglycerine (MAG3) scan. Results : Among the 30 healthy patients with isolated single umbilical artery, five patients(16.7%) showed abnormalities on first renal sonography with one major(3.3%) and four(13.4%) minor renal anomaly(minimal or mild hydroneohrosis). One major renal anomaly(severe hydronephrosis) showed severe decreased renal function on MAG3 scan without reflux, and the other four minor regressed spontaneously on follow up study. Conclusion : The value of routine early renal sonograpy for detecting renal anomaly in healthy infants with an isolated single umbilical artery remained unclear because most of the anomalies would regress spontaneously in the follow up study.

Neonatal Intracranial Ischemia and Hemorrhage : Role of Cranial Sonography and CT Scanning

  • Khan, Imran Ahmad;Wahab, Shagufta;Khan, Rizwan Ahmad;Ullah, Kkram;Ali, Manazir
    • Journal of Korean Neurosurgical Society
    • /
    • v.47 no.2
    • /
    • pp.89-94
    • /
    • 2010
  • Objective : To evaluate the role of cranial sonography and computed tomography in the diagnosis of neonatal intracranial hemorrhage and hypoxic-ischemic injury in an Indian set-up. Methods : The study included 100 neonates who underwent cranial sonography and computed tomography (CT) in the first month of life for suspected intracranial ischemia and hemorrhage. Two observers rated the images for possible intracranial lesions and a kappa statistic for interobserver agreement was calculated. Results : There was no significant difference in the kappa values of CT and ultrasonography (USG) for the diagnosis of germinal matrix hemorrhage/intraventricular hemorrhage (GMH/IVH) and periventricular leucomalacia (PVL) and both showed good interobserver agreement. USG, however detected more cases of GMH/IVH (24 cases) and PVL (19) cases than CT (22 cases and 16 cases of IVH and PVL, respectively). CT had significantly better interobserver agreement for the diagnosis of hypoxic ischemic injury (HII) in term infants and also detected more cases (33) as compared to USG (18). CT also detected 6 cases of extraaxial hemorrhages as compared to 1 detected by USG. Conclusion : USG is better modality for imaging preterm neonates with suspected IVH or PVL. However, USG is unreliable in the imaging of term newborns with suspected HII where CT or magnetic resonance image scan is a better modality.

Sonographic Examination of the Soft Tissue Using Artifacts (인공물을 이용한 연조직의 초음파 검사)

  • Kim, Jung-Man
    • The Journal of Korean Orthopaedic Ultrasound Society
    • /
    • v.3 no.2
    • /
    • pp.91-96
    • /
    • 2010
  • The artifacts in sonography is not always harmful. Sometimes it is beneficial for the evaluation of the water contents of the soft tissue and estimating the degree of inflammation and character of the regenerated tissue indirectly using artifacts such as acoustic shadowing and the enhanced transmission. It can also be useful to evaluate the possibility of aspiration of the calcifies masses by knowing of the contents of the water among them. Unlike the MRI it is useful to get real time informations with low cost in diagnosis and treatment of the soft tissue disease usinf artifacts in sonography.

  • PDF

Control of clonorchiasis by repeated praziquantel treatment and low diagnostic efficacy of sonography (반복 집단 치료에 의한 간흡충증의 관리 및 진단에서 초음파검사의 저효용성)

  • Sung-Tae HONG;Kisung YOON;Mejeong LEE;Min SEO;Min-Ho CHOI;Jung Suk SIM;Byung Ihn CHOI;Chong Ku YUN;Soon-Hyung LEE
    • Parasites, Hosts and Diseases
    • /
    • v.36 no.4
    • /
    • pp.249-254
    • /
    • 1998
  • In Korea, Clonorchis sinensis infection is still highly prevalent because case detection in the field is difficult and the detected cases used to be incompletely cured due to treatment failure. The present study tried to control clonorchiasis in an endemic village by repeated treatments with praziquantel every 6 months and to evaluate sonography as a diagnostic measure. By stool examinations, the egg positive rate in the endemic village was 22.7%, but it decreased to 19.6% at 6 months. 15.1% at 12 months, 12.2% at 18 months, 6.3% at 24 months, 11.4% at 30 months, and 6.3% at 42 months after the beginning of repeated praziquantel administration. The sonography showed 61 (49.6%) positive cases of 123 screened residents; among egg-positives the sonography positive rate was 52.2% and among egg-negatives it was still 49%. The rate among cured cases was 64.3% after 6 months, 50.0% after 12 months, 50.0% after 18 months, and 66.7% after 24 months. In a non-endemic village, 64 residents were found egg-negative by fecal examination, but 20 (31.3%) of them were positive by sonography. The present findings indicate that control of clonorchiasis in an endemic village by repeated praziquantel treatment for 42 months is still insufficient and sonography is of little value for diagnosis of clonorchiasis.

  • PDF

Diagnosis of Morton's Neuroma Using MR Imaging scans (지간 신경종의 자기 공명 영상을 이용한 진단)

  • Hong, Ki-Do;Ha, Sung-Sik;Sim, Jae-Cheon;Kim, Jae-Young
    • Journal of Korean Foot and Ankle Society
    • /
    • v.7 no.1
    • /
    • pp.131-134
    • /
    • 2003
  • Most interdigital neuroma can be diagnosed clinically. But, diagnostic local injection method, sonography and magnetic resonance image(MRI) have been used as secondary tests for clinical confirmation or surgery. Recently, there have been active discussions on the method of interdigital neuroma diagnosis for which sonography or MRI is used. For finding out the location or the number of interdigital neuroma particularly in non-typical clinical manifestation or surgery, MRIs, which are exellent in tissue contrast, may be quite helpful. This case had an interdigital neuroma showing non-typical manifestation. MRIs were used for clinical diagnostic confirmation and finding out the location and the number of interdigital neuroma. Thus, the validity along with literary consideration is being reported.

  • PDF