• Title/Summary/Keyword: Solution Temperature

Search Result 6,373, Processing Time 0.031 seconds

The Effect of Solid Solution Heat-Treatment Temperature on the Tensile Property in Intermediate Thermo-Mechanical Treated Al-Li Alloys (중간가공열처리한 AI-Li계 합금의 인장성질에 미치는 용체화처리온도의 영향)

  • Yoo, C.Y.;Lee, K.B.
    • Journal of the Korean Society for Heat Treatment
    • /
    • v.4 no.1
    • /
    • pp.37-41
    • /
    • 1991
  • In this study, the effect of solution treatment temperature on the tensile property in intermediate thermo-mechanical treated Al-Li alloys are investigated. After the intermediate thermo-mechanical treated Al-Li, Al-Li-Mg and Al-Li-Mg-Zr alloys were solution treated at various temperatures (500, 520 and $540^{\circ}C$), these were aged at $190^{\circ}C$, $240^{\circ}C$ and tested tensile properties. The results obtained from the experiment are as follows ; 1) The optimum solution heat-treatment temperature is $540^{\circ}C$ for a Al-Li alloy, and the recrystallized grain size is about $70{\mu}m$. 2) The optimum solution heat-treatment temperature is $500^{\circ}C$ for a Al-Li-Mg alloy, and the recrystallized grain size is the most coarse in all alloys. 3) The tensile property is independent of the solution treatment temperature in a Al-Li-Mg-Zr alloy, and the recrystallized grain size is the finest owing to addition of Zr.

  • PDF

In Line Plastic-Optical-Fiber Temperature Sensor

  • Seo, Hyejin;Shin, Jong-Dug;Park, Jaehee
    • Current Optics and Photonics
    • /
    • v.5 no.3
    • /
    • pp.238-242
    • /
    • 2021
  • In this paper, we present an in line plastic-optical-fiber (POF) temperature sensor based on intensity modulation. The in line POF temperature sensor is composed of a POF, including an in-fiber micro hole filled with reversible thermochromic material, the transmittance of which depends on temperature. The reversible thermochromic material was cobalt chloride/polyvinyl butyral gel. A cobalt chloride solution of concentration 30.8 mM was formulated using 10% water/90% ethanol (v/v) solution, and gelled by dissolving polyvinyl butyral in this solution. Four types of in line POF sensors, with in line micro holes of four different diameters, were fabricated to measure temperature in the range of 25 to 75 ℃. The output optical power of all of these in line POF temperature sensors was inversely proportional to the temperature; the relation between output power and temperature was approximately linear, and the sensitivity was proportional to the diameter of the in-fiber micro hole. The experimental results indicate that an in line POF sensor can be used effectively for measuring moderate temperatures.

The Effects of 3.5% NaCl Aqueous Solution Temperature on the Corrosion Fatigue Fracture of Dual phase steel (3.5% NaCl 수용액의 온도변화가 복합조직강의 부식피로파괴에 미치는 영향)

  • 오세욱;도영문;박수영;김재철;김광영
    • Journal of Ocean Engineering and Technology
    • /
    • v.6 no.1
    • /
    • pp.140-147
    • /
    • 1992
  • Corrsion fatigue test was performed under rotated bending in 3.5% NaCl aqueous solution having a temperature from 278.deg.K in order to investigate the effects of aqueous solution remperature on the corrosion fatigue fracture of raw material steel(SS41) and dual phase steel that was produced from SS41 by a series of heat treatment. Corrosion fatigue life decreases remarkably with increase in solution temperature or with decrease in stress level. The corrosion fatigue life and the crack propagation rate at 303.deg.K show the similar behaviors with those at 318.deg.K, which is assumed to be caused by concentration polarization phenamena. The number and the lengths of microcracks increase with increase in solution temperature, so they lead to the decrease in corrosion fatigue life.

  • PDF

A Study on Performance Characteristics of A Single Effect LiBr/Water Refrigeration Cycle (단효용 LiBr/물 흡수식 냉동사이클의 성능특성에 관한 연구)

  • 연제문;임삼택;오주원;이경우
    • Proceedings of the Korean Society of Marine Engineers Conference
    • /
    • 2001.05a
    • /
    • pp.95-99
    • /
    • 2001
  • As a way to use energy effectively, the present study is aimed at investigating the performance characteristics of a Single Effect LiBr/Water Absorption Refrigerator using a low temperature driving heat-source. It was carried out by changing the driving heat-source temperature, the cold water outlet temperature(the refrigeration load), the cooling water inlet temperature, and the weak solution flow rate and this study compares the performance characteristics of refrigerator against the existence and non-existence of the Recirculation of the Weak solution which is used as a method to improve the performance of refrigerator. In case of Recirculation of the weak solution, more improved the Refrigeration Capacity and COP was obtained, and these effects became more larger in the high temperature of driving heat-source and large quantity of solution.

  • PDF

Effect of the Heating Temperature on the Alkali-activation Reaction of Calcined Kaolin Powder (열처리 카올린 분말의 알칼리활성화 반응에 미치는 가열온도의 영향)

  • Kim, Sung Gon;Song, Tae Woong
    • Journal of the Korean Ceramic Society
    • /
    • v.49 no.6
    • /
    • pp.601-607
    • /
    • 2012
  • The alkali-activation reaction of two types of typical kaolin calcined at various lower temperatures was investigated at room temperature and at elevated temperatures. For the assessment of the reactivity, the temperature increase and the setting time of pastes prepared with calcined kaolin and sodium/potassium hydroxide solution were measured. Unlike raw kaolin, calcined kaolin samples prepared at various temperature showed an alkali-activation reaction according to the different aspects of the changes in the mineral phases. The reactivity with alkaline solutions was exceedingly activated in the samples calcined at $600-650^{\circ}C$, but the reactivity gradually decreased as the temperature increased in a higher temperature range, most likely due to the changes in the crystal structure of the dehydrated kaolin. The activation effect of the calcination treatment was achieved at reaction temperatures that exceeded $60^{\circ}C$ and was enhanced as the temperature increased. The reactivity of the calcined kaolin with an alkaline solution was more enhanced with the solution of a higher concentration and with a solution prepared from sodium hydroxide rather than potassium hydroxide.

Deformation Property of TiC-Mo Solid Solution Single Crystal at High Temperature by Compression Test (TiC-Mo 고용체 단결정의 고온 압축변형 특성)

  • Shin, Soon-Gi
    • Korean Journal of Materials Research
    • /
    • v.24 no.11
    • /
    • pp.625-631
    • /
    • 2014
  • To investigate the deformation properties of TiC-(5-20) mol% Mo solid solution single crystals at high temperature by compression testing, single crystals of various compositions were grown by the radio frequency floating zone technique and were deformed by compression at temperature from 1250K to 2270K at strain rates from $5.1{\times}10^{-5}$ to $5.9{\times}10^{-3}/s$. The plastic flow property of solid solution single crystals was found to be clearly different among a three-temperature range (low, intermediate and high temperature ranges) whose boundaries were dependent on the strain rate. From the observed property, we conclude that the deformation in the low temperature range is controlled by the Peierls mechanism, in the intermediate temperature range by the dynamic strain aging and in the high temperature range by the solute atmosphere dragging mechanism. The work softening tends to become less evident with an increasing experimental temperature and with a decreasing strain rate. The temperature and strain rate dependence of the critical resolved shear stress is the strongest in the high temperature range. The curves are divided into three parts with different slopes by a transition temperature. The critical resolved shear stress (${\tau}_{0.2}$) at the high temperature range showed that Mo content dependence of ${\tau}_{0.2}$ with temperature and the dependence is very marked at lower temperature. In the higher temperature range, ${\tau}_{0.2}$ increases monotonously with an increasing Mo content.

A study on the Manufacture of the CuO Powder from Copper Chloride Solution by Spray Pyrolysis Process (분무열분해법에 의한 구리염화물 용액으로부터 CuO 분말 제조에 관한 연구)

  • Yu, Jae-Geun;Park, Hui-Beom
    • Korean Journal of Materials Research
    • /
    • v.12 no.1
    • /
    • pp.58-67
    • /
    • 2002
  • In this study copper chloride(CuCl$_2$) solution was used as raw material to produce the fine copper oxide powder which has less than 1 $\mu\textrm{m}$ average particle size and has uniform particle size distribution by spray pyrolysis process. In the present study, the effects of reaction temperature, the injection speed of solution and air, the nozzle tip size and the concentration of raw material solution on the properties of produced powder were studied. The structure of the powder became much more compact with increasing the reaction temperature regardless of copper concentration of the raw material solution. The particle size of the powder increased accordingly with increasing the reaction temperature in case of 30 g/$\ell$ copper concentration of the solution. The particle size of the powder increased accordingly, and the surface structure of the powder became more porous with increasing the copper concentration of the raw material solution. When copper concentration in raw material solution was more than 100 g/$\ell$, all produced powder was CuCl regardless of reaction temperatures. When copper concentration in solution was below 30 g/$\ell$ and reaction temperature was higher than 90$0^{\circ}C$, CuO was the main phase. The surface of the powder tended to become porous with increasing the injection speed of solution. Particle size was increased and the surface of the powder showed severely disrupted state with increasing the nozzle tip size. The particle size was decreased and the particle size distribution was more uniform with increasing the air pressure through the nozzle.

Effect of Curing Temperature on Geopolymeric Polycondensation of Blast Furnace Slag (고로슬래그의 지오폴리머 축중합반응에 미치는 양생온도의 영향)

  • Jeon, Chang-Seob;Song, Tae-Woong
    • Journal of the Korean Ceramic Society
    • /
    • v.48 no.6
    • /
    • pp.610-616
    • /
    • 2011
  • The effect of curing temperature on basic geopolymeric reactivity and hardening behaviour of blast furnace slag were investigated using the mixture of pulverized slag and several alkaline solutions of relatively high concentration. For the pastes prepared at several different temperatures between 20$^{\circ}C$ and 90$^{\circ}C$, setting time and heat of reaction were examined while mineralogical and morphological examinations were performed for the hardened paste after curing period at same temperature. The geopolymeric reaction of slag was revealed to be accelerated strongly according to the curing temperature regardless of the sort and concentration of the alkaline solution. The increase of concentration of the alkaline solution within 9M and the existence of silicic ion in the solution also promoted the reaction severely. The mineral component and their ratio of the hardened paste were revealed to be influenced by the chemical species and silicic ion contained in alkaline solution rather than by the curing temperature. The higher temperature and longer period of curing stage were effective for the sustained formation of geopolymer and succeed improvement of density and uniformity of morphology of the final hardened body.

A study on the estimation of temperature distribution around gas storage cavern

  • Lee Yang;Moon Hyun-Koo
    • 한국지구물리탐사학회:학술대회논문집
    • /
    • 2003.11a
    • /
    • pp.238-243
    • /
    • 2003
  • As there are many advantages on underground caverns, such as safety and operation, they can also be used for gas storage purpose. When liquefied gas is stored underground, the cryogenic temperature of the gas will affect the stability of the storage cavern. In order to store the liquefied gas successfully, it is essential to estimate the exact temperature distribution of the rock mass around the cavern. In this study, an analytic solution and a conceptual model that can estimate three-dimensional temperature distribution around the storage cavern are suggested. When calculating the heat transfer within a solid, it is likely to consider the solid as the intersection of two or more infinite or semi-infinite geometries. Therefore heat transfer solution for the solid is expressed by the product of the dimensionless temperatures of the geometries, which are used to form the combined solid. Based on the multi-dimensional transient heat transfer theory, the analytic solution is successfully derived by assuming the cavern shape to be of simplified geometry. Also, a conceptual model is developed by using the analytic solution of this study. By performing numerical experiments of this multi-dimensional model, the temperature distribution of the analytic solution is compared with that of numerical analysis and theoretical solutions.

  • PDF

Type of Solution and the Effects of Temperature Change in a Rapid Appraisal of Cement Fineness with a Liquid Densimeter (액체밀도계에 의한 시멘트의 분말도 신속평가에서 용액 종류 및 온도변화의 영향)

  • Lee, Jae-Jin;Kim, Min-Sang;Moon, Byeong-Yong;Kim, Yeong-Tae;Han, Min-Cheol;Han, Cheon-Goo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.167-168
    • /
    • 2017
  • With the recent increase in demand for construction there has been an increase in the use of the raw material cement when mixing concrete; managing quality of cement powder, therefore, is most important. Therefore this study sought at first to develop a rapid appraisal using the Hydrometer method researched previously, for it was thought that when suspending cement in a solution and applying the Hydrometer method to it the temperature changes in the solution would have a great effect on the density value of the Hydrometer method; yet there has been no report of such influence factors. Therefore after analyzing the influence factors that the type of suspending solution and changes in temperature could have on rapid appraisal of fineness, using the Hydrometer method, this study was able to determine that using water at 20℃ was the most appropriate, and with every temperature increase of 10℃ the value of fineness should also be increased above or below 7% as well.

  • PDF