• 제목/요약/키워드: Solar-wind hybrid generation system

검색결과 37건 처리시간 0.023초

태양광.풍력 복합발전시스템 특성분석 (Inquiry of Photovoltaic/Wind Hybrid Generation System)

  • 정영석;이병구;강기환;소정훈;정명훈;송진수
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 1999년도 전력전자학술대회 논문집
    • /
    • pp.419-422
    • /
    • 1999
  • This paper deals with stand-alone Photovoltaic system(SPVS) with charger/discharge controller. Main power source of SPVS are generally solar cel and battery. Therefore SPVS can be classified into variable types in accordance with connection type between battery and solar cell. SPVS with charger/discharge controller which can operate solar cell a maximum power point is suggested and designed with instantaneous controller. And system operating characteristics are verified by experiment with a laboratory prototype in this paper.

  • PDF

독립형 태양광, 풍력, 소형발전기 복합시스템에서 안정적인 전력공급을 위한 컨트롤러에 관한 연구 (The Study on the Controller for Supplying Stably Power with a Stand-Alone Photovoltaic/Wind/Small Generator Hybrid Power Generation System)

  • 최병수;김재철
    • 조명전기설비학회논문지
    • /
    • 제26권4호
    • /
    • pp.48-56
    • /
    • 2012
  • The object of this paper is the controller for supplying stably power in a separate house in which a hybrid electrical storage system with a stand-alone photovoltaic/wind power generation system and a small generator is applied. In the photovoltaic/wind hybrid power system used in the separate house, when only the battery is used in sunless days, the capacity of the battery is become larger. In particular, as in recent days, if cloudy days are frequent due to anomaly climate, it is difficult to estimate the number of sunless days. Accordingly, it is preferable to build the electrical storage system that numbers of sunshineless days are to be controlled and a shortage amount of the power generation capacity is to be handled by a small generator system. In order to supply stably power of new renewable energy such as solar to any separate houses, it is preferable to reduce the capacity of battery by decreasing the number of sunless days when estimating the capacity of battery and to drive the small generator for compensation of the power shortage. Such system needs components including inverters for photovoltaic and wind power generation system, batteries and controllers for automatically driving the small generator, based upon the nature of the stand-alone house, and it is preferable to use the controller having a simpler and higher stability by adopting the all-in-one scheme to facilitate its maintenance.

하이브리드 모델을 이용하여 중단기 태양발전량 예측 (Mid- and Short-term Power Generation Forecasting using Hybrid Model)

  • 손남례
    • 한국산업융합학회 논문집
    • /
    • 제26권4_2호
    • /
    • pp.715-724
    • /
    • 2023
  • Solar energy forecasting is essential for (1) power system planning, management, and operation, requiring accurate predictions. It is crucial for (2) ensuring a continuous and sustainable power supply to customers and (3) optimizing the operation and control of renewable energy systems and the electricity market. Recently, research has been focusing on developing solar energy forecasting models that can provide daily plans for power usage and production and be verified in the electricity market. In these prediction models, various data, including solar energy generation and climate data, are chosen to be utilized in the forecasting process. The most commonly used climate data (such as temperature, relative humidity, precipitation, solar radiation, and wind speed) significantly influence the fluctuations in solar energy generation based on weather conditions. Therefore, this paper proposes a hybrid forecasting model by combining the strengths of the Prophet model and the GRU model, which exhibits excellent predictive performance. The forecasting periods for solar energy generation are tested in short-term (2 days, 7 days) and medium-term (15 days, 30 days) scenarios. The experimental results demonstrate that the proposed approach outperforms the conventional Prophet model by more than twice in terms of Root Mean Square Error (RMSE) and surpasses the modified GRU model by more than 1.5 times, showcasing superior performance.

고립지역의 풍력/디젤 복합발전 전력품질 특성 (The Power Quality about Wind/Diesel combined power generation in isolated area)

  • 고석환;김석우;이윤섭
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2009년도 춘계학술발표대회 논문집
    • /
    • pp.245-249
    • /
    • 2009
  • Antarctic King Sejong Station was established in King George Island, the South Pole in 1988, and has been executing the monitoring studies on the change of antarctic natural environment. As an available power, the wind energy generator has been used in the form of hybrid with mainly diesel generator. Because the wind generation power sharply changes by wind energy, it must be careful during the system operation. When the power system becomes stable, the output performance of wind energy generator becomes stable. But, in case of unstable system, the errors frequently occur on the wind energy generator and it badly impacts the power system by output of wind energy generator. The purpose of this paper is to analyze suitability while operating the system of 10kW wind energy generator at Antarctic King Sejong Station, an isolated area, and to analyze the problem and improvements by power quality.

  • PDF

Prioritizing the locations for hydrogen production using a hybrid wind-solar system: A case study

  • Mostafaeipour, Ali;Jooyandeh, Erfan
    • Advances in Energy Research
    • /
    • 제5권2호
    • /
    • pp.107-128
    • /
    • 2017
  • Energy is a major component of almost all economic, production, and service activities, and rapid population growth, urbanization and industrialization have led to ever growing demand for energy. Limited energy resources and increasingly evident environmental effects of fossil fuel consumption has led to a growing awareness about the importance of further use of renewable energy sources in the countries energy portfolio. Renewable hydrogen production is a convenient method for storage of unstable renewable energy sources such as wind and solar energy for use in other place or time. In this study, suitability of 25 cities located in Iran's western region for renewable hydrogen production are evaluated by multi-criteria decision making techniques including TOPSIS, VIKOR, ELECTRE, SAW, Fuzzy TOPSIS, and also hybrid ranking techniques. The choice of suitable location for the centralized renewable hydrogen production is associated with various technical, economic, social, geographic, and political criteria. This paper describes the criteria affecting the hydrogen production potential in the study region. Determined criteria are weighted with Shannon entropy method, and Angstrom model and wind power model are used to estimate respectively the solar and wind energy production potential in each city and each month. Assuming the use of proton exchange membrane electrolyzer for hydrogen production, the renewable hydrogen production potential of each city is then estimated based on the obtained wind and solar energy generation potentials. The rankings obtained with MCDMs show that Kermanshah is the best option for renewable hydrogen production, and evaluation of renewable hydrogen production capacities show that Gilangharb has the highest capacity among the studied cities.

태양 전지와 압전 재료를 이용한 하이브리드 발전시스템 개발 (Development of a Hybrid Power Generation System Using Photovoltaic Cells and Piezoelectric Materials)

  • 김영민;;;천원기
    • 한국태양에너지학회 논문집
    • /
    • 제39권1호
    • /
    • pp.51-58
    • /
    • 2019
  • This paper deals with the operation of a hybrid power generation system made with photovoltaic cells and piezoelectric materials. The system can produce power from the wind as well as from the sun subject to their availability. Irrespective of the largeness of their power production, the power developed by both generators (i.e., phtovoltaic cells and piezoelectric cells) were combined and stored before it was applied to a load. Especially, the AC power (current) developed from each piezoelectric generator was converted by a full wave bridge rectifier and then combined prior to its storage in a capacitor. It was observed that the system can produce a maximum output power of 6.49 mW at loading resistance of $100{\Omega}$.

신재생에너지 활용을 위한 휴대용 태양광.풍력 복합 발전 시스템 (A Portable Hybrid Solar-Wind Power Generation System for Utilization of Renewal Energy)

  • 이창성;이재민
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2009년도 춘계학술발표논문집
    • /
    • pp.645-648
    • /
    • 2009
  • 본 논문에서는 신재생에너지 활용을 위한 휴대용 하이브리드 태양광 풍력 발전 시스템을 제안한다. 제안하는 태양광 풍력 복합 발전 시스템을 상용전기와 연계하여 사용할 경우를 고려하여 중대형 풍력 발전 시스템용 인버터와는 다른 특성이 요구되는 소형풍력 발전 시스템용 인버터와 독립형으로의 사용을 위해 축전지 충방전 컨트롤러를 개발한다. 20W의 Solar Power, 50W의 Wind Power, 1개의 Radio-recorder, 2개의 DC 7W/9W lamp. 축전지 Controller, 24H/40AH Maintenance-free battery 사양을 갖는 발전 시스템을 제작하고 필드 테스트를 통하여 성능을 검증한다.

  • PDF

Modeling of Solar/Hydrogen/DEGS Hybrid System for Stand Alone Applications of a Large Store

  • Hong, Won-Pyo
    • 조명전기설비학회논문지
    • /
    • 제27권11호
    • /
    • pp.57-68
    • /
    • 2013
  • The market for distributed power generation based on renewable energy is increasing, particularly for standalone mini-grid applications in developing countries with limited energy resources. Stand-alone power systems (SAPS) are of special interest combined with renewable energy design in areas not connected to the electric grid. Traditionally, such systems have been powered by diesel engine generator sets (DEGS), but also hybrid systems with photovoltaic and/or wind energy conversion systems (WECS) are becoming quite common nowadays. Hybrid energy systems can now be used to generate energy consumed in remote areas and stand-alone microgrids. This paper describes the design, simulation and feasibility study of a hybrid energy system for a stand-alone power system. A simulated model is developed to investigate the design and performance of stand-alone hydrogen renewable energy systems. The analysis presented here is based on transient system simulation program (TRNSYS) with realistic ventilation load of a large store. Design of a hybrid energy system is site specific and depends on the resources available and the load demand.

전기버스용 100kW급 충전인프라 개발 (Development of a 100kW charging infra for electrical bus)

  • 이충우;오승훈;이윤재;최은식;강병관;류강열;김희중
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2013년도 추계학술대회 논문집
    • /
    • pp.117-118
    • /
    • 2013
  • Recent global warming to the promotion of electric vehicles (EV), plug-in hybrid (PEV), including the next generation of cars and solar power, wind power and other renewable energy, and next-generation power grid (smart grid) are getting attention. In addition, the system utilizes the battery life in the industry and the convenience of a variety of social systems, economics, environmental impact, and the inherent potential to change significantly, and you can not walk into a next-generation industrial strategy and the need increases more and more present, and its early commercialization In order to do this, as well as a key energy source, the battery charger for charging efficiency technologies is essential. In this paper, fast charge multiple battery modules and optional modules that can charge distribution charge will be introduced.

  • PDF

도서지역 신·재생복합 전력시스템 보급 타당성 분석 -3개 도서지역 분석결과- (A Pre-Feasibility Test of Introducing Renewable Energy Hybrid Systems -Case Studies for 3 Off-Grid Islands-)

  • 장하나;김수덕
    • 자원ㆍ환경경제연구
    • /
    • 제15권4호
    • /
    • pp.693-712
    • /
    • 2006
  • 하이브리드 시스템의 최적 설계 및 운영을 위한 프로그램으로 해외의 여러 곳에서 활용중인 Homer를 사용하여 현재 디젤발전기를 전원으로 사용하고 있는 독립계통의 도서지역에 신 재생에너지원의 조합으로 구성된 하이브리드 시스템을 보급할 경우의 타당성 분석을 시도하였다. 에너지기술연구원의 풍속자료, 일사량, 온도자료 등을 근거로 추자도, 거문도, 그리고 영산도를 평가대상으로 선정하였다. 해당지역의 전력부하 자료는 부분적으로 실측된 자료를 바탕으로 재구성하였으며, 시스템 구성 발전기들의 비용 자료는 국내 관련 자료가 미비한 관제로 해외 시장의 자료를 이용하였다. 추자도, 거문도, 영산도의 평가결과가 각각 278원/kWh, 234원/kWh 그리고 353원/kWh으로 나타났다. 정부 보조금에 의한 디젤발전시스템의 발전단가가 300원/kWh($0.300/kWh)인 것을 고려한다면, 추자도와 거문도는 자체적으로 경제성을 확보하는 반면 영산도의 경우는 그렇지 못함을 알 수 있다. 이러한 결과 차이는 기본적으로 해당지역의 재생에너지 자원조건의 차이, 그 중에서도 특히 풍력자원의 차이에 기인하는 것으로 나타난다. 결론적으로 독립계통의 도서지역에 대한 신 재생복합전력시스템의 도입은 경제성 평가의 결과에 의거해야 하며 모든 도서지역이 이 조건을 충족시키는 것이 아님을 지적한다.

  • PDF