• Title/Summary/Keyword: Solute leakage

Search Result 8, Processing Time 0.018 seconds

Differences of Germination Rate, Degree of Solute Leakage and Water Uptake Rate of Soybean Seeds in Two Storage Periods (저장기간에 따른 콩종실의 발아율이, 용출정도 및 수분흡수율의 차이)

  • 손범영;박금룡;김석동;김수희
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.41 no.1
    • /
    • pp.95-102
    • /
    • 1996
  • This investigation was conducted to investigate if germination rate, degree of solute leakage and water uptake rate of seeds are a meaningful information for the selection criteria among soybean genotypes and to find out their characteristics in the variable temperature and moisture conditions encounted during long-term warehouse storage. Germination rate in soybean sprouting box and petri dish differed largely among genotypes stored for twenty months but there was little difference when stored for eight months. Length of hypocotyl was shorter at twenty months of storage than at eight months. Degree of solute leakage of Paldalkong and Pulmuwon was twice higher than that of SS88038 lines at twenty months of storage. In 30 minutes after imbibition, water uptake rate in all genotypes stored for twenty months was faster than these stored for eight months, and water uptake rate in Paldalkong and Pulmuwon stored for eight months was 1.5 and 2 times faster than in SS88038 lines. In correlation coefficients, the germination ability and emergence exhibited significantly negative correlation with degree of solute leakage at twenty months of storage. Water uptake rate in soybean seeds stored for eight months had highly significant positive correlation with degree of solute leakage in 30 minutes and one hour after imbibition while for twenty months of storage, it had highly significant positive correlation with that in 30 minutes, one hour and three hours after imbibition. In eight months of storage, the number of open micropyle had positive correlation with water uptake rate at 30 minutes after imbibiton. But in seeds stored twenty months, it wasn't correlated with water uptake.

  • PDF

Analyses on Solute Transport with the Movement of an LNAPL on the Water Table (지하수면 위의 LNAPL 이동을 고려한 용질이동에 대한 분석)

  • 김지훈;최종근
    • Journal of Soil and Groundwater Environment
    • /
    • v.8 no.3
    • /
    • pp.1-7
    • /
    • 2003
  • A modified model was developed for solute transport in porous media that can consider the movement of an LNAPL above the water table. From the results of sensitivity analyses with and without considering LNAPL movement, there are some differences according to the hydraulic gradient, the quantity of oil leakage and dispersivity. The mean deviation between the model in this study and a conventional model without LNAPL movement increases as the hydraulic gradient decreases and the quantity of oil leakage increases. Variation of dispersivity has no influence on the magnitude of the mean deviation. However, the spatial distribution of the deviation between the two models is wider as dispersivity increases. Furthermore, groundwater is at high risk of contamination in the vertical direction in the case that transverse dispersion value is large. A conventional model underestimates the concentration of solute in an aquifer where the movement of an LNAPL cannot be negligible: Based on the study results, it is important to understand how fast the LNAPL moves on the water table for realistic prediction of solute transport in an aquifer with the movable LNAPL on the water table.

Electrical Properties of PVP Gate Insulation Film on Polyethersulfone(PES) and Glass Substrates (Polyethersulfone(PES) 및 유리 기판위에 제작된 PVP 게이트 절연막의 전기적 특성)

  • Shin, Ik-Sup;Gong, Su-Cheol;Lim, Hun-Seoung;Park, Hyung-Ho;Chang, Ho-Jung
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.14 no.1
    • /
    • pp.27-31
    • /
    • 2007
  • The cpapcitors with MIM(metal-insulator-metal) structures using PVP gate insulation films were prepared for the application of flexible organic thin film transistors (OTFT). The co-polymer organic insulation films were synthesized by using PVP(poly-4-vinylphenol) as a solute and PGMEA(propylene glycol monomethyl ether acetate) as a solvent. The cross-linked PVP insulation films were also prepared by addition of poly(melamine-co-formaldehyde) as thermal hardener. The leakage current of the cross- linked PVP films was found to be about 1.3 nA on Al/PES(polyethersulfone) substrate, whereas, on ITO/ glass substrate was about 27.5 nA indicating improvement of the leakage current at Al/PES substrates. Also, the capacitances of all prepared samples on ITO/glass and Al/PES substrates w ere ranged from 1.0 to $1.2nF/cm^2$, showing very similar result with the calculated capacitance values.

  • PDF

Assessing pollutants' migration through saturated soil column

  • Smita Bhushan Patil;Hemant Sharad Chore;Vishwas Abhimanyu Sawant
    • Membrane and Water Treatment
    • /
    • v.14 no.2
    • /
    • pp.95-106
    • /
    • 2023
  • In the developing country like India, groundwater is the main sources for household, irrigation and industrial use. Its contamination poses hydro-geological and environmental concern. The hazardous waste sites such as landfills can lead to contamination of ground water. The contaminants existing at such sites can eventually find ingress down through the soil and into the groundwater in case of leakage. It is necessary to understand the process of migration of pollutants through sub-surface porous medium for avoiding health risks. On this backdrop, the present paper investigates the behavior of pollutants' migration through porous media. The laboratory experiments were carried out on a soil-column model that represents porous media. Two different types of soils (standard sand and red soil) were considered as the media. Further, two different solutes, i.e., non-reactive and reactive, were used. The experimental results are simulated through numerical modeling. The percentage variation in the experimental and numerical results is found to be in the range of 0.75- 11.23 % and 0.84 - 1.26% in case of standard sand and red soil, respectively. While a close agreement is observed in most of the breakthrough curves obtained experimentally and numerically, good agreement is seen in either result in one case.

Preparation and Properties of PVP (poly-4-vinylphenol) Gate Insulation Film For Organic Thin Film Transistor (유기박막 트랜지스터용 PVP (poly-4-vinylphenol) 게이트 절연막의 제작과 특성)

  • Baek, In-Jae;Yoo, Jae-Hyouk;Lim, Hun-Seung;Chang, Ho-Jung;Park, Hyung-Ho
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.12 no.4 s.37
    • /
    • pp.359-363
    • /
    • 2005
  • The organic insulation devices with MIM (metal-insulator-metal) structures as PVP gate insulation films were prepared for the application of organic thin film transistors (OTFT). The co-polymer organic insulation films were synthesized by using PVP(poly-4-vinylphenol) as solute and PGMEA (propylene glycol monomethyl ether acetate) as solvent. The cross-linked PVP insulation films were also prepared by addition of poly (melamine-co-formaldehyde) as thermal hardener. The leakage current of the cross-linked PVP films was found to be about 300 pA with low current noise. and showed better property in electrical properties as compared with the co-polymer PVP insulation films. In addition, cross-linked PVP insulation films showed better surface morphology (roughness), showing about 0.11${\~}$0.18 nF in capacitance for all PVP film samples.

  • PDF

Organic Thin Film Transistors with Cross-Linked PVP Gates (Cross-Linked PVP 게이트 유기 박막트랜지스터)

  • Jang Ji-Geun;Oh Myung-Hwan;Chang Ho-Jung;Kim Young-Seop;Lee Jun-Young;Gong Myoung-Seon;Lee Young-Kwan
    • Journal of the Microelectronics and Packaging Society
    • /
    • v.13 no.1 s.38
    • /
    • pp.37-42
    • /
    • 2006
  • The preparation and processing of PVP-gate insulators on the device performance have been studied in the fabrication of organic thin film transistors (OTFTs). One of polyvinyl series, poly-4-vinyl phenol(PVP) was used as a solute and propyleneglycol monomethyl etheracetate(PGMEA) as a solvent in the formation of organic gate solutions. The cross-linking of organic insulators was also attempted by adding the thermosetting material, poly (melamine-co-formaldehyde) as a hardener in the compounds. From the measurements of electrical insulating characteristics of metal-insulator-metal (MIM) samples, PVP-based insulating layers showed lower leakage current according to the increase of concentration of PVP and poly (melamine-co-formaldehyde) to PGMEA in the formation of organic solutions. The PVP(20 wt%) copolymer with composition of 20 wt% PVP to PGMEA and cross-linked PVPs in which 5 wt% and 10 wt% poly (melamine-co-formaldehyde) hardeners had been additional]y mixed into PVP(20 wt%) copolymers were used as gate dielectrics in the fabrication of OTFTs, respectively. In our experiments, the maximum field effect mobility of $0.31cm^2/Vs$ could be obtained in the 5 wt% cross-linked PVP(20 wt%) device and the highest on/off current ratio of $1.92{\times}10^5$ in the 10 wt% cross-linked PVP(20 wt%) device.

  • PDF

Enhanced drought and oxidative stress tolerance in transgenic sweetpotato expressing a codA gene (CodA 고발현 형질전환 고구마의 산화 및 건조 스트레스 내성 증가)

  • Park, Sung-Chul;Kim, Myoung Duck;Kim, Sun Ha;Kim, Yun-Hee;Jeong, Jae Cheol;Lee, Haeng-Soon;Kwak, Sang-Soo
    • Journal of Plant Biotechnology
    • /
    • v.42 no.1
    • /
    • pp.19-24
    • /
    • 2015
  • Glycine betaine (GB) is one of the compatible solutes that accumulate in the chloroplasts of certain halotolerant plants under salt or cold stress. The codA gene for choline oxidase, the enzyme that converts choline into GB, has been cloned from a soil bacterium Arthrobacter globiformis. We generated transgenic sweetpotato plants [Ipomoea batatas (L.) Lam] expressing codA gene in chloroplasts under the control of the SWPA2 promoter (referred to as SC plants) and evaluated SC plants under oxidative and drought stresses. SC plants showed enhanced tolerance to methyl viologen (MV)-mediated oxidative stress and drought stress due to induced expression of codA. At $5{\mu}M$ of MV treatment, all SC plants showed enhanced tolerance to MV-mediated oxidative stress through maintaining low ion leakage and increased GB levels compared to wild type plants. When plants were subjected to drought conditions, SC plants showed enhanced tolerance to drought stress through maintaining high relative water contents and increased codA expression compared to wild type plants. These results suggest that the SC plants generated in this study will be useful for enhanced biomass production on global marginal lands.

Comparision of Combined Stress Tests for Predicting Field Emergence of Lotus corniculatus and Trifolium pratense (Birdsfoot Trefoil과 Red Clover의 포장출현율 예측을 위한 몇가지 Stress 검정법 비교)

  • Kim, Seok-Hyeon;Choe, Zhin-Ryong;Chung, Min-Hong;Han, Kyeong-Ho
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.37 no.2
    • /
    • pp.171-177
    • /
    • 1992
  • The purpose of this study was to compare the test methods for predicting field emergence of Lotus corniculatus and Trifolium pratense. Four seed lots of two herbage legumes were controlled deteriorated, accelerated aged before germination test and conductivity of each seed lot was determined. Those germination percent and conductivity of seed lots were compared with actual field emergence rate. Field emergence rate could be estimated by the controlled deterioration test ($R^2$=0.687), by the accelerated aging test ($R^2$=0.260), and by the conductivity test ($R^2$=0.238). A multiple regression equation for predicting field emergence rate(equation omitted) was estimated as (equation omitted)=-198.16 + 2.3493X$_1$-1.5564X$_2$ + 1.9812X$_3$where X$_1$, percent germination of controlled deterioration test ; X$_2$, percent germination of accelerated aging test; and X$_3$, conductivity of solute leakage in the conductivity test. Conclusively, unless multiple tests are not available, the controlled deterioration test was comparatively high efficient for predicting field emergence rate, however, the combined measurements of those three tests can enhance the efficiency.

  • PDF